Earlex LCS176, LCS270 User Manual

Page 1
OPERATING INSTRUCTIONS
Models LCS270 / LCS176
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE
Thank you for purchasing an Earlex Steam Wallpaper Stripper.
In order to obtain the best results please read the instructions before commencing
any work. Please also make a special note of the safety rules.
EARLEX LIMITED WILL
PRODUCT
IF USED FOR
ACCEPT
ANY
NO RESPONSIBILITY
OTHER PURPOSES THAN THOSE DETAILED HEREIN.
FOR
RETAIN FOR FUTURE REFERENCE
THIS
Page 2
l
Keep away from children and animals.
l
Do not pull by the mains lead or the steam hose.
l
Be careful of overhead dripping, when using on overhead areas tilt the steam plate away from the face and body, and regularly empty the steamplate of any collected condensation.
l
Do not leave unattended.
l
Do not point the steam plate at anyone.
Safety Rules
l
Always disconnect power supply when filling the machine or when not in use.
l
Do not use any caustic cleaners on the tank.
l
Do not allow to boil dry.
l
Do not overfill the reservoir. DO NOT USE ADDITIVES.
l
Never detach the hose whilst the unit is switched on.
l
Do not allow water or steam to enter light switches or sockets.
l
Always use and store upright.
l
Always visually check that the hose and steam plate inlet are not blocked before attempting to use.
l
Do not strain, kink or trap the hose under heavy objects.
l
Use only 4lb pressure cap as supplied. It is also a safety valve. NEVER BLOCK OFF THIS OUTLET.
l
NEVER remove the filler cap when unit is boiling - switch off and wait for 5 minutes.
l
Never use outside when raining.
Main Features
This is a professional, fast-action steam wallpaper stripper features;
l
Each tank is individually pressure tested.
l
Storage for the hose and the mains lead.
l
Neon mains On/Off switch,
l
Cooler running steam hose.
Caution!
Check the state of your plaster before starting work. Steam can loosen weak, porous or poorly bonded plaster - which also loosens readily if cracked, holed or if steam plate is held in one position for too long after the paper is soaked. Weak plaster can normally be detected by tapping a few areas of the wall.
. It has many added
hollow
A
l
The tank becomes hot in use. Do not touch. Only move with the carrying frame.
l
Steam is produced at 100oC. Wear protective clothing and gloves when operating this stripper
l
DO NOT USE THIS STRIPPER FOR
.
ANY OTHER PURPOSES THAN DETAILED IN THESE INSTRUCTIONS.
l
Under no cirumstances should you attempt to repair a unit unless qualified and authorised to do so.
l
Use only genuine Earlex replacement parts.
sound indicates that you should proceed only with extreme care - stopping immediately if you hear a cracking sound or plaster starts to break loose.
The steam stripper is safe for drywall/plaster board surfaces but whatever the material, it is always wise to check a small area before starting work properly.
Protect your home!
The heat generated by the boiler unit can mark carpets, soft furnishings, table tops, cabinets etc. Dust sheets or newspapers are not suitable heat protectors for delicate surfaces.
2
Page 3
Preparation
MAX
M
IN
T
o achieve fastest paper removal always gently score the areas to be stripped. With heavily embossed, vinyl coated or painted papers this is essential. Either use a proprietary perforator tool or alternatively score the paper with the edge of a wall scraper in a criss-cross pattern with 150mm (6 inch) spacing. As with all decorating work be sure to protect carpets and furniture with covers.
Operation
STEAM IS HOT! The unit is designed for safe, fast removal of wallpaper but you must be aware that steam is produced at 100oC so be careful, wear protective clothing and protect your hands with heat resistant gloves or mitts. Place the unit on a flat surface near to the area to be stripped. Remove the steam plate. FULLY UNCOIL the hose and mains lead. Connect the thread on the steam plate to the end of the hose. This only needs to be hand tight. DO NOT OVERTIGHTEN.
Connect the mains lead from the unit to the socket and switch on. The mains switch on the unit has a neon light and will light when the unit is on. It will take between 10 and 20 minutes for the 230V unit or 25-35 minutes for the 110V unit to start producing steam depending on the temperature of the water used. DO NOT LEAVE UNATTENDED. Once steam is being produced at the steam plate you are ready to commence operation. Prior to the steam being produced a small amount of bubbling will occur at the steam plate. WARNING: Beware of hot water discharge prior to steam emission. When the steam has been produced, lift the steam plate above the level of the tank outlet to allow condensed steam to run back down the hose and into the tank. If you are right handed hold the steam plate in your left hand and place flat against the wall where you wish to commence removing. Leave the plate against the wall for approximately 10 seconds. If you are left handed you may find it easier to operate with the other hand.
If the steam plate is fitted with a metal swivel joint, tighten hose nut to thread using two spanners. The plate can remain permanently attached to the hose thereafter. To fill the unit, remove the filler cap and fill to the maximum water level as shown on the glass panel at the end of the tank. This must be clean water NOT USE ADDITIVES - DO NOT OVERFILL.
, preferably hot. DO
Move the steam plate to the section immediately next to where you have just been working and use a wallpaper scraper to remove the section that has just been steamed. By working in this way you should be able to remove paper continually. You may have to leave the plate against the wall for longer periods with some papers or re-steam if not completely removed.
3
Page 4
The 230V unit will operate for approximately 1 1/2 hrs and the 1
10V unit will operate for approximately 3 1/4 hrs before requiring refilling. The water level is shown through the glass level indicator and should not be allowed to fall below minimum. Switch the unit off when this level has been reached. If you require further use of the steamer, ensure unit is switched off and has stopped boiling. Wait for 5 minutes. Slowly turn cap anti-clockwise, any remaining trapped steam will be released from beneath cap.
Caution
- steam is very hot -wear a glove and keep face clear.
Refill to the level indicator
as before and follow above instructions.
YOU MUST NEVER ALLOW THE UNIT TO BOIL DRY.
There is a safety thermal cut-out device fitted to the unit. If the unit is allowed to boil dry this will operate and prevent further use. Switch the unit off and allow it to cool for at least 5 minutes, refill with water and then switch on again - the thermal cut-out should automatically re-set. If this has not re-set allow a further cooling period. When you have finished using the unit allow any remaining water to cool and then empty the unit. We recommend flushing the tank out with clean water before storing. NEVER LEAVE WATER IN THE UNIT WHILST BEING STORED.
Storage
Brackets are fitted to the frame for the storage of the mains lead and hose. To recoil - wind the mains lead onto the brackets - then wind on the steam hose ensuring adequate length of hose is left to secure the steamplate into the clips on the opposite side. The handle should face outwards - slide the plate in until tight.
Radiator Cap
To fit - screw onto the filler neck hand tight. Do not overtighten. To remove - ensure unit is switched off and has stopped boiling. Wait for 5 minutes. Slowly unscrew the cap, any remaining trapped steam will be released from the anti-discharge valve.
Caution - steam is very hot - wear a glove and keep face clear.
Refill to the level indicator as before and follow above instructions. STEAM IS DANGEROUS.
4
Page 5
Other Uses
The stripper can also be used to:
l
Remove
l
Lift stuck down vinyl tiles.
l
Sterilise soil.
l
Kill garden weeds.
Artex
®
.
TROUBLE SHOOTING
Unit Fails to Boil
l
The thermal cut-out has operated. Switch off, allow to cool, refill with water then switch on again.
l
Check the fuse in the plug - 230V unit only.
l
If using an extension lead - check that the thermal re-set button on the extension lead has not tripped out. Check that the extension lead is rated at a minimum of
13 amps - 230V unit only. If the unit still will not operate return the unit to the dealer or authorised agent to check the thermal fuse link and element. ONLY QUALIFIED ELECTRICIANS SHOULD UNDERTAKE THIS WORK.
Unit keeps cutting out
l
Check that water is above minimum level.
l
Check that the extension lead is rated at 13 amps minimum and fully unwound. 230V unit only.
l
Check that no additives have been used.
Steam escaping from Pressure Cap
l
Check for blockages in hose or steam plate.
l
Clean seating around cap area.
Descaling
We recommend that the tank is cleaned every three months using proprietary descaling products, used as per the manufacturers instructions.
Spare Parts
The full range of spare parts is available from Earlex. Despatch is available same day by first class post to Companies with credit facilities or for payment by credit card.
IF YOU REQUIRE ANY FURTHER ASSISTANCE PLEASE CALL OUR
HELPLINE ON 01483 454666
Monday - Friday 08:30 - 18:00 (excluding Bank Holidays)
5
Page 6
Spare Parts List and Diagram
PART NO. DESCRIPTION QTY
PS 0004 Tube Connector-external....................... 4
PS 0005
PS 0006 C/sk Screw-Frame Joints...................... 8
PS 0007 Stand/Seat Moulding............................. 1
PS 0008/A Steam Tank Assembly........................... 1
PS 0019
PS 0020 ‘O’Ring for Element............................... 1
PS 0021 Stud....................................................... 2
PS 0022 Hexagon Nut......................................... 6
PS 0023 Shakeproof Washer.............................. 4
PS 0027 Cable Assembly-Switch to Cut-out....... 1
PS 0028 Cable Assembly-Switch to Element...... 1
PS 0029 Mains Cable Assy-with 13 amp Plug.... 1
PS 0032 Element Cover...................................... 1
PS 0038
PS 0042 Elbow-Steam Outlet.............................. 1
PS 0047 Steamplate Assembly (not shown)....... 1
PS 0048 Steam Plate.......................................... 1
PS 0049 Adaptor-for Hose.................................. 1
PS 0053 Circlip.................................................... 1
PS 0055 Taper Nut.............................................. 2
PS 0071 Clip for Steam Plate.............................. 2
PS 0117 ‘0’ Ring Tank Seal................................. 1
PS 0118 Gasket Tank Window............................ 1
PS 0123 Thermostat........................................... 1
PS 0124 Tank Cover - Black............................... 1
PS 0127 Lock Nut M6 ........................................ 4
PS 0128 Protective Cover M6............................. 2
PS 0134 Stainless Steam Pipe............................ 1
Tube Connector-internal........................ 2
Thermal Fuse........................................ 1
Steam Hose Assembly.......................... 1
PS 0136 Glass Window....................................... 1
PS 0137 Glass Retaining Plate........................... 1
PS 0138
PS 0139 Screw for Retaining Plate..................... 6
PS 0140
PS 0155 Cable Assembly 110V........................... 1
PS 0200 Steam Plate Buffer .............................. 1
PS 0202 Steam Plate Swivel Joint...................... 1
PS 0302
PS 0296 Short Stud for Earth Connection........... 1
PS 0301 Anti-discharge Valve (not shown).......... 1
PS 0303 Pressure Cap Assembly-with Chain..... 1
PS 0316 Heat Shield ............................................1
PS 0317 Heating Element 2750W....................... 1
PS 0321 Heating Element 1760W....................... 1
PS 3000 Side Frame left hand............................ 1
PS 3001 Side Frame right hand.......................... 1
PS 3003 Handle tube........................................... 1
PS 3004 Hose/CableClip...................................... 2
PS 3005 Spacer Tank Mounting........................... 4
PS 3006 C/sk Screw for Clip................................ 2
PS 3014 PVC Handle........................................... 1
PS 3037 Foot Moulding........................................ 4
Level Indicator Ball............................... 1
Screw for Tank Joint............................. 3
Switch Assy-mains with indicator.......... 1
6
Page 7
PS3004
PS3014
PS0055
PS0005
PS0004
PS0006
PS3037
PS0200
PS0134
PS0048
PS0303/0315
PS0138
PS0137
PS0139
PS0136
PS0118
PS0019
PS0123
PS0006
PS0117
PS0020
PS0008/A
PS0140
PS0042
PS0053
PS0049
PS0038
PS0202
PS0317 2750W x 230V
PS0321 1760 x 110V
PS0296
PS0023
PS0021
PS0022
PS0316
PS0032
PS0027
PS0302
PS0128
PS0127
PS0028
PS0029 UK
PS0124 BLACK
MIN
M
A
X
PS0022
PS0071
PS0004
PS0006
PS3006
PS3003
PS3001
PS3000
PS3005
PS0155 110V
7
Page 8
Mains connection 230V UK only
The stripper is supplied fitted with a 13 amp plug top and fuse. If a replacement fuse is required this must be rated at 13 amps. If in doubt consult an electrician. WARNING - THIS APPLIANCE MUST BE: EAR
THED. For your total protection it is recommended that a residual current circuit breaker (RCCB) should be used in conjunction with the stripper; Min. 15 amp ­Max. 20 amp. If any eletrical component is damaged or faulty, it must be replaced by the manufacturer or it’s appointed service agent or a similarly qualified person in order to avoid a hazard. As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
l
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol, or coloured green or green and yellow.
l
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
l
The wire which is coloured brown must be
connected to the terminal which is marked with the letter
L or coloured red.
Mains connection 110V UK only
The stripper is fitted with a 16 amp industrial plug for insertion into a suitable transformer or generator supplying 1
10V a.c. outlet. If this mains cable becomes damaged it should be replaced with our Part No. PS0155.
Extension Leads 230V
If you are using an extension lead it must be rated at a fully unwound. Do not operate with a lead rated at less than 13 amps as this will cause premature failure of the element which is not covered by guarantee.
minimum of 13 amps and
EC Declaration of Conformity We declare that the units: LCS conform to: 73/23/EEC, BSEN60335-2-15 & 89/336/EEC, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3
Tim Hopper -Technical Director
GUARANTEE
This product is guaranteed for a period of 2 years for ordinary use and 1 year for hire purposes or where the unit is lent to other users. materials or workmanship. Whilst every possible care is taken by Earlex to ensure that our products leave the factory in good working order Earlex cannot under any circumstances accept liability for problems or damage caused by their subsequent use. It is the responsibility of the user to ensure that surfaces to be treated, cleaned or stripped are suitable for steam. This guarantee does not af In the event of a fault occuring please contact our helpline before returning the unit to our Service Department at the address below together with a copy of your purchase receipt. All repairs will be dealt with speedily. If the guarantee card is not returned within 14 days from the date of purchase the guarantee is limited to date of product manufacture.
© Earlex Limited 2004
The tank is guaranteed against corrosion for 3 years.
fect your statutory rights.
Earlex Limited,
Moorfield Road, Slyfield Industrial Estate, Guildford, Surrey GU1 1RU. UK.
Tel: 01483 454666 Fax: 01483 454548
E-mail: enquiries@earlex.co.uk
Website: www.earlex.co.uk
8
The guarantee is against faulty
PS3031 01/04
,
Loading...