14W LED Round bulkhead with Mircowave sensor – White bezel
14W LED Round bulkhead with Microwave sensor – Chrome bezel
14W LED Round bulkhead – White bezel
14W LED Round bulkhead – Chrome bezel
Safety Instructions
Before installation ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed, or the
circuit breaker is turned off
Check that the total load on the circuit with this luminaire does not exceed the rating of the circuit cable, fuse or circuit breaker
This fitting must be installed in accordance with the current IEE wiring regulations.
This luminaire should not be use for periods exceeding 24hours continuously
Operation – Microwave Sensor (where fitted)
Detection Range:
This determines the effective range of the motion detector and is set by DIP switches on the sensor itself, refer to figure. Note that
reducing the sensitivity will narrow the detection range. The following settings are available:
i. Maximum up to 5m
ii. Range up to 3.5m
iii. Range up to 2m
iv. Range up to 1.5m
v. Range up to 1m
Hold Time:
This determines the time the fitting remains at 100% level after motion is last detected and is set with DIP switches at the sensor itself,
refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range. The following settings
are available:
i. walk test mode
ii. 30s
iii. 3 minutes
iv. 5 minutes
v. 15 minutes
vi. 25 minutes
Daylight Sensor:
This setting holds off the 100% light output should there be sufficient daylight and is set using DIP switches at the sensor, refer to
figure. The following settings are available:
i. 2 lux darkness only
ii. 5 lux darkness only
iii. 20 lux twilight
iv. 30 lux twilight
v. *daylight, photocell disabled.
*In daylight setting the lamps will always be on with motion detection and operate at 100% light output, even in bright
daylight.
Nimbus
14W LED Round Bulkhead
To be read in full before installation and kept for future reference.
Tel: +44 (0) 1582 544 544
Deta Electrical Company Limited
Kingsway House | Laporte way
Luton | Bedfordshire | LU4 8RJ | UK
Technical Helpline +44 (0) 1582 544 548

14W LED Round bulkhead with Mircowave sensor – White bezel
14W LED Round bulkhead with Microwave sensor – Chrome bezel
14W LED Round bulkhead – White bezel
14W LED Round bulkhead – Chrome bezel
Class II (must be earthed)
Installation Instructions
Remove the diffuser from the base by turning it 45° anti-clockwise and pulling it away from the base
– Fig 1
Loosen but do not remove the gear tray retaining screws
Adjust the position of the gear tray to align the hole in the keyhole slots with the retaining screws,
and remove the gear tray from the base – Fig 2
Select a suitable cable entry point provided, or by drilling into the base. Route supply cable into the
luminaire through selected cable entry ensuring that the hole is smooth and a grommet is fitted to
maintain the IP rating of the luminaire – Fig 3
Position and fix the base to a suitable solid surface using screws supplied
Terminate the cable into the terminal block mounted on the underside of the gear tray ensuring
correct polarity is observed and the luminaire is earthed – Fig 4
Replace the gear tray and retighten the retaining screws – Fig 5
Re-fit the diffuser by placing it over the base and turning it clockwise until it locks into position – Fig 6
Bezel Change Instructions
Remove the diffuser from the base by turning it 45° anti-clockwise and pulling it away from the base
Separate the diffuser from the bezel by carefully using a flat bladed screwdriver to releasing the
three retaining clips along the inside of the bezel.
Fit the diffuser into the new bezel and secure in position with the three retaining clips
Re-fit the diffuser by placing it over the base and turning it clockwise until it locks into position
Tel: +44 (0) 1582 544 544
Deta Electrical Company Limited
Kingsway House | Laporte way
Luton | Bedfordshire | LU4 8RJ | UK
Technical Helpline +44 (0) 1582 544 548