D-Link DES-7206, DES-7210 Quick Installation Manual

DES-7200 Series Quick Installation Guide
DES-7200 Series Quick Installation Guide
Revision No.: V1.1 Date:2007/8/16
Copyright statement All rights reserved.
D-Link Corporation reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of D-Link Corporation is prohibited.
Exemption statement
This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the D-Link Corporation website. D-Link Corporation endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
Contents
Product Overview....................................................................................................................................3
Safety Precautions for Removing ...........................................................................................................3
Preparation Before Installation................................................................................................................4
Temperature and Humidity Requirements .................................................................................... 4
Static Discharge Damage Prevention ........................................................................................... 4
System Grounding Requirements.................................................................................................5
Power Requirements ....................................................................................................................5
Requirements of Installation Tools ................................................................................................6
Installation Site Requirements ................................................................................................................7
Requirements for Rack Mounting .................................................................................................7
Ventilation Requirements ..............................................................................................................7
Mounting the DES-7210/7206 into the Cabinet ............................................................................8
Installing the Fan Tray...................................................................................................................8
Installing the Power Supply...........................................................................................................9
Installing the Handle ...................................................................................................................10
Installing the Cabling Rack of the DES-7210..............................................................................11
Installing the Air Filter of the DES-7210...................................................................................... 11
Connecting the System Ground..................................................................................................12
Connecting the DC Power Supply to the Power Module............................................................12
Connecting the AC Power Supply to the Power Module ............................................................13
Connecting the Cable of the Management Module ....................................................................14
Removing Boards from the DES-7210/7206 ..............................................................................14
Installing Boards on the DES-7210/7206....................................................................................15
Installation Check........................................................................................................................15
Unpacking Inspection Requirements ....................................................................................................16
Checking Goods .........................................................................................................................16
i
DES-7200 Series Quick Installation Guide
Product Overview
D-Link Corporation introduces high-density multi-service IPv6 core router switch DES-7200 by sparing great efforts, after the release of the multi-service 10,000M core router switch DES-7200 being applicable to the backbone Ethernet. DES-7200, as a multi-service IPv6 10,000M core router switch of the new generation, provides powerful defense ability while ensuring high performance and large capacity. It also boasts the ability of service addition and expansion on demand, thus satisfying the design requirements of equal emphasis on service and performance. Currently, two models are available, DES-7206 and DES-7210, which offer ten vertical slots and six horizontal slots respectively.
The DES-7210 series multi-service Ipv6 10,000M core router switch provides users with high-speed non-blocking data switching. With powerful switching and routing functions and secure intelligent technologies, it can be used together with various series of D-Link switches to provide users with complete end-to-end solutions. It is ideal for large-scale network core backbone and heavy traffic node switch. By expanding with high-performance multi-service cards, the DES-7200 series switches support policy routing and IPV6, and satisfies customers’ flexible and complex application requirements.
Applications:
Core layers of such enterprise networks of educational, financial and governmental
organizations
Running environment that needs powerful routing function and carrier-class security &
reliability
High-layer switching of enterprise networks with high bandwidth and 10G needs
Enterprise environment that needs to provide high QoS assurance for various
applications
Safety Precautions for Removing
The DES-7210/7206 is large and heavy. When you handle them, please pay attention to the following requirement:
Avoid moving the equipment frequently.
At least two people are needed to move the equipment. Do not attempt to move the
equipment by one person only.
Keep balanced in moving the equipment, and avoid injuring your leg and feet or
spraining your waist.
Turn off all power supplies and unplug all power cables before you can remove the
equipment.
First remove all the line cards, fan tray, and power module from the chassis before you
can move the DES-7210/7206 by using the handles on both sides, to avoid any damage.
3
DES-7200 Series Quick Installation Guide
Correctly Moving the DES-7210 and DES-7206
Warning
Do not move the equipment by grasping the panel, power supply handle, ventilation holes of the chassis, as they are not designed to bear the weight of the entire equipment. Failing to do so may cause damage or even injure yourself.
Preparation Before Installation
Temperature and Humidity Requirements
To ensure the normal working and a prolonged useful life of the DES-7210/7206, appropriate temperature and humidity must be maintained in the equipment room.
If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment may be damaged.
Temperature and Humidity Requirements of the DES-7210/7206
Temperature Relative Humidity
Long-term condition Short-term condition Long-term condition Short-term condition
0ºC-45ºC 0ºC-45ºC 40%-65% 10%-90%
Note
1. The ambient temperature and humidity are measured at the point that is
1.5m above the floor and 0.4m before the equipment when there is no protective plate in front or back of the equipment rack.
2. The short-term working condition applies where the continuous working period does not exceed 48 hours and the accumulative total period within a year does not exceed 15 days.
Static Discharge Damage Prevention
To prevent damage from static electricity, you must pay attention to the following:
1. Proper grounding of the equipment and floor
2. Dust prevention measures are taken in the room.
4
Loading...
+ 12 hidden pages