Duracell Ultra 245 User Manual

16.4
15.6
34.0
32.5
Ultra 245
Lithium/Manganese Dioxide
Li/MnO2
Nominal Voltage: 6 V
C
L
17.0 mm
16.0
mm
mm
Typical Voltage: 6.4-6.6 V Nominal Internal
Impedance: Average Weight: 38.6 gm Typical Volume: 24.1 cm
Terminals:
Operating Temperature Range:
ANSI: IEC:
0.45 ohm @ 1kHz
Flat, Recessed Contacts Nickel Plated Steel
-20oC to 75oC
o
F to 167oF)
(-4 5032LC
2CR5
3
45.0 mm
43.0
Duracell Ultra 245 Typical Performance
35mm Point &
Shoot Camera
1.2A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C
10
Energy (Wh)
4
0.1
Delivered Energy vs. Power Drain
@ Various Cutoff Voltage - Room Temperature
3.6 V
4.0 V
4.4 V
Power (W)
1
4
35mm SLR Photo
1.8A, 3 sec on 7sec off, cont. to 3.6 V @ 20°C
0.9A, 3 sec on 27sec off, cont.
Photo
to 3.6 V @ 20°C
0 500 1000 1500 2000
Pulse Cycles
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Ultra 245
3
4
5
6
7
0.1 1
10
100
1000
Service (Hours)
Voltage (V)
10 mA
50 mA
100 mA
250 mA
500 mA
750 mA
1000 mA
Lithium/Manganese Dioxide
0.9 Amp, 3 sec on/27 sec off @ Various Temperatures
-20C
-10C
5
4
Battery Voltage (V)
3
0 400 800 1200 1600 2000
Pulses
RT
Continuous Discharge
RT to 3.4 Volts
5
4
Battery Voltage (V)
3
Li/MnO2
1.8 Amp 3 sec on/ 7 sec off
@ Various Temperatures
-10C RT
0090060030
Pulses
Voltage (V)
1000 mA
0.1
500 mA
750 mA
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.
100 mA
250 mA
Service (Hours)
10
50 mA
10 mA
100
1000
5
4
Battery Voltage (V)
3
Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
1.2 Amp, 3 sec on/ 7 sec off @ Various Temperatures
-20C
-10C RT
00210080040
Pulses
6/08