Please read this instruction manual carefully before installation and first
use, and store it in a safe place. If you pass on the product to another
person, hand over this instruction manual along with it.
Safety instruction: Failure to observe this instruction will cause fatal or
serious injury.
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair
the function of the product.
NOTE
Supplementary information for operating the product.
2Safety and installation instructions
Please observe the prescribed safety instructions and stipulations from the
vehicle manufacturer and service workshops.
The manufacturer accepts no liability for damage in the following cases:
• Faulty assembly or connection
• Damage to the product resulting from mechanical influences and excess voltage
• Alterations to the product without express permission from the manufacturer
• Use for purposes other than those described in the operating manual
Note the following basic safety information when using electrical devices to protect
against:
• Electric shock
• Fire hazards
• Injury
4
EN
FreshLightSafety and installation instructions
2.1Handling the device
WARNING!
!
!
• Installation and repair of the roof air conditioner may only be carried
out by qualified personnel who are familiar with the risks involved and
the relevant regulations. Inadequate repairs may cause serious
hazards. For repair service, please contact the service centre in your
country (addresses on the back page).
• Electrical devices are not toys.
Keep electrical devices out of reach of children or infirm persons. Do
not allow them to use electrical devices without supervision.
• Persons (including children) whose physical, sensory or mental
capabilities or whose lack of experience and knowledge prevent them
from using the device safely should not use it without supervision or
instruction by a responsible person.
• Do not undo the upper cover of the roof air conditioner in the event of
a fire. Use approved extinguishing agents instead. Do not use water to
extinguish fires.
CAUTION!
• The roof air conditioner must be installed securely so that it cannot fall
down.
• Only operate the roof air conditioner if you are certain that the housing
and the cables are not damaged.
• Do not use the roof air conditioner near flammable fluids or in closed
rooms.
• Make sure no combustible objects are stored or installed near the air
outlet. A distance of at least 50 cm must be kept.
• Do not reach into air outlets or insert any foreign objects in the device.
A
NOTICE!
• Only use the device as intended.
• The roof air conditioner is not suitable for use in agricultural or
construction vehicles.
• Do not make any alterations or conversions to the device.
• Never drive through automatic car washes when the roof air
conditioner is mounted.
• If faults occur in thes refrigerant circuit, the system must be checked by
a specialist company and repaired properly. The refrigerant must
never be released into the air.
5
EN
Target group for this instruction manualFreshLight
NOTE
I
2.2Handling electrical cables
!
!
A
• Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height entered
in the vehicle documents needs to be altered (increased height
210 mm).
WARNING!
• The electrical power supply may only be connected by a qualified
electrician (e.g. VDE 0100, Part 721 in Germany).
CAUTION!
• Attach and lay the cables so that they cannot be tripped over or
damaged.
NOTICE!
• Use cable ducts to lay cables through walls with sharp edges.
• Do not lay loose or bent cables next to electrically conductive
materials (metal).
• Do not pull on the cables.
3Target group for this instruction manual
The instructions in this manual are intended for qualified personnel at workshops
who are familiar with the guidelines and safety precautions to be applied.
6
EN
FreshLightScope of delivery
4Scope of delivery
No. in fig. 1NumberDescription
11Roof air conditioner
21Air outlet unit
33Fastening brackets
44Air filters
52Filter covers
64Seals
73Cable connectors
86Long fastening screws
96Short fastening screws
104Caps
111Remote control
5Accessories
Available as accessories (not included in the scope of delivery):
Part designationReference no.
DC extension kit DC-Kit29100300001
DC extension kit DC-Kit39100300002
DC extension kit DC-Kit59100300073
NOTE
I
The DC extension kit (accessory) allows the Dometic FreshLight roof air
conditioner to be used while in motion.
7
EN
Intended useFreshLight
6Intended use
The Dometic roof air conditioner FreshLight with integrated roof window can
condition the interior of campers and caravans with cool or warm air.
The roof air conditioner is not suitable for installation in construction machines, agricultural machines or similar equipment. It will not work properly if exposed to strong
vibrations.
Do not operate the roof air conditioner if the ambient temperature is above 52 °C.
Do not operate the roof air conditioner in the “Heating” air conditioning mode if the
room temperature is above 30 °C.
The heating mode is recommended at ambient temperatures of +2 °C and above.
NOTE
I
You can find additional information on roof air conditioners in the operating manual, such as the technical description or the controls.
7Labels
Labels are attached to the Dometic FreshLight roof air conditioners. These labels provide the user and fitter with information on specifications of the device.
8
EN
FreshLightInstallation
8Installation
CAUTION! Beware of injury
!
8.1Note on installation
Read this installation manual completely before installing the roof air conditioner.
The following tips and instructions must be observed while installing the roof air
conditioner:
D
!
The roof air conditioner may only be installed by qualified personnel
from a specialist company. The following information is intended for
technicians who are familiar with the guidelines and safety precautions
to be applied.
DANGER! Danger of electrocution
Disconnect all power supplies when working on the roof air conditioner.
CAUTION! Beware of injury
• Improper installation of the roof air conditioner can result in
irreparable damage to the device and put the safety of the user at
risk.
• The manufacturer assumes no liability for malfunctions and for the
safety of the roof air conditioner, especially for injury and/or damage
to property, if the roof air conditioner is not fitted in accordance with
these installation instructions.
• Observe the structural engineering of the vehicle and seal of all
openings made when installing the roof air conditioner.
• Check whether the roof of the vehicle is able to support the weight
of a person before climbing onto it. Ask the vehicle manufacturer
about the permissible roof loads.
9
EN
InstallationFreshLight
Note on transport
• Always have someone help you carry the roof air conditioner.
• Always lift the roof air conditioner to move it and never drag it over the roof
(fig. 2 A).
• Do not use the rear ventilation slots to lift it (fig. 2 B).
Note on installation location
• Before installing the roof air conditioner, check whether any vehicle components
could be damaged by the installation of the roof air conditioner (such as lamps,
cupboards, doors).
• Before installation, find out (by consulting the manufacturer of the vehicle)
whether the construction is designed for the static weight and the loads of the air
conditioner when the vehicle is in motion. The manufacturer of the roof air
conditioner assumes no liability whatsoever.
• The vehicle manufacturer may have already provided points where the opening
for the installation of the roof air conditioner can be made without any risk of
weakening the construction or cutting power cables.
• Select a flat and sufficiently level area at the centre of the vehicle roof between
two longitudinal sections for installation.
• The roof inclination of the installation surface may not exceed 10°.
• The roof air conditioner must be installed above 2 meters.
• Make sure no combustible objects are stored or installed near the air outlet.
A distance of at least 50 cm should be kept.
• Make sure that there are no objects within the vehicle which could obstruct the
attachment of the air outlet unit or the cooled air from flowing through the
swivelling air distribution nozzles.
• For safety reasons, note the location of existing wiring harnesses, wires and other
components within the installation area, in particular those which are not visible,
when installing the roof air conditioner (when drilling or screwing etc.).
10
EN
FreshLightInstallation
Note on electrical system
• Only a qualified electrician should connect the roof air conditioner to the
electrical power.
• Check that the voltage specification on the type plate is the same as that of the
power supply.
• If the lighting should also be switched on without a 230 V voltage supply, make
sure that there is a 12 Vg power supply line from the battery to the roof air
conditioner.
• Do not lay the 230 V mains cable and the 12/24 Vg cable together in the same
cable duct.
• Do not lay cables which are loose or bent next to electrically conductive material
(metal).
• Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
There are two ways of installing the air conditioner:
• Making a new opening (chapter “Making a new opening” on page 11). In this
case the opening must be reinforced by an appropriate frame.
• Using the existing roof hatch openings (ventilation hatch) in the vehicle (chapter
“Installing in a roof hatch opening already provided” on page 12).
8.2Making a new opening
See fig. 3
➤ Select an area at the centre on the roof between two longitudinal supports.
➤ Mark the position and size of the opening using the template included in the
packaging (A and B).
Alternatively, you could create two small openings (C).
See fig. 4
➤ Drill out the corners (A).
➤ Carefully cut out the opening on the roof using a keyhole saw or a similar tool (B).
Make sure no electrical power cables are damaged.
11
EN
InstallationFreshLight
See fig. 5
➤ Before installation, check whether the roof hole needs reinforcing.
➤ Remove the foam according to the width of your reinforcing rails (not in scope of
delivery) (A).
➤ Fit the reinforcing rails (B).
8.3Installing in a roof hatch opening already provided
NOTE
I
See fig. 6
➤ Remove all screws and fixtures of the existing roof hatch.
➤ Take out the roof hatch.
• Existing roof hatch openings in accordance with fig. 3 are suitable
for installing the roof air conditioner.
• Dispose of all waste material, glue, silicone and seals separately.
Observe the disposal guidelines.
• The manufacturer only assumes liability for parts included in the
scope of delivery. The validity of the warranty expires if the device is
installed together with third-party parts.
See fig. 7
➤ Remove the sealant around the opening using a scraper or similar tool.
See fig. 8
NOTICE!
A
➤ Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710).
Observe the sealant manufacturer’s instructions.
12
EN
FreshLightInstallation
8.4Laying the connecting cables
DANGER! Danger of electrocution
D
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see chapter “Technical data” on page 20).
➤ Select the cross-section of the cable corresponding to the length:
– Length < 7.5m: 1.5mm²
–Length > 7.5m: 2.5mm²
See fig. 9
➤ Make an opening on one side in order to feed through the electrical power
supply cable.
➤ Feed the 230 Vwcable through the opening into the vehicle interior.
If the lighting should be switched on without the use of a 230 Vwvoltage supply:
➤ Connect the cable with the positive terminal and the negative terminal of the
vehicle battery.
➤ Feed the 12 Vg cable through the opening into the vehicle interior.
Make sure there is no voltage at electrically operated components
before carrying out work on them!
8.5Installing the roof air conditioner
NOTICE! Risk of damage
A
See fig. 0
➤ Lift the roof air conditioner onto the roof of the vehicle.
➤ Position the roof air conditioner over the installation opening.
Observe the direction of travel.
Observe the structural strength of the roof of the vehicle. The roof of the
vehicle must be able to bear the weight of the roof air conditioner. The
roof must not be indented or deformed by the weight of the unit, even
over a longer period of time.
13
EN
InstallationFreshLight
Attaching the roof air conditioner
See fig. a
➤ Mount the fastening bracket with the two long fastening screws.
Start with the two fastening brackets on the outside.
See fig. b
NOTICE! Risk of damage
A
➤ Tighten the screws using a torque spanner and a fastening torque of 2.5 Nm.
Electrical connection
See fig. c
230 Vw cable
➤ Connect the roof air conditioner with the 230 Vw voltage supply.
Connect the cables (1) to a cable connector (2).
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
Tighten to the specified torque.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
➤ Connect the two cables of the remote light switch to the 2-pin plug (3).
➤ Insert the 2-pin plug (3) into socket on the circuit board.
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (4) from the socket on the main board.
➤ Connect the positive cable (5) with the plug.
➤ Connect the negative cable (6) with the plug.
14
EN
FreshLightInstallation
Connecting the air outlet unit with the roof air conditioner
See fig. d
➤ Remove the premounted filter covers (1).
➤ Remove the premounted air filter (2).
Fitting the seals
See fig. e
➤ Fit the seals (1).
Determine the thickness by referring to the following table:
Ceiling thicknessSeal thickness
25 mm20 mm
25–30mm25mm
30–35mm30mm
35–40mm35mm
40–45mm40mm
45–50mm45mm
50–55mm50mm
55–60mm55mm
Connecting the circuit board
See fig. f
➤ Insert the 12-pin plug (1) in the socket (4) on the circuit board of the air outlet unit.
➤ Insert the 2-pin plug (2) in the socket (3) on the circuit board.
15
EN
InstallationFreshLight
8.6Installing the air outlet unit
See fig. g
➤ Attach the air outlet unit to the (1) fastening brackets using the short fastening
screws.
➤ Insert the caps (2) in the holes over the fastening screws.
See fig. h
➤ Install the air filter in the specified sequence.
See fig. i
➤ Fit the filter covers.
➤ Enter the new vehicle height and weight in the vehicle documents.
16
EN
FreshLightTroubleshooting
9Troubleshooting
ProblemCauseRemedy
Roof air
conditioner
constantly switches
itself off.
No cooling
capacity
No heating
capacity
Icing sensor has tripped.Outer temperature is too low or all air
nozzles are closed.
The roof air conditioner is not set to
cooling.
The ambient temperature is above 52 °C. The roof air conditioner is only
The temperature set is higher than the
room temperature.
The ambient temperature is below 16 °C. The roof air conditioner is only
One of the temperature sensors is
defective.
The vaporiser fan is damaged.
The condenser fan is damaged.
The ambient temperature is above 30 °C. ➤ Only use the heating function of
The ambient temperature is below 2 °C. The heating function of the roof air
The temperature set is above 30°C.➤ Select a lower temperature.
The roof air conditioner is not set to
heating.
One of the temperature sensors is
defective.
➤ Set the roof air conditioner to
cooling.
designed for ambient temperatures of
up to 52 °C.
➤ Select a lower temperature.
designed for ambient temperatures
above 16 °C.
➤ Contact an authorised workshop.
the roof air conditioner at
temperatures below 30 °C.
conditioner is only designed for
ambient temperatures of up to 2 °C.
➤ Set the roof air conditioning to
heating.
➤ Contact an authorised workshop.
17
EN
DisposalFreshLight
ProblemCauseRemedy
Low air outputThe air intake section is clogged up.➤ Remove any leaves and other dirt
from the ventilation grilles of the
roof air conditioner.
The blower is defective.➤ Contact an authorised workshop.
Water enters the
vehicle
Roof air
conditioner does
not switch on.
Roof air
conditioner does
not switch off.
The condensation water drainage
openings are clogged up.
The seals are damaged.➤ Contact an authorised workshop.
No supply voltage (230 Vw) connected. ➤ Check the power supply.
The voltage is too low (under 200 V).
The voltage converter is defective.
One of the temperature sensors is
defective.
The electrical fuse of the power supply is
too low.
One of the temperature sensors is
defective.
The electrical fuse of the power supply is
too low.
➤ Clean the drainage openings for
condensation water.
➤ Contact an authorised workshop.
➤ Check the electrical fuse of the
power supply.
➤ Contact an authorised workshop.
➤ Check the electrical fuse of the
power supply.
10Disposal
Regulations for environmental safety and correct disposal
All organisations must apply a set of procedures to identify, evaluate and control the
influence that their activities (manufacturing, products, services, etc.) have on the
environment.
The procedures to be followed to identify significant environmental impact must take
the following factors into account:
• use of raw materials and natural resources
• atmospheric emissions
• discharge of liquids
• waste management and recycling
• contamination of the soil
18
EN
FreshLightDisposal
In order to minimise environmental impact, the manufacturer provides a series of
indications here below that should be taken into account by all those who, for whatever reason, interact with the appliance during its working life.
• All packing components must be disposed of (preferably recycled) in
compliance with statutory legislation in the country in which disposal takes place.
• All product components must be disposed of (preferably recycled) in compli-
ance with statutory legislation in the country in which disposal takes place.
• For correct disposal, the appliance must be consigned to an authorised waste
disposal company to ensure that all recyclable components are reused and the
remaining materials are processed properly.
• During installation ensure the room has adequate ventilation to prevent the build-
up of stale air that might be harmful to the health of the operators.
• During operation and maintenance ensure that any waste pollutant products (oil,
grease, etc.) are disposed of correctly.
• Keep noise levels down to reduce noise pollution.
For more information on correct dismantling of our products please refer to the
recycling handbooks at www.dometic.com.
➤ Place the packaging material in the appropriate recycling waste bins wherever
possible.
➤ When in operation or undergoing repairs and maintenance work, make sure that
the refrigerant circuit is not damaged and refrigerant cannot escape. It acts as a
greenhouse gas and should not be allowed into the environment.
If you wish to finally dispose of the product, ask your local recycling centre
or specialist dealer for details about how to do this in accordance with the
M
➤ Dispose of the product at an official waste disposal facility in accordance with the
B
applicable disposal regulations.
applicable recycling or disposal guidelines.
Protect the environment!
Do not dispose of any batteries with general household waste.
Return defective or used batteries to your retailer or dispose of them at
collection points.
19
EN
Technical dataFreshLight
11Technical data
Dometic FreshLight
16002200
Ref. no.:91029002079102900165
Cooling capacity based on ISO 5151:1500 W2050 W
Heating capacity:max. 2050 Wmax. 2700 W
Rated input voltage:230 Vw/50 Hz
Power consumption in cooling mode:
Required fuse:
Power consumption in heating mode:
Required fuse:
Operating temperature range:0 °C to +52 °C
Refrigerant:R407c
Refrigerant quantity:0.41 kg0.56 kg
equivalent:0.7273 t0.9934 t
CO
2
Global warming potential (GWP):1774
2.7 A
3A
3.5 A
4 A
4.1 A
5A
5.2 A
6 A
Blower:4 blower levels
1 automatic mode
Protection class:IP X4
Max. volume of space in the vehicle
(with insulated walls):
Bitte lesen Sie diese Anleitung vor Einbau und Inbetriebnahme sorgfältig
durch und bewahren Sie sie auf. Geben Sie sie im Falle einer Weitergabe
des Produktes an den Nutzer weiter.
Sicherheitshinweis: Nichtbeachtung führt zu Tod oder schwerer
Verletzung.
WARNUNG!
Sicherheitshinweis: Nichtbeachtung kann zu Tod oder schwerer
Verletzung führen.
VORSICHT!
Sicherheitshinweis: Nichtbeachtung kann zu Verletzungen führen.
ACHTUNG!
Nichtbeachtung kann zu Materialschäden führen und die Funktion des
Produktes beeinträchtigen.
HINWEIS
Ergänzende Informationen zur Bedienung des Produktes.
2Sicherheits- und Einbauhinweise
Beachten Sie die vom Fahrzeughersteller und vom Kfz-Handwerk vorgeschriebenen Sicherheitshinweise und Auflagen!
Der Hersteller übernimmt in folgenden Fällen keine Haftung für Schäden:
• Montage- oder Anschlussfehler
• Beschädigungen am Produkt durch mechanische Einflüsse und Über-
spannungen
• Veränderungen am Produkt ohne ausdrückliche Genehmigung vom Hersteller
• Verwendung für andere als die in der Anleitung beschriebenen Zwecke
Beachten Sie folgende grundsätzliche Sicherheitsmaßnahmen beim Gebrauch von
elektrischen Geräten zum Schutz vor:
• elektrischem Schlag
• Brandgefahr
• Verletzungen
23
DE
Sicherheits- und EinbauhinweiseFreshLight
2.1Umgang mit dem Gerät
WARNUNG!
!
!
• Die Montage und Reparaturen der Dachklimaanlage dürfen nur von
Fachkräften durchgeführt werden, die mit den verbundenen
Gefahren bzw. den einschlägigen Vorschriften vertraut sind. Durch
unsachgemäße Reparaturen können erhebliche Gefahren entstehen.
Wenden Sie sich im Reparaturfall an den Service-Stützpunkt in Ihrem
Land (Adressen auf der Rückseite).
• Elektrogeräte sind kein Kinderspielzeug!
Kinder können Gefahren, die von elektrischen Geräten ausgehen,
nicht richtig einschätzen. Lassen Sie Kinder nicht ohne Aufsicht
elektrische Geräte benutzen.
• Personen (einschließlich Kinder), die aufgrund ihrer physischen,
sensorischen oder geistigen Fähigkeiten oder ihrer Unerfahrenheit
oder Unkenntnis nicht in der Lage sind, das Gerät sicher zu benutzen,
sollten dieses Gerät nicht ohne Aufsicht oder Anweisung durch eine
verantwortliche Person nutzen.
• Im Falle von Feuer lösen Sie nicht den oberen Deckel der Dach-
klimaanlage, sondern verwenden Sie zugelassene Löschmittel.
Verwenden Sie kein Wasser zum Löschen.
VORSICHT!
• Die Dachklimaanlage muss so sicher installiert werden, dass diese
nicht herabfallen kann.
• Betreiben Sie die Dachklimaanlage nur, wenn das Gehäuse und die
Leitungen unbeschädigt sind.
• Setzen Sie die Dachklimaanlage nicht in der Nähe von entflammbaren
Flüssigkeiten oder in geschlossenen Räumen ein.
• Achten Sie darauf, dass brennbare Gegenstände nicht im Bereich des
Luftaustritts gelagert bzw. montiert sind. Der Abstand muss mindestens 50 cm betragen.
• Greifen Sie nicht in Lüftungsauslässe, und führen Sie keine Fremdgegenstände in die Anlage ein.
A
24
ACHTUNG!
• Benutzen Sie das Gerät nur zu seinem bestimmungsgemäßen
Gebrauch.
• Die Dachklimaanlage ist nicht für den Betrieb in Land- und Baumaschinen geeignet.
DE
FreshLightZielgruppe dieser Anleitung
• Führen Sie keine Änderungen oder Umbauten am Gerät durch.
• Bei angebauter Dachklimaanlage dürfen Sie auf keinen Fall mit Ihrem
Wohnmobil in die Waschanlage fahren.
• Treten Fehler im Kältemittelkreislauf der Anlage auf, so muss die
Anlage von einem Fachbetrieb geprüft und ordnungsgemäß instand
gesetzt werden. Auf keinen Fall darf das Kältemittel in die freie
Atmosphäre abgelassen werden.
HINWEIS
I
2.2Umgang mit elektrischen Leitungen
!
!
• Bitte informieren Sie sich bei Ihrem Fahrzeughersteller, ob aufgrund
des Aufbaus der Dachklimaanlage (Aufbauhöhe 210 mm) eine
Abnahme (nach § 19 StVZO) und eine Änderung des Eintrags der
Fahrzeughöhe in den Fahrzeugpapieren notwendig sind.
WARNUNG!
• Der elektrische Anschluss darf nur von einem Fachbetrieb durchgeführt werden (z. B. in Deutschland VDE 0100, Teil 721).
VORSICHT!
• Befestigen und verlegen Sie Leitungen so, dass keine Stolpergefahr
entsteht und eine Beschädigung des Kabels ausgeschlossen ist.
ACHTUNG!
A
• Müssen Leitungen durch scharfkantige Wände geführt werden, so
verwenden Sie Leerrohre bzw. Leitungsdurchführungen.
• Verlegen Sie keine losen oder scharf abgeknickten Leitungen an
elektrisch leitenden Materialien (Metall).
• Ziehen Sie nicht an Leitungen.
3Zielgruppe dieser Anleitung
Diese Anleitung richtet sich an Facharbeiter in Werkstätten, die mit den anzuwendenden Richtlinien und Sicherheitsvorkehrungen vertraut sind.
25
DE
LieferumfangFreshLight
4Lieferumfang
Nr. in Abb. 1AnzahlBezeichnung
11Dachklimaanlage
21Luftauslasseinheit
33Befestigungsbügel
44Luftfilter
52Filterabdeckung
64Dichtung
73Kabelverbinder
86Lange Befestigungsschraube
96Kurze Befestigungsschraube
104Abdeckkappe
111Fernbedienung
5Zubehör
Als Zubehör erhältlich (nicht im Lieferumfang enthalten):
TeilebezeichnungArtikelnummer
DC-Erweiterungskit DC-Kit29100300001
DC-Erweiterungskit DC-Kit39100300002
DC-Erweiterungskit DC-Kit59100300073
HINWEIS
I
Mit einem DC-Erweiterungskit (Zubehör) kann die Dachklimaanlage
Dometic FreshLight für den Fahrbetrieb erweitert werden.
26
DE
FreshLightBestimmungsgemäßer Gebrauch
6Bestimmungsgemäßer Gebrauch
Die Dachklimaanlage Dometic FreshLight mit integriertem Dachfenster ist in der
Lage, die Innenräume von Wohnmobilen und Caravans mit kühler oder warmer Luft
zu klimatisieren.
Die Dachklimaanlage ist nicht für die Montage in Baumaschinen, Landmaschinen
oder ähnlichen Arbeitsgeräten geeignet. Bei zu starker Vibrationseinwirkung ist eine
ordnungsgemäße Funktion nicht gewährleistet.
Betreiben Sie die Dachklimaanlage nicht bei Umgebungstemperaturen über 52 °C.
Betreiben Sie die Dachklimaanlage im Klimamodus „Heizen“ nicht bei Raum-
temperaturen über 30 °C.
Der Heizbetrieb wird bei Außentemperaturen von über +2 °C empfohlen.
HINWEIS
I
Weitere Informationen zur Dachklimaanlage wie die technische
Beschreibung oder Bedienung finden Sie in der Bedienungsanleitung.
7Kennzeichnungsschilder
An der Dachklimaanlage Dometic FreshLight sind Kennzeichnungsschilder
angebracht. Diese Kennzeichnungsschilder informieren den Anwender und den
Installateur über Gerätespezifikationen.
27
DE
MontageFreshLight
8Montage
VORSICHT! Verletzungsgefahr!
!
8.1Hinweise zur Montage
Vor der Montage der Dachklimaanlage muss diese Montageanleitung vollständig
gelesen werden.
Folgende Tipps und Hinweise müssen bei der Montage der Dachklimaanlage
beachtet werden:
D
!
Die Montage der Dachklimaanlage darf ausschließlich von entsprechend ausgebildeten Fachbetrieben durchgeführt werden. Die
nachfolgenden Informationen richten sich an Fachkräfte, die mit den
anzuwendenden Richtlinien und Sicherheitsvorkehrungen vertraut sind.
GEFAHR! Lebensgefahr durch Stromschlag!
Unterbrechen Sie bei Arbeiten an der Dachklimaanlage alle Spannungsversorgungen.
VORSICHT! Verletzungsgefahr!
• Eine falsche Montage der Klimaanlage kann zu irreparablen Schäden
am Gerät führen und die Sicherheit des Benutzers beeinträchtigen.
• Wenn die Dachklimaanlage nicht gemäß dieser Montageanleitung
installiert wird, übernimmt der Hersteller keinerlei Haftung, weder
für Betriebsstörungen noch für die Sicherheit der Dachklimaanlage,
insbesondere nicht für Personen- und/oder Sachschäden.
• Tragen Sie bei allen Arbeiten die vorgeschriebene Schutzbekleidung (z .B. Schutzbrille, Schutzhandschuhe).
A
28
ACHTUNG! Beschädigungsgefahr!
• Beachten Sie beim Einbau der Dachklimaanlage stets die Statik des
Fahrzeugs und die Abdichtung aller beim Einbau entstandenen
Öffnungen.
• Bevor Sie das Fahrzeugdach besteigen, prüfen Sie, ob dieses für
Personen begehbar ist. Zulässige Dachlasten können Sie beim
Fahrzeughersteller erfragen.
Loading...
+ 280 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.