Desa VP11, VP5A User Manual

®
G
I
D
S
I
N
N
A
E
S
T
D
C
E
R
T
I
I
F
I
E
A
M
C
R
A
S
O
C
I
A
O
N
®
GS
A
VENT-FREE PROPANE GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Models: VP5A and VP11
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per­sonal injury, or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be per-
formed by a qualified installer, service agency, or the gas supplier.
Save this manual for future reference.
W ARNING: Improper installation,
adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assis­tance or additional information consult a qualified installer, ser­vice agency, or the gas supplier.
CONTENTS
SECTION PAGE
Safety Information.........................................................................2
Product Identification .................................................................... 4
Local Codes ................................................................................... 4
Unpacking......................................................................................4
Product Features ............................................................................4
Installing To Wall..........................................................................5
Connecting To Gas Supply............................................................9
Checking Gas Connections............................................................10
Operating Heater ...........................................................................12
Inspecting Burner .......................................................................... 15
Cleaning And Maintenance ........................................................... 16
Troubleshooting.............................................................................17
Technical Service .......................................................................... 20
Specifications ................................................................................20
Service Hints .................................................................................21
Replacement Parts ......................................................................... 21
Service Publications ...................................................................... 21
Accessory ......................................................................................21
Parts List (Model VP5A)...............................................................22
Illustrated Parts Breakdown (Model VP5A) ................................. 22
Parts List (Model VP11)................................................................23
Illustrated Parts Breakdown (Model VP11) .................................. 23
Warranty Information .................................................................... Back Cover
SAFETY
INFORMATION
!
WARNINGS
WARNING ICON G 001
IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, and carbon monoxide poisoning.
!
DANGER
WARNING ICON G 001
Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning
resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor added to propane gas can fade. Propane gas may be present even though no odor exists.
Make certain you read and understand all Warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
2
Safety Information continued on next page
SAFETY
INFORMATION
Continued
!
WARNINGS
WARNING ICON G 001
1. Use only propane gas. Do not convert heater to use different fuel type.
2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
4. Never install the heater
• in sleeping quarters, a mobile home, or a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
5. Always run heater with control knob at LOW or HIGH locked positions (VP11) or ON position (VP5A). Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
Continued
6. Open window to admit fresh, outside air when using heater. Open window one or two inches. When used without fresh, outside air, heater may give off carbon monoxide gas.
7. Never run heater in small, closed room. Open door into next room to help ventilate.
8. Keep all air openings in the front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.
9. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
10.Do not run heater
• where flammable liquids or vapors are used or stored
• under dusty conditions
11.Never place any objects on the heater.
12.Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.
13.Make sure grill guard is in place before running heater.
14.Do not alter heater or its controls. Any change may create a safety hazard.
15.Do not use heater if any part of heater has been under water.
16.Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
17.Do not operate heater above elevations of 4,500 feet.
3
PRODUCT
IDENTIFICATION
Control Knob
Grill Guard
Burners
LOCAL CODES
UNPACKING
Front Panel
Figure 1 - Vent-Free Propane Gas Heater (Model VP11 Shown)
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Gas Code ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
Heater Cabinet
PRODUCT
FEATURES
Safety Device
This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
Piezo Ignition System
This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
4
INSTALLING
TO WALL
NOTICE
A qualified service person must install heater. Follow all local codes.
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
• external regulator (supplied by installer-see page 9)
• piping (check local codes)
• sealant (resistant to propane gas)
• manual shutoff valve *
* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional A.G.A. design-certified manual shutoff valve can be purchased from your dealer. See ACCESSORY, page 21.
• ground joint union
• test gauge connection * (see Figure 11, page 10)
• sediment trap
• tee joint
• pipe wrench
LOCATING HEATER
This heater is designed to be mounted on a wall.
!
WARNING
WARNING ICON G 001
Maintain the minimum clearances shown in Figure 2 (page 6). If you can, provide greater clearances from floor, ceiling, and joining wall.
!
WARNING
WARNING ICON G 001
Never install the heater
• in sleeping quarters, a mobile home, or a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
!
CAUTION
WARNING ICON G 001
Operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
!
CAUTION
WARNING ICON G 001
If you install the heater in a home garage
• heater pilot and burner must be at least 18 inches above floor
• locate heater where moving vehicle will not hit it
For convenience and efficiency, install heater
• where there is easy access for operation, inspection, and service
• in coldest part of room
Continued
5
CEILING
36" Minimum
8" Minimum From Sides Of Heater
Right
Left Side
FLOOR
Figure 2 - Mounting Clearances As Viewed From Front of Heater
Side
3"
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
INSTALLING HEATER TO WALL
Marking Screw Locations
1. Determine where you will locate heater.
!
WARNING
WARNING ICON G 001
Maintain minimum clearances shown in Figure 3. If you can, provide greater clearances from floor and joining wall.
2. Mark two mounting screw locations on wall (see Figure 3).
10 7/8"
Minimum To
Maintain 8"
Clearance From Wall
JOINING WALL
7 3/4"
Mounting
Screw
Locations
20 1/4"
Minimum To
Maintain 3"
Clearance
From Floor
FLOOR
Figure 3 - Mounting Screw Locations
6
Installing Two Mounting Screws
Note:
Wall anchors and mounting screws are in hardware package. The hardware
package is provided with heater.
Attaching to wall stud method
For attaching mounting screw to wall stud
1. Drill hole at marked location using 9/64" drill bit.
2. Insert mounting screw into wall stud.
3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall.
Attaching to wall anchor method
Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).
1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1 1/4" deep.
2. Fold wall anchor (see Figure 4).
Figure 4 - Folding Anchor
3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to
“pop” open anchor wings (see Figure 5).
IMPORTANT:
Do not hammer key!
For thick walls (over 1/2" thick) or solid walls, do not pop open wings.
Thin Walls (1/4" to 1/2" thick)
Figure 5 - Popping Open Anchor Wings For Thin Walls
5. Tighten two screws until 1/16" space (thickness of penny) is between screwheads and wall (see Figure 6).
Thin or Thick Wall (thick wall shown)
1/16" Space
Solid Wall
Figure 6 - Tightening Anchors
7
Placing Heater On Mounting Screws
1. Locate two keyhole slots on back panel of heater (see Figure 7).
2. Place large openings of slots over screwheads. Slide heater down until screws are in small portion of slots.
Keyhole Slots
Figure 7 - Location Of Keyhole Slots On Back Panel Of Heater
Removing Front Panel Of Heater
1. Remove two screws near bottom corners of front panel.
2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".
3. Pull bottom of front panel forward, then down.
Figure 8 - Removing Front Panel Of Heater
Installing Bottom Mounting Screw
1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 9).
2. Mark screw location on wall.
3. Remove heater from wall.
4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 7. If installing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit.
5. Replace heater on wall.
6. Insert bottom anchor screw through back panel into bottom anchor or drilled hole (see Figure 9).
7. Tighten screw until heater is firmly secured to wall. Do not over tighten.
Note:
Do not replace front panel at this time. Replace front panel after making
gas connections and checking for leaks (see pages 9-11).
8
Figure 9 - Installing Bottom Mounting Screw
Loading...
+ 16 hidden pages