Duracell MN 1604 User Manual

MN1604
Berkshire Corporate Park
Berkshire Corporate Park Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454
Internet: www.
duracell
.com
Size: 9V (6LR61)
Alkaline-Manganese Dioxide Battery
Zn/MnO2
( – ) ( + )
17.5
15.5
12.95
12.45
26.5
24.5
46.4 mm MAX.
48.5
46.5
Nominal Voltage:
Operating Voltage:
Impedance:
9 V
9.6 - 4.8 V
1,700 m-ohm @ 1kHz
Typical Weight: 45 gm (1.6 oz.) Typical Volume: 22.8 cm
3
Terminals: Miniature Snap
Storage Temperature Range:
Operating Temperature Range:
ANSI: IEC:
-20oC to 35oC
-20oC to 54oC (-4oF to 130oF)
1604A 6LR61
(1.4 in.3)
Dimensions shown are IEC/ANSI standards
Berkshire Corporate Park
Berkshire Corporate Park
Bethel, CT 06801 U.S.A.
Bethel, CT 06801 U.S.A. Telephone: Toll-free 1-800-544-5454
Internet: www.
duracell
.com
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
MN1604_US_CT.PDF Page 1 of 2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
TYPICAL DISCHARGE CHARACTERISTICS AT 21° C (70° F)
9.5
8.5
7.5
Voltage
6.5
5.5
4.5 0 102030405060708090100
Service Hours
100 OHM 200 OHM 500 OHM 1000 OHM
6/08
1000
100
Service Hours
10
TYPICAL CONSTANT CURRENT DISCHARGE CHARACTERISTICS AT 21°C (70°F)
7.0 V
6.0 V
5.4 V
4.8 V
MN1604
Size: 9V (6LR61)
Alkaline-Manganese Dioxide Battery
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
10
9
8
7
Voltage
6
5
Zn/MnO2
50 mA 10 mA
2 mA
1
Discharge Current (mA)
TYPICAL DISCHARGE CHARACTERISTICS AT 21°C (70°F)
9.5
8.5
7.5
Voltage
6.5
5.5
4.5 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Amp Hours
1000 mW 500 mW 250 mW 100 mW 10 mW
001011
4
0 50 100 150 200 250 300 350 400
Service Hours
TYPICAL TOY TEST
9.5 9
8.5 8
7.5 7
Voltage
6.5 6
5.5 5
4.5
0 5 10 15 20 25
A T 21°C AND 0°C
Service Hours
0°C
RT
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
**
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
MN1604_US_CT.PDF Page 2 of 2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Berkshire Corporate ParkBerkshire Corporate Park Bethel, CT 06801 U.S.A.Bethel, CT 06801 U.S.A.
Telephone: Toll-free 1-800-544-5454 Internet: www.duracell.com
6/08
Loading...