VENTED DECORATIVE NATURAL GAS LOGS
OWNER’S OPERATION AND
INSTALLATION MANUAL
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Vanguard Burner Models VVSR18, VVSR24, VVDR18, VVDR24, and VVDR30
For Use with Log Sets: Hanover Round Oak Log Models VSLR18 and VSLR24 Kingston Split Oak Log Models VDLCR18, VDLCR24 (Shown), and VDLCR30
FMI Burner Models FVSR18, FVSR24, FVDR18, FVDR24, and FVDR30
For Use with Log Sets: Arlington Round Oak Log Models FSLR18 and FSLR24 Manchester Split Oak Log Models FDLCR18, FDLCR24 and FDLCR30
Comfort Glow Oxford Oak Log Set and Burner Models:
CVSR18 and CVSR24
Comfort Glow Amherst Oak Log Set and Burner Models:
CPVSR18 and CPVSR24
Comfort Glow Berkshire Oak Log Set and Burner Models:
CVDR18, CVDR24, and CVDR30
Comfort Glow Shenandoah Oak Log Set and Burner Models:
LBFL18 and LBFL24
Comfort Glow Conventry Oak Log Set and Burner Models:
LVDR18, LVDR24 and LVDR30
Comfort Glow Mendocino Oak Log Set and Burner Models:
BFLT18 and BFLT24
Comfort Glow Malibu Drift Log Set and Burner Models: MD18 and MD24
RGA 2-72
APPROVED
TESTED AND
LISTED BY
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result caus­ing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assis­tance or additional information con­sult a qualified installer, service agency, or the gas supplier.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
WARNING: This appliance is for installation only in a solid-fuel burn­ing masonry or UL127 factory-built fireplace, constructed of noncom­bustible material, and connected to a working flue. (See page 7 for minimum flue opening.)
WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to the
National
Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Save this manual for future reference.
Save this manual for future reference.
Page 2
TABLE OF CONTENTS SAFETY INFORMATION
2
TABLE OF CONTENTS
SAFETY INFORMATION ............................................................ 2
PRODUCT IDENTIFICATION ..................................................... 3
LOCAL CODES........................................................................... 3
UNPACKING............................................................................... 3
OPTIONAL PRODUCT FEATURES ........................................... 3
INSTALLATION ........................................................................... 4
OPERA TING APPLIANCE ........................................................ 10
CLEANING AND MAINTENANCE .............................................11
SAFETY INFORMATION
WARNINGS
WARNING ICON G 001
WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
WARNING: Keep flue open when operating unit.
IMPORTANT: Read this owners manual carefully and completely before trying to assemble, operate, or ser­vice this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of carbon monoxide
poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-making agent is
added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this log set.
WARNING: Any change to this log set or its controls can be dangerous.
1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This appliance is convertible for use with propane/LP, using the GA9050A or GA9150A pilot kit.
SERVICE HINTS........................................................................11
TECHNICAL SERVICE ..............................................................11
REPLACEMENT PARTS ........................................................... 11
TROUBLESHOOTING .............................................................. 12
ACCESSORIES ........................................................................ 15
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 16
OWNER’S REGISTRATION FORM........................................ ..29
WARRANTY INFORMATION ...................................... Back Cover
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions
• if you cannot reach your gas supplier, call the fire department
3. Never install the log set
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable ob­jects are less than 42 inches from the front, top, or sides of the log set
• in high traffic areas
• in windy or drafty areas
4. Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ig­nite if highly heated. Inspect chimney flue for damage. If dam­aged, repair flue before operating heater.
5. You must operate this l og s et with a fireplace screen in place. Make sure fireplace screen is closed before running log set.
6. This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person.
Note:
During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.
7. T o reduce the creation of soot, follow the instructions in Clean- ing and Maintenance, page 11.
8. Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.
9. Do not use a blower insert, heat exchanger insert or other ac­cessory not approved for use with this log set.
10. The installation and provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z233.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 3
SAFETY INFORMATION
PRODUCT IDENTIFICATION
LOCAL CODES
UNPACKING
OPTIONAL PRODUCT FEATURES
3
3
SAFETY INFORMATION
Continued
11. Do not run log set
• where flammable liquids or vapors are used or stored
• under dusty conditions
12. Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.
13. Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set will remain hot for a time after shutdown. Allow surface to cool before touching.
14. Carefully supervise young children when they are in the room with log set.
15. Do not use appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the control sys­tem (if using GA9050A or GA9150A) and any gas control which has been under water.
16. To help prevent breakage, new logs must be broken-in (see Curing Logs page 10).
17. Turn log set off and let cool before servicing, installing, or repair­ing. Only a qualified service person should install, service, or re­pair log set.
18. Provide adequate clearances around air openings.
LOCAL CODES
Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
CAUTION: Do not remove the data plates from the burner pan. The data plates contain important prod­uct information.
1. Remove logs, hearth kit, pan materials, and hardware from carton.
2. Remove all protective packaging applied to logs and base for shipment.
3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.
PRODUCT IDENTIFICATION
Grate Steps
Grate
Burner Pan
Figure 1 - Product Identification (Dual Burner Shown)
Hearth Kit Model _________________________ Serial Number ___________________________ Log Set Model ___________________________
Burner Clamp
Burner Manifold
Burner Inlet Fitting
OPTIONAL PRODUCT FEATURES
ON/OFF SAFETY VALVE/PILOT KIT AND PROPANE/LP CONVERSION
An optional valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. You must use this optional system for LP conver­sion. See Accessories, page 15.
REMOTE CONTROL READY (MILLIVOLT) SAFETY VALVE/PILOT KIT
An optional millivolt valve/safety pilot kit with a piezo ignitor is available for this appliance. This system requires no matches, batteries, or other sources to light. This system may be connected to a wall switch or hand-held wireless remote control. See Accessories, page 15.
REMOTE CONTROL ACCESSORIES
There is an optional hand-held ON/OFF remote control that can be purchased separately for this log set. You must use the millivolt valve/safety pilot kit to use remote accessories with this appliance. See Accessories, page 15.
A wall switch is also available for this appliance. You must use the millivolt valve/safety pilot kit to use the wall switch with this appliance. See Accessories, page 15.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 4
INSTALLATION
4
Flue Opening Specifications Check Gas Type Venting Specifications for Installation
INSTALLATION
CAUTION: Do not remove the data plates attached to the burner pan. The data plates contain important warranty information.
WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating heater.
NOTICE: Installation, service, and repair of this appli­ance must be performed by a qualified installer, service agency, company or gas supplier experi­enced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or acces­sory items will void the manufacturer’s warranty, and may result in a hazardous condition.
FLUE OPENING SPECIFICATIONS
Note:
This vented appliance must be installed only in a solid-fuel
burning fireplace with a working flue and constructed of noncom­bustible material.
The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, you must install ON/OFF Safety Valve/Pilot Kit (see Accessories, page 15). Call dealer where you bought log set.
If the fireplace does not have a gas supply shutoff valve, one must be installed.
VENTING SPECIFICATIONS FOR INSTALLATION
The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.
The chimney flue must remain open a minimum of 3" at all times during the operation of this log set.
MODEL DESCRIPTION
BURNER
VVSR18 18" Single 50,000 40,000 8" dia. FVSR18
VVSR24 24" Single 60,000 50,000 8" dia. FVSR24
VVDR18 18" Dual 55,000 45,000 8" dia. FVDR18 MD18
VVDR24 24" Dual 65,000 55,000 8" dia. FVDR24 MD24
VVDR30 30" Dual 70,000 60,000 8" dia. FVDR30
LBFL18 18" Triple 65,000 55,000 8" dia. BFLT18
LBFL24 24" Triple 70,000 60,000 8" dia. BFLT24
MINIMUM FIREBOX SIZES
FRONT BACK
MODEL WIDTH* WIDTH** DEPTH HEIGHT
18DR/SR 28" 16" 14" 18" MD18
24DR/SR 29 3/4" 17" 15 1/2" 18" MD24
30DR 36" 27" 18" 18" BFL18 28" 16" 15 1/2" 18" BFL24 30" 22" 15 1/2" 18"
*Add 6" if safety valve/pilot is used **At depth indicated
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
NG 5.5" 10.5" LP 11" 13"
LOG NATURAL PROPANE/LP SIZE IN. NUM. IN. NUM.
18SR/DR .120 31 .073 49 MD18/18SR/DR
24SR/DR/BFL18 .129 30 .086 44 MD24/24SR/DR/BFL18
30DR/BFL24 .1405 28 .089 43
Btu Input
Natural Gas
Min. Max.
BURNER ORIFICE
Btu Input
Propane/LP
Gas
Minimum
Vent Opening
Figure 2 - Technical Information Charts
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 5
INSTALLATION
Continued
Installing Damper Clamp
INSTALLATION
Connecting to Gas Supply
5
5
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 3. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.
Damper Clamp
Damper
Masonry Fireplace
Figure 3 - Attaching Damper Clamp
Manufactured Fireplace
Damper
Damper Clamp
Damper
CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must con­nect log set to gas supply. Follow all local codes.
Installation Items Needed
Before installing log set, make sure you have the items listed below.
• piping (check local codes)
• sealant (resistant to Propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 4).
IMPORTANT:
Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as shown in Figure 4. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.
Approved Flexible Gas Hose (if allowed by local codes)
CSA Design-Certified Equipment Shutoff Valve With 1/8" NPT Tap*
3" Minimum
Cap
Figure 4 - Gas Connection
Pipe Nipple
Sediment Trap
From Gas Meter (5" W.C.** to 10.5" W.C. Pressure)
Tee Joint
CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diam­eter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of volume will occur.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 15.
** Minimum inlet pressure for purpose of input adjustment.
Page 6
INSTALLATION
6
Checking Gas Connections Hearth Kit Assembly and Installation
INSTALLATION
Continued
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.
Pressure Testing Gas Supply Piping System
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect log set and its individual equipment shutoff valve from gas supply piping system.
2. Cap off open end of gas pipe where equipment shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Reconnect log set and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 5).
2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.
3. Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Equipment Shutoff Valve
Gas Meter
HEARTH KIT ASSEMBLY AND INSTALLATION
Kit Assembly - Single and Dual-Flame Only
1. Determine which side the gas line will be coming into the fireplace.
NOTICE: Triple-burner models CBL18/24 or BFLT18/24 come preassembled with gas inlet on right side of burner pan. DO NOT attempt to reposition burner on triple-burner models. If your fireplace supply is on the left side, a longer 3/8" flex line should be purchased and routed behind burner pan and away from flame area.
2. Using a hammer and screw driver, remove knockout plug from the side of the pan that corresponds to the gas line (see Figure 6).
3. Unscrew burner inlet fitting from burner manifold.
4. Place burner manifold in pan with threaded opening facing open knockout plug.
5. Using thread sealant (resistant to the action of propane/LP gas) on larger end of fitting, screw the burner inlet fitting through hole and into burner manifold (see Figure 6). Tighten using a wrench. If using propane/LP gas, see Propane/LP Gas Conversion, page 8.
Nut
Burner Manifold
Knockout Plugs
Knockout Plugs
Burner Pan (Front)
SINGLE-BURNER DUAL-FLAME
Front Burner
Burner Pan (Front)
Burner Inlet Fitting
Burner Manifold
Burner Clamp
Burner Inlet
Screw
Fitting
Gas Connection Must Be On Right Side For Triple Burner
Figure 5 - Checking Gas Joints
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Burner Pan (Front)
TRIPLE-BURNER
Figure 6 - Installing Burner
Burner Inlet Fitting
901265-01K
Page 7
INSTALLATION
Continued
Hearth Kit Assembly and Installation (Cont.)
INSTALLATION
Optional GA9050A ON/OFF Safety Valve/Pilot Kit Assembly
7
7
6. Using burner clamp, screw , and nut provided, assemble clamp to pan (“U” style and triple burners only). This will hold the burner manifold in place.
7. If using optional GA9050A kit, go to Optional GA9050A On/ Off Safety Valve/Pilot Kit section for installation instructions. If using optional GA9150A kit, follow instructions included with kit for installation and operation.
Installation and Gas Connection
1. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward.
2. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.
3. Install adapter fitting onto the burner inlet fitting using thread sealant on male threads of burner inlet fitting (see Figure 7). Adjust to most convenient position.
4. Install the gas connector tube to the gas supply fitting. Care­fully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.
Gas Connector
Burner Pan Assembly (Facing Front of Fireplace)
Figure 7 - Connecting Gas to Appliance
Tube
Adapter Fitting
3. Install the inlet fitting into the inlet opening of the gas control valve (see Figure 10). Use thread sealant on the male pipe threads.
4. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward.
5. Thread the gas supply fitting to the fireplace gas supply pipe. Adjust to most convenient position.
6.
Install the gas connector tube t o the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.
7. Test for leaks following instructions under Testing Burner for Leaks, page 9.
8.
Retighten and adjust the location of the gas control as necessary . The gas control should be level, with the control rod to the front.
Burner Inlet Fitting
Gas Control Valve
Burner Pan Assembly
Figure 8 - Installing Gas Control Valve
Thermocouple and Line
Control Rod
OPTIONAL GA9050A ON/OFF SAFETY VALVE/PILOT KIT ASSEMBLY
For additional convenience and safety, or for propane/LP conver­sion, an optional ON/OFF safety valve/pilot kit is available. See Accessories, page 15.
WARNING: You must use a ON/OFF safety valve/
pilot kit for propane/LP conversion.
Natural Gas Installation
1. Thread the gas control valve onto the burner inlet fitting (see Figure 8). Use thread sealant on the male threads of the burner inlet fitting. Hold the burner inlet fitting with a wrench to pre­vent overtightening the connection to the burner. Make sure the control rod is facing the front (see Figure 8).
2. Attach the pilot gas line to the pilot outlet of the gas control valve and tighten. Connect the thermocouple to the rear of the gas con­trol valve. See Figure 9. Do not overtighten. If using propane/LP gas, see Changing Pilot Orifice, page 8.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Pilot and Line
Gas Control Valve
Figure 9 - Gas Control Valve with Thermocouple and Pilot
Gas Connector Tube
Gas Inlet
Gas Control Valve
Figure 10 - Installing Inlet Fitting and Gas Connector Tube
Inlet Opening
Fitting
Page 8
INSTALLATION
8
Optional GA9050A ON/OFF Safety Valve/Pilot Kit Assembly (Cont.)
INSTALLATION
Continued
9. Install cover to burner pan using screws provided.
10. Install thermocouple, pilot, and ignitor onto valve cover as shown in Figure 11. Use the provided screws.
11. Push the control rod extension onto the “D” shaped control rod through the center hole in the cover.
12. Install the position decal and control knob making sure to align the marks with the correct stop positions of the gas control.
Screw
Ignitor
Valve Cover
Piezo Ignitor
Control Rod Control Knob
Figure 11 - Installing Cover, Control Knob, and Piezo Ignitor
Extension
Thermocouple
Pilot
Propane/LP Gas Conversion
To convert to propane/LP gas, the burner inlet fitting and pilot orifice must be replaced. The propane/LP burner inlet fitting is supplied with the orifice installed for a 24" log set. If you have an 18" or 30" set, you must change this orifice also. See Figure 1, page 3 for product identification.
Burner Inlet Fitting
1. Remove the burner inlet fitting from the burner pan assembly. DO NOT remove the orifice from this fitting. The propane/LP burner inlet fitting is included in the hardware kit (see Figure 12).
2. Be sure to use the correct orifice for your appliance. The hard­ware kit included with this appliance contains two orifices with a cone-like shape. If you have an 18" set, the orifice for the burner inlet fitting is red; for a 30" set, it is black. If you have a 24" log set, the orifice is already installed inside the fitting.
3. For an 18" or 30" set, use a 10mm socket or nut driver to re­move the orifice from the propane/LP burner inlet fitting. Choose the correct orifice for your log set size and install in place of the orifice you just removed.
4. Using thread sealant (resistant to the action of propane/LP gas) on larger end of fitting, screw the burner inlet fitting through hole and into burner manifold (see Figure 13). Tighten using a wrench.
5 . Follow steps 1 through 12 under Natural Gas Installation, pages
7 and 8.
Injector for Natural Gas
NATURAL
GAS FITTING
Figure 12 - Burner Inlet Fittings with Injectors
Figure 13 - Remove Burner Inlet Fitting
Injector for Propane/LP Gas
PROPANE/LP
GAS FITTING
Burner Inlet Fitting for Natural Gas
Changing Pilot Orifice
The pilot is provided with a natural gas orifice installed. For propane/LP gas you must remove it and replace it with an propane/ LP orifice. The accessory hardware kit contains an propane/LP orifice with a red stripe for converting the pilot.
1. Gently loosen and remove the pilot line connection from the bracket (see Figure 14).
2. Replace the injector (see Figure 14) with the propane/LP pilot injector with the red stripe.
3. Replace and tighten the pilot line to the bracket.
4. Continue with step 3 under Natural Gas Installation, pages 7 and 8.
Pilot Injector
Figure 14 - Installing Propane/LP Pilot Orifice
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 9
INSTALLATION
Continued
Testing Burner for Leaks
INSTALLATION
Adding Pan Material
Installing the Grate and Logs
9
9
TESTING BURNER FOR LEAKS
1. Generously apply noncorrosive leak detection fluid to all connections.
WARNING: Never check for gas leaks with
open flame.
2. Light the burner with the shutoff valve no more than half open and holding a match slightly in front of the pan (see Lighting Instructions, page 10).
3. Inspect all connections for bubbles, raw gas odor, or flame from any area other than the burner (leaks). If leaks are de­tected, shut off the gas valve immediately. Tighten, or reas­semble the loose connection(s) using pipe joint compound until burner system is leak free.
4. When the burner is tested and leak free, observe the individual tongues of flame on the burner. cludes more ports on the outside of the bar. Make sure that all ports are clear and producing flame evenly across the burner. If any ports appear blocked, clear them by removing the burner manifold and reaming the ports with a modified paper clip or other suitable tool.
5. When finished testing, turn the gas shutoff valve OFF to extin­guish all flames.
Note:
The burner design in-
ADDING PAN MATERIAL
1. Open the bag of ash bed material (vermiculite) and spread it evenly across the burner pan to the top. You may overflow the front and sides of the pan to cover the entire pan and connect­ing hardware. Do not cover GA9050A or GA9150A valve.
2. Open the glowing embers and evenly cover the ash bed mate­rial (vermiculite) in the burner pan.
3. Place the back log on the grate onto the grate steps (see Figure 16).
4. Place the front log(s) on the grate and slide forward against the front bars on the grate (see Figure 16).
5. Place the smaller top logs onto the bottom logs (see Figure 17). Leave as much open space between logs as possible to mini­mize flame impingement and sooting. they are handled roughly or if hit together while being placed.
Kingston Split Oak Logs
Figure 16 - Installing Front and Back Logs (Number and style of your logs may vary)
Note:
Logs may chip if
Hanover Round Oak Logs
INSTALLING THE GRATE AND LOGS
1. Place the grate over the burner pan where the two outer hori­zontal supports on the grate fit into the two pan positioning notches in the rear vertical edge of the pan.
2. Slide the two rear log grate steps over the two outer horizontal supports on the grate as shown in Figure 15.
Grate Steps
Grate
Figure 15 - Installing Grate (Pan Material Not Shown)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Kingston Split Oak Logs Malibu Drift Logs
Figure 17 - Placement of Top Logs
Page 10
OPERATING APPLIANCE
10
For Your Safety Read Before Lighting Lighting Instructions Gas Shutoff Valve Operation Curing Logs Operating Instructions for GA9050A
OPERATING APPLIANCE
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open when operating unit.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop­erty damage, personal injury or loss of life.
BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’ s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety information, above.
2. Turn the gas shutoff valve to OFF.
3. W ait f ive (5) min utes to clear out any gas. If you then smell
gas STOP! Follow the safety inf ormation above. If you don't smell gas, go on to the next step.
4. Light a match and lay it on top of the pan material about
2" from the end of the supply side of the pan
5. Slowly turn the gas shutoff valve ON until the burner ig-
nites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shutoff v alv e OFF and r epeat steps 1 through 4 again.
CURING
LOGS
During the 2-3 hour appliance break-in period, you may detect an odor from the appliance as the various paints and com­pounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1 hour.
• Burn the logs in consecutive 1 hour periods raising the flame an additional 2" to full flame height for a total of three hours.
OPERATING INSTRUCTIONS
FOR GA9050A
Note:
Operation instructions for GA9150A Remote Ready
Valve/Pilot Kit will be included with the kit.
1. STOP! Read the safety inf ormation, column one this page.
2. Make sure equipment shutoff valve is fully open.
3. Press in and turn control knob clockwise to the
OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas around log set and near floor. If you smell gas, STOP! Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. If you don’t smell gas, go to the next step.
5. T urn control knob counter clockwise to the PILOT
position and press in. Keep control knob pr essed in for f ive (5) seconds.
Note:
You may be running this log set for the first time after hooking up to gas supply . If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.
• If contr ol knob does not pop up when released, contact a
qualified service person or gas supplier for repairs.
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
Adjust the flame ON/OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close, as necessary.
Shutting Off Appliance
Turn gas shutoff valve clockwise to the OFF position.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Control Knob
Pilot
Ignitor
ON
FROM "PILOT" POSITION
SLIGHT PUSH TO
On
PULL PUSH
TURN OFF
PULL PUSH
SLIGHT PUSH TO
FROM "PILOT" POSITION
ON OFF
Figure 18 - Ignitor and Control Knob
TURN OFF
OFF
FROM "PILOT" POSITION
SLIGHT PUSH TO
PULL PUSH
TURN OFF
Off
ON
OFF
901265-01K
Page 11
Operating Instructions for GA9050A (Cont.)
OPERATING APPLIANCE
To Turn Off Gas to Appliance
CLEANING AND MAINTENANCE
SERVICE HINTS
TECHNICAL SERVICE
REPLACEMENT PARTS
11
11
OPERATING APPLIANCE
Continued
6. With contr ol knob pressed in, push down and r elease igni­tor button. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs ar e made, light pilot with match.
7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note:
If pilot goes out, repeat steps 3 through 7, pages 10
and 11.
8. Turn control knob counterclockwise position. Burner should light. If burner does not light, call a qualified service person.
Thermocouple
Pilot Burner
Figure 19 - Thermocouple and Pilot
to the ON
SERVICE HINTS
When Gas Pressure is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low You may feel your gas pressure is too low. If so, contact your local
propane/LP or natural gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s Technical Service Depart­ment at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.
You can also visit DESA’s technical services web site at www.desatech.com.
REPLACEMENT PARTS
Note:
Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Appliance
1. T urn contr ol knob clockwise to the PILOT position.
2. Press in and turn control clockwise to the OFF position.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PILOT position.
CLEANING AND MAINTENANCE
• Keep the area around the log set clean and clear of debris.
• Occasionally, you may use a soft bristle brush to clean logs.
• Once every year a qualified agency or certified chimney sweep
should examine and clean the venting system of the fireplace.
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA’s Technical Service De­partment at 1-866-672-6040. When calling DESA, have ready
• your name and address
• model and serial numbers of your log set
• how log set was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA at 1-866-672-6040 for referral information. When calling DESA, have ready
• model number of your log set
• the replacement part number
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 12
TROUBLESHOOTING
12
TROUBLESHOOTING
WARNING: Turn off log set and let cool before servicing. Only a qualified service person should service and repair log set.
Note:
All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
Log set is smoking/sooting excessively (
Note:
It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where flames contact the logs. This is especially true with propane/LP gas.)
Burner is excessively noisy (
Note:
The movement and combustion of gas will create low, unavoidable levels of noise.)
Burner flame is too low or too high
When ignitor button is pressed, there is no spark at pilot (GA9050A Only)
POSSIBLE CAUSE REMEDY
1. Poor fuel quality
2. Fireplace venting system not drafting properly
3. Excessive flame impingement or blockage
4. Improper fuel/air mixture
5. Excessive gas supply/pressure
1. Passage of air/gas across irregular sur­faces
1. Incorrect gas supply or pressure
2. Blocked burner orifice or burner mani­fold ports
3. Improper burner orifice size
1. Ignitor electrode not connected to igni­tor cable
2. Ignitor cable pinched or wet
3. Bad ground on piezo ignitor
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong
1. Contact local natural or propane/LP gas company
2. Adjust damper wide open and/or have fireplace and venting professionally cleaned and checked
3. Separate the logs to allow more flame passage
4. Remove any foreign items from the flame pattern and/or check for proper orifice sizing
5. Preheat flue in very cold weather
1. Relieve any tight bends or kinks in gas supply line
1. Check for proper gas supply pressure
2. Free burner orifice and manifold ports of any burrs, paint, or other blockage
3. Verify proper burner orifice sizing (see Figure 2, page 4)
1. Reconnect ignitor cable
2. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry
3. Scrape away paint on bracket for better contact with ground on piezo ignitor
4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace electrode
7. Reposition electrode
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 13
TROUBLESHOOTING
Continued
TROUBLESHOOTING
13
13
OBSERVED PROBLEM
When ignitor button is pressed, there is spark at pilot but no ignition (GA9050A Only)
Pilot lights but flame goes out when control knob is released (GA9050A Only)
POSSIBLE CAUSE
1. Gas supply turned off or equipment shutoff valve closed
2. Control knob not in PILOT position
3. Control knob not pressed in while in PILOT position
4. Air in gas lines when installed
5. Pilot adjustment screw closed
6. Pilot is clogged
7. Low gas pressure
1. Control knob not fully pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob­lem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged pilot
5. Thermocouple connection loose at con­trol valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Turn on gas supply or open equipment shutoff valve
2. Turn control knob to PILOT position
3. Press in control knob while in PILOT position
4. Continue holding down control knob. Repeat igniting operation until air is re­moved
5. Adjust pilot flame for approximately 2" blue flame
6. Clean pilot (see Cleaning and Mainte- nance, page 11) or replace pilot assembly
7. Replace gas control
1. Press in control knob fully
2. After pilot lights, keep control knob pressed in 30 seconds
3. Fully open equipment shutoff valve
4. A) Contact local natural gas company B) Clean pilot (see Cleaning and Mainte-
nance, page 11) or replace pilot assembly
5. Hand tighten until snug, then tighten 1/4 turn more
6. Replace thermocouple
7. Replace control valve
Burner does not light after pilot is lit (GA9050A Only)
Delayed ignition burner (GA9050A Only)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Thermocouple leads disconnected or im­properly connected
1. Pilot flame needs adjusting
2. Wrong pilot orifice
1. Clean burner orifice
2. Contact local natural or propane/LP gas company
3. Reconnect leads
1. Adjust pilot flame for approximately 2" blue flame
2. Replace pilot orifice set
Page 14
TROUBLESHOOTING
14
TROUBLESHOOTING
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Log Set produces a clicking/ticking noise just after burner is lit or shut off
Log Set produces unwanted odors
Gas odor even when control knob is in OFF position
Gas odor during combustion
Operating log set where impurities in air exist may create odors.
POSSIBLE CAUSE
1. Metal expanding while heating or con­tracting while cooling
1. Log Set burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See ment above)
2. Gas leak. See Warning statement at
top of page
1. Gas leak. See Warning statement at top of page
2. Control valve defective
1. Gas leak. See Warning statement at
top of page
IMPORTANT
state-
REMEDY
1. This is common with most log sets. If noise is excessive, contact qualified ser­vice person
1. Open flue to maximum. Stop using odor causing products while log set is running
2. Locate and correct all leaks (see Check- ing Gas Connections, page 6)
1. Locate and correct all leaks (see Check- ing Gas Connections, page 6)
2. Replace control valve
2. Locate and correct all leaks (see Check- ing Gas Connections, page 6)
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 15
ACCESSORIES
ACCESSORIES
15
15
Purchase these log set accessories from your local dealer. If they can not supply these accessories, call DESA at 1-866-672-6040 for referral information. You can also write to the address listed on the back page of this manual.
EQUIPMENT SHUTOFF VALVE - GA5010
For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe.
RECEIVER AND HAND-HELD ON/OFF RE­MOTE CONTROL KIT - GHRCB Series
For all models. Allows the gas log set to be turned on and off by using the hand-held remote control. Valve/Pilot Kit GA9150A must be purchased to use this remote.
WALL-MOUNT ON/OFF SWITCH - GWMS2
(Not Shown)
For all models. Allows the gas log set to be turned on and off with a wall switch. Valve/Pilot Kit GA9150A must be purchased to use this remote.
MANUAL CONTROL ON/OFF SAFETY VALVE/ PILOT KIT - GA9050A
(Not Shown)
For all models. Contains components for propane/LP conversion.
REMOTE CONTROL READY ON/OFF SAFETY VALVE/PILOT KIT - GA9150A
(Not Shown)
For all models. Required for remote control operation. Contains components for propane/LP conversion.
INDIVIDUAL ROUND LOG - GA9450A
(Not Shown)
For decorative purposes only. Not to be used as additional logs on unit.
INDIVIDUAL SPLIT LOG - GA9550A
(Not Shown)
For decorative purposes only. Not to be used as additional logs on unit.
PINE CONES - GA9650A
(Not Shown)
For all models. Use for additional decoration only. (3 pine cones per box).
ASH BED MATERIAL (Vermiculite) - GA9750A
(Not Shown)
For all models. Use for firebox decoration only.
GLOWING EMBERS - GA9950A
(Not Shown)
For all models. Use for firebox decoration only.
SILICA SAND - GA9850A
(Not Shown)
For all models. Use for firebox decoration only.
LAVA ROCK - GA6067A
(Not Shown)
For all models. Use for firebox decoration only.
DECORATIVE ASH BED CONTROL COVER CDABKA (Not Shown)
An attractive way to cover control knob and piezo ignitor.
18" ORNAMENTAL GRATE ENHANCER GA9350A (Not Shown)
For 18" models only. Additional decoration for front grate.
24" ORNAMENTAL GRATE ENHANCER GA9360A (Not Shown)
For 24" models only. Additional decoration for front grate.
30" ORNAMENTAL GRATE ENHANCER GA9370A (Not Shown)
For 30" models only. Additional decoration for front grate.
FIRE CRACKLE - CF6-A
(Not Shown)
For all models. Creates the sound of a real burning fire.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 16
ILLUSTRATED PARTS BREAKDOWN
16
Models VVSR18, FVSR18, VVSR24, FVSR24, VVDR18, FVDR18, VVDR24, FVDR24, VVDR30 and FVDR30
ILLUSTRATED PARTS BREAKDOWN
BURNER MODELS VVSR18, FVSR18, VVSR24, FVSR24, VVDR18, FVDR18, VVDR24, FVDR24, VVDR30 AND FVDR30
9
9
10
7
12
5
11
5
1
6
8
4
3
For more information, visit www.desatech.com
For more information, visit www.desatech.com
2
13
901265-01K
Page 17
PARTS LIST
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY VVSR18 VVSR24 VVDR18 VVDR24 VVDR30 NO. FVSR18 FVSR24 FVDR18 FVDR24 FVDR30 DESCRIPTION QTY.
1 901063-01 901063-01 901063-01 901063-01 901063-01 Brass 3/8 FLR x 1/2 FPT Elbow 1 2 901057-01 901057-01 901057-01 901057-01 901057-01 Brass 3/8 FLR x 3/8 FPT Elbow 1 3 901066-01 901066-01 901066-01 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-02 901064-03 901064-02 901064-03 901064-04 Natural Gas Injector 1 5 901208-01 901208-02 901207-01 901207-02 901207-03 Burner Manifold 1 6 901136-01 901136-02 901137-01 901137-02 901137-03 Burner Pan 1 7 901242-01 901242-01 901242-01 901242-01 901242-01 Damper Clamp - Std. Assembly 1 8 901232-01 901232-01 901232-01 901232-01 901232-01 Gas Line - 12" Aluminum 1 9 901430-01 901430-01 901431-01 901431-01 901431-01 Grate Steps 2 10 901243-01 901243-02 901246-01 901246-02 901246-03 Log Grate 1 11 901681-01 901681-01 901681-01 Burner Strap 1 12 901078-01 901078-01 901078-01 Nut #8/32 1 13 901076-01 901076-01 901076-01 Screw #8/32 x 3/8 1
PARTS AVAILABLE NOT SHOWN
901156-01 901156-01 901156-01 901156-01 901156-01 .125# Bag Embers 1 901155-01 901155-01 901155-01 901155-01 901155-01 1.5# Bag Ash Bed Material
Models VVSR18, FVSR18, VVSR24, FVSR24, VVDR18,
PARTS LIST
FVDR18, VVDR24, FVDR24, VVDR30 and FVDR30
(Vermiculite) 1
17
17
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 18
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST
18
Models VSLR18, VSLR24, VDLCR18, VDLCR24 and VDLCR30
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST
LOG SET MODELS VSLR18, VSLR24, VDLCR18, VDLCR24 AND VDLCR30
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
15
8
11
7
12
14
10
Hanover Round Oak Logs
KEY PART NUMBER NO. VSLR18 VSLR24 VDLCR18 VDLCR24 VDLCR30 DESCRIPTION QTY.
1 901565-02 901566-02 901567-02 Bottom Rear 1 2 901603-01 901604-01 901604-04 Bottom Front 1 3 901593-01 901594-01 901595-01 Bottom Front 1 4 901580-02 VR-11\VC Top Log 1 5 901588-01 901588-01 901588-01 VS-12 Top Log 1 6 901592-01 901592-01 VCR-12 Top Log 1 7 901591-02 901591-02 901591-02 VCR-11\VC Top Log 1 8 901551-03 901551-03 901551-03 CHR-13\VC Top Log 1 9 901587-01 901587-01 901587-01 VCR-9 Top Log 1 10 901625-03 901626-03 Bottom Rear 1 11 901583-01 901584-01 Bottom Front 1 12 901541-02 901541-02 CPR-13\VR Top Log 1 13 901580-01 901580-01 VR-11\VR Top Log 1 14 901579-01 901579-01 VR-10Y Top Log 1 15 901578-01 VR-10 Top Log 1
13
4
1
3
2
Kingston Split Oak Logs
6
5
9
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 19
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST
Models FSLR18, FSLR24, FDLCR18, FDLCR24 and FDLCR30
ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST
LOG SET MODELS FSLR18, FSLR24, FDLCR18, FDLCR24 AND FDLCR30
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
15
19
19
8
7
6
11
12
4
14
10
13
KEY PART NUMBER NO. FSLR18 FSLR24 FDLCR18 FDLCR24 FDLCR30 DESCRIPTION QTY.
1 901565-03 901566-03 901567-03 Bottom Rear Log 1 2 901656-01 901657-01 901658-01 Bottom Front Log 1 3 901666-01 901667-01 901668-01 Bottom Front Log 1 4 901619-01 901619-01 901619-01 FS-12Y Top Log 1 5 901617-01 901617-01 901617-01 FS-16 Top Log 1 6 901612-01 901612-01 901612-01 FS-17 Top Log 1 7 901620-02 901620-02 901620-02 FR12L Top Log 1 8 901614-01 901614-01 FS15 Top Log 1 9 901623-02 FR14 Top Log 1 10 901625-01 901626-01 Bottom Rear Log 1 11 901635-01 901636-01 Bottom Front Log 1 12 901620-01 901620-01 FR12L Top Log 1 13 901622-01 901622-01 FR11 Top Log 1 14 901547-01 CPR11 Top Log 1 15 901623-01 901623-01 FR14 Top Log 1
3
1
2
Manchester Split Oak LogsArlington Round Oak Logs
5
9
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 20
20
ILLUSTRATED PARTS BREAKDOWN
Models CVSR18, CVSR24, CPVSR18 and CPVSR24
ILLUSTRATED PARTS BREAKDOWN
MODELS CVSR18, CVSR24, CPVSR18 AND CPVSR24
10
15
14
16
13
12
11
9
Oxford Round Oak Logs
9
23
22
21
20
18
19
7
5
17
1
6
8
4
3
2
Amherst Round Oak Logs
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 21
PARTS LIST
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. CVSR18 CVSR24 CPVSR18 CPVSR24 DESCRIPTION QTY.
1 901058-01 901058-01 901058-01 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 901059-01 901059-01 901059-01 Brass 3/8 FLR x 3/8 FPT Adapter 1 3 901066-01 901066-01 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-02 901064-03 901064-02 901064-03 Natural Gas Injector 1 5 901208-01 901208-02 901208-01 901208-02 Burner Manifold 1 6 901136-01 901136-02 901137-01 901137-02 Burner Pan 1 7 901242-01 901242-01 901242-01 901242-01 Damper Clamp - Std. Assembly 1 8 101628-01 101628-01 101628-01 101628-01 Gas Line - 10" Flex 1 9 901431-01 901431-01 Grate Steps 2 10 901243-01 901243-02 901246-01 901246-02 Log Grate 1 11 901635-01 901636-01 Bottom Front Log 1 12 901625-01 901626-01 Bottom Rear Log 1 13 901545-01 901545-01 CPR12/CP Top Log 1 14 901546-01 CPR13S/CP Top Log 1 15 901541-01 901541-01 CPR13/CP Top Log 1 16 901547-01 901547-01 CPR14/CP Top Log 1 17 901641-01 901642-01 Bottom Front Log 1 18 901625-02 901626-02 Bottom Rear Log 1 19 901580-04 VR11/CH Top Log 1 20 901555-01 901555-01 CHR10/CH Top Log 1 21 901550-01 901550-01 CHR11/CH Top Log 1 22 901551-01 901551-01 CHR13/CH Top Log 1 23 901556-01 901556-01 CHR13Y/CH Top Log 1
Models CVSR18, CVSR24, CPVSR18 and CPVSR24
PARTS LIST
21
21
901156-01 901156-01 901156-01 901156-01 .125# Bag Embers 1 901155-01 901155-01 901155-01 901155-01 1.5# Bag Ash Bed Material
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
PARTS AVAILABLE NOT SHOWN
(Vermiculite) 1
Page 22
22
ILLUSTRATED PARTS BREAKDOWN
Models CVDR18, CVDR24, CVDR30, LVDR18, LVDR24 and LVDR30
ILLUSTRATED PARTS BREAKDOWN
MODELS CVDR18, CVDR24, CVDR30, LVDR18, LVDR24 AND LVDR30
9
10
15d
15b
Berkshire Oak Log Set
9
15e
15f
15a
15c
14b
14a
14a
17a
7
17f
12
11
5
16b
1
6
8
4
3
13
2
17e
Coventry Oak Log Set
17b
17c
17d
16a
16b
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 23
Models CVDR18, CVDR24, CVDR30, LVDR18, LVDR24 and LVDR30
PARTS LIST
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. CVDR18 CVDR24 CVDR30 LVDR18 LVDR24 LVDR30 DESCRIPTION QTY.
1 901058-01 901058-01 901058-01 901058-01 901058-01 901058-01 Brass 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 901059-01 901059-01 901059-01 901059-01 901059-01 Brass 3/8 FLR x 3/8 FPT Adapter 1 3 901066-01 901066-01 901066-01 901066-01 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-02 901064-03 901064-04 901064-02 901064-03 901064-04 Natural Gas Injector 1 5 901207-01 901207-02 901207-03 901207-01 901207-02 901207-03 Burner Manifold 1 6 901137-01 901137-02 901137-03 901137-01 901137-02 901137-03 Burner Pan 1 7 901242-01 901242-01 901242-01 901242-01 901242-01 901242-01 Damper Clamp - Std. Assembly 1 8 101628-01 101628-01 101628-01 101628-01 101628-01 101628-01 Gas Line - 10" Flex 1 9 901431-01 901431-01 901431-01 901431-01 901431-01 901431-01 Grate Steps 2 10 901246-01 901246-02 901246-03 901246-01 901246-02 901246-03 Log Grate 1 11 901681-01 901681-01 901681-01 901681-01 901681-01 901681-01 Burner Strap 1 12 901078-01 901078-01 901078-01 901078-01 901078-01 901078-01 Nut #8/32 1 13 901076-01 901076-01 901076-01 901076-01 901076-01 901076-01 Screw #8/32 x 3/8 1 14 901437-01 901437-03 901437-05 — Berkshire Oak Bottom Log Set - 3 Pieces 1 14a 901461-01 901461-02 901461-03 — Front Bottom Split (2 Pieces) 1 14b 901111-01 901111-02 901111-03 — Back Bottom Round 1 15 901440-01 901440-02 901440-03 — Berkshire Oak Top Log Set 1
(18"-4 Pc. Set, 24"-5 Pc. Set, 30"-6 Pc. Set) 15a 901089-01 901089-01 901090-01 — Top Split Log 1 15b 901094-01 901094-01 901095-01 — Top Round Log 1 15c 901101-01 901101-01 — Top Round Log 1 15d 901106-01 — Top Split Log 1 15e 901118-01 901118-01 901107-01 — Top Round Log 1 15f 901120-01 901120-01 901120-01 — Top Round Log 1 16 901897-01 901897-02 901897-01 Coventry Oak Bottom Log Set - 3 Pieces 1 16a 901111-01 901111-02 901111-03 Back Bottom Log 1 16b 901463-01 901463-02 901463-01 Front Bottom Split (2 Pieces) 1 17 901898-01 901898-02 901898-03 Coventry Oak Top Log Set 1
(18"-4 Pc. Set, 24"-5 Pc. Set, 30"-6 Pc. Set) 17a 901089-01 901089-01 901089-01 12" Top Split Log 1 17b 901100-01 901100-01 11" Top Round Log 1 17c 901103-01 901103-01 901103-01 13" Top Round "Y" Log 1 17d 901118-01 9" Top Round Log 1 17e 901120-01 901120-01 901120-01 11" Top Round Log 1 17f 901476-01 901476-01 901476-01 13" Top Split "Y" Log 1
PARTS AVAILABLE — NOT SHOWN
901156-01 901156-01 901156-01 901156-01 901156-01 901156-01 .125# Bag Embers 1
PARTS LIST
901155-01 901155-01 901155-01 901155-01 901155-01 901155-01 1.5# Bag
Ash Bed Material (Vermiculite) 1
23
23
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 24
24
ILLUSTRATED PARTS BREAKDOWN
Models LBFL18, LBFL24, BFLT18 and BFLT24
ILLUSTRATED PARTS BREAKDOWN
MODELS LBFL18, LBFL24, BFLT18 AND BFLT24
24
14
15
23
14
25
27
Shenandoah
Green Mountain Oak Log Set
19
21
28
26
22
13
11
12
6
7
5
1
9
8
4
3
2
18
17
Mendocino Oak Log Set
20
16
10
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 25
PARTS LIST
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. BFLT18 BFLT24 LBFL18 LBFL24 DESCRIPTION QTY.
1 901058-01 901058-01 901058-01 901058-01 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 901059-01 901059-01 901059-01 3/8 FLR x 3/8 FPT Adapter 1 3 901066-01 901066-01 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-03 901064-04 901064-03 901064-04 Natural Gas Injector 1 5 110331-01 110331-01 110331-01 110331-01 1/2 MPT x 3/8 Compression Fitting 1 6 110332-01 110332-02 110332-01 110332-02 Burner Manifold 1 7 110325-01 110325-02 110325-01 110325-02 Front Burner 1 8 901232-01 901232-01 901232-01 901232-01 Gas Line - 12" Flex 1 9 110367-01 110367-02 110367-01 110367-02 Burner Pan 1 10 901076-01 901076-01 901076-01 901076-01 Screw #8/32 x 3/8" 1 11 901078-01 901078-01 901078-01 901078-01 Nut #8/32 1 12 901681-01 901681-01 901681-01 901681-01 Burner Strap 1 13 901242-01 901242-01 901242-01 901242-01 Damper Clamp - Std. Assy 1 14 901431-01 901431-01 901431-01 901431-01 Grate Steps 2 15 901246-01 901246-02 901246-01 901246-02 Log Grate 1 16 110300-01 110303-01 Rear Log - Mendocino Oak 1 17 110299-01 110302-01 Front Right Split Log - Mendocino Oak 1 18 110298-01 110301-01 Front Left Split Log - Mendocino Oak 1 19 110292-01 110292-01 Left Top Log - Mendocino Oak 1 20 110293-01 110293-01 Right Top Log - Mendocino Oak 1 21 110295-01 110295-01 Left Center Top Log - Mendocino Oak 1 22 110294-01 110294-01 Right Center Top Log - Mendocino Oak 1 23 110305-01 110296-01 Rear Log - Shenandoah Oak 1 24 110304-01 110297-01 Front Log - Shenandoah Oak 1 25 110292-01 110292-01 Left Top Log - Shenandoah Oak 1 26 110293-01 110293-01 Right Top Log - Shenandoah Oak 1 27 110295-01 110295-01 Left Center Top Log - Shenandoah Oak 1 28 110294-01 110294-01 Right Center Top Log - Shenandoah Oak 1
PARTS LIST
Models LBFL18, LBFL24, BFLT18 and BFLT24
25
25
901156-01 901156-01 901156-01 901156-01 .125# Bag Embers 1 901155-01 901155-01 901155-01 901155-01 1.5# Bag
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
PARTS AVAILABLE — NOT SHOWN
Ash Bed Material (Vermiculite) 1
Page 26
ILLUSTRATED PARTS BREAKDOWN
26
Models MD18 AND MD24
ILLUSTRATED PARTS BREAKDOWN
MODELS MD18 AND MD24
Malibu Drift Log Set
15a
15b
14c
15d
15c
14a
14b
9
9
10
7
12
11
5
For more information, visit www.desatech.com
For more information, visit www.desatech.com
13
1
6
8
4
3
2
901265-01K
Page 27
PARTS LIST
This list contains replaceable parts used in your log set. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. MD18 MD24 DESCRIPTION QTY.
1 901058-01 901058-01 3/8 FLR x 1/2 FPT Adapter 1 2 901059-01 901059-01 3/8 FLR x 3/8 FPT Adapter 1 3 901066-01 901066-01 Brass Air Mixer - Natural Gas 1 4 901064-03 901064-04 Natural Gas Injector 1 5 901207-01 901207-01 Burner Manifold 1 6 901137-01 901137-02 Burner Pan 1 7 901242-01 901242-01 Damper Clamp - Std. Assy 1 8 101628-01 101628-01 Gas Line - 10" Flex 1 9 901431-01 901431-01 Grate Steps 2 10 901246-01 901246-02 Log Grate 1 11 901681-01 901681-01 Burner Strap 1 12 901078-01 9010787-01 Nut #8/32 1 13 901076-01 901076-01 Screw #8/32 x 3/8 1 14 111857-01 111857-02 Malibu Drift Bottom Log Set - 3 Pieces 1 14a 111843-01 111844-01 Front Bottom Left Log (Split Log) 1 14b 111843-02 111844-02 Front Bottom Right Log (Split Log) 1 14c 111843-03 111844-03 Rear Bottom Round Log 1 15 111858-01 111858-02 Malibu Drift Top Log Set - 4 Pieces 1 15a 111845-01 111845-01 Top Left Log 1 15b 111845-02 111845-02 Top Right Center Log 1 15c 111845-03 111845-03 Top Left Center Log 1 15d 111845-04 111845-04 Top Right Y Log 1
PARTS AVAILABLE — NOT SHOWN
901156-01 901156-01 .125# Bag Embers 1 901155-01 901155-01 1.5# Bag Ash Bed Material (Vermiculite) 1
PARTS LIST
Models MD18 AND MD24
27
27
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 28
28
NOTES
NOTES
_______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 29
OWNER'S REGISTRATION FORM
In order to provide better customer service for this and future purchases, we recommend that you register your product with us. You can register online at www.desatech.com. If access to our website is not available to you, please complete this Owner’s Registration Form and mail to the address on the back of this owners manual. Please provide the following product information:
Brand: Model: Date Purchased: Serial Number: First Name: Last Name: Address: City: State: Zip: Country: Home Phone: ( ) - E-Mail:
Please answer the following questions to register your product with DESA:
1. Where will the product be used? Living/Family Room Office/Warehouse Utility Shed/Outbuilding Garage Bedroom Bathroom Other
2. If you bought this product yourself, did you plan to purchase this type of product before going into the store? Yes No
3. Who selected the product? Male Female Both
4. What is the population of your area? Under 10,000 10,000 to 25,000 25,000 to 50,000 50,000 to 100,000 100,000 to 250,000 Over 250,000
5. What is your primary source of heat? Propane (LP Gas) ❍ Fuel Oil ❍ Wood Natural Gas Electric Other
6. How was the product installed? Professional Installer Self Other
7. Cost of product excluding sales tax? $___________________
8. Cost to install product? $____________________
9. Type of store where product was purchased? Hardware Propane Dealer Natural Gas/Utility Co. Home Center/Builders Supply Fireplace or Hearth Shop Farm Store Other
10. What motivated you to buy this product? Sudden Cold Weather Replace Older Model D.I.Y. Home Project Emergency Back-Up Heat Heater was on Sale Energy Savings/High Efficiency Construction Project Other
11. How did you learn about this product brand? Advertising Relative or Friend Store Display Other ________________________
12. Level of Education of Purchaser: Some High School Completed High School Completed College Completed Graduate School
13. Age of Purchaser: Under 20 20 - 29 30 - 39 40 - 49 50 - 59 60 or Over
14. Buyers total annual household income: Under $15,000 $15,000 to $19,999 $20,000 to $34,999 $35,000 to $49,999 $50,000 to $74,999 $75,000 to $99,999 $100,000 and Over
15. Store where product was purchased: Name: ______________________________________ City: _______________________ State: __________
16. In choosing this product, how important were the following:
Availability Price Brand Name Overall Quality Heat Output Made in USA Warranty Local Service Value for Price Prior Brand Experience Controls Location Thermostat, Remote, or Manual Operation Ease of Operation Special Features Salespersons Recommendation Friend/Relatives Recommendation Portability
901265-01K
Quiet Operation
For more information, visit www.desatech.com
For more information, visit www.desatech.com
(Comfort Glow, Vanguard, etc.) (EFP33PR, VTGH33NR, etc.)
Note:
Keep receipt for warranty verification.
7 or 9 digit number located on product or identification tag.
Not Important Somewhat Important Very Important
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍
29
29
Page 30
30
TAPE
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
Postage
Required
For more information, visit www.desatech.com
For more information, visit www.desatech.com
TAPE
901265-01K
Page 31
NOTES
NOTES
_______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________
31
31
_______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265-01K
Page 32
32
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make
no other warranty, expressed or implied.
LIMITED WARRANTY - VENTED GAS LOGS
DESA warrants this product to be free from defects on burner system for four (4) years and logs for a lifetime from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this log set to proper operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or DESA who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The log set MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective log set will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON BURNER SYSTEM AND A LIFETIME ON LOGS FROM THE DATE OF FIRST PURCHASE; AND DESA’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004
www.desatech.com
For more information, visit www.desatech.com
For more information, visit www.desatech.com
901265 01
NOT A UPC
901265-01 Rev. K 03/04
901265-01K
Loading...