PC1604
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Size: 9V (6LR61)
Alkaline-Manganese Dioxide Battery
Zn/MnO2
( – ) ( + )
17.5
15.5
12.95
12.45
26.5
24.5
46.4 mm
MAX.
mm
mm
mm
48.5
46.5
mm
Nominal Voltage:
Operating Voltage:
Impedance:
9 V
9.6 - 4.8 V
1,700 m-ohm @ 1kHz
Typical Weight: 45 gm (1.6 oz.)
Typical Volume: 22.8 cm
3
Terminals: Miniature Snap
Storage Temperature
Range:
Operating Temperature
Range:
ANSI:
IEC:
-20oC to 35oC
-20oC to 54oC
(-4oF to 130oF)
1604A
6LR61
(1.4 in.3)
Dimensions shown are IEC/ANSI standards
Berkshire Corporate Park
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.
duracell
.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
PC1604_US_PC.PDF
Page 1 of 2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70° F)
9.5
8.5
7.5
Voltage
6.5
5.5
4.5
0 102030405060708090100
Service Hours
100 OHM
200 OHM
500 OHM
1000 OHM
8/06
1000
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
100
Service Hours
10
TYPICAL CONSTANT CURRENT DISCHARGE
CHARACTERISTICS AT 21°C (70°F)
7.0 V
6.0 V
5.4 V
4.8 V
PC1604
Size: 9V (6LR61)
Alkaline-Manganese Dioxide Battery
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
10
9
8
7
Voltage
6
5
Zn/MnO2
50 mA
10 mA
2 mA
1
1 10 100
Discharge Current (mA)
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
9.5
8.5
7.5
Voltage
6.5
5.5
4.5
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Amp Hours
1000 mW
500 mW
250 mW
100 mW
10 mW
4
0 50 100 150 200 250 300 350 400
Service Hours
TYPICAL TOY TEST
9.5
9
8.5
8
7.5
7
Voltage
6.5
6
5.5
5
4.5
0 5 10 15 20 25
AT 21°C AND 0°C
Service Hours
0°C
RT
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
PC1604_US_PC.PDF
Page 2 of 2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Berkshire Corporate Park
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454
Internet: www.
duracell
.com
8/06