Duracell MX1500 User Manual

MX1500
Size: AA (LR6)
5.5 mm
Max.
14.5
13.5
1.0 mm MIN.
50.5
49.5
mm
mm
Alkaline-Manganese Dioxide Battery
Nominal Voltage:
Operating Voltage
Impedance: Typical Weight: 24 gm (0.8 oz.)
Typical Volume: 8.4 cm Terminals: Flat
Storage Temperature Range:
Operating Temperature Range:
ANSI: IEC:
1.5 V
1.6 - 0.75V
81 m-ohm @ 1kHz
3
-20oC to 35
-20oC to 54oC (-4oF to 130oF)
15A LR6
(0.5 in.3)
o
C
Zn/MnO2
( )
Dimensions shown are ANSI standards
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
TYPICAL DISCHARGE CHARACTERISTICS AT VARIOUS POWER DRAINS
1.6
1.5
1.4
1.3
1.2
Voltage
1.1
1.0
0.9
0.8 024681012
Service Hours
All testing at 21 C (70 F)
1.00 W
0.75 W
0.50 W
0.25 W
o
o
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
MX1500
Size: AA (LR6)
TYPICAL DELIVERED ENERGY VS POWER DRAIN
0.5
1.0
Energy (Wh)
0.5
Power (mW)
TYPICAL DELIVERED CAPACITY VS POWER DRAIN
5.0
1.1 V
1.0 V
0.9 V
1.1 V
1.0 V
0.9 V
Alkaline-Manganese Dioxide Battery
TYPICAL SERVICE HOURS VS POWER DRAIN
1000
100
0001001015
10
Service Hours
1
0.1
Power (mW)
Zn/MnO2
1.1 V
1.0 V
0.9 V
0001001011
Amp Hours
1.0
0.5
Power (mW)
Berkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800Telephone: Toll-free 1-800Telephone: Toll-free 1-800-544-5454Telephone: Toll-free 1-800-544-5454
Internet: www.Internet: www.duracellduracell .com.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
1.8
1.6
0001001015
1.4
1.2 1
0.8
0.6
Closed Circuit Voltage
0.4
0.2 0
TYPICAL DC RESISTANCE CHARACTERISTICS AT 21°C (70°F)
High drain: 1A/5 min - 2A/1sec
Low drain: 0.1A/1hour - 0.5A/1sec
Low drain
High drain
Low drain
High drain
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Depth of Discharge
o
All testing at 21 C (70 F)
o
1.8
1.6
1.4
1.2 1
0.8
0.6
0.4
0.2 0
DC Resistance
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
6/08
Loading...