1255, rue Principale
Linière, Beauce, Québec, Canada G0M 1J0
Telephone : (418) 685-3431 Fax: (418) 685-3948
Canada : (800) 463-1636 U.S.: (800) 463-4273
E-Mail : doyon@doyon.qc.ca Internet: http://www.doyon.qc.ca
Your local distributor:
Printed in Canada Rev: 112009d
OVERALL DIMENSIONS
TLOIE & TLOIG
49 1/2” W X 72 1/4” D X 105 5/8” H
(1255 mm X 1835 mm X2683 mm)
TLOIIE & TLOIIG
60 3/4” W X 82 3/8” D X 105 1/2” H
(1543 mm X 2092 mm X 2680 mm)
OVEN INTERIOR DIMENSIONS (wall to wall)
TLOIE & TLOIG
37” W X 39” D X 75” H
(940 mm X 990 mm X 1905 mm)
TLOIIE & TLOIIG
48” W X 50” D X 75” H
(1220 mmX 1270 mm X 1905 mm)
ELECTRICAL SYSTEM
TLOIE 3 phases:
120/208V - 122A - 44kW - 4 wires - 60 Hz
120/240V - 105A - 44kW - 4 wires - 60 Hz
220/380V - 74A - 49kW - 4 wires - 50 Hz
480V - 52A - 44kW - 3 wires - 60 Hz
600V - 42A - 44kW - 3 wires - 60 Hz
TLOIIE 3 phases:
480V - 75A - 62kW - 3 wires - 60 Hz
600V - 60A - 62kW - 3 wires - 60 Hz
220/380V - 94A - 62kW - 4 wires - 50 Hz
TLOIG 3 phases:
120/208V - 8A - 3kW - 4 wires - 60 Hz
120/240V - 10A - 3kW - 4 wires - 60 Hz
220/380V - 4.1A - 2.7kW - 4 wires - 50 Hz
Gas Info : 200 000 BTUH (Propane or Natural)
TLOIIG 3 phases:
120/208V - 10A - 3.5kW - 4 wires - 60 Hz
120/240V - 10A - 3.5kW - 4 wires - 60 Hz
220/380V - 5.1A - 3.3kW - 4 wires - 50 Hz
Gas Info : 300 000 BTUH (Propane or Natural)
Recommended gas pressure:
Propane gas : 11” W.C.
Natural gas : 7” W.C.
Gas exhaust 6” (152 mm)
INSTALLATION
- Unit must be on a level floor. Not approved for installation on combustible
floor surfaces.
- Certified for zero clearance to combustible surface sides and back.
- Drain connection recommended (located in the back of the unit, close
to the floor)
- Draft hood included with all models
- Floor must be bolted
- Electrical, water and gas sytems located on top of the unit
Specifications and design subject to change without notice.