DeLonghi T SERIES Instruction Manual

De’Longhi S.p.A.
Via Seitz, 47
31100 TREVISO
Italy
www.delonghi.com
5715110131/07.08
IMPORTANT SAFEGUARDS
• Use this appliance only as described in this instruction manual. As with all electrical equip­ment, whilst the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance.
• This appliance is designed for home air conditioning and must not be used for other pur­poses
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• The appliance must be installed in conformity with national legislation regulating electrical equipment and installations.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. Repairs carried out by unauthorised personnel may be dangerous.
• This appliance must be used exclusively by adults.
• Never allow the appliance to be used by people (including children) with psychological, physical or sensory impairments or with insufficient experience and knowledge, unless clo­sely supervised and instructed by someone responsible for their safety. Young children should be supervised to ensure that they do not play with the appliance.
• The appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance, always unplug the appliance from the mains socket.
• Never unplug the appliance by pulling on the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sour­ces of heat
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pres­surised containers (eg aerosol cans).
• Do not rest heavy or hot objects on top of the appliance.
• Clean the air filter at least once a week.
• Avoid using heating appliances near the air conditioner.
• Always transport the appliance upright or resting on one side. Before moving the applian­ce, empty the internal circuit completely of water. After moving the appliance, wait at least 1 hour before starting it.
• When putting the appliance away, do not cover with plastic bags.
• The materials used for packaging can be recycled. You are therefore recommended to dis­pose of them in special differentiated waste collection containers.
• At the end of its working life, consign the appliance to a specialist collection centre.
• If the power cable is damaged, it must be replaced by the manufacturer or an authorised technical service centre in order to avoid all risk.
• Before transporting the appliance, completely empty the internal circuit of water by pres­sing the MODE and FAN buttons simultaneously for a few seconds without removing the tank. Then empty the tank
SPECIFIC WARNINGS FOR APPLIANCES WITH R410A* REFRIGERANT GAS
R410A refrigerant gas conforms to EC regulations on the environment. Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION:
This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol. Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).
* Verify the type of refrigerant gas used in your appliance on the rating plate.
2
Important information for correct disposal of the product in accordance with EC Directive
2002/96/EC.
At the end of its working life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service. Disposing of a household appliance separately avoids possible negative consequences for the environment and health deriving from inappropriate disposal and enables the constituent materials to be recovered to obtain significant savings in energy and resources.As a reminder of the need to dispose of household appliances separately, the product is marked with a crossed­out wheeled dustbin.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
the power socket and electrical circuit are adequate for the appliance.
the mains socket matches the plug. If this is not the case, have the plug replaced;
the mains socket is adequately earthed. Failure to follow these important safety instructions
absolves the manufacturer of all liability.
3
SPECIFIC WARNINGS FOR APPLIANCES WITH R290* REFRIGERANT GAS
Read the warnings carefully.
When defrosting or cleaning, use only the implements recom­mended by the manufacturer.
The appliance must be placed in a room without continuously operating sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn.
Refrigerant gas may be odourless.
The appliance must be installed, used and stored in a room with a surface area greater than 15 m
2
.
This appliance contains about 300 g of R290 refrigerant gas.
R290 refrigerant gas complies with European environmental directives. Do not perforate any of the components in the refrigerant circuit.
If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters, sto­ves or other sources of ignition.
The appliance must be stored in such a way as to prevent mechanical faults.
Persons working on a refrigerant circuit must have the relative authorisation issued by an accredited body certifying their competence to handle refrigerants in compliance with a standard assessment recognised by sector associations.
All repairs must be carried out in accordance with the manufacturer’s recommendations. Maintenance and repairs requiring the assistance of other qualified personnel must be car­ried out under the supervision of specialists in the use of inflammable refrigerants.
* Verify the type of refrigerant gas used in your appliance on the rating plate.
WHAT IS THE PINGUINO
During the summer, you feel comfortable at a temperature of between 24 and 27° C with a relative humidity of about 50%.
An air conditioner removes excess moisture and heat from the room where it is located. Compared with installed models, portable air conditioners have the advantage that they can be moved from one room to another in the home or be transported from one building to another.
Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re­emitted into the room.
In single unit models, a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside.
MODELS WITH R290 REFRIGERANT GAS
The Pinguino ECO is a latest generation environmentally-friendly air conditioner. The Pinguino ECO does not, in fact, contain gases (CFC/HCFC) dangerous to the ozone layer or with a marked greenhouse effect (HFC).
4
DESCRIPTION
A Air outlet grille
B control panel C castors D handles E evaporator air intake grille with dust filter F air exhaust hose housing G condenser air intake grille H continuous condensate drain connection I condensate tank J power cable K flange cap L air exhaust hose M window outlet N suckers O castor locks P continuous drain hose with coupling Q remote control R 3M air purifying filter S silver ion filter (certain models only) T adjustable bar
LL
QQ
MM
SS
RR
NN
OO
KK
TT
AA
BB
CC
DD
FF
GG
EE
II
HH
JJ
PP
5