Delta 217 TYBOX Installation

NL
123
R CT
123
R CT
321 45
RLN CT
TYBOX 117 - TYBOX 217
TYBOX 127 - TYBOX 227
Th
Th
NL
RLN CT
NL
3
5
4
6
2
~1,50 m
Mini 20 cm
1
TYBOX 1x7
PROG
x 1
PROG
x 7
PROG
5 + 2
TYBOX 2x7
A
B
A B
Installation
*2703291_Rev.2EN*
TYBOX 117 - 127
217 - 227
TYBOX 117 - 217 TYBOX 127 - 227
2 x 1,5V LR03 - AAA Alkaline 230 V~ 50 Hz +/-10%
2 A max., 230V~ (Type 1.C)
°C -5°C / +40°C
80 x 103 x 25 mm
IP 30
2004/108/CE - 2006/95/CE
www.deltadore.com
Important product information ()
Press time
Room temperature
Set-point temperature
Daily programming
2 daily programs (week + week-end)
Weekly programming
PROG
x1
PROG
x7
PROG
5+2
> 5s
Operate the switch to
select the type of
programming
Circulator control
for the boiler
Input control for
boiler thermostat
Circulator control
for the boiler
Input control for
boiler thermostat
>5s
2
0
1
0
1
0
EXIT
1
2
3
4
5
6
7
8
9
10
MENU 1
Length of a programme stage
Prog
60', 30', 15'
Tybox
1x7
Tybox
2x7
X
60 min.
30 min.
15 min.
1
31
1
12
0
23
0
59
2012 ...
1
2
3
4
5
8
9
10
11
12
6
7
EXIT
Time setting
Turn the selector dial to .
The days flash.
Press + or - to select the day, then press OK to confirm and move on to the next setting.
Repeat the process to set the hours and minutes.
To exit the "time setting" mode, turn the selector dial.
Turn the selector dial to , then press the i button for 5 seconds.
Press button1,
To change the different settings, press the + or - buttons, then press the OK button to confirm and move on to the next setting.
To exit the mode, turn the selector dial to another mode
Tybox
1x7
Tybox
2x7
X
Comfort regulated by TYBOX
Comfort temperature set on each radiator or convector
For electrical or hot-water heating systems with thermostatic valves, the thermostat for each radiator or convector may be adjusted to give a comfortable temperature. In this case, the TYBOX only regulates the Economy and Frost-Protection temperatures.
Tybox
1x7
Tybox
2x7
X X
Anti-seizing off
Anti-seizing on (circulator pump ON: 1 minute / 24h)
MENU 2
>5s
1
0
1
2
3
4
5
EXIT
1
0
Press button 2.
To change the different settings, press the + or - buttons, then press the OK button to confirm and move on to the next setting.
Turn the selector dial to , then press the i button for 5 seconds.
To exit the mode, turn the selector dial to another mode.
Permission to change
Programme and settings
0 : Modifications permitted to programme and settings
1 : Modifications to programme not permitted and adjustment of settings limited. Tybox 1x7 : Comfort setting limited between 16 and 22°C. Tybox 2x7 : +/- 3°C +/- 3°C either side of the last setting.
Tybox 1x7 Tybox 2x7
X X
: 5°C < < 30°C
: 5°C < < 16°C
16°C < < 22°C
13°C < < 19°C
5°C < < 11°C
+/- 3°C
PROG
Temperature displayed in AUTO mode
0 : Continuous display of the temperature setting. In this case, press the i button to display the room temperature
1 : Continuous display of the room temperature. In this case, press the i button to display the temperature setting
Tybox
1x7
Tybox
2x7
X
Automatic time change (summer/winter time)
Tybox
1x7
Tybox
2x7
X X
Non
Oui
Time display mode 12h-24h
Tybox
1x7
Tybox
2x7
X X
24h
12h
Measured temperature correction (-5°C à +5°C par pas de 0,1°C).
Example: If the temperature dis­played on the device is 19°C and the observed temperature is 20°C, adjust the temperature by +1°C, then confirm by pressing OK.
Tybox
1x7
Tybox
2x7
X X
- 5°C < < +5°C
Before changing this setting, the device must have been in operation for at least 2 hours.
Time before boiler maintenance (0 to 365 days)
Reprogramme after each maintenance operation
Tybox
1x7
Tybox
2x7
X X
--- (0) to 365 days
>5s >5s
OR
1
2
3
4
3
4
EXIT
Init
Menu 1
Init
Menu 2
The factory settings
TYBOX 127 - 227
1
3
4
2
The factory settings may be restored for each of the menus.
Turn the selector dial to , then press the i button for 5 seconds.
Press the button for 5 seconds on the menu you wish to reset.
Press OK to confirm the reset.
To exit the mode, turn the selector dial to another mode.
You have approximately 30 seconds to change the batteries before the time setting is reset (if this happens, reprogramme the date and time).
When the batteries symbol appears. you have approximately 1 month to change the batteries (2 1.5 V LR03 or AAA alkaline batteries).
Alkalines 1,5V
LR03 (AAA)
Reset operating counter hours of the boiler
Tybox
1x7
Tybox
2x7
X X
No
Ye s
0,2°C < < 2°C
Hysteresis
0,4°C
Control time base
If you choose an "on/off" type setting, you can adjust the hysteresis (or differential) via menu 2-11
Tybox
1x7
Tybox
2x7
X X
Minutes
Minutes
Minutes
Minutes
On/Off