36.0
34.5
mm
( + )
16.8 mm
REF.
35.0
mm
32.5
( – )
19.5
18.5
mm
Lithium/Manganese Dioxide
Nominal Voltage: 6 V
Typical Voltage: 6.4-6.6 V
Nominal Internal
Impedance:
Average Weight: 38 gm
Typical Volume: 22.6 cm
Terminals:
Operating Temperature
Range:
NEDA/ANSI:
IEC:
Delivered Energy vs. Power Drain
@ Various Cutoff Voltage - Room Temperature
10
0.4 ohm @ 1kHz
Flat, Recessed Contacts
Nickel Plated Steel
-20oC to 75oC
(-4
5024LC
CR-P2
Ultra 223
3
o
F to 167oF)
3.6 V
4.0 V
4.4 V
Li/MnO2
Dimensions shown are IEC/ANSI standards
35mm Point &
Shoot Camera
1.2A, 3 sec on 7sec off, cont.
to 3.6 V @ 20°C
35mm SLR Photo
1.8A, 3 sec on 7sec off, cont.
to 3.6 V @ 20°C
0.9A, 3 sec on 27sec off, cont.
Photo
to 3.6 V @ 20°C
0 500 1000 1500 2000
Energy (Wh)
4
0.2
Power (W)
Duracell Ultra 223 Typical Performance
Pulse Cycles
1
4
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Ultra 223
Lithium/Manganese Dioxide
5.4
5
4.6
4.2
3.8
Battery Voltage (V)
3.4
3
7
6
1.2 Amp, 3 sec on/ 7 sec off
@ Various Temperatures
Pulses
Continuous Discharge
RT to 3.4 Volts
-20C
-10C
RT
00210080040
10 mA
50 mA
100 mA
250 mA
500 mA
750 mA
1000 mA
5.4
5
4.6
4.2
3.8
Battery Voltage (V)
3.4
3
Li/MnO2
1.8 Amp 3 sec on/ 7 sec off
@ Various Temperatures
-10C
RT
0080060040020
Pulses
5
Voltage (V)
4
3
00010010111.0
Service (Hours)
5.4
5
4.6
4.2
3.8
Battery Voltage (V)
3.4
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park
Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
3
0 400 800 1200 1600 2000
Internet: www.Internet: www.duracellduracell .com.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
0.9 Amp, 3 sec on/27 sec off
@ Various Temperatures
-20C
-10C
RT
Pulses
6/08