IMPORTANT: This manual contains information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer. The entire manual
should be carefully read.
FCC COMPLIANCE STATEMENT
Telephone
Computer
Telephone
Telephone
Fax Machine
Alarm Dialing
Equipment
RJ-31X
Jack
Unused
RJ-11 Jack
Telephone
Line
Network
Service
Provider's
Facilities
Customer Premises Equipment and Wiring
Unused
RJ-11 Jack
Network
Demarcation
Point
Answering
System
CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interfer-ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult a dealer or experienced radio/television technician for help.
The user may find the following booklet prepared by the FCC useful: "How to
Identify and Resolve Radio/Television Interference Problems". This booklet is
available from the U.S. Government Printing Office, Washington D.C. 20402,
Stock # 004-000-00345-4.
IMPORTANT INFORMATION
This equipment complies with Part 68 of the FCC Rules and, if the product was
approved July 23, 2001 or later, the requirements adopted by the ACTA. On the
top side of this equipment is a label that contains, among other information, a
product identifier. If requested, this number must be provided to the Telephone
Company.
Product Identifier:US:F53AL01B9155
USOC Jack:RJ-31X
Telephone Connection Requirements
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is
provided with this product. It is designed to be connected to a compatible modular jack that is also c ompliant. See installation instruction s for details.
Ringer Equivalence Number (REN)
The REN is used to determine the number of devices that may be connected to
a telephone line. Excessive RENs on a telephone line may result in the devices
not ringing in response to an incoming call. In most but not all areas, the sum of
RENs should not exceed five (5.0). To be certain of the number of devices that
may be connected to a line, as determined by the total RENs, contact the local
Telephone Company. For products approved after July 23, 2001, the REN for
this product is part of the product identifier that has the format US:
AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately
shown on the label. REN = 0.1B
Incidence of Harm
If this equipment (PC9155-433) causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of
service may be required. But if advance notice is not practical, the Telephone
Company will notify the customer as soon as possible. Also, you will be advised
of your right to file a complaint with the FCC if you believe it is necessary.
Changes in Telephone Company Equipment or Facilities
The Telephone Company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the Telephone Company will provide advance notice in order for you to
make necessary modifications to maintain uninterrupted service.
Equipment Maintenance Facility
If trouble is experienced with this equipment (PC9155/WT5500) for repair or
warranty information, contact the facility indicated below. If the equipment is
causing harm to the telephone network, the Telephone Company may request
that you disconnect the equipment until the problem is solved. This equipment
is of a type that is not intended to be repaired by the end user.
DSC c/o APL Logistics 757 Douglas Hill Rd., Lithia Springs, GA 30122
Additional Information
Connection to party line service is subject to state tariffs. Contact the state public
utility commission, public service commission or corporation commission for
information.
Alarm dialling equipment must be able to seize the telephone line and place a
call in an emergency situation. It must be able to do this even if other equipment
(telephone, answering system, computer modem, etc.) already has the telephone
line in use. To do so, alarm dialling equipment must be connected to a properly
installed RJ-31X jack that is electrically in series with and ahead of all other
equipment attached to the same telephone line. Proper installation is depicted in
the figure below. If you have any questions concerning these instructions, you
should consult your telephone company or a qualified installer about installing
the RJ-31X jack and alarm dialling equipment for you.
INDUSTRY CANADA STATEMENT
NOTICE: This product meets the applicable Industry Canada technical specifications.
Le présent materiel est conforme aux specifications techniques applicables d’Industrie Canada.
The Ringer Equivalence Number (REN) for this terminal equipment is 0.1.
L'indice d'équivalence de la sonnerie (IES) du présent m atériel est de 0.1.
The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a telephone int erface. The termination on an interface may consist of any combination of devices sub ject only to the
requirement that the sum of the RENs of all the devic es does not exceed five.
L’indice d’équivalence de la sonnerie
(IES) sert à indiquer le nombre maximal de terminau x qui peuvent être raccordés
à une interface téléphonique. La terminai son d’une interface peut consister en
une combinaison quelconque de dispositifs, à la seule co ndition que la somme
d’indices d’équivalence de la sonnerie de tous les disp ositifs n’excède pas 5.
The term "IC:" before the radio certification number only signifies that Industry
Canada technical specifications were met.
Certification Number IC: 160A-PC9155
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du
Canada.
Carbon Monoxide Alarm (for future use, to be activated by your installer) 4
Time & Date Programming 4
Bypassing Zones 5
Trouble Conditions 6
Alarm Memory 6
Door Chime 7
Access Code Programming 7
Keypad Quick Guide 16
Guidelines for Locating Smoke & CO Detectors 18
Household Fire Safety Audit 20
Fire Escape Planning 20
i
Always ensure you obtain the latest version of the User Guide. Updated versions of this
User Guide are available by contacting your distributor.
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electric shock and/or injury, observe the following:
• Do not spill any type of liquid on the equipment.
• Do not attempt to service this product yourself. Opening or removing the cover may
expose you to dangerous voltage or other risk. Refer servicing to qualified service personnel. Never open the device yourself.
• Do not touch the equipment and its connected cables during an electrical storm; there
may be a risk of electric shock from lightning.
• Do not use the Alarm System to report a gas leak if the system is near a leak.
REGULAR MAINTENANCE AND TROUBLESHOOTING
Keep your Alarm Controller in optimal condition by following all the instructions that are
included within this manual and/or marked on the product.
CLEANING
• Clean the units by wiping with a damp cloth only.
• Do not use abrasives, thinners, solvents or aerosol cleaners (spray polish) that may enter
through holes in the Alarm Controller and cause damage.
• Do not use any water or any other liquid.
• Do not wipe the front cover with alcohol.
TROUBLESHOOTING
Occasionally, you may have a problem with your Alarm Controller or telephone line. If this
happens, your Alarm Controller will identify the problem and displays an error message.
Refer to the provided list when you see an error message on the display. If additional help
is required, contact your distributor for service.
WAR NING: This equipment, PC9155 Alarm System shall be installed and used within an
environment that provides the pollution degree max 2 and over-voltages category II nonhazardous locations, indoor only. It is designed to be installed, serviced and/or repaired by
service persons only [service person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be
exposed in performing a task and of measures to minimize the risks to that person or other
persons]. For EU and Australian markets, the equipment is permanently connected; an
accessible disconnect device shall be incorporated into the building installation wiring. For
North America the equipment is a direct plug-in connection; the socket outlet shall be
installed near the PC9155 and shall be easily accessible. The plug of the direct plug-in
transformer serves as the disconnect device.
NOTE: There are no parts replaceable by the end-user within this equipment, except for the
keypad batteries and the WT4901/8901 batteries.
This publication covers the following models:
• PC9155-433
• PC9155D-433
• PC9155G-433
• PC9155-868
NOTE: The 868 MHz models are not UL/ULC listed.
NOTE: Only these models shall be used with UL/ULC listed systems: PC9155-433,
PC9155D-433, PC9155G-433, PC9155I-433, WT5500P-433, WT5500-433, WT4901,
WT4989, WT4911 and PT4.
NOTE: Only certain models of Alexor include the SMS features. Check with your installer.
Read this manual carefully and have your installer instruct you on your system's operation and on
which features have been implemented in your system. All users of this system should be fully
instructed in its use. Fill out the "System Information" page with all of your zone information and access
codes, and store this manual in a safe place for future reference.
NOTE: Please consult your installer for further information regarding the false alarm reduction features
built into your system, as not all are covered in this manual.
Fire Detection (must be enabled by Installer)
This equipment is capable of monitoring fire detection devices such as smoke detectors and providing
a warning if a fire condition is detected. Good fire detection depends on having an adequate number
of detectors placed in appropriate locations. This equipment should be installed in accordance with
NFPA 72 (N.F.P.A., Batterymarch Park, Quincy MA 02269). Please read the Family Escape Planning
guidelines in this manual.
Carbon Monoxide Detection (must be enabled by Installer)
This equipment is capable of monitoring carbon monoxide detectors and providing a warning if carbon
monoxide is detected. Please read the Family Escape Planning guidelines in this manual and instructions that are available with the carbon monoxide detector.
Testing
To ensure that your system continues to function as intended, you must test your system weekly.
Please refer to the “Testing your System" section in this manual. If your system does not function
properly, call your installing company for service.
Monitoring
This system is capable of transmitting alarms, troubles, and emergency information to a central
station. If you initiate an alarm by mistake, immediately call the central station to prevent an
unnecessary response.
NOTE: The monitoring function must be enabled by the installer before it can become functional.
NOTE: This system has a communicator delay of 30 seconds. This function can be deleted, or it
can be increased up to a maximum of 45 seconds by the installer.
NOTE: Ensure that your installer verifies that your system is compatible with the Central Station
Receiver format at yearly intervals.
Maintenance
With normal use, the system requires minimum maintenance. Note the following points:
• Do not wash the security equipment with a wet cloth. Light dusting with a slightly moistened
cloth should remove normal accumulations of dust.
• The standby battery shall be replaced every 3-5 years by service persons only.
NOTE: Do not attempt to replace the battery or open the enclosure; there is a risk of electric
shock and/or fire.
• For other system devices such as smoke detectors, motion detectors, glassbreak detectors or
door/window contacts, consult the manufacturer’s literature for testing and maintenance
instructions.
General System Operation
Your security system includes an alarm control/keypad and various sensors and detectors. The
keypad is mounted by the main entry/exit location.
The security system has several zones of area protection. Each of these zones communicates to
a single wireless sensor (motion detectors, glassbreak detectors, door contacts, etc.) or to one
or more hard-wired sensors. A sensor in alarm is indicated by messages on the LCD.
Additional features include Automatic Inhibit (Swinger Shutdown) for Alarm; Tamper and Trouble
signals after 3 occurrences in a given set period; SMS Interactive operation; and a Programmable Keypad Lockout option.
For SIA CP-01 classified installations, the swinger shutdown feature is programmed such that
one or two trips will shut down the zone. The zone will be restored after a manual reset (by entering the access code at the time of disarming the alarm system) or it will be reset automatically
after 48 hours with no trips on any zones.
NOTE: Only the installer or service professional should have access to the system.
(*) The SMS feature was not investigated by UL/ULC.
1
Keypad Controls & Indicators
< > indicates user can
LCD
Ambient Light
Sensor
Scroll Keys
Emergency Keys
Fire
Auxiliary
Panic
scroll through options
System is
Ready to Arm
23
1
4
5
89
7
0
*
<>
6
#
LED Indicators
Ready
Armed
Trouble
AC Power
Function
Keys
DG009033
IMPORTANT NOTICE
A security system cannot prevent emergencies. It is only intended to alert you and your central
station (if applicable) to an emergency situation. Security systems are generally very reliable but
they may not work under all conditions and they are not a substitute for prudent security practices or life and property insurance. Your security system must be installed and serviced by qualified security professionals. These professionals can instruct you on the level of protection that
has been provided and on system operations.
NOTE: When the keypad is in “Sleep Mode” it is saving battery life e.g., backlighting, LCD
message display will not be turned on until there is a specific reason: a key is pressed, entry delay
is started. In this mode the keypad is still functioning but nothing will be visible except the Armed
LED (when activated). Check with your installer.
Language Selection
Your system can display messages in different languages.
1. Press and hold both buttons simultaneously for 2 seconds.
2. Using the buttons, scroll through the available languages.
3. Press to select your desired language.
Arming and Disarming the System
Stay Arming
Stay arming will bypass the interior protection (i.e., motion sensors) and arm the perimeter of the
system (i.e., doors and windows). Close all sensors (i.e., stop motion and close doors). The
Ready ( ) indicator will illuminate.
Press and hold the Stay button until it beeps (approx. 2 seconds), enter your access code
or present your prox tag; do not leave the premises. During the setting state (exit delay active),
the Armed ( ) and Ready ( ) indicators will illuminate.
When the exit delay is completed, the alarm system is armed/set and this is indicated on the
keypad as follows: the Ready ( ) indicator will turn off, the Armed ( ) indicator will remain on.
The Armed ( ) indicator and a bypass message will be displayed. The system will automatically ignore bypassed zones (i.e., motion sensors).
NOTE: For SIA CP-01 listed panels, the Stay Arming Exit Delay will be twice as long as the Away
Arming Exit Delay.
NOTE: If your system is installed in accordance with SIA CP-01 Standard for False Alarm
Reduction, then the security system will arm in the Stay Armed mode if the exit delay time expires
and no exit has been made.
Night Arming
To night arm the system when it has been armed in Stay Mode, press at the keypad. All
interior zones will now be armed except for devices programmed as Night Zones.
NOTE: Your installer can also program a function key on the keypad to allow you to arm the
system in Night Mode. This allows Night Arming to be activated by holding down the function key
for 2 seconds.
2
Night zones are only armed in Away mode; this permits limited movement within the premises
when the system is fully armed. Ensure that your installer has provided you with a list identifying
zones programmed as night zones.
When the interior zones are activated (i.e., ) you must enter your access code or pres-
ent your proximity tag to disarm the system in order to gain access to interior areas that have not
been programmed as night zones.
Silent Exit Delay
If the system is armed using the Stay button or using the "No Entry" Arming method (
[Access Code]), the keypad buzzer will be silenced and the exit time will be doubled for that exit
period only.
Away Arming
Close all sensors (i.e., stop motion and close doors). The Ready ( ) indicator should be on.
To arm, press and hold the Away button for 2 seconds and/or enter your access code, present
your prox tag or press to Quick Arm.
During the setting state (exit delay active) the Armed ( ) and Ready ( ) indicators will turn on,
and the keypad will sound one beep per second. You now have ___ seconds to leave the premises (please check with your installer to have this time programmed). A keypad buzzer, whose
pulsating rate is distinct, will sound during the last ten seconds of the exit delay to warn person(s) that the exit delay is running out. To cancel the arming sequence, enter your access code
or present your prox tag.
When the exit delay is completed, the alarm system is armed and this is indicated on the keypad
display as follows: the Ready ( ) indicator will turn off, the Armed ( ) indicator will remain on
and the keypad will stop sounding.
The system can also be armed/disarmed with a wireless key and with prox tags. Refer to the
‘Proximity Tags" and ‘Two-Way Wireless Key" sections for more details.
NOTE: If your system is installed in accordance with SIA CP-01 Standard for False Alarm
Reduction, the following holds true: Violation and restoral, followed by a second violation of the
entry/exit zone before the end of the exit delay, will restart the exit delay.
Quick Exit
If the system is armed and you need to exit, use the Quick Exit function to avoid disarming and
rearming the system. Press and hold the Quick Exit button for 2 seconds or press .
You now have 2 minutes to leave the premises. When the door is closed again, the remaining
exit time is cancelled.
Siren Sounds After Away Arming
Audible Exit Fault
In order to reduce false alar
ms, the Audible Exit Fault is designed to notify you of an improper
exit when arming the system. If you fail to securely close the entry/exit door during the programmed exit delay period, the system will sound the alarm to indicate an improper exit (your
installer will tell you if this feature has been enabled on your system). If this occurs:
1. Re-enter the premises.
2. Enter your access code or present your prox tag, before the entry delay timer expires, to dis-
arm the system.
3. Repeat the Away arming procedure, ensuring that the entry/exit door(s) are secured.
Arming Error
An error tone will sound if the system is unable to arm. This will happen if the system is not ready
to arm (i.e., sensors are open), or if an incorrect user code has been entered. If this happens,
ensure all sensors are secure, press and try again.
Disarming
To disarm an armed system (Armed ( ) indicator is On), enter your access code or present your
prox tag. If your keypad is in sleep mode, press any key to wake it up then enter your access
code/present prox tag. The keypad will sound a continuous tone after the entry delay has been
initiated by opening the entry/exit door. Enter your code within _______ seconds to avoid an
alarm condition (check with your installer to have this time programmed).
3
Disarming Error
HH:MM MM/DD/YY
09:06 01/31/10
If your code/prox tag is invalid, the system will not disarm and a 2-second error tone will sound. If
this happens, press and try again.
Remote Arming and Disarming
The system can be armed and/or disarmed, if programmed by the installer, using a remote control
device (wireless key). When arming the system using the Arm button on a wireless key, the system
will acknowledge the command by sounding a single bell/siren squawk, if programmed to do so by
the installer. When disarming using the Disarm button on a wireless key, the system will acknowledge the command by sounding two bell/siren squawks. Three squawks, when disarming with the
Disarm button, indicates that an alarm occurred while the system was armed. If you are unsure of
the cause of the alarm, proceed with caution (see section on 2-way Wireless Keys).
Emergency Keys
Press the (Fire), (Auxiliary), or (Panic) button for 2 seconds to generate a Fire,
Auxiliary, or Panic alarm. The keypad buzzer will beep indicating that the alarm input has been
accepted and transmission to the central station is underway. The button may or may not
sound the siren depending on installer setup.
NOTE: The Fire button can be disabled by the installer.
NOTE: The Auxiliary Alarm button is not intended to be used for medical signals.
When Alarm Sounds
The system can generate 3 different alarm sounds:
• Continuous Siren = Intrusion/Burglary Alarm
NOTE: The WT4911 siren will sound a dual frequency sweeping tone for burglary alarms.
NOTE: The priority of signals is fire alarm, carbon monoxide alarm then burglary alarm.
Intrusion (Burglary) Alarm Continuous Siren
If you are unsure of the source of the alarm, proceed with caution! If the alarm was accidental,
enter your access code or present your prox tag to silence the alarm. If the alarm system is disarmed within the programmed Abort Window (check with the installer if this option has been enabled on your system and what is the transmitter delay time programmed), no alarm transmission
to the Central Station will occur. Following the Abort Window there appears a 5-minute Cancel
Window, during which a user can cancel, by entering their access code or presenting their prox
tag, an alarm that has been previously transmitted. A cancel signal will be transmitted to the central station and the alarm system will also announce that the cancel signal was transmitted. Call
your central station to avoid a dispatch.
Fire Alarm Pulsed Siren
Follow your emergency evacuation plan immediately!
If the fire alarm was accidental (burned toast, bathroom steam, etc.), enter your access code or
present your prox tag to silence the alarm. Call your central station to avoid a dispatch.
Carbon Monoxide Alarm (for future use, to be activated by your installer)
Activation of your CO alarm indicates the presence of carbon monoxide (CO), which can be
fatal. During an alarm, the red LED on the CO detector flashes rapidly and buzzer sounds with a
repeating cadence of: 4 quick beeps, 5-second pause, 4 quick beeps. If an alarm sounds:
1. Operate silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.
WARNING: Carefully review your Carbon Monoxide Installation/User Guide to determine the necessary actions required to ensure your safety and ensure that the equipment is operating correctly.
Incorporate the steps outlined in the guide into your evacuation plan.
Time & Date Programming
Press then your master access code to enter User
Functions. Use the buttons to find the menu option,
then press to select. Enter the time in 24-hr. format
4
(HH:MM), followed by the date (MM:DD:YY). Press to exit programming. If you are viewing a
Zone Bypass
‘Loss of Clock" trouble from within the trouble menu (), press to directly enter Date
and Time programming (see Trouble Conditions).
NOTE: Your installer may have programmed your system to display the time and date while the
keypad is idle. Press the button to temporarily clear the date and time display if desired.
Bypassing Zones
Use the zone bypassing feature when you need access to a protected area while the system is
armed, or when a zone is temporarily out of service but you need to arm the system. Bypassed
zones will not be able to sound an alarm. As a result, bypassing zones reduces the level of
security. If you are bypassing a zone because it is not working, call a service technician immediately so that the problem can be resolved and your system returned to proper working order.
Ensure that no zones are unintentionally bypassed when arming your system. Zones cannot be
bypassed once the system is armed. Bypassed zones (except for 24-hr zones) are automatically
cancelled each time the system is disarmed and must be bypassed again, if required, before
the next arming.
With the system disarmed:
1. Press to enter the function menu. The keypad will display the
2. Press or .
3. If your system is programmed to require access codes the screen
4. Scroll to the desired zone number using the keys, then
Activating All Bypassed Zones
To remove bypass (all zones):
1. Press , then your access code or present your prox tag if required.
2. Press .
3. To exit bypassing mode and return to the Ready state, press .
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press , then your access code or present your prox tag if required.
2. Press .
3. To exit bypassing mode and return to the Ready state, press .
Bypass Group
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of
zones on a regular basis, you can program them into a Bypass Group, so that you do not have to
bypass each zone individually. Note that only one Bypass Group can be programmed at a time.
To program a Bypass Group:
1. Press , then your access code or present your prox tag if required.
2. Enter the 2-digit numbers (01-34) of the zones to be included in the Bypass Group or use the
3. To save the selected zone into the group, press .
4. To exit bypassing mode and return to the Ready state, press .
NOTE: If an access code is required to enter bypassing, only the master code and codes with
Supervisory enabled can set the Bypass Group.
To select a Bypass Group when arming the system:
1. Press , then your access code or present your prox tag (if necessary).
2. Press . The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press .
screen on the right.
on the right will be displayed. Enter your 4-digit access code.
press to select the zone or directly enter the 2-digit number
of the zone you wish to bypass (e.g., 0 5 for zone 5).
buttons to find the zone to be included in the Bypass Group, then press to
select the zone.
Press (*) for <>
Enter Your
Access Code
Scroll to <>
Bypass Zones
5
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.