DewertOkin RF258B User Manual

Page 1
Control unit 300 Series
mounting + operating
Page 2
1 Overview
This control unit is designated to operate an electrically driven bed with optional comfort functions.
Power supply is provided via SMPS so the control box has protection class III.
The system is operated with an RF remote. The RF receiver is integrated into the
control unit.
Bed view from beneath
Actuator 1
Massage motor 1
Actuator 2
Massage motor 2
Control unit
Here for example you can see a control unit with two actuators and two massage motors connected
October 31, 2012 Page 2 of 10
Page 3
Control Unit 258-2 CU258-2
2 Mounting the control unit
This mounting bracket is fixed on the flipside of the bed
These two bolts fix the position of the control unit between the mounting bracket.
The clip snaps in the holding fixtures of the control unit
October 31, 2012 Page 3 of 10
Page 4
October 31, 2012 Page 4 of 10
Page 5
Performance data control unit
Duty cycle 2/18 min. or 10 %, max, 5 switching cycles per minute Output voltage 29 V / 6A
Further features
Housing colour black RAL 9005 Housing material ABS + PC Ports drives: 2 actuators / 2 vibration motors
Indicators + buttons Reset + pairing button / Pairing LED for RF
Protection type IP20 Protection class III Relative humidity 30% - 75% Ambient temperature +50°F - +104°F Power supply external
power input 1 / multifunction output 1
Power LED
Integrated RF receiver
1
Key Function
1 Pairing enable
Performance data RF receiver
modulation GFSK Frequency Range 2.403~2.480GHz Transmitted Power 0 dBm Battery 30V supply voltage Working Current <60mA Standby Current <20mA Ambient Temperature
-40—85Ԩ
PCB Material & Size FR4 1.6mm 120*120mm
October 31, 2012 Page 5 of 10
Page 6
2.1 Power supply PD12 65444
Connecting cable73178 to control box
Power supply cable 3.00.401.151.30 to mains power
Performance data
Output voltage 29 V DC con stant voltage output
Components
Indicators LED operating status indication (green) Colour black RAL 9005
Further data
Protection type IP20 Protection class II Relative humidity 30% - 75% Ambient temperature +50°F - +104°F Power supply wide in put voltage range 100-240 V AC Safety NTC temperature sensor, primary fuse, overload
protection, overcurrent switch-off, short-circuit-proof output
October 31, 2012 Page 6 of 10
Page 7
Remote Control 258B
2.2 RF258B
Frontside
1 2 3
4 5 6 7 8 9
10 11 12
Pairing button & battery box (flipside)
Insert 3x AAA
13
Keys for fixed positions
Choose between comfortable positions
Manual adjustment keys
Move head & foot rest up and down manually
Massage keys
X With the timer key you program
duration and stop the massage function.
X The LEDs signal the programmed
duration, the key below starts the massage. With the Head & Foot keys you can select the massage zones.
Key Function
1 Massage Head ON 2 Adjust Massage timer 3 Massage Foot ON 4 Move bed in TV position 5 Start both Massage (Head and Foot) 6 Move bed in Lounge position 7 Relay 1 on 8 Move bed in Flat position
9 Relay 3 on 10 Relay 2 on 11 Move bed in Zero G position 12 Relay 4 on
13 Pairing
October 31, 2012 Page 7 of 10
Page 8
Performance data remote (RF transmitter)
Modulation GFSK Frequency Range 2.403~2.480GHz Battery AAA Working Current <40mA Standby Current <8uA Ambient Temperature
-40—85Ԩ
RC Dimension 145*50*14mm PCB Material & Size FR4 1.6mm 79*42mm Housing Material ABS+PC
October 31, 2012 Page 8 of 10
Page 9
3 Board Schematics (remote)
3.1 Remote
3.2 RX module
_
Pls insert diagram
October 31, 2012 Page 9 of 10
Page 10
4 Functional Description
Take cable 3.00.401.151.30 and connect it to mains supply.
The system is delivered paired!
You can test the functions of the system with the RF remote.
Pairing instruction (in case of trouble)
Pairing the remote with the control box.
The distance between remote and control box for pairing should be less than 2 meters!
1. Remove the battery cover on the flipside of the remote.
2. Insert/check existing 3x AAA batteries.
3. Push the reset button on the control box twice with something spiky. The green pairing LED adjoining is lit.
Now you have 10 s to pair remote and receiver.
4. On the flipside of the remote is a silicone push button positioned above the batteries (13). A blue LED starts blinking as the button is pressed. Keep it pressed until the blue LED is lit continuously, then pairing is completed, the blue LED light fades away.
This device complies with Industry Canada licence­exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement."
RSS-102 Statement: This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled environment. Déclaration CNR-102: Cet équipement est conforme à l'exposition aux rayonnements Industry Canada limites établies pour un environnement non contrôlé.
October 31, 2012 Page 10 of 10