Installing the transmitter
*2703292_Rev.2en*
TYBOX 137 - 237 - 337
TYBOX 337
2 x 1,5V LR03 - AAA Alkaline
230V~, 50 Hz +/- 10%
0,5 VA
Lithium 3,6 V - 2,6Ah
(10 years autonomy)
R6 / AA
868 MHz (EN 300 220)
100 m
8 max.
/ 5 A max., 230V~ (Type 1.C) /
°C -5°C / +40°C -10°C / +70°C
80 x 103 x 25 mm 54 x 102 x 20 mm 78 x 92 x 42 mm
IP 30 IP 45
R&TTE 1999/5/CE
www.deltadore.com
Important product information (➋➍)
ON
12
ON
12
ON
1
2
3
N
S
W
E
Install the outdoor sensor (TYBOX 337 only)
Press t ime
Association
Slow flashing
LED off
Room temperature
Set-point temperature
Daily programming
2 daily programs (week + week-end
Weekly programming
PROG
x1
PROG
x7
PROG
5+2
> 5s
... ... ...
OFF
- it must be installed vertically as shown on the diagram opposite.
- The recommended position is on a wall facing north
or north-west, so that it is not directly exposed to adverse weather conditions, and away from heat sources such as chimneys,
air vents and thermal bridges.
Getting started
• Unscrew the 3 screws on the front of the sensor, then lift the cover.
• Set the 2 switches to ON to activate the sensor
The outdoor sensor must be attached using screws and plugs (not provided) suitable for the surface you are attaching it to:
Operate the switch to select
the type of programming
or
>10s
... ... ...
NO
NC
Thermostat input
Blue
Brown
Black
Gray
Installing the receiver
Replacing the batteries
1
3
4
2
1
31
1
12
0
23
0
59
2012 ...
EXIT
1
2
3
4
5
8
9
10
11
12
6
7
Time setting
1,5V - LR03/AAA
(Alkaline)
NO : Normally Open
NC : Normally Closed
Circulator control for the
boiler
Input control for boiler
thermostat
Mounting with screws
Attach to the wall using the screws and plugs provided.
Mounting using double-sided adhesive
Before affixing the adhesive, make sure the surface you are affixing it to is clean
The receiver must be positioned near the heating control (burner or thermostat input of the boiler). So as not to disturb the radio transmission, the antenna must be positioned away from all metallic parts.
You can change the direction of operation of the relay
When there is an "on" command, the relay closes. When there is an "off" command, the relay opens. You can change the direction of operation of the relay by pressing the corresponding button on the receiver for 10 seconds.
Turn the selector dial to .
The days flash.
Press + or - to select the day, then press OK to confirm and move on to the next setting.
Repeat the process to set the hours and minutes.
To exit the "time setting" mode, turn the selector dial.
You have approximately 30 seconds to change the batteries before the time setting is reset (if this happens, reprogramme the date and time).
When the batteries symbol appears. you have approximately 1 month to change the batteries (2 1.5 V LR03 or AAA alkaline batteries).