DYNEX NDF65316, NDF65310, NDF65314 Datasheet

NDF653
NDF653
Fast Recovery Diode
Replaces March 1998 version, DS4203 - 3.0 DS4203-4.0 January 2000
APPLICATIONS
Induction Heating
A.C. Motor Drives
Inverters And Choppers
Welding
High Frequency Rectification
FEATURES
Double Side Cooling
High Surge Capability
Low Recovery Charge
VOLTAGE RATINGS
Type Number Repetitive Peak
Reverse Voltage
V
RRM
V
NDF653 16 NDF653 14 NDF653 12 NDF653 10
1600 1400 1200 1000
Conditions
= V
V
RSM
RRM
+ 100V
KEY PARAMETERS
V I
F(AV)
I
FSM
Q t
rr
RRM
r
1600V
660A
6500A
45µC
1.4µs
See Package Details for further information.
CURRENT RATINGS
Symbol Parameter Conditions
Double Side Cooled
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Single Side Cooled (Anode side)
I
F(AV)
I
F(RMS)
I
F
Mean forward current
RMS value
Continuous (direct) forward current
Half wave resistive load, T
= 65oC 1030 A
T
case
T
= 65oC 870 A
case
Half wave resistive load, T
T
= 65oC 770 A
case
T
= 65oC 625 A
case
Outline type code: CB479.
= 65oC 660 A
case
= 65oC 490 A
case
UnitsMax.
1/7
NDF653
SURGE RATINGS
ParameterSymbol
FSM
FSM
Surge (non-repetitive) forward currentI
Surge (non-repetitive) forward currentI
THERMAL AND MECHANICAL DATA
Symbol
R
th(j-c)
R
th(c-h)
Thermal resistance - junction to case
Thermal resistance - case to heatsink
Parameter
Conditions
10ms half sine; with 0% V
10ms half sine; with 50% V
Conditions Max. Units
Double side cooled
Single side cooled
Clamping force 10kN with mounting compound
= 125oC
RRM, Tj
= 125oC
RRM, Tj
Min.
dc
- 0.03
Cathode dc - 0.063 Double side
Single side
-
- 0.02oC/W
Max. Units
6.5 kA
211 x 10
3
5.2 kA
13.52 x 103A2sI2t for fusingI2t
0.01
A2sI2t for fusingI2t
o
C/W
o
C/W- 0.058Anode dc
o
C/W
o
C/W
T
T
stg
Virtual junction temperature
vj
Storage temperature range -55 175
On-state (conducting) - 125
11.09.0Clamping force-
CHARACTERISTICS
Symbol Typ. Units
V
FM
I
RRM
t
rr
Q
RA1
I
RM
K
V
TO
Forward voltage
Peak reverse current Reverse recovery time
Recovered charge (50% chord) Reverse recovery current
Soft factor
Threshold voltage
Parameter
Conditions Max.
At 450A peak, T At V
, T
RRM
case
= 25oC - 2.65 V
case
= 125oC-mA
- 1.4
= 500A, diRR/dt = -80A/µs
I
F
T
= 125oC, VR = 100V
case
-45µC
-60A
1.8 - -
At T
= 125oC - 1.7 V
vj
100
o
o
kN
µs
C C
2/7
r
T
V
FRM
Slope resistance
At Tvj = 125oC - 1.7 m
Forward recovery voltage di/dt = 1000A/µs, Tj = 125oC--V
NDF653
DEFINITION OF K FACTOR AND Q
Q
= 0.5x IRR(t1 + t2)
RA1
dIR/dt
0.5x I
t
1
RR
I
RR
k = t
t
2
1/t2
CURVES
3500
3000
Measured under pulse conditions
RA1
τ
- (A)
2500
F
2000
Tj = 125˚C
Tj = 25˚C
1500
Instantaneous forward current I
1000
500
1.0 2.0 3.0 4.0 5.0 Instantaneous forward voltage V
- (V)
F
Fig.1 Maximum (limit) forward characteristics