Dometic BR36H70CR, BR36C71CR User Manual

C F
°
°
MODE
FAN
Wall Mounted Control
User‘s Guide
Cold mode
Dehumidification mode
Heat pump mode
Ventilation mode
Timer
Fan speed
Select mode
Select fan speed
Power ON/OFF
Increase/decrease temperature set-point
ON/OFF
Infrared receiving
window
Dometic Australia Pty Ltd
ABN 620 086 366 305
Tel: 61 75507 6000 Fax: 61 75507 6001
Contact Details:
1 John Duncan Court Varsity Lakes, QLD 4227
Email: sales@dometic.com.au
P/N. 54-AA-MA38702
MOBICOOL Electronic(Zhuhai)Co.,Ltd
18,Jinhu Lu,Sanzao,Jinwan Zhuhai,China
Notice: The function of timer must use remote controller.
The remote controller is optional fitment.
M COMP
θ θ
POWER
POWER
L N
Wiring Diagrams
Heat pump
BR36H70CR
Air conditioner
BR36C71CR
Wire connection
C F
°
°
MODE
FAN
The basic steps for operating your Air Conditioner or Heat Pump are described in
this User‘s Guide. For more detailed information on modes of operation and special
features refer to the Operating Instructions Manual.
Quick reference to control buttons
4445101808 08/2016
C F
° °
MODE
FAN
Fault condition
Room temperature sensor fault
Communication fault
Defrosting instructions
Digital display code
E1 E2 E3 E4 H1
Evaporator sensor fault
Condenser sensor fault
Note
Call for service
Call for service Call for service Call for service
Indicates defrosting in progress
Note
OPT:condenser sensor temperature.
IPT:evaparator sensor temperature.
48°C
compressor will be contiunted
60°C, compressor is not working.
A. Preventing cold air function:
When heat mode is selected, the internal fan will not start until the air within the air conditioner is
B. Blowing surplus heat function:
In heating mode, the fan will continue to run for appro­ximately 60 seconds aer the OFF button is pressed.
C. Defrosting function:
At low ambient temperatures approximately –5°C
the heating mode will periodically enter a defrosting
D. Overheat protection
48°C,
heated. This is to prevent cold air blowing into the
In heating mode, detection of the evaparator temperature IPT,
The compressor will keep
the original state.
when IPT
<
IPT
55°C.
when IPT
when
living space during start up.
mode.
Press “MODE” button select auto, cold,
d.
Press “ON/OFF” button switch on
Operation
a.
Press “+” button increase set
b.
temperature point.
c.c.
or switch off the machine.
dehumidification, heat, and fan mode.
Press “FAN” button adjust the high
Press “–” button decrease set temperature point.
or middle and low speed of the motor.
working.
FAULT CODE & FUNCTION DESCRIPTIONS
Installation Instructions
Step One :
Remove the cover of wall mounted control box.
Step Two :
Remove the button from wall mounted control box.
Step Three :
According to the drawing install three screws one by one.
Step One
Step Two
Step Three
Step Four
Step Four :
Finally install the button and cover again.
C F
°
°
MODE
FAN
C F
°
°
MODE
FAN
C F
°
°
MODE
FAN