Dometic FRESHJET FJ1100, FRESHJET FJ1700, FRESHJET FJ2200, FRESHJET FJ3200 Operating Manual

EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
AIR CONDITIONERS
FRESHJET
FJ1100, FJ1700, FJ2200, FJ3200
Air conditioning roof unit
Operating manual . . . . . . . . . . . . . . . . . . . . 16
Dachklimaanlage
Bedienungsanleitung . . . . . . . . . . . . . . . . .48
Climatiseur de toit
Notice d’utilisation . . . . . . . . . . . . . . . . . . . 81
Aire acondicionado de techo
Ar condicionado para tejadilho
Manual de instruções . . . . . . . . . . . . . . . . 150
Climatizzatore a tetto
Istruzioni per l’uso . . . . . . . . . . . . . . . . . . .186
Airconditioning voor dakinbouw
Gebruiksaanwijzing. . . . . . . . . . . . . . . . . .219
Klimaanlæg til tagmontering
Betjeningsvejledning . . . . . . . . . . . . . . . 253
Kattooilmastointilaitteisto
Käyttöohje . . . . . . . . . . . . . . . . . . . . . . . . .350
Накрышный кондиционер
Инструкция по эксплуатации . . . . . . . . . 382
Klimatyzator dachowy
Instrukcja obsługi . . . . . . . . . . . . . . . . . . . 417
Strešné klimatizačné zariadenie
Návod na obsluhu. . . . . . . . . . . . . . . . . . . 449
Střešní klimatizace
Návod k obsluze . . . . . . . . . . . . . . . . . . . . 483
Te t ők lí ma -b e r en de z é s
Használati utasítás. . . . . . . . . . . . . . . . . . . 515
Takmonterad klimatanläggning
Bruksanvisning. . . . . . . . . . . . . . . . . . . . . 285
Takmontert klimaanlegg
Bruksanvisning. . . . . . . . . . . . . . . . . . . . . .318
FreshJet
1
2
4
3
FreshJet 1100, 1700, 2200
FreshJet 3200
1
2
4
3
1
3
2
FreshJet
Chillout ADB
1
2
3
4
ADB
4
3
2
1
4
FreshJet
1
7
6
13
12
15
14
2
4
3
11
10
9
5
8
3
5
4
FreshJet
Chillout ADB
1
2
ADB
1
5
1
4
3
2
6
FreshJet
1
1
1
1
FreshJet 1100, 1700, 2200
FreshJet 3200
5
1
1
FreshJet 1100, 1700, 2200
6
FreshJet 3200
7
7
Chillout ADB (9105306662)
AB
1
2
FreshJet
3
ADB (9105306664)
AB
3
1
2
8
FreshJet
8
FreshJet 1100, 1700, 2200 + Chillout ADB (9105306662)
787
254 533
225
==
535
FreshJet 1100, 1700, 2200 + ADB (9105306664)
787
254 533
562
25 – 60
==
480
562
47
257.5 297.5
45
555
225
= =
25 – 60
470
9
9
FreshJet
FreshJet 3200 + Chillout ADB (9105306662)
980
248
==
FreshJet 3200 +
ADB (9105306664)
980
248
650
703277
25 – 60
===
480535
650
703277
25 – 60
45
257.5 297.5
555
===
470
10
FreshJet
0
FreshJet 1100
11
FreshJet 1700
a
FreshJet
12
FreshJet
FreshJet 2200
b
13
FreshJet 3200
c
FreshJet
14
FreshJet
d
Chillout ADB
(9105306662)
e
ADB
(9105306664)
15
EN
FreshJet
Please read this instruction manual carefully before first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it.
Table of contents
1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
2.1 General safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
2.2 Operating the device safely . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3 Target group for this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
4 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5Optional extras . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
6 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7 Technical description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.2 Control panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.4 Air conditioning modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7.5 Additional functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8 Before initial use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
9 Operating the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.1 Basic notes on operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.2 Using the remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
9.3 Hint for improved use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
9.4 Switching the roof air conditioner on and off. . . . . . . . . . . . . . . . . . 32
9.5 Selecting the air conditioning mode . . . . . . . . . . . . . . . . . . . . . . . . 33
9.6 Selecting the blower setting manually . . . . . . . . . . . . . . . . . . . . . . . 33
9.7 Setting the temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.8 Adjusting the air nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
9.9 Setting the timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
9.10 Activating the sleep function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
9.11 Activating the “I feel” function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
9.12 Operating the lights (depending on the models) . . . . . . . . . . . . . . 38
9.13 Replacing the remote control batteries . . . . . . . . . . . . . . . . . . . . . . 39
16
EN
FreshJet Explanation of symbols
9.14 Setting the time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
9.15 Setting the winter mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
10 Cleaning the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
11 Maintenance of the roof air conditioner . . . . . . . . . . . . . . . . . . . . . . . .41
12 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
13 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
14 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
15 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
1 Explanation of symbols
WARNING!
!
Safety instruction: Failure to observe this instruction can cause fatal or serious injury.
!
A
I
CAUTION! Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the function of the product.
NOTE
Supplementary information for operating the product.
17
EN
Safety instructions FreshJet
2 Safety instructions
The manufacturer accepts no liability for damage in the following cases:
Damage to the product resulting from mechanical influences and excess voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
In particular, the manufacturer will not be liable for any consequential damage, espe­cially consequential damage caused by failure of the roof air conditioner.
Note the following basic safety information when using electrical devices to protect against:
Electric shock
Fire hazards
Injury
2.1 General safety
WARNING!
!
Electrical devices are not toys.
Keep electrical appliances out of reach of children or infirm persons. Do not let them use the appliances without supervision.
Persons whose physical, sensory or mental capabilities or whose lack of experience and knowledge prevent them from using the device safely should not use it without supervision or instruction by a respon­sible person.
Only use the device as intended.
Do not make any alterations or conversions to the device.
Installation, maintenance and repairs of the roof air conditioner may
only be carried out by qualified personnel who are familiar with the risks involved when handling refrigerant and air conditioning systems as well as the relevant regulations. Inadequate repairs may cause seri­ous hazards. For repair service, please contact the service centre in your country (addresses on the back page).
Do not use the roof air conditioner near flammable fluids or in closed rooms.
Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 50 cm must be kept.
18
EN
FreshJet Target group for this manual
Do not reach into air outlets or insert any foreign objects in the roof air conditioner.
Do not undo the upper cover of the roof air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
NOTICE!
A
2.2 Operating the device safely
Never drive through automatic car washes when the roof air condi­tioner is mounted.
Please ask your vehicle manufacturer if a technical inspection is required after fitting an air conditioner and whether the height entered in your vehicle documents needs to be altered: – FreshJet 1100, 1700, 2200: increased height 225 mm – FreshJet 3200: increased height 248 mm
If faults occur in the roof air conditioner's refrigerant circuit, the roof air conditioner must be checked by a specialist company and properly repaired. The refrigerant must never be released into the air.
WARNING!
Always disconnect the power supply when working on the device.
!
NOTICE!
A
The roof air conditioner is not suitable for use in agricultural or con-
struction vehicles.
Operate the device only if you are certain that the housing and the cables are undamaged.
3 Target group for this manual
This operating manual is for the user of the roof air conditioner.
19
EN
Scope of delivery FreshJet
4Scope of delivery
FreshJet 1100
Designation Reference No.
Dometic FreshJet 1100 roof air conditioner 9105306654
9105306655
Installation manual
Operating manual
FreshJet 1700
Designation Reference No.
Dometic FreshJet 1700 roof air conditioner with heating 9105306656
9105306658
Installation manual
Operating manual
FreshJet 2200
Designation Reference No.
Dometic FreshJet 2200 roof air conditioner with heating and soft start
with heating without soft start without heating and without soft start
Installation manual
Operating manual
9105306511 9105306515 9105306512 9105306513
20
EN
FreshJet Optional extras
FreshJet 3200
Designation Reference No.
Dometic FreshJet 3200 roof air conditioner with heat pump and soft start 9105306660
9105306659
Installation manual
Operating manual
Air outlet unit
Designation Reference No.
Chillout ADB 9105306662
ADB 9105306664
5Optional extras
Available as an option (not included in scope of delivery):
Designation Reference No.
DC extension kit DC-Kit1 (FJ1100 only) 9100300003
DC extension kit DC-Kit2 (FreshJet 1100, 1700, 2200 only)
DC extension kit DC-Kit3 (FreshJet 1100, 1700, 2200 only)
DC extension kit DC-Kit4 (FreshJet 1100, 1700, 2200, 3200)
DC extension kit DC-Kit5 (FreshJet 1100, 1700, 2200 only)
DC extension kit DC-Kit6 (FreshJet 1100, 1700, 2200, 3200)
9100300001
9100300002
9100300044
9100300073
9100300074
NOTE
I
The DC extension kit (accessory) allows the Dometic FreshJet roof air conditioner to be used while in motion.
21
EN
Intended use FreshJet
6 Intended use
The Dometic FreshJet roof air conditioner is designed for use in motorcaravans, caravans and other vehicles with habitation compartments only. It is not suitable for houses and apartments.
The roof air conditioner is not suitable for installation in construction machines, agri­cultural machines or similar equipment. It will not work properly if exposed to strong vibrations.
The function of the roof air conditioner is guaranteed for temperatures between 0 °C and 52 °C.
7 Technical description
The roof air conditioner supplies the interior with cool dehumidified air without dust and dirt.
Dimmable LED lamps integrated in the air outlet unit provide pleasant lighting (LED lights are available only on specific model).
The roof air conditioner is operated with the remote control.
NOTE
I
The roof air conditioner is protected against over-voltage. When the supply voltage is above 265 V, the roof air conditioner stops working. It resumes normal service when the supply voltage is within the allowed range.
The roof air conditioner can lower the temperature within the vehicle to a certain level. The temperature depends on the type of vehicle, the ambient temperature and the cooling capacity of your roof air conditioner. Below an outer temperature of 16 °C the roof air conditioner doesn’t cool anymore. In this case only use the air conditioning mode
“Circulating air” ( ).
22
EN
FreshJet Technical description
7.1 C o m p o n en t s
The refrigerant circuit of the roof air conditioner consists of the following main components (fig. 1, page 3):
Compressor (1) The compressor draws in the refrigerant used and compresses it. This raises the pressure and therefore the temperature of the refrigerant.
Condenser (2) The built-in liquefier works like a cooler or heat exchanger. The air flowing past absorbs the heat and the hot refrigerant gas cools down and becomes liquid.
Evaporator (3) The evaporators cool down and dehumidify the air flowing past them. The refrigerant absorbs the heat and vaporises.
Blower (4)
A blower distributes the cooled air within the vehicle through an air outlet unit.
Overview of all parts:
FreshJet 1100: fig. 0, page 11
FreshJet 1700: fig. a, page 12
FreshJet 2200 (available for models with heating and soft start): fig. b, page 13
FreshJet 3200: fig. c, page 14
Air outlet unit Chillout ADB: fig. d, page 15
Air outlet unit ADB: fig. e, page 15
23
EN
Technical description FreshJet
7.2 Control panel
The control panel is at the air outlet unit of the roof air conditioner (fig. 2, page 4). It contains the following control and display elements:
No. Explanation
1 Status LED
No light: The roof air conditioner is switched off.
Orange light: The roof air conditioner is in stand-by mode.
Green light: The roof air conditioner is switched on.
Flashing green light
Flashing green/orange: The roof air conditioner is in winter mode.
Red light: Only if the system is connected to 12 Vg: the supply
Flashing red: Over-voltage
Slowly flashing red light:
Quickly flashing red light:
2
Button
For models with heat pump only
The roof air conditioning is preparing for heat mode or defrost is active.
voltage of 230 Vw is not available.
The roof air conditioner resumes normal service when the supply voltage is within the allowed range.
Malfunction in interior temperature sensor E1
Malfunction in exterior temperature sensor E2
Switches the roof air conditioner on, off or to stand­by mode
Pressing the button longer engages the automatic mode.
3
Button
4 Infrared receiver for the remote control
24
Switches the light on or off or dims it. Only active when the roof air conditioner is switched
on or on stand-by.
EN
FreshJet Technical description
7.3 Remote control
All settings of the device (e. g. temperature settings, timer programming) are transmitted to the roof air conditioner by remote control.
The following control and display elements are available on the remote control (fig. 3, page 5) :
No. Explanation
1 Digital display:
Displays the following:
Time
Selected room temperature (target value) in °C or °F
Actual room temperature
Air conditioning mode
Blower level
Symbols for active additional functions
Battery status
2
3
4 MODE button:
5
6
7
button:
Switches the air conditioner and remote control on or to stand-by mode
button:
Selects the blower setting
Selects the air conditioning mode
button:
Activates the sleep function. The sleep function automatically modifies the target value to provide a pleasant sleeping temperature.
button:
Press once:
Press again:
button:
Activates the “I feel” function. Every 10 minutes, the “I feel” function adjusts the target temperature to the temperature measured by the remote control.
Displays the current interior temperature (symbol is displayed).
Displays the set temperature.
8 °C/°F button:
Switches between temperature units Celsius (°C) and Fahrenheit (°F)
9
button:
Sets the timer and the clock
25
EN
Technical description FreshJet
No. Explanation
10 SET button:
Confirms and saves settings
11
12 + button:
13 – button:
14
15
button:
Switches the light of the air conditioner on or off and activates the dimming function.
The button remains functional even when the remote control is switched off.
Increases the value
Reduces the value
Symbol (batteries empty) Is displayed when the batteries in the remote control are empty. If this happens,
replace the batteries, see chapter “Replacing the remote control batteries” on page 39.
Symbol (transmitting values) Is displayed briefly when the remote control is transmitting values to the air
conditioner.
26
EN
FreshJet Technical description
7.4 Air conditioning modes
The roof air conditioner has the following air conditioning modes:
Air conditioning mode
Automatic You specify the temperature, and the air conditioner
Cooling You specify the temperature and blower settings, and
Heating Available for models with heating only
Circulating air You specify the blower level, and the air conditioner
Dehumidification You specify the temperature, and the air conditioner
Display
message
Explanation
brings the interior to this temperature by heating (available for models with heating only) or cooling and by controlling the necessary blower output.
The button is deactivated in this mode.
the air conditioner cools the interior to this tempera­ture.
You specify the temperature and blower settings, and the air conditioner heats the interior to this tempera­ture.
blows air into the interior
cools the interior to this temperature and controls the necessary blower output and dehumidifies the interior (Circulating air mode).
.
The button is deactivated in this mode.
27
EN
Technical description FreshJet
7.5 Additional functions
The roof air conditioner has the following additional functions:
Additional function
Timer The air conditioner is switched on at the specified
Sleep The set temperature is modified by 1 °C after one hour
I feel The remote control measures the room temperature
Winter mode The winter mode avoids the icing inside the vehicle
Display
message
Explanation
time.
The air conditioner is switched off at the specified time.
The air conditioner is switched on and off at the specified times.
and by 2 °C after two hours to generate a pleasant temperature for sleeping.
and transmits this measurement to the air conditioner every 10 minutes. The air conditioner adapts the target value to this measurement.
during the winter storage. The winter mode is displayed by green/orange
flashing of the LED.
28
EN
FreshJet Before initial use
8 Before initial use
Inspection before starting up
Before you switch on the roof air conditioner, observe the following: Check whether the supply voltage and frequency correspond to the values
specified in the technical data, see page 44.
Ensure both the air intake opening and the air nozzles are free. All ventilation
grilles must always be kept free to ensure that the roof air conditioner is able to operate at maximum capacity.
CAUTION! Beware of injury
!
Setting the time
Do not insert your fingers or objects into the air nozzles or the intake grille.
Set the current time: see chapter “Setting the time” on page 39.
Set the remote control
Insert the batteries (see chapter “Replacing the remote control batteries” on
page 39).
The display shows all symbols for 5 seconds.Press simultaneously the The display shows the default model number.Press simultaneously + and button within 3 seconds to select the model
number: – FreshWell 3000: 02 –FreshJet: 07 –FreshLight: 11
The display shows all symbols for 5 seconds.The remote control is ready for operation.
button and the button during this 5 seconds.
29
EN
Operating the roof air conditioner FreshJet
9 Operating the roof air conditioner
9.1 Basic notes on operation
The roof air conditioner has four operating modes:
Operating mode Features
Off The roof air conditioner is switched off.
The remote control is inactive.
Stand-by The roof air conditioning is ready for operation and can be switched
on with the remote control. The lights are available.
On The roof air conditioner is conditioning the air in the interior.
Winter mode The roof air conditioner operates in a special heating mode that starts
at a temperature of 7 °C and stops when the temperature rises above 10 °C. The winter mode avoids icing inside the vehicle during the winter storage.
You can use the control panel to
switch the roof air conditioner on, off, to stand-by mode or to winter mode
switch the light on and off or dim it
You can use the remote control to
switch the roof air conditioner to and from stand-by mode.
switch the light on and off or dim it
make the settings
select additional functions
9.2 Using the remote control
There are two ways to control the roof air conditioner with the remote control:
You can transmit the values directly to the roof air conditioner when you set them
You can first specify all values on the remote control and then transmit them
collectively to the roof air conditioner
30
Loading...
+ 518 hidden pages