Deta L1052WH, L1052CH, L1055WH, L1055CH Installation Instructions

L1052WH
L1052CH
L1055WH
L1055CH
S16
NPD 0483 0815 V2
Safety Instructions
Before installation ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed, or the
circuit breaker is turned off
Check that the total load on the circuit with this luminaire does not exceed the rating of the circuit cable, fuse or circuit breaker This fitting must be installed in accordance with the current IEE wiring regulations. This luminaire should not be use for periods exceeding 24hours continuously
Operation – Microwave Sensor (where fitted)
Detection Range:
This determines the effective range of the motion detector and is set by DIP switches on the sensor itself, refer to figure. Note that reducing the sensitivity will narrow the detection range. The following settings are available:
i. Maximum up to 5m ii. Range up to 3.5m iii. Range up to 2m iv. Range up to 1.5m v. Range up to 1m
Hold Time:
This determines the time the fitting remains at 100% level after motion is last detected and is set with DIP switches at the sensor itself, refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range. The following settings are available:
i. walk test mode ii. 30s iii. 3 minutes iv. 5 minutes v. 15 minutes vi. 25 minutes
Daylight Sensor:
This setting holds off the 100% light output should there be sufficient daylight and is set using DIP switches at the sensor, refer to figure. The following settings are available:
i. 2 lux darkness only ii. 5 lux darkness only iii. 20 lux twilight iv. 30 lux twilight v. *daylight, photocell disabled.
*In daylight setting the lamps will always be on with motion detection and operate at 100% light output, even in bright daylight.
Nimbus
14W LED Round Bulkhead
To be read in full before installation and kept for future reference.
Tel: +44 (0) 1582 544 544
Deta Electrical Company Limited
Kingsway House | Laporte way
Luton | Bedfordshire | LU4 8RJ | UK
Technical Helpline +44 (0) 1582 544 548
L1052WH
L1052CH
L1055WH
L1055CH
S16
NPD 0483 0815 V2
Power Supply
230-240V 50Hz
Construction
Class II (must be earthed)
Wattage
14W
Lamp Type
SMD LED (88pcs)
Lamp Colour Temperature
4000k
LED Life (average)
30, 000 hrs
CRI
Ra 80
IP Rating
IP44
Installation Instructions
Remove the diffuser from the base by turning it 45° anti-clockwise and pulling it away from the base
Fig 1
Loosen but do not remove the gear tray retaining screws Adjust the position of the gear tray to align the hole in the keyhole slots with the retaining screws,
and remove the gear tray from the base – Fig 2
Select a suitable cable entry point provided, or by drilling into the base. Route supply cable into the
luminaire through selected cable entry ensuring that the hole is smooth and a grommet is fitted to maintain the IP rating of the luminaire – Fig 3
Position and fix the base to a suitable solid surface using screws supplied Terminate the cable into the terminal block mounted on the underside of the gear tray ensuring
correct polarity is observed and the luminaire is earthed – Fig 4
Replace the gear tray and retighten the retaining screws – Fig 5 Re-fit the diffuser by placing it over the base and turning it clockwise until it locks into position – Fig 6
Bezel Change Instructions
Remove the diffuser from the base by turning it 45° anti-clockwise and pulling it away from the base Separate the diffuser from the bezel by carefully using a flat bladed screwdriver to releasing the
three retaining clips along the inside of the bezel.
Fit the diffuser into the new bezel and secure in position with the three retaining clips Re-fit the diffuser by placing it over the base and turning it clockwise until it locks into position
Fig 2
Fig 1
Fig 3
Fig 4
Fig 5
Fig 6
Tel: +44 (0) 1582 544 544
Deta Electrical Company Limited
Kingsway House | Laporte way
Luton | Bedfordshire | LU4 8RJ | UK
Technical Helpline +44 (0) 1582 544 548