DSC GS2065, TL265GS, Alexor GS2065, Alexor TL265GS Technical Training Manual

Overview:
The GS2065 provides primary or backup GSM/GPRS communication for the PC9155 2-way wireless security suite
Specifications:
Dimensions : 3.937"x5.875"x0.625" (100mmx150mmx15mm) Weight : 68 g Input Voltage : 10 to 13.8 V (from the PC-Link header) Current Draw : 100 mA at 12V (400 mA during the GSM transmission) Operating Environment : 40 to 104 F (5 to 40 C)
Features:
Back up and primary GSM/GPRS alarm communication Panel remote uploading/downloading support via GSM/GPRS Supervision heartbeats via GSM/GPRS 128-bit AES encryption over GSM/GPRS Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz
Compatible Receivers:
Sur-Gard System I Receiver: version 1.10 and higher
Sur-Gard System II Receiver: version 2.00 and higher
Sur-Gard SG-DRL3-IP: version 2.20 and higher (for Sur-Gard System III Receiver)
Overview:
The TL265GS is an Internet and GSM/GPRS Dual-Path alarm communicator for the PC9155 2-way wireless security suite
Specifications:
Dimensions : 3.937"x5.875"x0.75" (100mmx150mmx18mm) Weight : 78 g Input Voltage : 10 to 13.8 V (from the PC-Link header) Current Draw : 100 mA at 12V (400 mA during the GSM transmission) Operating Environment : 40 to 104 F (5 to 40 C)
Features:
Fully redundant Internet and GSM/GPRS dual-path alarm communication Integrated call routing Panel remote uploading/downloading support via GSM/GPRS and Internet Supervision heartbeats via GSM/GPRS and Internet 128-bit AES encryption via GSM/GPRS and Internet Full event reporting SIA format PC-Link connection SIM card included Signal strength and trouble display Activating and initializing through Connect 24 Quad-Band: 850 MHz, 1900 MHz, 900 MHz and 1800 MHz
Compatible Receivers:
Sur-Gard System I Receiver: version
1.10 and higher Sur-Gard System II Receiver: version
2.00 and higher Sur-Gard SG-DRL3-IP: version 2.20
and higher (for Sur-Gard System III Receiver)
BEFORE YOU BEGIN
Have the following ready before installation:
Control panel backup battery Battery connection harness Batteries for WT5500 2-way wireless keypad Screwdriver
Prior to installing a GS2065 and TL265GS, contact your monitoring station to determine if it is a master reseller or visit www.connect24.com and become an authorized dealer. In both instances, you will acquire a Profile Number, Installer ID Number and an Installer Password.
PLEASE NOTE: You need to activate the SIM card and initialize the communicator 24 HOURS BEFORE
INSTALLATION (Steps 1).
Summary of Installation Steps
Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)
Step 2 – Install and wire the communicator to the control panel (on-site)
Step 3 – Load the programming and test for best signal strength location
Step 4 – Program communication options on the control panel via keypad
Step 5 – Test communicator
Step 1 – Initialize an account via Connect 24 Website (www.connect24.com)
Login to Connect 24 website by using Installer ID and Password and initialize an account
Select Profile Number Select Product Module Enter SIM card number Enter DNIS number (if necessary) Enter Account Code Select Supervisory Type (if necessary) Enable DHCP (if necessary) Enter IP Address (TL260GS/TL265GS only) Enter Subnet Mask Address (TL260GS/TL265GS only) Enter Gateway Address (TL260GS/TL265GS only) Select Rate Plan Confirm information and submit activation application
Step 1 – 1
Select Profile Number
Select Profile
Step 1 – 2
Select Product Module
Select Module Number
Loading...
+ 14 hidden pages