WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
Save this manual for future reference.
For more information, visit www.desatech.com
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation
and operational procedures. For assistance or additional information consult a qualified installer, service
agency, or the gas supplier.
WARNING: This appliance is for installation only in a
solid-fuel burning masonry or UL127 factory-built fireplace, or in an listed ventless firebox enclosure. It is design-certified for these installations in accordance with
ANSI Z21.11.2. Exception: Do not install this appliance
in a factory-built fireplace that includes instructions
stating it has not been tested or should not be used
with unvented gas logs. For unmarked factory-built
fireplaces, contact fireplace manufacturer if unsure of
this application.
WARNING: This is an unvented gas-fired heater. It uses
air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must
be provided. Refer to Air for Combustion and Ventilation
section on page 5 of this manual.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Safety Information ............................................... 3
Local Codes ........................................................ 4
Illustrated Parts Breakdown and Parts List ....... 26
Warranty Information ...........................Back Cover
18
www.desatech.com
113183-01B
20
.. 24
SAFETY INFORMATION
WARNING: This product
contains and/or generate s
chemicals known to the State
of California to cause cancer or
birth defects, or other reproductive harm.
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate, or service this heater.
Improper use of this heater can
cause property damage and
serious injury or death from
burns, fire, explosion, electrical
shock, and carbon monoxide
poisoning.
WARNING: This appliance
is for installation only in a
solid-fuel burning fireplace or
approved ventless firebox enclosure.
WARNING: Do not allow fans
to blow directly into the fireplace.
Avoid any drafts that alter burner
flame patterns. Ceiling fans can
create drafts that alter burner
flame patterns. Altered burner
patterns can cause sooting.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the flu, with
headaches, dizziness, or nausea. If you have these
signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some
people are more affected by carbon monoxide
than others. These include pregnant women,
people with heart or lung disease or anemia, those
under the influence of alcohol, and those at high
altitudes.
Natural and Propane/LP Gas: Natural and pro-
pane/LP gases are odorless. An odor-making agent
is added to the gas. The odor helps you detect a gas
leak. However, the odor added to the gas can fade.
Gas may be present even though no odor exists.
Make certain you read and understand all warn
ings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not use a
blower insert, heat exchanger
insert, or other accessory not ap
-
proved for use with this heater.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the heater.
Heater base assembly becomes
very hot when running heater.
Keep children and adults away
from hot surface to avoid burns
or clothing ignition. Heater
will remain hot for a time after
shutdown. Allow surface to cool
before touching.
Carefully supervise young children when they are in the room
-
with heater.
You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
Keep the appliance area clear
and free from combustible materials, gasoline, and other flammable vapors and liquids.
www.desatech.com
3113183-01B
SAFETY INFORMATION
Continued
1.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply
tank(s) outdoors.
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighborʼs phone. Follow the gas supplierʼs
instructions
• if you cannot reach your gas supplier, call
the fire department
4.
This heater shall not be installed in a bedroom or
bathroom, unless installed as a vented appliance.
5.
Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint
by a qualified chimney cleaner. Creosote will
ignite if highly heated. A dirty chimney flue
may create and distribute soot within the house.
Inspect chimney flue and firebox for damage. If
damaged, repair flue before operating heater.
6. Do not burn solid-fuel in a masonry or UL127
factory-built fireplace in which a vent-free
room heater is installed.
7.
If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside
fireplace will cause glass to burst. Make sure there
are no obstructions across openings of fireplace.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance
page 19.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls and furniture.
10. This heater needs fresh, outside air ventilation to
run properly. This heater has an Oxygen Deple
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the heater if enough fresh air
is not available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting off,
see Troubleshooting, page 20.
11. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
12. Do not use this heater to cook food or burn
paper or any other type of solid fuels.
13. Do not use heater if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the room heater
and to replace any part of the control system and
any gas control which has been under water.
14. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dimesized or larger).
15. Turn heater off and let cool before servicing,
installing, or repairing.Only a qualified ser
vice person should install, service, or repair
heater.
16. Operating heater above elevations of 4,500
feet may cause pilot outage.
17. To prevent performance problems with pro
pane/LP models, do not use propane/LP fuel
tank of less than 100 lb. capacity.
18. Prov ide adeq ua te clearan ce s around air
openings.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
,
Note: Where listed vented decorative logs are
required, thermostat operation is not permitted.
State of Massachusetts: The installa
tion must be made by a licensed plumber
or gas fitt er in the Common we alth of
Massachusetts.
Sel lers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
.
1430 Broadway
New York, NY 10018
Batterymarch Park
Quincy, MA 02269
-
-
-
-
4
www.desatech.com
113183-01B
PRODUCT
IDENTIFICATION
Ignitor
Log Set
SAFETY DEVICE
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot shuts off the heater if there
is not enough fresh air.
IGNITION SYSTEM
This heater has an electronic ignitor to light heater
fuel supply.
AIR FOR COMBUSTION
AND VENTILATION
Burner
Control Knob
Grate
Figure 1 - Product Identification
Base
Assembly
UNPACKING
CAUTION: Do not remove the
data plates from the base assembly. The data plates contain
important warranty and safety
information.
1. Remove logs and heater base assembly from
carton. Note: Do not pick up heater base assembly by burners. This could damage heater.
Always handle base assembly by the sides of
assembly.
2. Remove all protective packaging applied to
logs and heater for shipment.
3. Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought heater.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside
venting. There is no heat loss out a vent or up a
chimney. Heat is generated by both realistic flames
and glowing coals. This heater is designed for ventfree operation with flue damper closed. It has been
tested and approved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in some
areas prohibit the use of vent-free heaters.
www.desatech.com
WARNING: This heater shall
not be installed in a confined
space or unusually tight construction unless provisions are provided for adequate combustion and
ventilation air. Read the following
instructions to insure proper fresh
air for this and other fuel-burning
appliances in your home.
Todayʼs homes are built more energy efficient
than ever. New materials, increased insulation and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy effi
cient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,
Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 5 through 7 will help
you classify your space and provide adequate
ventilation.
-
-
5113183-01B
AIR FOR COMBUSTION
AND VENTILATION
Continued
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
Unusually tight construction is defined as
construction where:
a. walls and ceilings exposed to the out
side atmosphere have a continuous
water vapor retarder with a rating of
one perm (6 x 10
less with openings gasketed or sealed
and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window
and door frames, between sole plates
and floors, between wall-ceiling joints,
between wall panels, at penetrations
for plumbing, electrical and gas lines
and at other openings.
If your home meets all of these three cri
teria, you must provide additional fresh
air. See Ventilation Air From Outdoors,
page 7.
If your home does not meet all of the three
criteria above, proceed to Determining Fresh-Air Flow For Heater Location.
Confined and Unconfined Space
The National Fuel Gas Code, ANSI Z223.1/NFPA 54
defines a confined space as a space whose volume
is less than 50 cubic feet per 1,000 Btu per hour
3
(4.8 m
per kw) of the aggregate input rating of all
appliances installed in that space and an unconfined
space as a space whose volume is not less than 50
cubic feet per 1,000 Btu/Hr (4.8 m3 per kw) of the
aggregate input rating of all appliances installed in
that space. Rooms communicating directly with the
space in which the appliances are installed*, through
openings not furnished with doors, are considered
a part of the unconfined space.
* Adjoining rooms are communicating only if
there are doorless passageways or ventilation grills
between them.
6
-11
kg per pa-sec-m2) or
www.desatech.com
DETERMINING FRESH-AIR FLOW
FOR HEATER LOCATION
Determining if You Have a Confined or
Unconfined Space
Use this work sheet to determine if you have a
confined or unconfined space.
Space: Includes the room in which you will install
heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x
width x height).
Length x Width x Height =__________cu. ft.
-
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2560 cu. ft.
(volume of space)
If additional ventilation to adjoining room is
supplied with grills or openings, add the volume
of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine
the maximum Btu/Hr the space can support.
__________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2560 cu. ft. (volume of space) x 20 =
51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in
the space.
Vent-free heater ___________
-
Gas water heater* ___________
Gas furnace ___________
Vented gas heater ___________
Gas fireplace logs ___________
Gas water heater __________
Other gas appliances* + __________
Total = __________
* Do not include direct-vent gas appliances. Di
rect-vent draws combustion air from the outdoors
and vents to the outdoors.
Example:
Gas water heater __________
Vent-free heater + __________
Total = __________
4. Compare the maximum Btu/Hr the space can
support with the actual amount of Btu/Hr used.
_________
_________
Example: 51,200 Btu/Hr (maximum the space
79,000 Btu/Hr (actual amount of
The space in the above example is a confined space
because the actual Btu/Hr used is more than the maxi
mum Btu/Hr the space can support. You must provide
additional fresh air. Your options are as follows:
Btu/Hr (maximum the space can support)
Btu/Hr (actual amount of Btu/Hr used)
can support)
Btu/Hr used)
40,000
39,000
79,000
113183-01B
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
Btu/Hr
-
Btu/Hr
Btu/Hr
Btu/Hr
-
AIR FOR COMBUSTION
Outlet
Air
Ventilated
Attic
Outlet
A
ir
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills
Into Adjoining Room,
Option
2
Ve
ntilation
Grills
Into Adjoining
Room,
Option 1
12"
12"
AND VENTILATION
Continued
A. Rework worksheet, adding the space of an adjoin-
ing room. If the extra space provides an unconfined
space, remove door to adjoining room or add
ventilation grills between rooms. See Ventilation
Air From Inside Building.
B. Vent room directly to the outdoors. See Ventila
tion Air From Outdoors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr size
makes room unconfined.
If the actual Btu/Hr used is less than the maximum
Btu/Hr the space can support,
confined space. You will need no additional fresh
air ventilation.
WARNING: If the area in which
the heater may be operated is
smaller than that defined as
an unconfined space or if the
building is of unusually tight
construction, provide adequate
combustion and ventilation air
by one of the methods described
in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 Section 5.3
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining
unconfined space, you must provide two permanent openings: one within 12" of the ceiling and
one within 12" of the floor on the wall connecting
the two spaces (see options 1 and 2, Figure 2). You
can also remove door into adjoining room (see
option 3, Figure 2). Follow the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for
Combustion and Ventilation for required size of
ventilation grills or ducts.
the space is an un-
-
Figure 2 - Ventilation Air from Inside
Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or
ducts. You must provide two permanent openings:
one within 12" of the ceiling and one within 12"
of the floor. Connect these items directly to the
outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces. Follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
Section 5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet
or outlet air into attic if attic has a thermostatcontrolled power vent. Heated air entering the attic
will activate the power vent.
Figure 3 - Ventila tion Air from Outdoors
www.desatech.com
7113183-01B
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: Installation and
repair should be done by a
qualified service person. The
appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning
may be required due to excessive lint from carpeting, bedding
material, etc. It is imperative that
control compartments, burners
and circulating air passageways
of the appliance be kept clean.
WARNING: Before installing
in a solid fuel burning fireplace,
the chimney flue and firebox
must be cleaned of soot, creosote, ashes and loose paint by a
qualified chimney cleaner. Creo
sote will ignite if highly heated. A
dirty chimney flue may create and
distribute soot within the house.
Inspect chimney flue and firebox
for damage. If damaged, repair
flue before operating heater.
WARNING: Seal any fresh
air vents or ash clean-out doors
located on floor or wall of fireplace. If not, drafting may cause
pilot outage or sooting. Use a
heat-resistant sealant. Do not
seal chimney flue damper.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the firebox opening
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next
to heater. Installing heater next
to vinyl or cloth wall coverings or
operating heater where impurities
(such as, but not limited to, tobacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to
the air. Although this is beneficial, installing heater
in rooms without enough ventilation air may cause
-
mildew to form from too much moisture. See Air
for Combustion and Ventilation
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP)
for your unit. If your gas supply is not correct, do
not install fireplace. Call dealer where you bought
fireplace for proper type fireplace.
, page 5.
WARNING: This appliance
is equipped for (natural or propane/LP) gas. Field conversion
is not permitted.
8
www.desatech.com
113183-01B
INSTALLATION
Continued
INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION
WARNING: Maintain the minimum clearances. If possible, provide greater clearances from floor,
ceiling, and adjoining wall.
LOG SIZING REQUIREMENTS
Log Minimum Firebox
Size Height Depth Front Rear *
Width Width
24" 17" 14" 28" 20 1/4"
Minimum Firebox with Blower
24" 17" 14" 34" 22 3/8"
* Measured at 14" depth.
Carefully follow the instructions below. This will
ensure safe installation into a masonry, UL127-listed
manufactured fireplace, or listed vent-free firebox.
Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and wall
should follow diagram in Figure 4.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the
fireplace cabinet (see Figure 4).
Note: When installing your gas logs into
a man uf actur ed fireb ox , foll ow fir ebox
manufacturerʼs instructions for minimum
clearances to combustible materials.
B. Clearances from the top of the fireplace opening
to the ceiling should not be less than 42 inches.
Example
Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note: If using a mantel proceed to If Using Mantel.
If not using a mantel, follow the information on
this page.
You must have noncombustible material(s) above the
fireplace opening. Noncombustible materials (such as
slate, marble, tile, etc.) must be at least 1/2 inch thick.
With sheet metal, you must have noncombustible
material behind it. Noncombustible material must
extend at least 8" up. If noncombustible material is
less than 12", you must install the fireplace hood ac
cessory. See Figure 5 for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2 inch thick. With sheet metal, you must have
noncombustible material behind it. Noncombus
tible material must extend at least 8 inches up.
If noncombustible material is less than 12", you
must install the fireplace hood accessory. Even if
noncombustible material is more than 12", you may
need the hood accessory to deflect heat away from
your mantel shelf. See Figure 5 and Figures 6 and
7, page 10, for minimum clearances.
IMPORTANT: If you cannot meet these minimum
clearances, you must operate heater with chimney
flue damper open.
Noncombustible Requirements for
Material Distance (A)
12" or more Noncombustible material
okay.
Between 8" Install fireplace hood
and 12" accessory (GA6050,
GA6052, or GA6053 see
Accessories, page 25).
Less than 8" Noncombustible material
must be extended to at
least 8". See Between 8"
and 12"
cannot extend material,
you must operate heater
with flue damper open.
Safe Installation
, above. If you
-
-
*Minimum 16 inches from Side Wall
Figure 4 - Minimum Clearance for
Combustible to Wall
*
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
www.desatech.com
9113183-01B