Dwyer DBT User Manual

Bulletin T-DBT
3 13/16 [97.00]
1/2 NPT
STEM
LENGTH
ø1/4
[ø6.35]
ø2-1/4
[ø82.55]
Series DBT Digital Solar-Powered Bimetal Thermometer
Specifications - Installation and Operating Instructions
The Series DBT Digital Solar-Powered Bimetal Ther­mometer takes the guesswork out of temperature mea-
surement. The 3-1/2 digit LED display is easy to read and provides resolution to 0.1°F. The adjustable angle can be mounted in virtually any position. The engineering units can be selected in the field by removing the back cover.
Operation
Series DBT thermometers are solar powered and are con­tinuously operating. Series DBT thermometers must be used in environments where there is adequate light available to power the unit. To obtain a temperature reading on the Series DBT, simply insert the stem of the thermometer into the process being measured. Thermowells are recommended in all high pressure, flow, and corrosive media applications. Thermowells protect the Series DBT thermometer from damage and premature fail­ure. Additionally, thermowells allow for easy removal of the DBT draining the process media.
Unit Selection
The Series DBT allows users to field select the readings to be measured in ˚F or ˚C. Remove the rubber cap on the rear of the unit. The unit switch will be to the right for ˚F and to the left for ˚C. Refer to Figure A.
SPECIFICATIONS Range: 14 to 302°F (-10-150°C). Wetted Materials: 304 SS. Lens: Acrylic. Accuracy: 32 to 122°F (0 to 50°C): ±1°C. Dial Size: Connection: 1/2˝ NPT-Adjustable Angle. Display: 3-1/2 Digit LCD. Response Time: 15 seconds. Supply Power: 3-Volt Solar Cell (minimum 35 LUX
required). Weight: 12 oz (350 g).
UNIT SELECTION SWITCH
FACTORY RESET BUTTON
REAR VIEW
CALIBRATION ADJUSTMENT POTENTIOMETER
Figure A.
©Copyright 2007 Dwyer Instruments, Inc. Printed in U.S.A. 12/07 FR# R7-443591-00
DWYER INSTRUMENTS, INC.
P.O. Box 373 • Michigan City, IN 46361-0373, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Phone: 219/879-8000 www.dwyer-inst.com
Loading...