Duracell Ultra CR-V3 User Manual

Ultra CR-V3
6-Volt 3.3
Megapixel
Camera
3-Volt 2.1
Megapixel
Camera
60 Pictures per hour, 33% LCD Duty Cycle,
50% flash
60 Pictures per hour, 33% LCD
Duty Cycle, 50%
flash
35mm Point and
Shoot Camera
35mm SLR Photo
1.8A, 3 sec on 7 sec off, cont. to 2.0V @ 20 C
1.2A, 3 sec on 7 sec off, cont. to 1.7V @ 20 C
Delivered Energy vs. Power Drain
at Various cut-off Voltage
Room Temperature
Power (W)
Energy (Wh)
Lithium/Manganese Dioxide
R 7.25 [0.285] Max
12.5 [0.49]
0.90
0.70
0.035
0.028
52.20
51.60
2.055
2.031
φ
6.5 [0.26]
Units: MM
14.1 [0.55]
28.60
28.20
1.126
1.110
14.60
14.20
0.575
0.559
Nominal Internal Impedance:
3.0 V
3.1-3.3 V
0.5 ohm @ 1kHz
Average Weight: 39 g Volume: 21.9 cm.
Terminals: Operating Temp.
Range:
Flat, Recessed Terminal Nickel Plated Steel
-20°C to 60°C (-4°F to 140°F)
NEDA/ANSI: 5047 IEC: TBD
Delivered Energy vs. Power Drain
at Various cut-off Voltage
10
5
Energy (Wh)
3
Room Temperature
Li/MnO2
2.2V
2.0V
1.8V
35mm SLR Photo
1.8A, 3 sec on 7 sec off, cont. to 2.0V @ 20 C
35mm Point and
Shoot Camera
1.2A, 3 sec on 7 sec off, cont. to 1.7V @ 20 C
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
3
12 34
Duracell Ultra CR-V3 Typical Performance
3-Volt 2.1
Megapixel
Camera
60 Pictures per hour, 33% LCD Duty Cycle,
50% flash
6-Volt 3.3
Megapixel
Camera
60 Pictures per hour, 33% LCD
Duty Cycle, 50%
flash
1000 2000 3000
Pulse count
Power (W)
Test Regime
1. LCD on 2 minutes,
2. While LCD on, take 6 pic. each 20 sec.
3. LCD off 4 minutes
4. Repeat steps 2 & 3 consecutively 10 times,
5. Camera off for 4 hours,
6. Repeat all steps continuously until battery fails
5
0001006002
Pulse count
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Ultra CR-V3
Lithium/Manganese Dioxide
1.8 Amp, 3 Sec on / 7 sec off at Various Temperatures
3.5
3
2.5
2
Battery Voltage (V)
1.5
1
0 1000 2000 3000
Pulses
RT
-10
-20
Li/MnO2
O
°C °C
°C
3.5
3
2.5
2
Battery Voltage (V)
1.5
1
0 500 1000 1500 2000
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
1.2 Amp, 3 Sec On / 7 Sec off at Various Temperatures
RT
°C
0
°C
-10
Pulses
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08