The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are
trademarks or registered trademarks of HDMI Licensing LLC in the United States and other
countries.
H2S.OM.001539.DRM Page 3 of 40 Version 1.4
Doremi Labs
WARNING
THIS DEVICE MUST BE GROUNDED
IMPORTANT
Power requirements for electrical equipment vary from area to area. Please ensure that the
H2S-30 meets the power requirements in the surrounding area. If in doubt, consult a qualified
electrician or a Doremi Labs dealer.
H2S-30 Power Ratings
•The H2S-30 should only be used with a Doremi approved power supply.
•Power Supply Specifications:
•AC Input: 100-240V~, 1.2A, 50-60Hz
•Output 12V DC, 3.0A (36W Max.)
•H2S-30 Power Requirements
•12V DC, .12A
H2S.OM.001539.DRM Page 4 of 40 Version 1.4
Doremi Labs
Protecting Yourself and the H2S-30
Never touch the AC plug with wet hands. Always disconnect the H2S-30 from the power supply
by pulling on the plug, not the cord. Allow only a Doremi Labs dealer or qualified professional
engineer to repair or re-assemble the H2S-30. Apart from voiding the warranty, unauthorized
engineers might touch live internal parts and receive a serious electric shock. Do not put, or
allow anyone to put any object, especially metal objects, into the H2S-30. Use only Doremi
approved power supply.
If water or any other liquid is spilled into or onto the H2S-30, disconnect the power and call a
Doremi dealer. The unit must be well ventilated and away from direct sunlight. To avoid damage
to internal circuitry, as well as the external finish, keep the H2S-30 away from direct sources of
heat (heater vents, stoves, radiators). Avoid using flammable aerosols near the H2S-30. They
can damage the surface area and may ignite. Do not use denatured alcohol, paint thinner, or
similar chemicals to clean the H2S-30. This can damage the unit.
Modification of this equipment is dangerous and can result in the functions of the H2S-30 being
impaired. Never attempt to modify the equipment in any way. In order to ensure optimum
performance of the H2S-30, select the setup location carefully and make sure the equipment is
used properly. Avoid setting up the H2S-30 in the following locations:
•In a humid or dusty environment.
•In a room with poor ventilation.
•On a surface which is not level.
•Inside a moving vehicle where it will be subject to vibration.
•In an extremely hot or cold environment.
H2S.OM.001539.DRM Page 5 of 40 Version 1.4
Doremi Labs
C A U T I O N
R I S K O F E L E C T R I C S H O C K
D O N O T O P E N
!
C A U T I O N : T O R E D U C E T H E R I S K O F E L E C T R I C S H O C K ,
D O N O T R E M O V E C O V E R ( O R B A C K ) .
N O U S E R - S E R V I C E A B L E P A R T S I N S I D E .
R E F E R S E R V I C I N G T O Q U A L I F I E D S E R V I C E P E R S O N N E L .
T h e l i g h t n i n g f l a s h w i t h t h e a r r o w h e a d s y m b o l s u p e r i m p o s e d
a c r o s s a g r a p h i c a l r e p r e s e n t a t i o n o f a p e r s o n , w i t h i n a n e q u i l a t e r a l
t r i a n g l e , i s i n t e n d e d t o a l e r t t h e u s e r t o t h e p r e s e n c e o f u n i n s u l a t e d
“ d a n g e r o u s v o l t a g e ” w i t h i n t h e p r o d u c t ’ s e n c l o s u r e ; t h a t m a y b e
o f s u f f i c i e n t m a g n i t u d e t o c o n s t i t u t e a r i s k o f e l e c t r i c s h o c k .
!
T h e e x c l a m a t i o n p o i n t w i t h i n a n e q u i l a t e r a l t r i a n g l e i s i n t e n d e d t o
a l e r t t h e u s e r t o t h e p r e s e n c e o f i m p o r t a n t o p e r a t i n g a n d
m a i n t e n a n c e ( s e r v i c i n g ) i n s t r u c t i o n s i n t h e l i t e r a t u r e
a c c o m p a n y i n g t h e a p p l i a n c e .
WAR NI NG! !
T o p r e v e n t f i r e o r s h o c k h a z a r d , d o n o t e x p o s e t h i s a p p l i a n c e t o r a i n o r m o i s t u r e
H2S.OM.001539.DRM Page 6 of 40 Version 1.4
Doremi Labs
1 Introduction
1.1 Purpose
This document provides guidance on how to use the H2S-30 HDMI® to SDI converter that
incorporates High-Definition Multimedia Interface technology, as well as the Doremi Universal
Interface Software (DUIS). It explains all features of the H2S as well as the infrared remote
control and how to upgrade the firmware.
1.2 Software Version
•DUIS software version 4.2.3
•H2S-30 Firmware version 1.6.0
1.3 Contact Information
If in need of help or assistance, please contact Doremi Labs Technical Services at
+ 1-818-562-1101 or email at proavsupport@doremilabs.com .
H2S.OM.001539.DRM Page 7 of 40 Version 1.4
Doremi Labs
2 H2S-30 Overview
2.1 H2S-30 Description
The H2S-30 is an HDMI to SDI format converter featuring HDMI and SDI connectors that
allow for any HDMI input to be converted to any supported SDI output format or scan rate. It
supports both SD and HD video and employs 12 bit bi-cubic interpolation to ensure the highest
quality picture. It also supports 3G SDI and can tackle many conversion tasks.
2.1.1 H2S-30 Top View
Figure 1: H2S-30 Top View
2.1.2 H2S-30 Front Panel
The H2S-30 front panel is illustrated below:
Headphone Jack
Power Switch
Figure 2: H2S-30 Front Panel View
H2S.OM.001539.DRM Page 8 of 40 Version 1.4
Doremi Labs
HDMI LED
Infrared Sensor
SYNC LED
Power LED
2.1.3 H2S-30 Rear Panel
The H2S-30 rear panel is illustrated below:
Power Connector
USB
HDMI
in
Figure 3: H2S-30 Rear Panel View
The rear panel has the following connectors:
ConnectorDescription
USBUSB connector
HDMI inHDMI input connector
SDI-A outSDI output connector – Link A
SDI-B outSDI output connector – Link B
SYNC inSync input connector
PowerPower supply connector
SYNC
in
SDI-B
out
SDI-A
out
H2S.OM.001539.DRM Page 9 of 40 Version 1.4
Doremi Labs
2.2 Supported Formats
The table below summarizes all supported inputs and outputs available on the H2S-30.
Supported Input(s)Supported Output(s)
HDMI: Supported input formats are
listed below:
640x480 = VGA
720x480i = 480i
720x480p = 480p
1440x480i = 480i
720x576i = 576i
720x576p = 576p
1440x576i = 576i
800x600 = SVGA
1280x720 = 720p
1024x768 = XGA
1280x768 = WXGA
1364x768 = WXGA
1366x768 = WXGA
1536x768 = 1536x768
1152x864 = XGA+
SD-SDI: NTSC, PAL (SMPTE 259M-C
4:3 or 16:9, SMPTE 259M-C 4:3 or 16:9)
HD-SDI: all HD formats (SMPTE 274,
SMPTE296, SMPTE372, SMPTE 424M
3G SDI).
Note: 3G SDI supported features include:
1080p at fps ≥ 47.95.
1280x960 = SXGA-
1280x1024 = SXGA
1364x1024 = 1364x1024
1400x1050 = SXGA+
1680x1050 = WSXGA+
1920x1080i = 1080i
1920x1080p = 1080p
2048x1080 = 2Kp
1600x1200 = UXGA
1920x1200 = WUXGA
H2S.OM.001539.DRM Page 10 of 40 Version 1.4
Doremi Labs
3 H2S OSD Menu System Overview
The H2S-30 is configured using the IR remote control to access the menu system through the
OSD (see Section 4). Or by using the Doremi Universal Interface Software (DUIS) - see Section
5.
3.1 Input Menu
The Input menu can be used to set up the input parameters.
Sub-MenuValueDescription
Interface
HDMI/DVI colorAuto
Default EDID720p 50
HDMI/DVI
Pattern
RGB
RGB ext
YCbCr 601
YCbCr 601 ext
YCbCr 709
YCbCr 709 ext
720p 60
1080i 25
1080i 30
1080p 50
1080p 60
WUXGA 50
WUXGA 60
Input interface setting.
Pattern produces 100% color
bar patterns with 8 channels of
audio. The odd channels being
at 1kHz and the even channels
at 2kHz.
HDMI/DVI input color setting.
Auto: Usually RGB.
Ext: designates extended color
range (full bandwidth) as
opposed to limiting the color
spectrum to comply with ITU
standards.
Default EDID setting.
When you feed a signal to the
HDMI input, the H2S-30 has to
report a native resolution over
EDID. This menu allows the
user to change the default
resolution of the H2S-30
between the available formats.
CAUTION: Disconnect the
HDMI/DVI source before
changing this setting.
H2S.OM.001539.DRM Page 11 of 40 Version 1.4
Doremi Labs
3.2 Output Menu
The Output menu can be used to set up the output parameters. See table below for more
information.
Sub-MenuValueDescription
Interface
SDI ColorAuto
SDI ResolutionNTSC
SDI
RGB
RGB ext
YCbCr 601
YCbCr 601 ext
YCbCr 709
YCbCr 709 ext
XYZ’
PAL
720p
1080i/sf
1080p
The output interface is set to
SDI by default. It is the only
output interface available.
Set the SDI output color mode
Auto: 601 (SD) 709 (HD), RGB
(2K)
Ext: designates extended color
range (full bandwidth) as
opposed to limiting the color
spectrum to comply with ITU
standards.
Note: XYZ Colorspace is nonlinear.
Set the SDI output pixel
resolution.
Match Input: In this mode, the
SDI output will have the same
resolution as the input source.
2Kp
2Kp Flat
Match Input
H2S.OM.001539.DRM Page 12 of 40 Version 1.4
Doremi Labs
Sub-MenuValueDescription
SDI Frequency23.98
24
25
29.97
30
47.95
48
50
59.94
60
Match Input
Match Input x2
SDI Force InterlOff
On
Ancillary outOff
Bypass SDI
Set the SDI output frame rate.
Match Input: In this mode, the
unit will set the SDI output
resolution to match the input
resolution – or to the closest
output resolution if the exact
input resolution is not available.
Match Input x2: Match input x2
will output twice the input frame
rate.
e.g. Input= 1080p 30; Output=
1080p 60
Force the SDI output to
interlaced (or Segmented
Frame)
Set the Ancillary data on the
SDI output.
- Off: No VANC on SDI output.
- Bypass SDI: Pass Ancillary
data from HDMI input to SDI
output.
Time CodeOff
Bypass SDI
Free wheel
Set the embedded (SDI output)
Time code mode.
Off: No embedded timecode on
SDI output.
Bypass SDI: Pass embedded
timecode from HDMI input to
SDI output.
Free wheel: Generate
embedded Time Code starting
at the moment this option is
enabled.
H2S.OM.001539.DRM Page 13 of 40 Version 1.4
Doremi Labs
3.2.1 Color Space
The ITU-R BT.709-5 (HD formats) and ITU-R BT.601-5 (SD formats) standards define the range
of color values in a digital signal to be:
•16 to 240 for 8bit coding
•64 to 960 for 10bit coding
The H2S-30 color space conversion supports these standards, but it also supports full range by
allowing the color values to be between:
•0 to 255 for 8bit coding
•0 to 1023 for 10bit coding
On the H2S-30, the full range modes are designated by the “ext” following the color space
conversion mode.
3.3 Image Menu
The Image menu can be used to set up the image parameters.
Sub-MenuValueDescription
Brightness0% to 100%Brightness value setting
Contrast0% to 100%Contrast value setting
ScalingAspect Ratio
Fill
Aspect Fit H
Aspect Fit V
One to One
De-interlacingOff
On
Motion
SD Ratio4:3 Digital
16:9 Digital
4:3 Analog
16:9 Analog
Scaling value setting
Aspect Ratio: Maintain input
aspect ratio.
Fill: Scale to fill the output
resolution.
Aspect Fit H (V): Scale
Horizontally (Vertically) to fill the
output resolution.
One to One: No Scaling.
Set the De-interlacing mode.
Motion: De-interlacing is based
on motion.
Define the source PAR for SD
formats.
For source PAR of 8:9 or 16:15
use 4:3 Digital or 16:9 Digital.
For source PAR of 10:11 or
59:54 use 4:3 Analog or 16:9
Analog.
H2S.OM.001539.DRM Page 14 of 40 Version 1.4
Doremi Labs
Sub-MenuValueDescription
Input LUTUser Defined
0.1 to 4.0
Output LUTUser Defined
0.1 to 4.0
Set the input Gamma
correction.
For User Defined Input LUT use
the DUIS software (see Section
5.4.3)
Set the output Gamma
correction.
For User Defined Output LUT
use the DUIS software (see
Section 5.4.3)
H2S.OM.001539.DRM Page 15 of 40 Version 1.4
Doremi Labs
3.4 Sync Menu
The Sync menu can be used to set up the sync parameters.
Sub-MenuValueDescription
Input
H offsetX pixelsHorizontal Sync offset in pixels
V offsetX linesVertical Sync offset in lines
HDMI/DVI
Extern
Extern: Sync is derived from
the Sync Input connector.
H2S.OM.001539.DRM Page 16 of 40 Version 1.4
Doremi Labs
3.5 Audio Menu
The Audio menu can be used to set up the audio parameters.
Sub-MenuValueDescription
Input
DelayX framesAudio delay setting from -1 to
Level-18, -12, -6, 0, +6, +12,
Swap Channels 3
and 4
SDI Out GroupsAuto
DVI/HDMI
+18 dB
Off
On
1
1+2
1+2+3
1+2+3+4
Off
Audio input is set to DVI/HDMI
by default. It is the only input
interface available.
+2 frames.
Audio Output level setting.
When selected input channel 3
will be output on channel 4 and
input channel 4 will be output
on channel 3.
Set the embedded SDI active
audio groups.
Auto: All audio inputs will be
present on the SDI output.
Each group has 4 audio
channels, when 1+2+3+4 is
selected, all 16 audio channels
will be present.
Off: No embedded audio on SDI
output.
3.5.1 Supported Audio Sample Rates
•HDMI Input: 48 kHz
•SDI Output: 48 kHz
Note: The H2S-30 does not support audio sample rate conversions. If using the Embedded SDI
Audio output, you must use 48 kHz audio on the HDMI input. Using unsupported audio sample
rates will result in degraded audio output.
H2S.OM.001539.DRM Page 17 of 40 Version 1.4
Doremi Labs
3.6 On Screen Display (OSD) Menu
The OSD menu can be used to set up the OSD parameters.
Sub-MenuValueDescription
OSD EnableYes
No
OSD timeoutX s (seconds)On Screen Display timeout in
OSD H PositionHorizontal Position BarOSD horizontal position
OSD V positionVertical Position BarOSD vertical position
OSD Status
The OSD Status
will show the burn-
in window
timecode, I/O
status and audio
levels when the
OSD is not active.
Off
TC BIW
Input Status
Output Status
Enable or disable On Screen
Display.
seconds. Set to Infinite to keep
it always on.
Burn In Window and Status
display
Off: BIW and Status not
displayed
TC BIW: Timecode is shown in
a burn-in window on the H2S30 output
Input Status: In addition to the
timecode BIW, the H2S-30
output will display the Input
Status including Audio levels,
Closed Caption presence, Input
Format and CRC errors
(flashing red dot).
Output Status: In addition to the
timecode BIW, the H2S-30
output will display the Output
Status.
TC ColorWhite/Black
W/B Zoom
Black/White
B/W Zoom
H2S.OM.001539.DRM Page 18 of 40 Version 1.4
Doremi Labs
Burn In Window type setting.
3.7 System Menu
The System menu allows access to the system parameters.
Sub-MenuDescription
SaveSave current settings to flash.
Select to Save, when the “?” appears select again
to confirm
Firmware: x.yFirmware version
Serial: zzzzzzzSerial number
License: uuuuuuuuLicense number
Temp: vv CTemperature (in degree Celsius)
StandbyStandby mode: Puts the unit in Power Down
mode
Auto StandbyAuto Standby mode: Sets the idle time duration
before the unit goes in power down mode
automatically
IRInfra-Red. To avoid IR interference with multiple
H2S-30 units, assign each a different IR code
from 0x0 to 0xF (16 total) default is 0. Set the DIP
switch on the Doremi IR remote accordingly
The IR channel can also be set to OFF, which
disables the IR remote control completely
3.8 Status Menu
The Status menu can be used to view the Input and Output status.
Sub-MenuDescription
In:
Out:
Input and Output format status information
H2S.OM.001539.DRM Page 19 of 40 Version 1.4
Doremi Labs
4 Infrared Remote Controller
The Menu System can be accessed using the IR remote controller in conjunction with the OSD.
Pressing the Menu button will invoke the menu system. The Left arrow, Right arrow, Select and
Exit buttons can be used to navigate the OSD menu selections and set up the H2S-30.
4.1 Remote Controller Overview
“Up Arrow” Button
“Left Arrow” Button
“Menu” Button/Menu Field
SDI Output Fortmat Area
“Scaling” Button
“De-int Filter” Button
“Select” Button
“Right Arrow” Button
“Down Arrow”
Button
“Exit” Button
Input Source Setting Area
HDMI/DVI Output Format Area
“Save” Button
“Status OSD” Button
Figure 4: Infrared Remote Controller
•The remote controller is divided into four different areas:
•Input Source Setting
•Navigation or Menu System
•HDMI/DVI Output Format (unused with H2S-30)
•SDI Output Format
H2S.OM.001539.DRM Page 20 of 40 Version 1.4
Doremi Labs
4.2 Remote Controller Functions
Remote ControlFunction
Input source selectionSelect: DVI-D/HDMI, or Pattern.
Note: SDI and DVI-A buttons are unused
“IR lock” buttonUnused
“Reset” buttonUnused
“Menu” buttonInvoke the Menu System
“Exit” buttonBack one menu level
SDI Output format areaForce the SDI output to:
480i
576i
720p
1080i
1080p
InRes (SDI Resolution Match Input)
InFps (SDI Frequency Match Input)
More formats are available through the menu system
“Up Arrow” buttonUnused
“Down Arrow” buttonUnused
“Left Arrow” buttonNavigate OSD left
“Right Arrow” buttonNavigate OSD right
“Select” buttonOk/Select
Scaling Cycles through the image settings
De-Int FilterCycles through the available De-int Filter settings
Status OSDCycles through the OSD status options
SaveSaves the current settings to flash
H2S.OM.001539.DRM Page 21 of 40 Version 1.4
Doremi Labs
4.3 Input Source Setting
•To select the Input Format, press one of the buttons available in the Input Source field
(see Figure 5).
Figure 5: Input Format Setting
•The user has the choice between DVI-D/HDMI and Pattern. The Pattern button will
generate color bars with 8 channels of audio at different frequencies (see Figure 5).
Note: The SDI and DVI-A buttons are unused.
4.3.1 SDI Output Format
•To set the Output Format to a specific SDI format, press “OUT-SDI” on the IR controller.
•Then, press the Output format to set: 480i, 576i, 720p, 1080i, 1080p, InRes, InFPS,
(more formats are available through the menu system). See Figure 6 below for more
information.
Figure 6: Quick SDI Output Format Setting
H2S.OM.001539.DRM Page 22 of 40 Version 1.4
Doremi Labs
4.3.2 Setting the IR Channel
When using multiple H2S-30 units, you can avoid interference by pairing each unit to an
individual remote. Assign each H2S-30 a different IR code from 0x0 to 0xF (16 total), and set
the dip-switches on the Doremi IR remote accordingly.
•Using the OSD or the DUIS software, set the IR channel to the desired setting between
the hex values 0x0 and 0xF.
•Remove the battery cover on the rear of the IR remote and set the four dip-switches
below the battery bay to the corresponding value.
Note: The 4 dip-switches represent the binary values 1, 2, 4, 8 (from left to right).
•Example:
◦ If using IR channel 6, set the dip-switches 2 and 3 to the high position.
Location of
IR Dip-switches
Figure 7: IR Channel Dip-Switches
Figure 8: IR Channel Dip-Switches Close Up
H2S.OM.001539.DRM Page 23 of 40 Version 1.4
Doremi Labs
5 Doremi Universal Interface Software (DUIS)
5.1 DUIS Installation
To install the Doremi Universal Interface Software, follow the steps below:
•Plug the USB cable between the H2S-30 and an available USB port on a computer.
•If the "Found New Hardware Wizard" window appears click “Cancel.”
•Run the installation package by double-clicking on the file
“Doremi_Universal_Interface_Software-4.2.2.0.exe,” which can be downloaded from:
http://www.doremilabs.com/
•After the installation is over, the "Found New Hardware Wizard" will appear:
Note: For Windows 7 users, the "Found New Hardware Wizard" will not appear.
•Go through all the steps shown below:
•Select the “No, not this time” option and then click “Next >” (see Figure 9).
Figure 9: ”Found New Hardware Wizard” Window Step 1
•When asked for the type of software installation, choose the option “Install the software
automatically (recommended).” See Figure 10.
H2S.OM.001539.DRM Page 24 of 40 Version 1.4
Doremi Labs
Figure 10: ”Found New Hardware Wizard” Window Step 2
•When the driver installation is complete, click on the “Finish” button (see Figure 11).
Figure 11: ”Found New Hardware Wizard” Window Last Step
•Run the DUIS and verify that there is a proper connection.
•If the "Hardware Installation" warning window appears, click on the “Continue Anyway”
button (see Figure 12 & 13).
H2S.OM.001539.DRM Page 25 of 40 Version 1.4
Doremi Labs
Figure 12: Hardware Installation Warning Window
Figure 13: Hardware Installation Warning Window for Windows 7
H2S.OM.001539.DRM Page 26 of 40 Version 1.4
Doremi Labs
5.2 Doremi Universal Interface Software Overview
The Doremi Universal Interface Software can control one or more H2S-30 devices connected to
a workstation through USB.
•When starting the DUIS, the following window will appear:
Figure 14: H2S-30 Control Panel Window Input Tab
•The DUIS is composed of the following parts:
•The “Devices” field, located on the top of the window, can be used to select a connected
H2S-30 from the drop down menu. Click on the “Refresh” button to see if all the
connected H2S-30 units are visible (see Figure 14).
•The “Information” field located just below the “Devices” field provides information about
the input, output, current 'timecode," and the audio input level of the connected H2S-30
device (see Figure 14).
•The “Control” field located below the "Information" field has tabs that can be used to
view or modify various settings on the connected H2S-30 unit. These settings include
Input, Output, Image, Sync I/O, Audio, OSD, and System. These tabs are presented in
Section 5.4 (see Figure 14).
•The “Settings” field located on the left part of the screen allows the user to manage the
settings files. The “Settings” field is presented in Section 5.3 below.
H2S.OM.001539.DRM Page 27 of 40 Version 1.4
Doremi Labs
5.3 Settings Field
The Settings field can be used to manage the settings files.
•To save the current H2S-30 configuration settings into a file, enter a settings "filename"
into the “Settings” text box in the top left corner and then click on the “Save” button.
•The saved settings file will appear in the “Settings” field.
Settings
Text Box
Settings
Field
Load
Button
Save
Button
Delete
Button
Import
Button
Export
Button
Update
Button
Figure 15: H2S-30 Control Panel Window Settings Field
H2S.OM.001539.DRM Page 28 of 40 Version 1.4
Doremi Labs
•To export the settings file to a specified location, select it in the “Settings” field and click
on the “Export” button. The user will be asked to confirm where to export the file using a
standard “Save as” dialog box (see Figure 15).
•To import an existing settings file from a .ghx file into the “Settings” field, click on the
“Import” button. Browse the files to select the appropriate “settings file” to import (see
Figure 15).
•The imported file will appear in the “Settings” field on the left part of the window. To
apply the settings to the connected H2S-30 unit, select the file and click on the “Load”
button. The H2S-30 settings will be updated (see Figure 15).
•To delete a settings file present in the “Settings” field, select it and click on the “Delete”
button (see Figure 15).
•To update the “Settings” field to reflect the content of the “User Settings” folder of the
H2S-30 Control Panel application (folder where all the settings files are stored), click on
the “Update” button (see Figure 15).
Note: The "Load," "Save," "Delete," "Import," "Export," and "Update" buttons become enabled
when the user selects the file from the "Settings" field (see Figure 15).
H2S.OM.001539.DRM Page 29 of 40 Version 1.4
Doremi Labs
5.4 Tabs Description
5.4.1 Input Tab
The Input tab is illustrated in Figure 14 and Figure 15 above. All parameters are explained
earlier in this manual in Section 3.1.
5.4.2 Output Tab
The Output tab is illustrated below in Figure 16.
Figure 16: H2S-30 Control Panel Output Tab
All parameters are explained earlier in this manual in Section 3.2.
H2S.OM.001539.DRM Page 30 of 40 Version 1.4
Doremi Labs
5.4.3 Image Tab
The Image tab is illustrated below in Figure 17.
LUT User
Radio Button
Figure 17: H2S-30 Control Panel Image Tab
All parameters are explained earlier in this manual in Section 3.3.
•To define either an Input or Output Gamma Curve, click the corresponding “User” radio
button and then press the “Gamma Curves...” button.
•From the Gamma Correction pop-up window (see Figure 18), you can adjust the
Gamma Curves by “Formula” by adjusting the slider bars in the “Formula Editing” section
or by loading a file.
•To load a file, select the “File” radio button in the “Gamma Curves Source” section then
press the “All Colors LUT..” button and browse for the appropriate file.
Gamma Curves
Button
H2S.OM.001539.DRM Page 31 of 40 Version 1.4
Doremi Labs
Load File
Radio Button
Formula Editing
Section
Figure 18: Gamma Correction Pop-Up Window
H2S.OM.001539.DRM Page 32 of 40 Version 1.4
Doremi Labs
5.4.4 Sync I/O Tab
The Sync I/O tab is illustrated below in Figure 19.
Figure 19: H2S-30 Control Panel Sync I/O Tab
All parameters are explained earlier in this manual in Section 3.4.
H2S.OM.001539.DRM Page 33 of 40 Version 1.4
Doremi Labs
5.4.5 Audio Tab
The Audio tab is illustrated below in Figure 20.
Figure 20: H2S-30 Control Panel Audio Tab
All parameters are explained earlier in this manual in Section 3.5.
H2S.OM.001539.DRM Page 34 of 40 Version 1.4
Doremi Labs
5.4.6 OSD Tab
The OSD tab is illustrated below in Figure 21.
Figure 21: H2S-30 Control Panel OSD Tab
All parameters are explained earlier in this manual in Section 3.6.
H2S.OM.001539.DRM Page 35 of 40 Version 1.4
Doremi Labs
5.4.7 System Tab
The System tab is illustrated below in Figure 22.
Save Settings
Button
Firmware
Upgrade Button
Restore Factory
Defaults Button
Enter New License
Button
Display Logs
Button
Figure 22: H2S-30 Control Panel System Tab
The parameters are explained earlier in this manual in Section 3.7.
•In addition, the System tab can be used to perform the following functions:
•To save the current settings to flash, click on the “Save Settings” button (see Figure 22).
•To restore the factory default settings, click on the “Restore Factory Settings” button
(see Figure 22).
•To enter a new license number, click on the “Enter New License Number ...” button and
type the new license number in the pop-up window (see Figure 22).
•To perform a firmware upgrade, click on the “Firmware upgrade (Current: 1.6.0)” button
– note that this button provides the current firmware version installed on the connected
unit, after “Current:”. See Section 6.1 for detailed upgrade steps to follow (see Figure
22).
•To display the logs, click on the “Display Logs” button.
H2S.OM.001539.DRM Page 36 of 40 Version 1.4
Doremi Labs
•A window containing the logs will appear:
Figure 23: Log Window
•Select “Auto Update” from the Log Window to see all messages (see Figure 23).
H2S.OM.001539.DRM Page 37 of 40 Version 1.4
Doremi Labs
6 Firmware Update
The firmware can be updated through a USB using the DUIS. In case one of the files listed in
the procedures below is missing, please contact Doremi Labs (see Section 1.3).
Note: The H2S-30, S2H-30, and GHX-10 all use the same firmware version, which is included
with the DUIS software.
6.1 USB Update
The firmware can be updated through USB using the Doremi Universal Interface Software as
presented in Section 5.4.7.
•To perform an update via USB, follow the steps below:
•Connect the H2S-30 to the computer using the USB cable provided with the unit.
•Start the Doremi Universal Interface Software. See Section 5 for more information.
•Go to the “System” tab (see Section 5.4.7).
•Click on the “Firmware upgrade” button.
•Click the Browse button and select the firmware file (e.g., “ghx_1.6.0.bin”) and then click
the “Upgrade now” button (see Figure 24).
Figure 24: Firmware Update - Browse Window
•Once the update is completed, cycle the power of the H2S-30.
H2S.OM.001539.DRM Page 38 of 40 Version 1.4
Doremi Labs
7 Acronyms
TermDefinition
DUISDoremi Universal Interface Software
DVIDigital Visual Interface
HDMIHigh-Definition Multimedia Interface
HD-SDIHigh-Definition Serial Digital Interface
IRInfra Red
OSDOn Screen Display
PAR Pixel Aspect Ratio
SDISerial Digital Interface
USBUniversal Serial Bus
H2S.OM.001539.DRM Page 39 of 40 Version 1.4
Doremi Labs
8 Document Revision History
DateVersionDescription
02/10/20111.0First version.
03/02/20111.1New pictures added.
07/26/20121.2Logo and contact information updated.
02/13/20131.3Minor revisions made to entire document. Section 1
updated.
05/05/20141.4Minor editorial changes made.
H2S.OM.001539.DRM Page 40 of 40 Version 1.4
Doremi Labs
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.