Duracell MX2400 User Manual

MX2400
Size: AAA (LR03)
3.8 mm Max
( + )
10.5
9.5
0.8 mm MIN.
44.5
43.5
mm
mm
Alkaline-Manganese Dioxide Battery
Nominal Voltage:
Operating Voltage
Impedance: Typical Weight: 11 gm (0.4 oz.)
Typical Volume: 3.5 cm Terminals:
Storage Temperature Range:
Operating Temperature Range:
ANSI: IEC:
1.5 V
1.6 - 0.75V
114 m-ohm @ 1kHz
3
Flat
-20oC to 35
-20oC to 54oC (-4oF to 130oF)
24A LR03
(0.2 in.3)
o
C
)
(
Dimensions shown are ANSI standards
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
TYPICAL DISCHARGE CHARACTERISTICS AT VARIOUS POWER DRAINS
TYPICAL DISCHARGE CHARACTERISTICS AT VARIOUS POWER DRAINS
1.5
1.4
1.3
1.2
Voltage
1.1
1.0
0.9
0.8 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5
Service Hours
Temp: 21°C (70°F)
1.00 W
0.75 W
0.50 W
0.25 W
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
MX2400
Size: AAA (LR03)
TYPICAL DELIVERED ENERGY VS POWER DRAIN
2.0
1.0
Energy (Wh)
0.1
Power (mW)
TYPICAL DELIVERED CAPACITY VS POWER DRAIN
2.0
1.0
1.1 V
1.0 V
0.9 V
1.1 V
1.0 V
0.9 V
Alkaline-Manganese Dioxide Battery
TYPICAL SERVICE HOURS VS POWER DRAIN
1000
1.1 V
1.0 V
100
0001001015
10
Service Hours
1.0
0.1
Power (mW)
0.9 V
0001001015
Amp Hours
0.1
Power (mW)
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
1.8
1.6
1.4
0001001015
1.2 1
0.8
0.6
Closed Circuit Voltage
0.4
0.2 0
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
TYPICAL DC RESISTANCE CHARACTERISTICS
Low drain: 0.06A/1hr - 0.3A/1sec
High drain: 0.6A/5min - 1.2A/1sec
Low drain
High drain
Low drain
High drain
Depth of Discharge
o
All testing at 21 C (70 F)
o
1.8
1.6
1.4
1.2 1
0.8
0.6
0.4
0.2 0
DC Resistance
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Loading...