Draper 220V User Manual

Page 1
Installation/Operating Instructions
220V Signature/Series E & V Electric Projection Screen
These Installation/Operating Instructions are available in the offi cial language of the country where you purchase the product. Please contact your distributor to request a copy. Vous pourriez demander les instructions d’installation et d’opération traduises dans la langue offi cielle du pays ou vous achetez le produit. Veuillez demander à votre distributeur. Die Gebrauchsanweisung für Installation und Konstruktion sind in der offi ziellen Sprache des Landes, indem Sie das Produkt gekauft haben, vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.
Caution
Read instructions through completely before proceeding. Follow instructions carefully. Installation con trary to instructions
invalidates warranty. Entire bottom of screen case should be unobstructed to permit proper operation of automatic trap door, and access to bottom panel for making electrical connections or servicing.
Screen should be installed level (using a carpenter’s level). Nothing should be fastened to screen dowel, viewing surface or
automatic trap door. Operating switch(es) is packed separately in screen carton. Do not discard with packing material. Screen operates on 220V, 50 Hz. current. NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any re spon si bil i ty on the part of Draper, Inc. for improper in stal la tion or faulty work man ship at the jobsite.
Hanging Screen
When locating viewing surface and checking clear ance for screen’s operation, remember that the surface is centered in case. Screen is normally recessed above ceiling and may be installed in a variety of ways. See details on back of this sheet. Regardless of mount ing method used, the following points apply: Screen should be positively and securely supported so that vibration or even abusive pulling on viewing surface will not weaken installation. Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen.
Entire bottom of case must be readily accessible after installation. The hinge that connects bottom panel and automatic trap door of screen
must be permitted to operate freely. Front and back of case must be straight—not forced to warp or bow. Hinges must be free from mastic or paint buildup, and doors must be unobstructed by ceiling tiles.
Do not use screen case to support adjacent sections of ceiling. If trim pieces must be attached to case, do not permit screws to protrude
more than 6.35 mm through 3.2 mm wall of case. Do not attach trim pieces with nails. If case is painted, slots on bottom of case should be shielded to protect viewing surface from paint splatters or overspray. Do not seal unit in ceiling until electrical connections have been made and screen has been operated successfully.
Electrical Connections
Screen operates on 220V., 50 Hz., 1 ph. current. Junction box is located just above the access plate at left end of screen. Access plate is held closed with fl at head screws and may be opened with a Phillips screwdriver. (Au to mat ic trap door does not need to be opened to make fi eld con nec tions.) Re mov al of access plate exposes ter mi nal strip, per wiring di a gram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed.
Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in ac cor dance with attached wiring diagram, and wiring should comply with National and local electrical codes. All operating switches should be “OFF” before power is
connected.
CAUTION—Important Instructions—Signature/Series V—The shipping
sup port brack ets must be removed from each end of dowel during initial op­eration before screen is operated in UP direction. After screen is installed, run
viewing surface DOWN to access screws that hold brackets to dowel. Loosen hex head screw, remove bracket and retighten screw at each end of dowel. Signature/Series E—The protective paper wrapping around the viewing sur­face must be removed before the screen is op er at ed in down direction. Cycle view ing sur face down and up several times to con fi rm sat is fac to ry op er a tion. If viewing surface or trap door do not operate properly, turn power off and free trap door and/or check electrical con nec tions. 220V Single Sta tion Con trol—3-position UP-OFF-DOWN switch per mits op er a tion to be stopped at any point. Factory set limit switches au to mat i cal ly stop screen when fully down or fully up. 220V Multiple Station Control (Not CE Approved)Switches are similar in ap pear ance to Single Station Control. Screen stops when switch is re leased and may be re start ed in either direction. Factory set limit switches stop screen au to mat i cal ly when fully up or fully down. 24V Control—Three-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory set limit switch es au to mat i cal ly stop screen when fully up or fully down. Wireless controls—whether infrared or radio frequency—interface with low voltage control box. Key Operated Switching (Not CE Approved)Two kinds of key-operated switches are op tion al ly available with this unit. The key-operated power supply switch controls power to the screen and switches. When it is “off”, the switches will not operate screen. Key may be removed from the switch in “on” or “off” position. A three-position key switch permits the screen to be op er at ed directly by key. In this case, the screen’s operator must have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote.
Screen has been factory set and should not require further ad just ment. How­ever, if you wish to change the “up” and “down” stopping po si tions, proceed as follows:
CAUTION: Be sure all switches are in “off” position before adjusting limit switches. Always be pre pared to shut screen off man u al ly when new ad­ just ment is being tested. Screen may be se vere ly damaged if viewing surface is al lowed to run too far up or too far down.
Adjusting “Fully Up” Position—“Up” stopping position may be adjusted by turning the yellow llimit switch adjustment socket. The yellow socket is located on left end of screen roller and is ac ces si ble to a screw driv er/Allen wrench (4mm or face to retract further into the case. Turning it clock wise will cause the surface to stop further out of the case. One full revolution of the socket will alter the stopping position of the viewing surface by ap prox i mate ly 3.8 cm.
Adjusting “Fully Down” Position—“Down” stopping position may be ad just ed by turning the white limit switch adjustment socket. The white socket is lo cat ed on the left end of screen roller and is ac ces si ble to a small fl at screwdriver/Allen wrench (4mm or will allow the viewing surface to run farther down. Turning it clockwise will shorten the viewing surface, causing it to stop in a less extended position. At
no time should viewing surface be unrolled enough to expose any part of the screen roller.
Please note: See page 2 for information on adjusting Tab-Tensioning cables on Signature/Series V screens.
Operation
Adjustments
5
/32").Turning the socket coun ter clock wise will allow the viewing sur-
5
/32"). Turning the socket coun ter clock wise
Copyright © 2006 Draper Inc. Form Signature220V_Inst06 Printed in U.S.A.
If you encounter any dif fi cul ties installing or ser vic Signature screen, call your dealer or Draper, Inc. Spiceland, Indiana, U.S.A., (765) 987-7999, FAX (765) 987-1689, or e-mail to draper@draperinc.com.
ing your
Page 2
220V Signature/Series E & V by Draper
9
Page 2 of 2
38 mm Typ
A
Series A
E-small case 81 mm
54 mm
E-large case 114 mm V Varies
NOTE: Viewing surface shown is Series V with tab tensioning.
Series E, without tab tensioning, is also available.
Small Signature Case
Shown with
9.5 mm
threaded rod
(provided
by others).
Electrical connection to internal splice box
on left end of case. 22mm
knockout for 13 mm
conduit. J-Box cover located
under splice box.
248 cm
152 mm
Large Signature Case
Shown with
11 mm
threaded
rod (provided
by others).
280
Electrical connection to internal splice box
on left end of case. 22mm
knockout for 13 mm
conduit. J-Box cover located
under splice box.
SCREEN SIZE CASE SIZE
Total Drop < 396 cm or viewing width < 366 cm Small Total Drop > 396 cm or viewing width > 366 cm Large
See separate Serial Communication-RS232 Instruction sheet for enabling RS232 with the MC1.
Fuse
cm
Program LED
MC1
152 mm
Case length
232
cm
232
cm
MC1
Red-to Screen (directional) Black-to Screen (directional) Blue-Common Brown-Hot to 230V AC Green/Yellow-Ground
Low Voltage Wiring by others AC Wiring by electrician
RS232 Data FROM Control System RS232 Data TO Control System Signal Ground & Manual Switch Common Manual Switch Down Manual Switch Up
Eye Port for IR Eye. For RF Receiver or LED Wall Switch, a Splitter and a Power Supply is required. Plug RF Receiver or LED Wall Switch and Power Supply into splitter, then run cable from Splitter to MC1 Eye Port.
Viewing surface
Audience
Ceiling grid and tile
(by others)
Audience
Ceiling grid and tile
(by others)
STOP
STOP
230V, 50 Hz.
Control Switches 24v DC
Case Dimensions and Methods of Installation
Draper’s Tab-Tensioning System is factory-set, and under normal circumstances will not require fi eld adjustment. If, however, you notice wrinkles, waves, or
Ceiling grid
and tile
(by others)
other indications that the tensioning cables need to be adjusted, follow the procedure below.
Determine which side requires adjustment. Secure dowel with one hand.
Caution: Do not touch or bend surface.
Using Philips-head screwdriver, depress spring-loaded adjustment screw (see Fig. 1) and slowly turn clockwise to tighten tension, or counterclockwise to loosen tension. The screw adjusts in ¼ turn increments. Adjust only one increment (¼ turn). If problem is not corrected, leave screen in position for 24 hours to allow surface material to stretch into position. If problem still is not corrected, repeat steps 2 and 3.
Single Station Control
CE Approved
Dashed wiring by electrician
Terminal strip in junction box at left end of screen
Hot
Neutral
All-Pole Disconnect by Others
Tab-Tensioning Cable Adjustment
Dowel
Wiring Diagrams
Multiple Station Control
Terminal strip in junction box at left end of screen
Control switch
Neutral
L1
PE
230V, 50 Hz.
230V, 50 Hz.
Low Voltage & Wireless Control
Red-to screen (directional) Brown-to screen (directional) White-Common to screen, 110-120V AC Black-to 110-120V AC Yellow-to 110-120V AC Green-Ground
Dashed wiring by electrician Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED Switch For more than one of these, a splitter is required.
3 Button Wall Switch DOWN - Black COM - White UP - Red
Aux Port for connecting additional LVC-III modules (up to six total­connect from Aux to Eye).
Tensioning Cable
Figure 1
Not CE Approved
Terminal strip in junction box at left end of screen
Red
Black
Red
Black
Red
Black
Neutral
Hot
STOP
STOP
230V, 50 Hz. Control Switches 24v DC
Adjustment Screw
Cap off with wire nut & tape
Blue
Blue
Blue
Dashed wiring by electrician
Terminal strip in junction box at left end of screen
Hot
Neutral
All-Pole Disconnect by Others
www.draperinc.com
(765) 987-799