NEO – Zone Attributes
NEO HS2016 / HS2032 / HS2064 / HS20128 v1.3
Zone Attributes
The following information describes the zone attribute programming options. To modify the zone
attributes, first enter into Section [002] and then enter into the SubSection {001 – 128} (the 3
digit zone number.) After modifying the zone attributes as needed, press the # key and enter the
next zone number (SubSection) if additional zones need to be modified; or the # key a second
time to your solid red light.
Section [002] – Zone Attributes
Zone attributes are used to customize the operation of the independent zones. When a zone
type (Section [001]) is programmed, the default zone attribute is automatically assigned. See
the Reference Manual for the default attribute settings for each zone type.
Note: These attributes allow you to override the default settings. DO NOT change any fire zone
attributes from their default settings.
SubSection {001 – 128}
Note: The attributes listed below can be enabled and disabled for each zone independently.
01 – Bell Audible
ON: An alarm activates the siren.
OFF: Silent alarm.
02 – Bell Steady
ON: Siren output is steady when in alarm.
OFF: Siren output pulses when in alarm.
03 – Door Chime
ON: The keypad chimes when the zone is open and/or when the zone is secured.
OFF: The zone does not chime.
04 – Bypass Enabled
ON: The zone can be manually bypassed.
OFF: The zone cannot be bypassed.
Note: Bypass shall not be enabled for fire zones.
05 – Force Arm
ON: The system can be armed with the zone open. The zone is temporarily bypassed,
and when secured, is monitored by the system.
OFF: The system cannot be armed if the zone is open.
1 of 2
![](/html/a5/a513/a51387661b19399bfeb6c20c7acaf3710f7698658b004dc38bdf7fa30b1c0072/bg2.png)
To access Attribute 09 – 14; Press the ‘9’ key while in the Toggle section.
NEO – Zone Attributes
06 – Swinger Shut Down
ON: When the zone goes into alarm for the number of times programmed in the Swinger
Shutdown Counter (See Section [377]{001} – “Swinger Shutdown"), it shuts down
with no further transmissions sent to the monitoring station. The siren follows
swinger shutdown if programmed.
OFF: Swinger shutdown is disabled. All alarms are transmitted.
07 – Transmission Delay
ON: Reporting of zone alarms is delayed for the programmed time for Communication
Delays (See Section [377]{002} – “Communication Delays".) If a valid access code
is entered within this time, no alarm signal is communicated.
OFF: When an alarm occurs, the reporting code is transmitted immediately.
08 – Burglary Verification
ON: Enabled for cross zoning/police code. Zone alarms are not communicated until a
burglary verified event occurs.
OFF: Not enabled for cross zoning/police code.
09 – Normally Closed (NC)
ON: The zone requires a normally closed loop.
OFF: The zone follows programming in Section [013] Option 1 & 2.
(See Note3 below.)
10 – Single End of Line (SEOL) Resistors
ON: The zone requires a single end-of-line resistor (5.6kΩ).
OFF: The zone follows programming in Section [013] Option 1 & 2.
(See Note3 below.)
11 – Double End of Line (DEOL)
ON: The zone requires two end-of-line resistors (5.6kΩ).
OFF: The zone follows programming in Section [013] Option 1 & 2.
(See Note3 below.)
Note3: If more than one option is enabled for Options 09, 10, and 11 the lowest attribute number
takes precedence. If Options 09 and 10 are both enabled the zone follows the normally closed
loop configuration. DO NOT CHANGE UNLESS YOU ARE OVERRIDING SECTION [013].
12 – Fast Loop/Normal Loop Response
ON: Follows a fast loop response of 50ms.
OFF: Follows a normal loop response as programmed in the Zone Loop Response Time
Section [005]{000}. (Default is 250ms.)
13 – 2-Way Audio Attribute
ON: Panel is able to initiate a 2 way audio session.
OFF: Only the microphone turns on, initiating a Listen-in only session. The speaker
remains off.
14 – Hold Up Verification
ON: An alarm from zones of this type can contribute to a verified holdup alarm. Use this
attribute with Panic and Holdup zones.
OFF: An alarm from zones of this type does not contribute to a verified hold up alarm. The
zone does not cause the holdup verification timer to start counting down, or generate
a verified hold up if the alarm is detected while the timer is running.
2 of 2