Installation Instructions for Greta
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electrical shock, exposure to excessive UV radiation, or injury to persons:
- Use this fixture indoors only.
- Do not look directly at the lamp while the fixture is on.
- RISK OF FIRE: Use only the type of lamp and maximum wattage indicated in this instruction manual.
- Never cover the halogen lamp with anything other than a lamp shield provided by Edge Lighting and never place flammable material close to the fixture.
- Never turn the fixture on and off by connecting and disconnecting the halogen lamp.
- Do not touch the fixture head, shade or lamp shield while the fixture is on. These surfaces may be VERY HOT.
- Do not touch lamp at anytime. Use a soft cloth instead as oil from skin may damage lamp.
- It is normal for a new halogen lamp to produce minor smoke when first turned on.
- Turn power off and allow to cool before replacing lamp.
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
IMPORTANT INFORMATION
- This product is ETL listed for indoor dry locations.
- This product is wall mounted only, either vertically or horizontally.
- This product can mount to either a 4" square electrical box with round plaster ring or an octagon electrical box.
GRETA-W-_-H1-_
M2-IND-_
CENTER MOUNT INSTALLATION
OFF-CENTER MOUNT INSTALLATION
904-GRETA-W-H1-08
SAVE THESE INSTRUCTIONS!
Disassemble the Fixture
A
GLASS SHADE
1
1
PHILLIPS SCREW
SLOT
SCREW HEAD
BACKPLATE
1: Remove the Phillips screw on the top of the glass shade and slide the glass shade up to remove it from the backplate.
B
THREADED STUD
THUMB NUT
2
THREADED STUD
BACKPLATE
SOCKET PLATE
2:
Remove the four thumb nuts from the threaded studs to
detach the socket plate from the backplate.
THUMB NUT
2
1
C
PHILLIPS SCREW
Unscrew the two Phillips screws in the center of the
3: backplate to remove the crossbar. These screws will
be used at a different location later during installation.
3
BACKPLATE
Feed the power wires through the crossbar center cutout.
1:
Level the two inner threaded holes (spaced 1" apart) either
2: horizontally (to mount the Greta for vertical position), or vertically (to mount the Greta for horizontal position). Secure the crossbar to the electrical box with the provided two #8-32 screws.
E
SOCKET PLATE
4
5 6
3
CROSSBAR
BACKPLATE
Install the Fixture
D
ELECTRICAL BOX HOLE
CROSSBAR
1
#8-32 SCREW
NOTE: It is recommended a person to hold the fixture while the
electrician connects the power to the fixture.
3: While holding the fixture feed the socket plate wires into the backplate center hole.
4: Make sure that the crossbar is grounded in accordance with local electrical codes.
INNER THREADED HOLE
1" APART
7: Align the backplate screw holes to the electrical box mounting holes, and place the backplate on wall to mark the anchor location.
8a: If mounting fixture centered: mark the end holes of the mounting on the wall. These marked holes are for anchors (not provided).
8b: If mounting fixture off centered: slightly loosen the two backplate screws and slide the mounting bar to the desired position and tighten the backplate screws. Mark the end holes of the mounting on the wall. These marked holes are for anchors (not provided).
5: Connect the white fixture wire to the neutral power wire with a wire nut.
6: Connect the black fixture wire to the hot power wire with a wire nut.
F
CROSSBAR
MOUNTING ADJUSTMENT BACKPLATE SCREW
8b
7
END HOLE
BAR
8a8a