Duracell MN21 User Manual

Alkaline-Manganese Dioxide Battery
MN21
10.30
9.70
5.63
5.38
0.30
0.20
mm
mm
mm
FLAT CONTACT TERMINAL
( + )
28.50
27.50
( – )
5.63
5.38
RECESSED FLAT CONTACT TERMINAL
0.58
0.43
mm
mm
mm
Nominal Voltage: 12.0 V Nominal Internal
Impedance:
22 ohm @ 1kHz
3
Average Volume: 2.3 cm
(0.14 in.3)
Terminals: Flat
o
Operating Temperature Range:
NEDA: IEC/ANSI:
C to 54oC
-20
o
(-4
F to 130oF)
1811A
-
Zn/MnO2
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
13
12
11
10
9
Voltage (v)
8
7
6
0 20 40 60 80 100 120 140 160 180
10K ohm = 0.96 mA 20K ohm = 0.52 mA 46K ohm = 0.22 mA
Berkshire Corporate Park Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com
Service Hours
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
*
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
This data is subject to change. Performance information is typical. Contact Duracell for the latest information