DUCATI CTR17 User Manual

MANUALE D’ISTRUZIONI
INSTRUCTIONS MANUAL
MANUEL D’EMPLOI
1
ITALIANO 3 ENGLISH 17 FRANCAIS 31
La casa costruttrice si riserva il diritto di apportare modifiche o miglioramenti al prodotto senza preavviso. Eventuali errori riscontrati nella presente edizione saranno corretti nella prossima.
The manufacturer reserves the right to modify or improve the product without prior notice. Any inaccuracies or errors found in this manual will be corrected in the next edition.
Le constructeur se réserve le droit d’apporter des modifications ou des améliorations au produit sans aucun préavis. Les éventuelles imprécisions ou erreurs trouvées dans cette édition seront corrigées dans la prochaine édition.
Man. V1.0 22-02-2001
2
INDICE GENERALE
ITALIANO
A Destinazione dell’apparecchiatura……….. B Limitazioni d’uso…………………………….. C Installazione…………………………………...
D Funzionamento……………………………….
D.1 Comandi…………………………………………………….. 5 D.2 Dispositivi di sicurezza…………………………………….. 5 D.3 Uscite………………………………………………………... 6 D.4 Alimentazioni………………………………………………... 6 D.5 Ingressi / uscite accessorie……………………………….. 6 D.6 Segnalazioni ottiche………………………………………... 6 D.7 Temporizzatori……………………………………………… 7 D.8 Selezione programmi………………………………………. 7 D.9 Fusibili di protezione……………………………………….. 7 D.10 Caratteristiche tecniche……………………………………. 8 D.11 Logica di funzionamento…………………………………... 9 D.12 Caratteristiche elettriche e meccaniche………………….. 11 D.13 Collegamenti elettrici………………………………………. 11
4
E Manutenzione…………………………………
14
4
5
5
F Dichiarazione di conformità……………….. G Programmazione scheda…………………... H Schema generale……………………………..
14
15
16
3
ITALIANO
A) Destinazione dell’apparecchiatura
Quadro elettronico adibito al comando di 1 o 2 motori asincroni monofase alimentati a 230 vac destinato all’automazione di un cancello ad 1 o 2 ante battenti.
B) Limitazioni d’uso
Attenzione : Prima di mettere in servizio l’apparato elettronico assicurarsi che siano state rispettate le note di seguito riportate. Nota 1 - Leggere attentamente e per intero la documentazione tecnica di costruzione.
Nota 2 - L’apparecchio elettronico deve essere installato solamente da personale qualificato che abbia i necessari requisiti tecnici e professionali. Nota 3 - La tensione di alimentazione dell’apparato deve essere pari a 230 Vac +/- 10%. Nota 4 - Il polo N (neutro) della tensione di alimentazione di rete deve essere equipotenziale con la terra. Nota 5 - Devono necessariamente essere rispettate tutte le norme di sicurezza relative all’installazione di apparati elettrici ed elettronici. Nota 6 - La tensione di alimentazione di rete deve necessariamente essere fornita tramite un efficiente interruttore differenziale collaudato e tarato in
Nota 7 - Prima di installare l’apparato elettronico assicurarsi che i motori ad esso collegati, una volta alimentati con tensione di rete ed avviati, non
Nota 8 - L’apparecchiatura deve essere destinata solamente all’uso per il quale è stata espressamente concepita (vedi punto A). Ogni altro uso è da Nota 9 - Prima di agire sull’apparato elettronico, all’interno del contenitore in cui e’ alloggiato, assicurarsi che non sia presente la tensione di
alimentazione di rete.
Nota 10 - Non agire sull’apparecchiatura con mani o piedi bagnati o umidi. Nota 11 - Non lasciare esposto l’apparecchio ad agenti atmosferici (pioggia,neve ecc.). Nota 12 - Non permettere che l’apparato sia manipolato da bambini o da incapaci. Nota 13 - L’apparato elettronico deve essere alloggiato nell’apposito contenitore. Nota 14 - Il materiale plastico utilizzato per la costruzione del contenitore non e’ autoestinguente. É necessario, pertanto, installare il medesimo in
luogo ben ventilato e lontano da elementi che possono originare fiamme.
Nota 15 - La manutenzione ordinaria dell’apparecchiatura deve essere eseguita solamente da personale qualificato ogni 6 mesi. Attenzione : Il mancato rispetto delle note sopradescritte può causare danni a persone, animali o cose, nei confronti dei quali il costruttore
base alle normative previste. producano sul cancello una spinta superiore a quella prevista dalle norme e comunque tale da non recare danni in caso di urto contro cose,
persone o animali. considerarsi improprio e quindi pericoloso.
non può essere considerato responsabile.
4
ITALIANO
C) Installazione
1) Dopo aver tolto il coperchio svitando le apposite viti assicurarsi dell’ integrità dell’apparato elettronico. In caso di dubbio non mettere in servizio l’apparecchiatura e rivolgersi a personale professionalmente qualificato. Gli elementi accessori del contenitore (viti, guarnizione, passacavi) non devono essere lasciati alla portata dei bambini in quanto potenziali fonti di pericolo.
2) Assicurarsi che l’apparato elettronico sia fissato correttamente al contenitore. In caso contrario avvitare le viti allentate oppure aggiungere le viti mancanti.
3) Posizionare l’apparecchiatura in prossimità del cancello, in modo tale da ridurre al minimo la lunghezza dei fili di collegamento al resto dell’impianto.
Attenzione : Per un corretto funzionamento dell’apparecchiatura la lunghezza dei fili ad essa collegati non deve essere superiore a
10 metri.
4) Per una maggiore protezione dagli agenti atmosferici si consiglia di posizionare l’apparato sotto un tetto oppure, meglio ancora, in un vano che dispone anche di due pareti laterali. E’ opportuno inoltre, dove possibile, installare l’apparecchiatura ad un’altezza non inferiore ad 1,5 metri per evitare che possa essere manipolata da bambini.
5) Prima di procedere al fissaggio orientare il contenitore in modo tale che la parete contenente i passacavi sia rivolta verso terra.
Attenzione : Non fissare il contenitore su superfici in legno .
6) Inserire la guarnizione fornita in dotazione nell’apposita sede avendo cura che le due estremità si congiungano nella posizione centrale della parete contenente i passacavi.
7) Estrarre la parte mobile della morsettiera e procedere al collegamento dei fili relativi all’impianto come indicato nei paragrafi successivi.
D) Funzionamento
1) Definizione comandi
Start
Ingresso che fa capo ad un pulsante esterno all’apparato che serve a richiedere l’apertura o la chiusura del cancello (entrambe le ante). A questo ingresso viene solitamente collegato un pulsante a chiave.
Start pedonale
Ingresso che fa capo ad un pulsante esterno all’apparato che serve a richiedere l’apertura o la chiusura di una sola anta del cancello (anta pedonale) onde consentire il passaggio solamente a persone o animali .
2) Definizione dispositivi di sicurezza
Stop
Ingresso che fa capo ad un pulsante o interruttore esterno all’apparato col quale si determina l’arresto immediato del cancello. Tale comando è da usare in caso di emergenza.
Fotocellula
Ingresso che fa capo ad una barriera ottica avente lo scopo di intercettare e segnalare il passaggio di persone o autovetture lungo il percorso che attraversa il cancello o nella zona che sta’ in prossimità del medesimo.
5
ITALIANO
Fotostop
Ingresso che fa capo ad una barriera ottica avente lo scopo di intercettare e segnalare il passaggio di persone o autovetture lungo il percorso che attraversa il cancello o nella zona che sta’ in prossimità del medesimo.
3) Definizione uscite
Lampeggiatore
Comando on/off di una lampada che ha lo scopo di preavvisare e segnalare otticamente la condizione di pericolo determinata dal cancello in movimento.
Motore 1
Uscite per il comando apre / chiude del motore collegato all’anta del cancello che è prima in fase di chiusura.
Motore 2
Uscite per il comando apre / chiude del motore collegato all’anta del cancello che in fase di chiusura è ritardata. A tale anta è solitamente collegata la serratura elettrica.
Serratura elettrica
Comando impulsivo per lo sgancio della serratura elettrica.
Luce di cortesia
Comando continuo per lampada che illumina la zona circostante il cancello. La lampada rimane accesa per circa 2 minuti oltre la fine del ciclo. Durante il periodo di pausa a cancello aperto la lampada rimane sempre accesa in modo automatico mentre si spegne in modo condominiale.
Elettrocatenaccio
Comando continuo per lo sgancio di un chiavistello elettrico. Il comando è abilitato solamente durante il funzionamento dei motori.
4) Definizione alimentazioni
Rete 230 Vac
Ingresso per l’alimentazione della scheda elettronica.
Bassa tensione 24 vac
Uscita per l’alimentazione delle fotocellule e/o di altri eventuali dispositivi accessori.
5) Definizione ingressi / uscite accessorie
Antenna
Ingresso per il collegamento di un’antenna radioricevente. Da utilizzare solamente se all’apparato e’ connessa una scheda radioricevitore.
II° canale radio
Uscita di comando ausiliaria. Da utilizzare solamente se all’apparato è connessa una scheda radioricevitore bicanale.
6) Definizione segnalazioni ottiche
LD6 - Led fotocellula (giallo)
Segnala lo stato della barriera ottica. Il led si spegne quando la fotocellula e’ oscurata dal passaggio di persone o autovetture.
6
ITALIANO
LD4 - Led fotostop (giallo)
Segnala lo stato della barriera ottica. il led si spegne quando la fotocellula e’ oscurata dal passaggio di persone o autovetture.
LD5 - Led stop (rosso)
Segnala lo stato di blocco del cancello. Il led si spegne al comando di stop (emergenza ).
LD2 - Led start (verde)
Si accende al comando di start .
LD3 - Led start pedonale (verde)
Si accende al comando di start pedonale .
LD1 - Led alimentazione (verde)
Si accende quando la scheda elettronica è alimentata.
7) Definizione temporizzatori
RV3 - Lavoro
Determina il tempo di funzionamento dei motori in apertura o chiusura.
RV2 - Ritardo M2
Determina il ritardo tra la partenza della prima anta (M1) rispetto alla seconda (M2) nella fase di chiusura.
RV1 - Pausa
Determina la durata della pausa del cancello prima della chiusura in automatico.
8) Definizione dip switch (selezione programmi)
SW1 - Dip switch 1
Stabilisce se l’apparecchiatura deve funzionare con logica passo-passo o in automatico: ON =Automatico OFF=Passo-Passo
SW1 - Dip switch 2
Stabilisce se l’apparecchiatura deve funzionare con la logica determinata dal dip-switch 1 o in modo condominiale: ON=Condominiale OFF=Ininfluente
SW1 - Dip switch 3
Abilita o meno la procedura del colpo d’ariete durante la fase di apertura a cancello chiuso: ON=Abilita colpo d’ariete OFF=Ininfluente
SW2 – Dip Fix
Determina il modo di funzionamento del comando in uscita dal connettore ausiliario J7: Dip fix chiuso = modo elettrocatenaccio Dip Fix aperto = modo luce di cortesia
9) Definizione fusibili di protezione
F1 - Fusibile di rete (5A)
Sconnette l’apparecchiatura elettronica dalla linea di alimentazione di rete in caso di cortocircuito o di anomalia nei consumi di corrente.
F2 - Fusibile bassa tensione (2A)
Protegge l’apparecchiatura elettronica in caso di cortocircuito o sovracorrenti verificatesi sulle fotocellule , sulla serratura elettrica o su altri eventuali dispositivi accessori collegati alla linea di alimentazione 24 vac .
7
ITALIANO
10) Caratteristiche tecniche
Regolatore di potenza
L’apparecchiatura elettronica è predisposta per il collegamento di una eventuale scheda accessoria denominata regolatore di potenza con la quale è possibile ridurre la potenza fornita ai motori.
Attenzione : In caso di guasto o anomalia della scheda regolatore di potenza è possibile che i motori, durante il funzionamento, operino alla massima potenza . È pertanto d’obbligo che venga rispettata la nota 7 riportata nel paragrafo precedente “limitazioni d’uso“.
Spunto
L’apparecchiatura fornisce, all’avvio di qualsiasi motore, la potenza massima per circa 1 secondo, dopo il quale, interviene l’eventuale scheda regolatore di potenza ad essa connessa. Tale caratteristica consente di vincere l’elevata coppia resistente alla partenza dei motori.
Radioricevitore
L’apparecchiatura elettronica è predisposta per il collegamento di una eventuale scheda accessoria denominata radioricevitore che consente di comandare a distanza il cancello a mezzo radiocomando. Il canale 1 del radioricevitore fa capo ad un contatto elettrico non polarizzato (relè) direttamente collegato all’ingresso di start. Il canale 2 del medesimo fa capo ad un contatto elettrico non polarizzato (relè) direttamente collegato all’uscita II° canale radio. Tale uscita viene solitamente collegata all’ingresso start pedonale ma puo’ essere impiegata per altre applicazioni.
Lampeggiatore
La scheda elettronica fornisce un comando on / off (intermittenza) alla lampada con una logica che permette di visualizzare lo stato di funzionamento del cancello. Lampeggio veloce : segnala la fase di apertura Lampeggio lento : segnala la fase di chiusura Luce fissa : segnala che il cancello è fermo nella pausa che precede la fase di chiusura in logica “automatico”. L’apparecchiatura fornisce alla lampada un comando di luce fissa per circa 1,5 secondi prima della partenza dei motori (preallarme).
Tempo di lavoro
Il tempo di funzionamento dei motori è controllato da due Timer digitali indipendenti. Per un corretto funzionamento dell’automazione è necessario impostare il tempo di lavoro in modo tale che sia di poco superiore (2 secondi minimo) al tempo effettivo di corsa del cancello. Se un qualsiasi comando interrompe la corsa dell’anta prima della fine, il Timer si arresta ed il tempo trascorso è memorizzato. L’apparecchiatura è quindi in grado di stabilire, con una certa approssimazione, il tempo di lavoro parziale necessario per terminare la corsa dell’anta. Questa caratteristica impedisce al motore di rimanere alimentato per un lungo periodo dopo la fine della corsa, riducendo al minimo l’effetto di surriscaldamento.
Importante : La mancanza di alimentazione alla scheda elettronica provoca la perdita della posizione memorizzata. Colpo d’ariete
È possibile abilitare o meno la procedura “colpo d’ariete“. Essa è solitamente utilizzata per favorire lo sgancio della serratura elettrica in cattive condizioni ambientali come vento, ghiaccio, ecc. . La procedura consiste in una sequenza logica che attiva la serratura elettrica durante una breve fase di chiusura (1 sec circa) a cancello chiuso e disattiva la stessa solamente dopo la partenza dell’anta in apertura.
8
ITALIANO
Sfasamento ante
L’apparecchiatura impone un ritardo fisso di circa 2 secondi tra la partenza della prima anta ( M2 ) rispetto alla seconda (M1) nella fase di apertura del cancello ovunque esso si trovi . È possibile azzerare tale ritardo regolando al minimo il trimmer relativo allo sfasamento.
Importante : Quando si utilizza l’apparecchiatura su cancelli a singola anta è necessario regolare al minimo il trimmer relativo allo sfasamento.
11) Logica di funzionamento
Premessa
L’apparecchiatura elettronica contiene un microprocessore che gestisce la logica di funzionamento del cancello. Durante il funzionamento si distinguono tre fasi principali :
Fase precedente al moto Fase in cui il cancello è in movimento Fase in cui il cancello è in pausa (aperto)
L’apparecchiatura può gestire tre diverse logiche di funzionamento :
Passo-passo – Si ottiene impostando i dip switch 1=OFF 2=OFF Automatico - Si ottiene impostando i dip switch 1=ON 2=OFF
Condominiale - Si ottiene impostando i dip switch 1=Ininfluente 2=ON La logica di funzionamento Condominiale è prioritaria. Se vengono selezionate più logiche contemporaneamente andrà in uso quella prioritaria. Attenzione : L’impostazione della logica di funzionamento (dip switch) così come la regolazione dei temporizzatori (Trimmer) deve essere eseguita
solamente quando il ciclo di lavoro è completato o deve iniziare (cancello chiuso). Il ciclo di funzionamento di apertura o chiusura è avviato da un comando di Start. Importante : Il primo comando di Start fornito dopo aver alimentato la scheda elettronica determina sempre l’avvio di un ciclo di apertura qualunque
sia la logica selezionata.
Logica “passo - passo“
Dopo aver fornito la tensione di alimentazione alla scheda elettronica il primo comando di start da inizio ad un ciclo di apertura. Trascorso il tempo di lavoro per entrambi i motori la corsa è terminata ed il cancello si arresta. Il ciclo di lavoro è completato ( lampeggiatore spento) in attesa di un nuovo comando di start per la chiusura. Fornendo un comando di start a corsa non ultimata il cancello si arresta. Un successivo comando di start determina l’inversione del moto.
Logica “automatico“
Dopo aver fornito la tensione di alimentazione alla scheda elettronica il primo comando di start avvia un ciclo di apertura. Trascorso il tempo di lavoro per entrambi i motori la corsa è terminata ed il cancello si arresta dando inizio al periodo di pausa ( lampeggiatore acceso con luce fissa ). Trascorso il tempo di pausa il cancello chiude automaticamente. Il ciclo di lavoro è completato al termine della fase di chiusura (lampeggiatore spento).
9
ITALIANO
Fornendo un comando di start a corsa non ultimata il cancello si arresta. Un successivo comando di start determina l’inversione del moto. Un comando di start fornito durante la pausa interrompe il ciclo di lavoro( lampeggiatore spento ) ed il cancello non chiude automaticamente. Un successivo comando di start avvia un ciclo di chiusura.
Logica “condominiale“
Dopo aver fornito la tensione di alimentazione alla scheda elettronica il primo comando di start avvia un ciclo di apertura. Trascorso il tempo di lavoro per entrambi i motori la corsa è terminata ed il cancello si arresta dando inizio al periodo di pausa (lampeggiatore spento). Trascorso il tempo di pausa il cancello chiude automaticamente. Il ciclo di lavoro è completato solamente al termine della fase di chiusura. Un comando di start fornito durante l’apertura è ininfluente. Un comando di start fornito durante la chiusura provoca l’arresto e l’inversione di marcia dopo circa 1,5 secondi. Un comando di start fornito durante il tempo di pausa ricarica il medesimo allungando il periodo che precede la chiusura automatica.
Importante : Se l’apertura del cancello è comandata da un orologio è necessario abilitare la logica di funzionamento condominiale. Nota : All’inizio di ogni ciclo di apertura la serratura elettrica è attivata qualche decimo di secondo ( 0,8 sec ) prima dell’avvio della prima anta (M2) ed
è disattivata qualche decimo di secondo (0,4 sec) dopo la partenza della stessa. Tale sequenza è valida solamente se il dip switch 3 è in posizione OFF.
Qualunque sia la logica di funzionamento in uso, l’intervento dei dispositivi di sicurezza produce gli effetti di seguito descritti : Stop : Se il comando di stop è attivo impedisce l’avvio di qualsiasi ciclo e rende il comando di start ininfluente. Un comando di stop fornito durante il
moto provoca l’arresto immediato del cancello interrompendo il ciclo di lavoro. Tale condizione persiste sino a che esso è presente. Dopo un comando di stop il successivo comando di start avvia sempre un ciclo di apertura. Un comando di stop fornito durante il tempo di pausa interrompe il ciclo di lavoro. Il successivo comando di start da inizio ad un ciclo di chiusura.
Fotocellula : È influente solamente durante la fase di chiusura o nel periodo di pausa. Se un ostacolo oscura la fotocellula durante la chiusura
Fotostop : Se un ostacolo oscura la cellula fotoelettrica durante il moto, qualunque sia il senso di marcia, o nella fase che precede l’avvio del ciclo di
Start pedonale : Il comando start pedonale agisce allo stesso modo dell’altro comando di start ma determina l’apertura o la chiusura solamente
provoca l’arresto e l’inversione di marcia dopo circa 1,5 secondi. L’intervento della fotocellula durante il tempo di pausa ricarica il medesimo allungando il periodo che precede la chiusura automatica.
lavoro provoca l’arresto temporaneo del cancello sino a che rimane in tale stato. Il lampeggiatore segnala con luce fissa la condizione anomala. Non appena l’ostacolo è rimosso e la cellula fotoelettrica è libera ha sempre inizio un ciclo di apertura. Tale condizione non è valida solamente quando, una volta completato il ciclo di apertura, un comando di start avvia la fase di chiusura in logica passo - passo. L’intervento del fotostop durante il tempo di pausa ricarica il medesimo allungando il periodo che precede la chiusura automatica.
dell’anta (M2) che porta la serratura elettrica. Il comando start pedonale è ininfluente durante un ciclo di start sino al termine della fase di chiusura ( cancello chiuso ). Durante un ciclo di start pedonale il comando di start è sempre attivo.
10
ITALIANO
12) Caratteristiche elettriche e meccaniche
Dimensioni : 177 x 247 x 92 mm Peso : 1,3 Kg Alimentazione generale : 230 Vac +/- 10% Potenza assorbita a riposo : 1 W circa Temperatura di funzionamento : da 0 a + 60 °C Alimentazione motori monofase : 230 Vac 1 HP max Alimentazione lampeggiatore : 230 Vac 40 W max Alimentazione serratura elettrica : 12 Vac 15 W max Alimentazione accessori : 24 Vac 6 W max Caratteristiche contatto II° canale radio : 24 Vac 0,5 A max Regolazione tempo di lavoro motori : da 0 a 100 secondi Regolazione tempo di pausa : da 2 a 100 secondi Regolazione ritardo in chiusura II anta : da 0 a 25 secondi
attenzione : Non mettere in servizio l’apparecchiatura se i carichi ad essa collegati o la tensione di alimentazione non rientrano nei valori limite
13) Collegamenti elettrici
Sulla scheda si distinguono 6 connettori elettrici :
a) J5 morsettiera a 10 poli per il collegamento dei dispositivi che operano con la tensione di rete 230 Vac (motori, lampeggiatore e cavo di rete) b) J6 morsettiera a 10 poli per il collegamento dei dispositivi che operano in bassa tensione (comandi, dispositivi di sicurezza, elettroserratura ed
uscita di alimentazione 24 Vac)
c) J4 morsettiera a 4 poli per il collegamento di elementi ausiliari che operano in bassa tensione (uscita II°canale radio ed antenna) d) J7 morsettiera a 2 poli per il collegamento di elementi ausiliari che operano con la tensione di rete 230 Vac (luce di cortesia o elettrocatenaccio) e) J3 connettore a 4 poli per il collegamento di eventuale scheda regolatore di potenza f) J2 connettore a 10 poli per il collegamento di eventuale scheda radioricevitore
Morsettiera J5
Morsetto 1 - Fase alimentazione di rete 230 Vac Morsetto 2 - Neutro alimentazione di rete 230 Vac
Attenzione : Le polarità della tensione di alimentazione devono essere rigorosamente rispettate. Morsetto 3 - Fase apre alimentazione 230 Vac motore M1
Morsetto 4 - Fase chiude alimentazione 230 Vac motore M1 Morsetto 5 - Comune alimentazione 230 Vac motore M1
Nota : Collegare il condensatore di rifasamento del motore M1 tra i morsetti 3 e 4.
sopradescritti. Il mancato rispetto può causare danni a persone, cose o animali, nei confronti dei quali il costruttore non può essere considerato responsabile.
11
ITALIANO
Morsetto 6 - Fase apre alimentazione 230 Vac motore M2 ritardato in chiusura Morsetto 7 - Fase chiude alimentazione 230 Vac motore M2 ritardato in chiusura Morsetto 8 - Comune alimentazione 230 Vac motore M2 ritardato in chiusura
Nota : Collegare il condensatore di rifasamento del motore M2 tra i morsetti 6 e 7. Morsetto 9 - Fase alimentazione 230 Vac lampeggiatore
Morsetto 10 - Neutro alimentazione 230 Vac lampeggiatore
Morsettiera J6
Morsetto 1 - Alimentazione 12 Vac serratura elettrica Morsetto 2 - Alimentazione 12 Vac serratura elettrica (Comune) Morsetto 3 - Alimentazione 24 Vac per fotocellule o altri dispositivi (Comune) Morsetto 4 - Alimentazione 24 Vac per fotocellule o altri dispositivi Morsetto 5 - Morsetto comune di tutti i contatti elettrici relativi a comandi o dispositivi di sicurezza . Morsetto 6 - Contatto elettrico normalmente chiuso della fotocellula . Morsetto 7 - Contatto elettrico normalmente chiuso del pulsante di emergenza (stop). Morsetto 8 - Contatto elettrico normalmente chiuso della cellula fotoelettrica (fotostop). Morsetto 9 - Contatto elettrico normalmente aperto del pulsante di start. Morsetto 10 - Contatto elettrico normalmente aperto del pulsante di start pedonale
Importante : Gli ingressi normalmente chiusi devono essere ponticellati se non vengono utilizzati.
Morsettiera J4
Morsetto 1 - Contatto elettrico normalmente aperto del II° canale radio (uscita). Morsetto 2 - Contatto elettrico normalmente aperto del II° canale radio (uscita). Morsetto 3 - Collegamento cavo antenna (calza) per scheda radioricevitore. Morsetto 4 - Collegamento cavo antenna (segnale) per scheda radioricevitore.
Morsettiera J7
Morsetto 1 - Fase alimentazione 230 Vac elettrocatenaccio o luce di cortesia Morsetto 2 - Neutro alimentazione 230 Vac elettrocatenaccio o luce di cortesia
Connettore J3
Morsetto 1 – Comune dei motori M1 ed M2 Morsetto 2 – Comune dei motori M1 ed M2 Morsetto 3 – Comune dei motori M1 ed M2 Morsetto 4 – Neutro alimentazione di rete 230 Vac Importante : Nel caso non venga collegata la scheda regolatore di potenza è obbligatorio ponticellare i morsetti 3 e 4 del connettore J3 tramite un terminale faston isolato da 4 mm.
12
ITALIANO
Connettore J2
Morsetto 1 - Contatto elettrico normalmente aperto connesso allo start Morsetto 2 - Comune del contatto elettrico normalmente aperto connesso allo start Morsetto 3 - Contatto elettrico normalmente aperto connesso all’uscita II° canale radio Morsetto 4 - Contatto elettrico normalmente aperto connesso all’uscita II° canale radio Morsetto 5 - Comune alimentazione 24 Vac Morsetto 6 - Alimentazione 24 Vac Morsetto 7 - Alimentazione 24 Vac Morsetto 8 - Comune alimentazione 24 Vac Morsetto 9 -.Ingresso antenna (calza) Morsetto10 - Ingresso antenna (segnale)
Connessione dispositivi
Cavo alimentazione di rete 230 Vac – Morsetti 1 e 2 di J5 Attenzione : Il polo di terra del cavo deve obbligatoriamente essere connesso ad un buon riferimento di terra che stà in prossimità del
cancello. Motore 1 – Morsetti 3, 4 e 5 di J5
Motore 2 – Morsetti 6, 7 e 8 di J5 Lampeggiatore – Morsetti 9 e 10 di J5 Serratura elettrica – Morsetti 1 e 2 di J6 Alimentazione fotocellule – Morsetti 3 e 4 di J6 Contatto fotocellula NC – Morsetti 5 e 6 di J6 Pulsante di stop NC – Morsetti 5 e 7 di J6 Contatto fotostop NC – Morsetti 5 e 8 di J6 Pulsante di start pedonale NO – Morsetti 5 e 9 di J6 Pulsante di start NO – Morsetti 5 e 10 di J6 Antenna – Morsetti 3 e 4 di J4 Luce di cortesia – Morsetti 1 e 2 di J7 Elettrocatenaccio – Morsetti 1 e 2 di J7
Importante : Prima di avviare il cancello verificare che le connessioni alla scheda elettronica siano corrette. A tal fine verificare anche la commutazione dei contatti elettrici segnalata dall’accensione e/o spegnimento dei led.
13
ITALIANO
E) Manutenzione
Attenzione : La manutenzione dell’apparecchiatura deve essere effettuata solo ed esclusivamente da un tecnico specializzato ed autorizzato dalla
casa costruttrice. Qualsiasi operazione di mantenimento o controllo dell’apparecchiatura deve essere effettuata in assenza di tensione di alimentazione.
Manutenzione ordinaria : Ogni volta che si avverte la necessità e comunque ogni 6 mesi si raccomanda di verificare lo stato di funzionamento dell’apparecchiatura. Manutenzione straordinaria: Se dovessero rendersi necessari interventi non banali sull’apparecchiatura, si raccomanda la rimozione della stessa, per consentire la riparazione in laboratorio ad opera di tecnici della casa costruttrice o da essa autorizzati.
La casa costruttrice si solleva da qualsiasi responsabilità per la mancata osservanza delle norme sopra descritte.
F) DICHIARAZIONE DI CONFORMITÀ (Secondo la direttiva EMC EN45014 e la guida 22 dell’ISO).
Ragione sociale e sede del fabbricante : Leb electronics s.r.l.
Via Valle Maria , 55/a 46040 Casalmoro (MN) Italia
Descrizione dell’apparecchiatura: Quadro elettronico adibito al comando di 1 o 2 motori asincroni monofase 230 Vac destinati
Modello: CTR17.04 Norme di riferimento applicate : EN 50081-1, EN 50082-1, EN 55014 Norme di base applicate : EN 61000-3-2, EN 61000-3-3, EN 61000-4-4, EN 61000-4-2, ENV 50140 Laboratorio di prova : Intek s.p.a. Esito : Positivo Il fabbricante dichiara che i prodotti sopraelencati sono conformi alle normative previste dalle direttive 89/336/EEC, 92/31/EEC, 93/68/EEC sulla
compatibilità elettromagnetica.
Casalmoro , 01-01-2000
all’automazione di un cancello.
14
G) Programmazione scheda
Logica Passo-Passo Logica Condominiale
ON OFF
3
Posizionare i dip switch 1 e 2 in OFF.
2
Lo stato del dip switch 3 è ininfluente.
1
Logica Automatico Logica Colpo d’ariete
ON OFF
3
Posizionare il dip switch 1 in ON.
2
Posizionare il dip switch 2 in OFF.
1
Lo stato del dip switch 3 è ininfluente.
Logica Elettrocatenaccio / Luce di cortesia
ON OFF
3 2 1
ON OFF
3 2 1
Lo stato del dip switch 1 è ininfluente. Posizionare il dip switch 2 in ON. Lo stato del dip switch 3 è ininfluente.
Lo stato del dip switch 1 è ininfluente. Lo stato del dip switch 2 è ininfluente. Posizionare il dip switch 3 in ON.
ITALIANO
SW2 Aperto SW2 Chiuso Per abilitare la logica Luce di cortesia
aprire lo switch SW2. Per abilitare la logica Elettrocatenaccio
chiudere lo switch SW2.
15
ITALIANO
Alimentazione
Regolazione Temporizzatori
Lavoro Ritardo M2 Pausa
Schema generale
FOTOC NC
START NO
LD1
RV3 RV2 RV1
1 2 3 4 5 6 7 8 9
J2
3 2 1
SW1
SW2
F
2
24Vac 2A
Fusibile B.T.
10
Collegamento
Radioricevitore
LD6 LD5 LD4 LD3 LD2
Dip switch
Led di segnalazione
J4
1 2 3 4
FTC STP FTS STPD ST
J6
Selezione programmi
1 2 3 4 5 6 7 8 9 10
ANT
USCITA II°
CAN. RADIO
ELETTRICA
SERRATURA
LAMP
ST.PED. NO
J5
FTSTP NC
STOP NC
24 Vac
USCITA
Comune comandi e sicurezze
COND
COM
M2
1 2
J7
Coll. Luce di cortesia
o elettrocatenaccio
1 2 3
4
J3
Collegamento scheda
regolatore di coppia
230 Vac 5A
Fusibile di rete
F
1
1 2 3 4 5 6 7 8 9 10
F
N
230 Vac
GIALLO-VERDE
COM
CH AP AP
M1
CH
TERRA
COND
16
TABLE OF CONTENTS
ENGLISH
A Scope of the device…………………………….
B Limits to use……………………………………….
C Installation………………………………………….. D Operation…………………………………………….
D.1 Controls…………………………………………………. 19 D.2 Safety devices………………………………………….. 19 D.3 Outputs………………………………………………….. 19 D.4 Power supply…………………………………………… 20 D.5 Accessory inputs/outputs……………………………… 20 D.6 Optical signals………………………………………….. 20 D.7 Trimmers………………………………………………... 21 D.8 Dip switches…………………………………………….. 21 D.9 Protection fuses………………………………………... 21 D.10 Technical features……………………………………... 21 D.11 Operation modes……………………………………….. 23 D.12 Electrical and mechanical specifications…………….. 25 D.13 Electric connections……………………………………. 25
18
18
19
19
E Maintenance………………………………………..
F Conformity declaration………………………..
G Board programming…………………………… H General diagram………………………………….
28
28
29
30
17
ENGLISH
A) – Scope of the device
Electronic board controlling 1 or 2 230 Vac single-phase asynchronous motors for the automation of a single or two-wing gate.
B) – Limits to use
Caution : Before operating the electronic unit make sure the following operations have been carried out. Note 1 – Read carefully the whole technical documentation supplied.
Note 2 – The electronic unit must be installed by qualified personnel only. The installation engineer must have the necessary technical and
professional qualification.
Note 3 – The mains power supply connected to the unit must be 230 Vac +/- 10%. Note 4 – The neutral (N) pole of the mains power supply must be unipotential to the ground. Note 5 – All security norms for the installation of electric and electronic devices must be respected. Note 6 – The mains power must be supplied with an efficient differential switch tested and calibrated in conformity with the applicable rules. Note 7 – Before installing the electronic unit check the motors to which it will be connected. When the motors are connected to the mains power the
Note 8 – The unit must be applied for the intended use only (see point A). All other use is to be considered improper and dangerous. Note 9 – Before acceding to the electronic unit’s box for any intervention check that the mains power has been cut off. Note 10 – Do not access the unit with wet/damp hand or feet. Note 11 – Do not expose the unit to weather (rain, snow, etc.) Note 12 – Do not allow any children or unqualified persons to touch the unit. Note 13 – The electronic unit must be placed in the box supplied. Note 14 – The plastic material used for the box is not self-extinguishing. Therefore it must be installed in an well aired place far from any objects or
Note 15 – The ordinary maintenance of electronic unit must be executed by qualified personnel every 6 months. Caution: Failure to respect the above listed norms can cause damage to persons, animals or objects. The manufacturer can in no way be
torque they apply to the gate must respect the applicable rules and, in any case, it must be such that in case of collision no damage will be caused to persons, animals or objects.
elements that can cause fire.
held responsible for such damage.
18
ENGLISH
C) – Installation
1) Unscrew the cover screws and lift the cover. Check that the electronic unit is in good order. In case of doubt do not install the unit and ask for
the intervention of qualified personnel. The container’s accessories (screws, round seal, cable glands) must not be left within the reach of children since they are a potential danger.
2) Check that the electronic unit is properly fixed to its box. If not, tighten all screws or provide the missing screws.
3) Place the unit near the gate so that the system connection wires’ length is reduced to the minimum.
Caution: For the unit’s correct operation the wires connected to it must not be longer than 10 metres.
4) For increased weather protection we recommend to place the unit under a roof or, even better, in an enclosure having two side walls.
Wherever possible, it is advisable to install the unit at a minimum 1,5 mt level above the ground to keep it out of the reach of children.
5) Before proceeding to assembly place the container so that the side fitted with the cable glands is directed towards the ground. Caution: Do not assemble the container on wood surfaces.
6) Insert the supplied round seal in its seat. Make sure the two ends meet at the centre of the side to which the cable glands are fitted.
7) Lift the mobile portion of the connector and proceed to connect the unit wires as described in the following chapters.
D) - Operation
1) Definitions of Controls
Start
Input connected to a push-button placed outside the unit. It is employed to request the gate’s opening or closure (for both wings). This input is usually connected to a key push-button.
Pedestrian Start
Input connected to a push-button placed outside the unit. It is employed to request the opening or closure of one wing only (pedestrian wing) to allow the passage of persons or animals.
2) Definitions of Safety devices
Stop
Input connected to a push-button or switch placed outside the unit. It is employed to cause the gate’s immediate stop. This control must used in an emergency situation.
Photo-cell
Input connected to an optical barrier. It detects and signal the passage of persons or vehicles in the area crossed by the gate or in the nearby area.
Photostop
Input connected to an optical barrier. It detects and signal the passage of persons or vehicles in the area crossed by the gate or in the nearby area.
3) Definitions of Outputs
Blinker
Lamp’s on/off control. The lamp functions as a warning and optical signaller of potential danger for the gate’s motion.
19
ENGLISH
Motor 1
Outputs for the opening/closure control of the motor which drives the first gate wing during the closing phase.
Motor 2
Outputs for the opening/closure control of the motor which drives the gate wing delayed during the closing phase. This wing is usually connected with an electric lock.
Electric lock
Impulse control for the electric lock release.
Courtesy light
Continuous control for the lamp which lights the area around the gate. The lamp is lit for approx. 2 minutes after the cycle has ended. During the pause before the gate closes back the lamp is lit in automatic mode or goes off in condominium mode.
Electrochain
Continuous control for the electric chain release. The control is enabled only during the motors’ operation.
4) Definitions of Power Supply Inputs/Outputs
230 Vac mains power
Input for the electronic board power supply.
24 Vac low voltage
Power supply output for the photo-cells and/or any other accessory devices.
5) Definitions of Accessory Inputs/Outputs
Aerial
Input for the connection of a radio receiving aerial. This input can only be used if a radio receiver card is connected to the unit.
2nd radio channel
Auxiliary control output. To be used only if a two-channel radio receiver card is connected to the unit.
6) Definitions of Optical Signals
LD6 – Photo-cell led (yellow)
It signals the optical barrier’s state. The led goes off when the photo-cell is covered by persons or vehicles. LD4 – Photostop led (yellow) It signals the optical barrier’s state. The led goes off when the photo-cell is covered by persons or vehicles.
LD5 – Stop led (red)
It signals the gate’s block state. The led goes off when the stop control is operated (emergency).
LD2 – Start led (green)
It is lit when the start control is operated.
LD3 – Pedestrian start led (green)
It is lit when the pedestrian start control is operated.
LD1 – Power supply led (green)
It is lit when the electronic card power supply is present.
20
ENGLISH
7) Definitions of Trimmers
RV1 - Pause
It defines the duration of the gate’s pause before automatic closure.
RV2 - M2 Delay
It defines the delay between the first wing’s (M1) and the second wing’s (M2) start during the closure phase.
RV3 – Work time
It defines the motors’ work time during the opening or closure phases.
8) Definitions of Dip Switches (Selection of Programs)
SW1 - Dip switch 1
It chooses whether the unit will operate in step-by-step mode or in automatic mode. ON =Automatic OFF=Step by step
SW1 - Dip switch 2
It chooses whether the unit will operate in the mode determined by dip-switch 1 or in condominium mode. ON=Codominium OFF=No effect
SW1 - Dip switch 3
It enables or excludes the kickback (during the opening phase with closed gate). ON= Kickback enabled OFF=No effect
SW2 – Dip Fix
It determines the operation mode of the J7 auxiliary connector’s output. Closed Dip fix = electrochain mode Opened Dip Fix = courtesy light mode
F1 – Mains power fuse (5A)
It disconnects the electronic unit from the power supply mains in case of short-circuit or electric current consumption anomalies.
F2 – Low voltage fuse (2A)
It protects the electronic unit in case of short circuits or overcurrents on photo-cells, electric lock or any other accessory devices connected to the 24 Vac power supply.
10) Technical features
Power regulator
The electronic unit is pre-set for the optional connection of an accessory card called “power regulator”. By means of this card the power supplied to the motors can be reduced.
Caution: In case failure or anomaly of the power regulator card the motors may operate at their maximum power value. This is why n° 7 note in the previous chapter “limits to use” must absolutely be put into practice.
21
ENGLISH
Starting of maximum start up power
When any of the motors starts the unit supplies the maximum power value for approx. 1 sec. Subsequently the unit’s power regulator card, if present, operates. This particular feature allows to overcome the high negative torque at the motors’ start.
Radioreceiver
The electronic unit is pre-set for the optional connection of an accessory radio receiver card allowing remote control of the gate by means of the radio transmitter. The channel 1 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the start input. The channel 2 of the radio receiver card ends with a non-polarized electric contact (relay) directly connected to the 2nd radio channel output. This output is usually connected to the pedestrian start input, although it may be used also for other applications.
Blinker
The electronic card supplies an on/off control (flashing light) to the lamp. The logic of the blinking allows displaying the gate’s operating. Quick flashing light : it signals the opening phase Slow flashing light : it signals the closing phase Fixed light : it signals that the gate is blocked in pause before the closure phase in “automatic” mode. The device supplies an on/off control (fixed light) to the lamp for approx. 1,5 sec. before the motors start (pre-alarm).
Work time
The motors’ work time is controlled by two independent digital timers. For the automation system to work properly the operating time value to be set must be slightly (min. 2 sec.) above the gate’s actual work time. If any command interrupts the wing’s travel before its end, the Timer stops and the elapsed time is stored in memory. Therefore the unit can determine, with a fair approximation, the partial working time necessary to the wing to end its travel. Thanks to this feature it is possible to avoid that the motor works for a long time after the end of the wing’s travel, thus reducing overheating to the minimum.
Warning : In case of absence of power supply the stored position will be lost. Kickback
This procedure can be enabled or excluded. It is usually employed to help the electric lock release during bad weather conditions (wind, ice, etc.). The “kickback” procedure consists of a logic sequence operating the electric lock during a short closure phase (approx 1 sec.) with the gate closed. The electric lock is released only after the wing has started its opening motion.
M1 delay at opening
The unit causes a fixed delay of approx. 2 seconds between the first wing’s (M2) and the second wing’s (M1) start during the gate’s opening phase. This delay is imposed irrespective of the position from which the gate starts to open. This delay may be cancelled by setting the M2 delay trimmer to its minimum value.
Warning: In case of single-wing gate it is necessary to set the M2 delay trimmer to its minimum value.
22
ENGLISH
11) Operation modes
Introduction
The electronic unit contains a micro-processor to control the gate’s operation modes. These are the three main operation phases :
Phase preceding the gate’s motion Gate’s motion phase Gate’s pause phase (open gate)
The unit can function in three modes :
Step by step – This mode is enabled by setting the dip switches 1=OFF 2=OFF Automatic – This mode is enabled by setting the dip switches 1=ON 2=OFF
Condominium– This mode is enabled by setting the dip switches 2=ON 1= No effect The Condominium mode is the priority operation mode. If more than one modes are selected the priority mode will be enabled. Notice: The operation logic setting (dip switch), the work time programming and the pause time programming must be carried out only if the cycle is
concluded or before it starts (with closed gate). The opening and closure cycles are enabled by a Start command. Important : Whatever logic has been selected, the first Start command after the power is supplied to the electronic card will always cause the start of
an opening cycle.
“Step-by-step” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times, the gate stops. The operating cycle is completed (blinker off) and the system waits for a new start command to determine the closing cycle. If a start command is supplied when the end of travel has not been reached yet the gate stops. A new start command will cause the reversal of the motion.
“Automatic” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times, the gate stops. The pause period starts (blinker on with fixed light). At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion has ended (blinker off). If a start command is supplied before the end of travel is reached the gate stops. A new start command will cause the gate to reverse its motion. If a start command is supplied during the pause period the operating cycle is interrupted (blinker off) and the gate does not close automatically. A further start command will determine a closing cycle.
23
ENGLISH
“Condominium” mode
After the power is supplied to the electronic card the first start command determines an opening cycle. At the end of the two work times, the gate stops. The pause period starts (blinker off). At the end of the pause period the gate closes automatically. The operating cycle is complete only when the closing motion has ended. If a start command is supplied while the gate opens, the command will have no effect. If a start command is supplied while the gate closes, the gate will stop and reverse its motion after approx. 1.5 sec. If a start command is supplied during the pause period, the period will be reset and the automatic closure will start later.
Important : If the gate opening is controlled by a clock the “condominium” mode must be enabled. Note : If dip switch 3=OFF the electric lock operates a split of second ( 0,8 sec ) before the first wing (M2) starts , and stops operating a split of
second ( 0,4 sec ) after the wing’s start. In any operation mode, the safety devices causes the following effects : Stop : If the stop command is enabled no cycles can start and the start command will have no effect. If a stop command is supplied during motion,
the gate will immediately stop e interrupt its operating cycle. This condition will continue until the stop command is on. A start command
following a stop command always determines an opening cycle. A stop command supplied during the pause period interrupts the operating
cycle. A start command subsequently supplied will start a closure cycle. Photo-cell : This device has effect only during the closure phase or in the pause period. If an obstacle covers the photo-cell during the closure phase,
the gate stops and reverses its motion after approx. 1,5 sec. If an obstacle covers the photo-cell during the pause period this last one is
reset and the automatic closure is therefore delayed. Photostop : If an obstacle covers the photo-cell during the gate’s motion (opening or closure), or during the period preceding the operating cycle’s
start, then the gate is temporarily stopped, until the obstacle is not removed. The blinker will light with a fixed light to signal the irregular
condition. When the obstacle is removed and the photocell is freed, an opening cycle will start. This does not apply when a start
command determines the closing phase in step-by-step mode at the end of an opening cycle. If an obstacle covers the photostop during
the pause period this last one is reset and the automatic closure is therefore delayed. Pedestrian start: The pedestrian start command operates in the same way as the other start command, but in this case only the wing fitted with the
electric lock (M2) will be opened or closed. The pedestrian start command has no effect during a start cycle and up to the end of the
closing phase (closed gate). During a pedestrian start cycle the start command is always active.
24
ENGLISH
12) Electrical and mechanical specifications
Dimensions and weight : 177 x 247 x 92 mm - 1,3 Kg Mains power supply : 230 Vac +/- 10% Stand-by power consumption : approx. 1 W Operating temperature range : 0 to + 60 °C Single-phase motors power supply : 230 Vac 1 HP max Blinker power supply : 230 Vac 40 W max Courtesy light power supply : 230 Vac 40 W max Electric lock power supply : 12 Vac 15 W max Accessories power supply : 24 Vac 6 W max 2nd radio channel relay contact : 24 Vac 0,5 A max Motors’ work time : programmable, 0 to 100 sec. Pause time : programmable, 2 to 100 sec. 2nd wing closing delay : programmable, 0 to 25 sec.
Caution : The unit must be not switched on if the connected loads or the power supply exceed the a.m. limits. Failure to observe this precaution can
result in damage to persons, animals or objects for which the manufacturer cannot be held responsible.
13) Electric connections
6 electric connectors are fitted to the card :
1) J5 10-pole Terminal board for the connection of the devices operating with 230 Vac mains power supply (motors, blinker, mains cable).
2) J6 10-pole Terminal board for the connection of the devices operating at low voltage (commands, safety devices, electric lock and 24 Vac power
supply output)
3) J4 4-pole Terminal board for the connection of the auxiliary devices operating at low voltage (aerial and 2nd radio channel output)
4) J7 2-pole Terminal board for the connection of the auxiliary devices operating with 230 Vac mains power supply ( courtesy light or electric chain )
5) J3 4-pole connector for the optional connection of a power regulator card
6) J2 10-pole connector for the optional connection of a radio receiver card
Terminal board J5
Terminal1 - 230 Vac mains power supply phase Terminal2 - 230 Vac mains power supply neutral
Warning: The power supply voltage polarities must be carefully observed. Terminal3 - 230 Vac motor M1 power supply phase (opening)
Terminal4 - 230 Vac motor M1 power supply phase (closure) Terminal5 - 230 Vac motor M1 Power supply common
Note: connect the capacitor of the motor M1 between terminals 3 and 4
25
ENGLISH
Terminal6 - 230 Vac motor M2 power supply phase (opening) Terminal7 - 230 Vac motor M2 power supply phase (closure) Terminal8 - 230 Vac motor M2 Power supply common
Note: connect the capacitor of the motor M2 between terminals 6 and 7 Terminal9 - 230 Vac blinker power supply phase
Terminal10 - 230 Vac blinker power supply neutral
Terminal board J6
Terminal1 – Electric lock 12 Vac power supply Terminal2 – Electric lock 12 Vac power supply (common) Terminal3 – 24 Vac power supply for photo-cells or other devices (common) Terminal4 – 24 Vac power supply for photo-cells or other devices Terminal5 – Common terminal for all electric contacts of commands or security devices Terminal6 – Photo-cell’s normally closed electric contact Terminal7 – Emergency push-button’s normally closed electric contact (stop) Terminal8 – Photoelectric cell’s normally closed electric contact (photostop) Terminal9 – Start push-button’s normally open electric contact Terminal10– Pedestrian start push-button’s normally open electric contact
Important: The normally closed inputs not in use must be fitted with jumpers
Terminal board J4
Terminal1 – 2nd radio-channel’s normally open electric contact (output) Terminal2 – 2nd radio-channel’s normally open electric contact (output) Terminal3 – Aerial cable connection (shield) for radio receiver card Terminal4 - Aerial cable connection (signal) for radio receiver card
Terminal board J7
Terminal1 – Courtesy light’s or electric chain’s 230 Vac power supply phase Terminal2 – Courtesy light’s or electric chain’s 230 Vac power supply neutral
Connector J3
Terminal1 – 230 Vac motors M1 and M2 Power supply common Terminal2 – 230 Vac motors M1 and M2 Power supply common Terminal3 – 230 Vac motors M1 and M2 Power supply common Terminal4 – 230 Vac mains power supply neutral Important: If the power regulator card is not connected the J3 connector’s terminals 3 and 4 must be bridged with 4 mm insulated faston terminal.
26
ENGLISH
Connector J2
Terminal1 – Normally open electric contact connected to the start Terminal2 – Common of the normally open electric contact connected to the start Terminal3 – Normally open electric contact connected to the 2nd radio-channel output Terminal4 – Normally open electric contact connected to the 2nd radio-channel output Terminal5 – 24 Vac power supply (common) Terminal6 - 24 Vac power supply Terminal7 - 24 Vac power supply Terminal8 - 24 Vac power supply (common) Terminal9 – Aerial input (shield) Terminal10 – Aerial input (signal)
Connection of the devices 230 Vac mains power supply cable – Terminals 1 and 2 on J5
Warning: The cable’s ground pole must be connected to a good ground reference in the gate’s nearby area. Motor 1 – Terminals 3, 4 and 5 on J5
Motor 2 – Terminals 6, 7 and 8 on J5 Blinker – Terminals 9 and 10 on J5 Electric lock – Terminals 1 and 2 on J6 Photo-cells power supply – Terminals 3 and 4 on J6 NC photo-cell contact – Terminals 5 and 6 on J6 NC stop push-button – Terminals 5 and 7 on J6 NC photostop contact – Terminals 5 and 8 on J6 NO pedestrian start push-button – Terminals 5 and 9 on J6 NO start push-button – Terminals 5 and 10 on J6 Aerial – Terminals 3 and 4 on J4 Courtesy light– Terminals 1 and 2 on J7 Electrochain – Terminals 1 and 2 on J7
Important: Before starting the gate check all connections to the electronic card. Check also the electric contacts’ switching, which is signalled by the leds’ operation.
27
ENGLISH
E) MAINTENANCE
Warning : The maintenance of the device must be effected only and exclusively by a specialized technician authorized from the Manufacturer.
Any operation of maintenance or control of the device must be effected in absence of power supply.
Ordinary maintenance: Every time that it is necessary and however every 6 months is recommended to verify the device operation. Extraordinary maintenance: In case of failure, remove the device and send it for repair to the manufacturer laboratory or to authorized laboratory.
The Manufacturer is not responsible for missing observance of rules above described.
F) CONFORMITY DECLARATION (To EMC directive EN45014 and ISO guide 22)
Company name and registered office :
Description of the appliance : Electronic board for the control of 1 or 2 230 Vac single-pha se asynchronous motors for gate
Model : CTR17.04 Reference rules applied : EN 50081-1, EN 50082-1, EN 55014 Basic rules applied : EN 61000-3-2, EN 61000-3-3, EN 61000-4-4, EN 61000-4-2, ENV 50140 Test laboratory : Intek s.p.a. Outcome : Positive The manufacturer declares that the above listed products comply to the norms on electromagnetic compatibility provided for by directives 89/336/EEC,
92/31/EEC, 93/68/EEC.
Casalmoro , 01-01-2000
Leb electronics s.r.l. Via Valle Maria , 55/a 46040 Casalmoro (MN) Italia
automation.
28
G) Programming the board
Step by step logic Condominium logic
ON OFF
3 2 1
Set the dip switches 1 and 2 to OFF The state of the other dip switches has no effect
ON OFF
3 2 1
Set the dip switch 2 to ON The state of the other dip switches has no effect.
Automatic logic Kickback logic
ON OFF
3 2 1
Set the dip switch 2 to OFF Set the dip switch 1 to ON The state of the other dip switches has
ON OFF
3 2 1
Set the dip switch 3 to ON The state of the other dip switches has no effect
no effect
Electrochain / courtesy light logic
SW2 Opened SW2 Closed
Opened Dip Fix SW2 = courtesy light mode Closed Dip fix SW2 = electrochain mode
ENGLISH
29
ENGLISH
Power supply
Timers
Work M2 Delay Pause
General diagram
FOTOC NC
START NO
LD1
RV3 RV2 RV1
1 2 3 4 5 6 7 8 9
J2
3 2 1
SW1
SW2
F
2
24 Vac 2A
Fuse low voltage
10
Radio-receiver
LD6 LD5 LD4 LD3 LD2
Dip switch
Optical signallings
Selection of the programs
J4
1 2 3 4
FTC STP FTS STPD ST
J6
1 2 3 4 5 6 7 8 9 10
radio
nd
2
Aerial
cable
output
channel
lock
Electric
Blinker
ST.PED. NO
J5
FTSTP NC
STOP NC
24 Vac
Output
security devices
Common commands and
Capacitor
COM
M2
1 2
Electrochain or
courtesy light
1 2 3
4
J7
J3
Power regulator card
230 Vac 5A
F
Fuse mains power supply
1
1 2 3 4 5 6 7 8 9 10
F
N
230 Vac
Yellow-green
COM
CH AP AP
M1
CH
Ground
Capacitor
30
TABLE GENERALE
FRANCAIS
A Emploi de le tableau électronique……….
B Les limitations d’emploi……………………...
C Installation………………………………………….. D Fonctionnement………………………………….
D.1 Commandes……………………………………………. 33 D.2 Dispositifs de sécurité…………………………………. 33 D.3 Sorties…………………………………………………... 34 D.4 Alimentations…………………………………………… 34 D.5 Entrées/sorties accessoires…………………………… 34 D.6 Signaux optiques………………………………………. 34 D.7 Trimmer…………………………………………………. 35 D.8 Sélection des programmes……………………………. 35 D.9 Fusibles de protection…………………………………. 35 D.10 Caractéristiques techniques…………………………... 36 D.11 Logique de fonctionnement…………………………… 37 D.12 Caractéristiques électriques et mécaniques………… 39 D.13 Branchements électriques…………………………….. 39
32
32
33
33
E Entretien……………………………………………….
F Déclaration de conformité…………………….
G Programmation de la carte électronique H Schéma général……………………………………
43
43
44
45
31
FRANCAIS
A) – Les diverses plages d’application de le tableau électronique
Un tableau électronique pour commander 1 ou 2 moteurs asynchrones monophasés alimentés à 230 Vac tout à fait indiqué pour l’automation d’un portail à 1 ou 2 battants.
B) – Les limitations d’emploi
Attention : Avant de mettre en service le tableau électronique il faut s’assurer que les notes ci-dessous reportées aient bien été respectées. Note 1 - Lire attentivement et entièrement la documentation technique relative à la construction.
Note 2 - Le tableau électronique ne doit être installée que par un personnel qualifié en la matière il doit posséder toutes les capacités techniques et Note 3 - La tension d’ alimentation de le tableau électronique doit être égale à 230 Vac +/- 10%.
Note 4 - Le pôle N ( neutre ) de la tension d’ alimentation du réseau doit être équipotentielle avec la terre. Note 5 - Il faut obligatoirement observer toutes les règles en matière de sécurité relatives à l’installation des équipements électriques et
électroniques.
Note 6 - La tension d’alimentation du réseau doit nécessairement être fournie moyennant un interrupteur différentiel qui fonctionne bien, essayé et Note 7 - Avant d’installer l’équipement électronique il faut s’assurer que les moteurs qui sont assemblés à ce dernier, quand ils ont été alimentés
matière de sécurité et n’importe comment il doit être en mesure de ne pas provoquer des dommages en cas de heurts contre les choses, les Note 8 - Le tableau électronique ne doit être destinée qu’à l’emploi pour lequel elle a été expressément conçue ( consulter le point A). Tout autre
emploi doit être considéré comme étant contre-indiqué et par conséquent dangereux.
Note 9 - Avant d’agir sur le tableau électronique il faut s’assurer, qu’ à l’intérieur de la boîte dans laquelle elle est logée, la tension d’alimentation du Note 10 - Ne pas agir sur le tableau électronique avec les mains ou les pieds mouillés ou bien humides.
Note 11 - Ne pas laisser le tableau électronique exposée aux agents atmosphériques (la pluie, la neige etc…). Note 12 - Ne pas permettre que le tableau électronique soit manipulée par des enfants ou bien par des personnes incapables. Note 13 - Le tableau électronique doit être logée dans la boîte spéciale à cet effet. Note 14 - Le matériel plastique utilisé pour construire la boîte n’est pas auto-extinguible. Par conséquent il est nécessaire de l’installer dans un local
Note 15 - L'entretien ordinaire de l'unité électronique doit être exécuté par le personnel qualifié tous les 6 mois. Attention : Le non respect des notes ci-dessus indiquées peut causer des dommages aux personnes, aux animaux et aux choses, vis à vis
professionnelles nécessaires.
mis au point selon les réglementation prévues. avec la tension du réseau et mis en marche, ne produisent pas sur le portail une poussée supérieure à celle prévue par les règles en personnes ou les animaux.
réseau ne soit pas présente.
bien ventilé et loin des éléments qui pourraient donner origine aux flammes.
desquels le constructeur ne peut pas être retenu responsable.
32
FRANCAIS
C) – L’installation
1) Après avoir enlevé le couvercle en dévissant les vis spéciales à cet effet, s’assurer si tout l’équipement électronique est bien intact. En cas de
doute ne pas mettre en marche le tableau électronique et s’adresser à des personnes professionnellement qualifiées en la matière. Les
éléments accessoires de la boîte ( les vis, les joints, les chaumards) ne doivent pas être laissés à la portée des enfants car ce sont des
sources potentielles de danger.
2) S’assurer que l’équipement électronique soit correctement fixé à la boîte. Dans le cas contraire visser les vis desserrées ou bien ajouter les vis
qui manquent.
3) Positionner l’équipement électronique près du portail, afin de réduire au minimum la longueur des fils de jonction au reste de l’installation.
Attention :Pour que le tableau électronique fonctionne correctement la longueur des fils qui sont branchés à cette dernière ne doit
pas dépasser les 10 mètres.
4) Pour avoir une plus grande protection, il est conseillé de positionner le tableau électronique sous un toit ou bien et mieux encore, dans un
local qui dispose aussi de deux parois latérales. En outre il est souhaitable, là où cela est possible, d’installer l’équipement électronique à une
hauteur non inférieure à 1,5 mètre pour éviter toute manipulation de la part des enfants.
5) Avant de procéder à la fixation, orienter la boîte de façon à ce que la paroi qui contient les chaumards soit tournée vers la terre. Attention : Ne pas fixer la boîte sur des surfaces en bois.
6) Introduire le joint fourni avec l’équipement dans le siège spécial à cet effet en ayant soin que les deux extrémités se joignent dans la position
centrale de la paroi qui contient les chaumards.
7) Extraire la partie mobile de la boîte à bornes et effectuer le branchement des fils relatifs à l’installation comme cela est indiqué dans les
paragraphes suivants.
D) – Le fonctionnement
1) La définition des commandes
Start – (le dispositif pour faire partir l’ouverture/fermeture)
Il s’agit d’une entrée qui est reliée à un bouton -poussoir qui se trouve à l’extérieur de l’équipement électronique et qui sert à demander l’ouverture ou bien la fermeture du portail ( les deux battants). Normalement, à cette entrée on associe un bouton poussoir à clé.
Start de piéton ( le dispositif pour faire partir l’ouverture/fermeture pour les piétons)
Il s’agit d’une entrée qui est reliée à un bouton-poussoir qui se trouve à l’extérieur de l’équipement électronique et qui sert à demander l’ouverture ou bien la fermeture d’un seul battant du portail ( le battant pour les piétons), afin de ne permettre que le passage des personnes ou des animaux. .
2) La définition des dispositifs de sécurité
Stop - (Arrêt)
Il s’agit d’une entrée qui est reliée à un bouton-poussoir ou bien à un interrupteur qui se trouve à l’extérieur de l’équipement électronique avec lequel on détermine l’arrêt immédiat du portail. Cette commande ne doit être utilisée qu’en cas d’urgence.
La photocellule
Il s’agit d’une entrée qui est reliée à une barrière optique ayant pour objectif celui d’intercepter et de signaler le passage des personnes ou bien des voitures le long du parcours qui traverse le portail ou bien dans la zone qui se trouve près de ce dernier.
33
FRANCAIS
La photostop
Il s’agit d’une entrée qui est reliée à une barrière optique ayant pour objectif celui d’intercepter et de signaler le passage des personnes ou bien des voitures le long du parcours qui traverse le portail ou bien dans la zone qui se trouve près de ce dernier.
3) La définition des sorties
Le clignotant
C’est la commande on/off d’une lampe qui a pour objectif celui de prévenir et de signaler visuellement la condition de danger déterminée par le portail en mouvement.
Moteur 1
Il s’agit de sorties pour la commande d’ouverture/fermeture du moteur qui actionne le battant du portail qui le premier est en phase de fermeture.
Moteur 2
Il s’agit de sorties pour la commande d’ouverture/fermeture du moteur qui actionne le battant du portail qui en phase de fermeture est retardé. Normalement on place une serrure électrique sur ce battant.
La serrure électrique
C’est une commande impulsive pour que la serrure électrique se déclenche.
La lumière de service
C’est une commande continue pour la lampe qui éclaire la zone tout autour du portail. La lampe reste allumée pendant environ 2 minutes après la fin du cycle. Pendant la durée de la pause et quand le portail est ouvert la lampe reste toujours allumée et ce en mode automatique tandis qu’elle s’éteint en mode dénommé de copropriété.
L’électrochaîne
Il s’agit d’une commande continue pour que le verrou électrique se déclenche. La commande n’est habilitée que pendant le fonctionnement des moteurs.
4) La définition des alimentations
Le réseau 230 Vac
Il s’agit d’une entrée pour l’alimentation de la carte électronique.
La basse tension 24 Vac
Il s’agit d’une sortie pour l’alimentation des photocellules et/ou des autres éventuels dispositifs accessoires.
5) La définition des entrées/sorties accessoires
L’antenne
Il s’agit d’une entrée pour brancher une antenne radioréceptrice. Il ne faut l’utiliser que si une carte radioréceptrice est branchée à l’équipement électronique.
II° fonction radio
C’est une sortie de commande auxiliaire. Il ne faut l’utiliser que si une carte radioréceptrice à 2 fonctions est branchée à l’équipement électronique.
6) La définition des signaux optiques
LD6 - Led photocellule (jaune)
Il signale l’état de la barrière optique. Le led s’éteint quand la photocellule est obscurcie par le passage de personnes ou de voitures.
34
FRANCAIS
LD4 - Led photostop (jaune)
Il signale l’état de la barrière optique. Le led s’éteint quand la photocellule est obscurcie par le passage de personnes ou de voitures.
LD5 - Led stop (rouge)
Il signale l’état de blocage du portail. Le led s’éteint en recevant la commande de Stop (état d’urgence).
LD2 - Led start (vert)
Il s’allume en recevant la commande de Start.
LD3 - Led start de piéton (vert)
Il s’allume dès la réception de la commande de Start de piéton.
LD1 - Led d’alimentation (vert)
Il s’allume quand la carte électronique est alimentée.
7) La définition du trimmer
RV3 – Le travail
Cette fonction détermine le temps de fonctionnement des moteurs en ouverture ou bien en fermeture.
RV2 – Le retard M2
Cette fonction détermine le retard entre le départ du premier battant (M1) par rapport au second (M2) en phase de fermeture.
RV1 – La pause
Cette fonction détermine la durée de la pause du portail avant que s’effectue la fermeture automatique.
8) La définition du dip switch ( la sélection des programmes)
SW1 - Le dip switch 1 Il établit si le tableau électronique doit fonctionner avec la logique pas à pas ou bien en automatique: ON = En automatique OFF=Pas à Pas SW1 - Le dip switch 2
Il établit si le tableau électronique doit fonctionner avec la logique déterminée par le dip switch 1 ou bien en mode copropriété : ON= mode Copropriété OFF= sans aucune incidence.
SW1 - Le dip switch 3
Il autorise ou n’autorise pas à effectuer la procédure du coup de bélier pendant la phase d’ouverture quand le portail est fermé. ON=L’autorisation du coup de bélier OFF= sans aucune incidence
SW2 - Le Dip Fix
Il détermine le mode de fonctionnement de la commande à la sortie du connecteur auxiliaire J7. Le Dip fix fermé=en mode électrochaîne Le Dip Fix ouvert = en mode Lumière de service
9) La définition des fusibles de protection
F1 – Le fusible d’alimentation du réseau (5A)
Il débranche le tableau électronique de la ligne d’alimentation du réseau en cas de court-circuit ou d’anomalie en ce qui concerne la consommation de courant.
F2 – Le fusible de basse tension - services (2A)
Il protège le tableau électronique en cas de court-circuit ou de surintensité qui se seraient vérifiés sur les photocellules, sur la serrure électrique ou bien sur d’autres éventuels dispositifs accessoires auxiliaires branchés à la ligne d’alimentation 24 Vac.
35
FRANCAIS
10) Les caractéristiques techniques
Le régulateur de puissance
Le tableau électronique est conçue pour le branchement d’une éventuelle carte accessoire dénommée régulateur de puissance avec laquelle il est possible de réduire la puissance fournie aux moteurs.
Attention : En cas de panne ou bien d’anomalie de la carte régulateur de puissance il est possible que les moteurs, pendant le fonctionnement, travaillent avec la puissance au maximum. C’est pourquoi iI faut absolument respecter la note 7 qui est indiquée dans le paragraphe précédent au point « les limitations d’emploi » .
Le démarrage pour puissance maximum au départ
Le tableau électronique fournit, dès la mise en marche de n’importe quel moteur, la puissance maximum pendant environ 1 seconde, au terme de laquelle intervient l’éventuelle carte régulateur de puissance à laquelle il est branché. Cette caractéristique permet de surmonter le couple élevé négatif qui résiste au démarrage des moteurs.
Le Récepteur radio
Le tableau électronique a été conçue pour contenir un récepteur radio à 2 fonctions qui permet de commander à distance le portail à l’aide d’une radiocommande. La fonction 1 de la carte réceptrice radio est branchée à un contact électrique non polarisé (relais) directement connecté à l’entrée du Start. La fonction 2 de cette dernière et branchée à un contact électrique non polarisé (relais) directement relié à la sortie de la II° fonction radio. Cette sortie est normalement reliée à l’entrée du Start de piéton mais elle peut être employée pour d’autres applications.
Le clignotant
La carte électronique fournit une commande on/off (à allumage intermittent) à la lampe avec une logique qui permet de visualiser l’état de marche du portail. Feu clignotant rapide: il signale la phase d’ouverture. Feu clignotant lent : il signale la phase de fermeture. Feu fixe : il signale que le portail est arrêté pendant la durée de la pause qui précède la phase de fermeture en logique automatique. Le tableau électronique fournit à la lampe une commande d’allumage fixe, pendant environ 1,5 seconde, avant le départ des moteurs ( pré-alarme).
Le temps de travail
Le temps de fonctionnement des moteurs est contrôlé par deux Timers digitaux indépendants. Pour avoir un fonctionnement correct de l’automation il faut afficher le temps de travail de façon à ce qu’il soit légèrement supérieur (2 secondes minimum) au temps réel de course du portail. Si une quelconque commande interrompt la course du battant avant la fin, le Timer s’arrête et le temps qui s’est écoulé est mémorisé. Le tableau électronique est donc en mesure d’établir, avec une certaine approximation, le temps de travail partiel nécessaire pour faire terminer la course du battant. Cette caractéristique empêche au moteur d’être alimenté pendant une longue période après la fin de la course, en réduisant ainsi au minimum l’effet de surchauffage.
Très Important : Le manque d’alimentation à la carte électronique provoque la perte de la position mémorisé.
36
FRANCAIS
Le coup de bélier
Il est possible d’autoriser ou de ne pas autoriser la réalisation de la procédure du coup de bélier. Normalement on l’utilise pour faciliter le déclenchement de la serrure électrique quand il fait mauvais temps, quand il y a du vent, quand il gèle etc... La procédure du coup de bélier consiste en une séquence logique qui actionne la serrure électrique pendant une phase de fermeture brève (1 seconde environ) avec le portail fermé et la met hors service seulement après le départ du battant en phase d’ouverture.
Le déphasage des battants pendant l’ouverture Le tableau électronique impose un retard fixe d’environ 2 secondes entre le départ du premier battant (M2) par rapport au second (M1) au cours de la phase d’ouverture du portail et ce n’importe où il se trouve. Il est possible de mettre à zéro ce retard en réglant au minimum le Trimmer relatif au
déphasage. Très Important : Quand le tableau électronique est utilisé sur le battant unique il est nécessaire réglage au minimum le Trimmer relatif au
déphasage.
Introduction
L’équipement électronique contient un microprocesseur qui gère la logique de fonctionnement du portail. Pendant le fonctionnement on distingue trois phases principales :
La phase qui précède le mouvement
La phase au cours de laquelle le portail effectue le mouvement
La phase au cours de laquelle le portail effectue la pause (ouvert) Le tableau électronique peut gérer trois logiques de fonctionnement différentes:
Celle du Pas-à-pas – On l’obtient en positionnant les dip switch 1=OFF 2 =OFF Celle Automatique – On l’obtient en positionnant les dip switch 1=ON 2=OFF Celle dite de Copropriété - On l’obtient en positionnant les dip switch 1= sans aucune incidence 2=ON
La logique de fonctionnement dite de Copropriété est prioritaire. Si l’on sélectionne plusieurs logiques en même temps ce sera celle prioritaire qui sera mise en service.
37
FRANCAIS
Attention : L’affichage de la logique de fonctionnement (dip switch) tout comme la programmation des temps de travail et de pause doivent être
effectués seulement quand le cycle de travail est terminé ou bien quand il doit commencer (le portail doit être fermé). Le cycle de fonctionnement de l’ouverture ou bien de la fermeture est mis en marche par une commande de Start. Très important : La première commande de Start fournie après avoir alimenté la carte électronique détermine toujours le démarrage d’un cycle
d’ouverture quelque soit la logique sélectionnée.
La logique du pas-à-pas
Après avoir fourni la tension d’alimentation à la carte électronique, la première commande de Start fait commencer un cycle d’ouverture. Le temps de travail écoulé pour les deux moteurs la course est terminée et le portail s’arrête. Le cycle de travail est complété (le clignotant est éteint) en attendant une nouvelle commande de Start pour la fermeture. En fournissant une commande de Start quand la course n’est pas finie le portail s’arrête. Une commande successive de Start détermine l’inversion du mouvement.
La logique automatique
Après avoir fourni la tension d’alimentation à la carte électronique, la première commande de Start fait commencer un cycle d’ouverture. Le temps de travail écoulé pour les deux moteurs la course est terminée et le portail s’arrête en faisant commencer le temps de la pause (le clignotant avec la lumière fixe). Le temps de la pause écoulé le portail se ferme automatiquement. Le cycle de travail est complété à la fin de la phase de fermeture (le clignotant est éteint). En fournissant une commande de Start quand la course n’est pas finie le portail s’arrête. Une commande successive de Start détermine l’inversion du mouvement. Une commande de Start fournie pendant le temps de pause interrompt le cycle du travail (le clignotant est éteint) et le portail ne se ferme pas automatiquement. Une commande successive de Start met en route un cycle de fermeture.
La logique dite de copropriété
Après avoir fourni la tension d’alimentation à la carte électronique, la première commande de Start fait commencer un cycle d’ouverture. Le temps de travail écoulé pour les deux moteurs la course est terminée et le portail s’arrête en faisant commencer le temps de la pause (le clignotant est éteint). Le temps de la pause écoulé, le portail se ferme automatiquement. Le cycle de travail n’est complété qu’à la fin de la phase de fermeture. Une commande de Start fournie pendant la phase d’ouverture est sans incidence. Une commande de Start fournie pendant la phase de fermeture provoque l’arrêt ainsi que l’inversion de marche après 1,5 seconde environ. Une commande de Start fournie pendant le temps de pause recharge ce dernier en prolongeant le temps qui précède la fermeture automatique. Très important : Si l’ouverture du portail est commandée par une horloge il faut nécessairement mettre en service la logique de fonctionnement dite de copropriété.
REMARQUE : Au début de chaque cycle d’ouverture la serrure électrique est actionnée pendant quelques dixièmes de seconde (0,8 sec.) avant le démarrage du premier battant (M2) et elle est désactivée quelques dixièmes de seconde (0,4 sec.) après le départ de ce dernier. Cette séquence n’est valable que si le dip switch 3 se trouve en position OFF.
Quelque soit la logique de fonctionnement utilisée, l’intervention des dispositifs de sécurité produit les effets décrits ci-dessous : Stop : Si la commande Stop est mise en service, elle empêche le démarrage de n’importe quel cycle et rend la commande Start sans incidence. Une
commande Stop fournie pendant le mouvement provoque l’arrêt immédiat du portail en interrompant le cycle de travail. Cette condition persiste jusqu’à ce qu’elle reste présente. Après une commande Stop, la commande successive de Start fait toujours partir un cycle d’ouverture. Une commande Stop fournie pendant le temps de la pause interrompt le cycle de travail. La commande successive de Start fait commencer un cycle de fermeture.
38
FRANCAIS
La photocellule : Elle a de l’influence seulement pendant la phase de fermeture ou pendant la durée de la pause. Si un obstacle obscurcit la
photocellule pendant la fermeture, il provoque l’arrêt et l’inversion de marche après environ 1,5 seconde. L’intervention de la photocellule pendant le temps de la pause recharge cette dernière en prolongeant le temps qui précède la fermeture automatique.
Le photostop: Si un obstacle obscurcit la cellule photoélectrique pendant le mouvement, quelque soit le sens de marche, ou au cours de la phase qui précède le démarrage du cycle de travail, il provoque l’arrêt temporaire du portail jusqu’à ce qu’il reste dans cet état. Le feu clignotant signale avec la lumière fixe la condition anormale. Dès que l’obstacle est enlevé et que la photocellule est libre un cycle d’ouverture commence toujours. Cette condition n’est pas valable quand une commande de Start fait partir la phase de fermeture en logique pas-à-pas et le portail est ouvert. L’intervention du photostop pendant le temps de la pause recharge cette dernière en rallongeant le temps qui précède la fermeture automatique.
Le Start de piéton : La commande Start de piéton agit de la même façon que l’autre commande de Start mais elle ne détermine que l’ouverture ou la fermeture du battant (M2) qui porte la serrure électrique. La commande Start de piéton n’a aucune incidence pendant le cycle de Start jusqu’à la fin de la phase de fermeture ( portail fermé). Au cours d’un cycle de Start de piéton la commande relative au Start es toujours en service.
12) Les caractéristiques électriques et mécaniques
Dimensions et Poids : 177 x 247 x 92 mm - 1,2 Kg Alimentation générale : 230 Vac +/- 10% Puissance absorbée au repos : 1 W environ Température de fonctionnement : de 0 à + 60 °C Alimentation des moteurs monophasés : 230 Vac 1 HP max Alimentation du clignotant : 230 Vac 40 W max Alimentation de la lumière de service : 230 Vac 40 W max Alimentation de la serrure électrique : 12 Vac 15 W max Alimentation des accessoires : 24 Vac 6 W max Caractéristiques du contact relais II° fonction radio : 24 Vac 0,5 A max Réglage du temps de travail des moteurs: de 0 à 100 secondes Réglage du temps de pause : de 2 à 100 secondes Réglage du déphasage (retard du moteur M2) : de 0 à 25 secondes
Attention : Ne pas mettre en marche le tableau électronique si les charges électriques qui sont connectées à elle ou bien si la tension d’alimentation
ne rentrent pas dans les valeurs limites ci-dessus indiquées. Le non respect peut causer des dommages aux personnes, aux animaux et aux choses, vis à vis desquels le constructeur ne peut pas être considéré responsable.
13) Les branchements électriques
Sur la carte on distingue 6 connecteurs électriques :
1) J5 Une boîte à bornes ayant 10 pôles pour le branchement des dispositifs qui fonctionnent avec la tension de réseau 230 Vac (les moteurs, le clignotant et le câble du réseau).
2) J6 Une boîte à bornes ayant 10 pôles pour le branchement des dispositifs qui fonctionnent en basse tension ( les commandes, les dispositifs de sécurité, l’électroserrure et la sortie de l’alimentation 24 Vac).
39
FRANCAIS
3) J4 Une boîte à bornes ayant 4 pôles pour le branchement des éléments auxiliaires qui fonctionnent en basse tension (la sortie de la
II° fonction radio et l’antenne).
4) J7 Une boîte à bornes ayant 2 pôles pour le branchement des éléments auxiliaires qui fonctionnent avec la tension du réseau 230 Vac (la lumière de service ou l’électro-chaîne ).
5) J3 Un connecteur ayant 4 pôles pour le branchement d’une éventuelle carte pour la régulation de la puissance.
6) J2 Un connecteur ayant 10 pôles pour le branchement d’une éventuelle carte réceptrice radio. Boîte à bornes J5
Borne 1 – La phase d’alimentation du réseau à 230 Vac Borne 2 – Le neutre d’alimentation du réseau à 230 Vac Attention : Les polarités de la tension d’alimentation doivent être rigoureusement respectées. Borne 3 – La phase ouverture d’alimentation à 230 Vac moteur M1 Borne 4 – La phase fermeture d’alimentation à 230 Vac moteur M1 Borne 5 – Commune d’alimentation à 230 Vac moteur M1 REMARQUE: Brancher le condensateur du moteur M1 entre les bornes 3 et 4 Borne 6 – La phase ouverture d’alimentation à 230 Vac moteur M2 Borne 7 – La phase fermeture d’alimentation à 230 Vac moteur M2 Borne 8 – Commune d’alimentation à 230 Vac moteur M2 REMARQUE: Brancher le condensateur du moteur M2 entre les bornes 6 et 7 Borne 9 – La phase d’alimentation à 230 Vac clignotant Borne 10 – Le neutre d’alimentation à 230 Vac clignotant
Boîte à bornes J6 Borne 1 – Alimentation à 12 Vac pour la serrure électrique Borne 2 – Alimentation à 12 Vac pour la serrure électrique (commune) Borne 3 – Alimentation à 24 Vac pour la photocellule ou d’autres dispositifs (commune) Borne 4 – Alimentation à 24 Vac pour la photocellule ou d’autres dispositifs Borne 5 – Une borne commune à tous les contacts électriques relatifs aux commandes ou bien aux dispositifs de sécurité Borne 6 – Un contact électrique normalement fermé de la photocellule Borne 7 – Un contact électrique normalement fermé du bouton poussoir de Stop Borne 8 – Un contact électrique normalement fermé de la cellule photo-électrique (photostop) Borne 9 – Un contact électrique normalement ouvert du bouton poussoir de Start Borne 10 – Un contact électrique normalement ouvert du bouton poussoir de Start de piéton Très important : Les entrées normalement fermées doivent être équipées de ponts électriques si elles ne sont pas utilisées. )
40
FRANCAIS
Boîte à bornes J4 Borne 1 – Le contact électrique normalement ouvert de la II° fonction radio (sortie) Borne 2 – Le contact électrique normalement ouvert de la II° fonction radio (sortie) Borne 3 – L’entrée de l’antenne (gaine) Borne 4 – L’entrée de l’antenne (signal)
Boîte à bornes J7 Borne 1 – La phase d’alimentation à 230 Vac pour la lumière de service ou bien l’électro-chaîne Borne 2 – Le neutre d’alimentation à 230 Vac pour la lumière de service ou bien l’électro-chaîne
Connecteur J3 Borne 1 – Commune d’alimentation à 230 Vac moteurs M1 et M2 Borne 2 – Commune d’alimentation à 230 Vac moteurs M1 et M2 Borne 3 – Commune d’alimentation à 230 Vac moteurs M1 et M2 Borne 4 – Le neutre d’alimentation du réseau à 230 Vac Très important : Si l’on ne branche pas la carte régulatrice de puissance il faut obligatoirement effectuer des ponts électriques avec les bornes 3 et 4 du connecteur J3 en se servant d’un faston isolée de 4 mm.
Connecteur J2 Borne 1 – Le contact électrique normalement ouvert branché au Start Borne 2 – Le contact électrique normalement ouvert branché au Start (commun) Borne 3 – Le contact électrique normalement ouvert branché au la sortie II° fonction radio Borne 4 – Le contact électrique normalement ouvert branché au la sortie II° fonction radio Borne 5 – L’alimentation à 24 Vac (commun) Borne 6 – L’alimentation à 24 Vac Borne 7 – L’alimentation à 24 Vac Borne 8 – L’alimentation à 24 Vac (commun) Borne 9 – L’entrée de l’antenne (gaine) Borne10 - L’entrée de l’antenne (signal)
41
FRANCAIS
La connexion des dispositifs
Le câble d’alimentation du réseau à 230 Vac et terre - Les bornes 1,2 de J5 Attention : Ie pôle de la terre du câble doit obligatoirement être connecté à une bonne référence de terre qui se trouve près du portail.
Moteur 1 – Bornes 3,4 et 5 de J5 Moteur 2 – Bornes 6,7 et 8 de J5 Clignotant - Bornes 9 et 10 de J5 Serrure électrique - Bornes 1 et 2 de J6 Alimentation des photocellules - Bornes 3 et 4 de J6 Contact de la photocellule NC - Bornes 5 et 6 de J6 Bouton poussoir de Stop NC - Bornes 5 et 7 de J6 Contact du photostop NC - Bornes 5 et 8 de J6 Bouton poussoir de Start de piéton NO - Bornes 5 et 9 de J6 Bouton poussoir de Start NO – Bornes 5 et 10 de J6 Antenne – Bornes 3 et 4 de J4 Lumière de service – Bornes 1 et 2 de J7 Electro-chaîne – Bornes 1 et 2 de J7
Très important : Avant de faire démarrer le portail vérifier si les connexions à la carte électroniques sont correctes. Pour cela vérifier aussi la commutation des contacts électriques signalée par l’allumage et/ou la coupure des leds.
42
FRANCAIS
E) ENTRETIEN
Attention: L'entretien du dispositif doit être effectué seulement et exclusivement par un technicien spécialisé autorisé du fabricant.
N'importe quelle opération de l'entretien ou contrôle du dispositif doit être effectuée en l'absence de l'alimentation électrique.
Entretien ordinaire: Chaque fois qu'il est nécessaire et cependant tous les 6 mois est recommandée pour vérifier le fonctionnement du dispositif. Entretien extraordinaire: En cas de panne, enlever le dispositif et envoyer-le pour la réparation au laboratoire du fabricant ou au laboratoire autorisé.
Le fabricant ne peut pas être considéré responsable du manque d'observance des règles au-dessus de décrit.
F) DECLARATION DE CONFORMITE (Selon la directive EMC EN45014 et le modèle 22 de l’ISO)
Raison sociale et siège du fabricant : Leb electronics s.r.l. Via Valle Maria , 55/a 46040 Casalmoro (MN) Italie
Description de le tableau électronique : Il s’agit d’un Tableau électrique en mesure de commander 1 ou 2 moteurs asynchrones monophasés à 230 Vac pour l’automation d’un portail.
Modèle : CTR17.04 Normes de référence appliquées : EN 50081-1, EN 50082-1, EN 55014 Normes de base appliquées : EN 61000-3-2, EN 61000-3-3, EN 61000-4-4, EN 61000-4-2, ENV 50140 Laboratoire pour l’essai : Intek s.p.a Résultat : Positif Le fabricant déclare que les produits ci-dessus indiqués sont conformes aux réglementations prévues par les directives 89/336/EEC, 92/31/EEC,
93/68/EEC sur la compatibilité électromagnétique.
Casalmoro , 01-01-2000
43
FRANCAIS
G) Programmation de la carte électronique
Logique Pas-à-Pas La logique de copropriété
ON OFF
3 2 1
Positionner les dip switch 1 et 2 sur OFF L’état de dip switch 3 n’a aucune incidence
ON OFF
3 2 1
L’état de dip switch 1 n’a aucune incidence Positionner le dip switch 2 sur ON L’état de dip switch 3 n’a aucune incidence
Logique Automatique Logique coup de bélier
ON OFF
3 2 1
Positionner le dip switch 1 sur ON Positionner le dip switch 2 sur OFF L’état de dip switch 3 n’a aucune incidence
ON OFF
3 2 1
L’état de dip switch 1 n’a aucune incidence L’état de dip switch 2 n’a aucune incidence Positionner le dip switch 3 sur ON
Logique électro-chaîne / lumière de service
SW2 Ouvert SW2 Fermé
Pour lancer la logique Lumière de service ouvrir le switch SW2.
Pour lancer la logique électro-chaine fermer le switch SW2.
44
Schéma général
FRANCAIS
START NO
LD1
Alimentation
Réglage Timer
RV3 RV2 RV1
Travail Retard M2 Pause
1 2 3 4 5 6 7 8 9
J2
3 2 1
SW1
SW2
F
2
24Vac 2A
Fusible B.T.
10
Radio-récepteur
LD6 LD5 LD4 LD3 LD2
Dip switch
Signaux optiques
Sélection des programmes
J4
1 2 3 4
FTC STP FTS STPD ST
J6
1 2 3 4 5 6 7 8 9 10
ANT
SORTIE II°
FONCTION RADIO
SERRURE
ELECTRIQUE
LAMP
ST.PIET. NO
J5
1 2 3
1 2
J7
électro-chaine
Lumière de service ou
J3
puissance
Régulateur de
4
230 Vac 5A
F
Fusible de réseau
1
1 2 3 4 5 6 7 8 9 10
F
N
230 Vac
JAUNE-VERT
FTSTP NC
SORTIE
STOP NC
FOTOC NC
Commune commandes et
dispositifs de sécurité
24 Vac
COND
AP
COM
M2
CH AP
COM
M1
CH
TERRE
COND
45
46