Dynalco SPD-100L User Manual

SPD -100 and SPD-100L
Signal-Powered Tachometer
Calibration Instructions
The SPD-100 and SPD-100L tachometers are normally factory­calibrated to the customer-specified number of sensing teeth or
discontinuities, sensing speed, and desired numerical display.
If necessary, turn to the reverse side of this card to calculate Signal Frequency and Gate Time.
1. Remove the sealing plug on the back of the housing.
2. Apply the calculated signal frequency to terminals 1 and 2.
A Dynalco F-16 or F-15 signal generator is ideal.
3. Select the appropriate gate time range on the 4-position switch.
reverse side of card.
4. Adjust the vernier potentiometer for the desired display.
See below
See label on back of SPD-100 or SPD-100L; or Item 3,
.
Shown with sealing plug removed
4-position switch
Vernier potentiometer
[clockwise to increase display reading; counterclockwise to decrease]
Example:
1.Apply 3390 Hz to terminals 1 and 2 on tachometer (no polarity).
2.Turn the gate time range switch to (either) position number 1 to
select gate time range of 0.26–0.72 seconds.
3.Adjust the vernier potentiometer to obtain a display of 1800.
If 3390 Hz = 1800 RPM, then gate time is 0.53 seconds.
See label on back of SPD-108, SPD-108L for additional information
QUICK
GATE TIME
CALCULATION
(
For example: 60/113 teeth = 0.53 sec. gate time)
© 2002 Dynalco Controls 145F-12040, Rev. 0
}
60
Number of
Teeth
Assumes the pickup is “seeing” the gear of interest directly, not through
{
a step up or step down ratio
.
1. Calculating Signal Frequency (in Hz)
Multiply RPM times the number of teeth (or discontinuities), then divide by 60. For example, sensing a ring gear with 1 13 teeth rotating at 1800 RPM gives a frequency of 3390 Hz.
Signal Frequency in Hz =
Signal Frequency in Hz = = 3390 Hz
(RPM) x (Teeth or Discontinuities) 60
(1800 RPM) x (113 Teeth) 60
2. Calculating Gate Time (In seconds)
Divide the number to be displayed on the SPD-100 or SPD-100L by the corresponding signal frequency.
Gate Time = = 0.53 seconds
.
1800 RPM 3390 Hz
3. Gate Time Range Selection on 4-Position Switch
Select either position for each number pair on the switch:
Position 1: 0.26–0.72 sec. Position 2: 0.72–1.43 sec. Position 3: 1.43–2.85 sec. Position 4: 2.85–5.70 sec.
Optional Calibration Method: On-engine
A. Select the appropriate gate time range on the 4-position switch. B. Connect the magnetic pickup output to terminals 1 & 2. C. Adjust vernier potentiometer on SPD-100 or SPD-100L until its
display agrees with another precise digital tachometer.
OUTLINE AND CONNECTION DRAWING
inches (cm)
DYNALCO CONTROLS RESERVES THE RIGHT TO CHANGE THESE SPECIFICATIONS WITHOUT NOTICE.
Dynalco Controls, 3690 N.W. 53rd Street, Fort Lauderdale, FL 33309 U.S.A.
(954) 739- 4300 • Fax (954) 484-3376 • www.dynalco.com • mailbox@dynalco.com
SPD-100, SPD-100L, F-15, and F-16 are trademarks of Dynalco Controls.
Loading...