SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
GENERAL INFORMATION
SAFETY RULES AND RECOMMENDATIONS FOR THE USER
GENERAL INFORMATION
Read this guide before installing and using the appliance.
Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner.
Carry out a test cycle after installing the air conditio­ner and record the operating data.
The ratings of the fuse installed in the built-in control
VOJU BSF  " & 7
The user must ensure that the whole unit is protec­ted by a fuse of adequate capacity in relation to the maximum input current or by another overload pro­tective device.
Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the risk of electric shock or fire due to insufficient contact.
Check that the socket is suitable for the plug, otherwise have the socket changed.
Make sure that the base of the outdoor unit is firmly fixed.
Do not install the appliance at a distance of less than 50 cm from inflammable substances (alcohol, etc.) or from pressurised containers (e.g. spray cans).
If the appliance is used in areas without the possibility of ventilation, precautions must be taken to prevent any leaks of refrigerant gas from remaining in the environ­ment and creating a danger of fire
The packaging materials are recyclable and should there­fore be disposed of in the relative separate waste bins. Take the air conditioner at the end of its useful life to a special waste collection centre for disposal.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.
The appliance must be installed in accordance with applicable national regulations.
Before accessing the terminals, all the power circuits must be disconnected from the power supply.
Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the risk of electric shock or fire due to insufficient contact.
Do not pull out the plug to switch off the appliance when it is in operation, since this could create a spark and cause a fire, etc.
The user is responsible for having the appliance installed by a qualified technician, who must check that it is earthed in accordance with current legisla­tion and insert a thermomagnetic circuit breaker.
Prolonged exposure to cold air is harmful to health.
If the appliance gives off smoke or there is a smell of burning, immediately cut off the power supply and contact the Service Centre.
Have repairs carried out only by an authorised Servi­ce Centre of the manufacturer. Incorrect repair could expose the user to the risk of electric shock, etc.
Ensure that the appliance is disconnected from the power supply when it will remain inoperative for a long period and before carrying out any cleaning or maintenance.
This appliance must only be used by adults; do not allow children or persons with reduced psycho­physical-sensorial abilities to use it.
Selecting the most suitable temperature can prevent damage to the appliance.
The airflow direction must be properly adjusted. The flaps must be directed downwards in the heating mode and upwards in the cooling mode.
This appliance has been made for air-conditioning domestic environments and must not be used for any other purpose, such as for drying clothes, cooling food, etc.
The packaging materials are recyclable and should there­fore be disposed of in the relative separate waste bins. Take the air conditioner at the end of its useful life to a special waste collection centre for disposal.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.
Cleaning and maintenance must be carried out by specialised technical personnel. In any case discon­nect the appliance from the mains electricity supply before carrying out any cleaning or maintenance.
+
21
C
10
15
6
7-8
9
2-3-4
SINGLE SPLIT
3
ENGLISH
11
12
13
Do not bend, tug or compress the power cord since this
could damage it. Electrical shocks or fire are probably
due to a damaged power cord.
Specialised technical personnel only must replace a
damaged power cord.
Do not use extensions or gang modules.
Do not touch the appliance when barefoot or parts of
the body are wet or damp.
Do not obstruct the air inlet or outlet of the indoor
or the outdoor unit.
In no way alter the characteristics of the appliance.
Do not install the appliance in environments whe-
re the air could contain gas, oil or sulphur or near
sources of heat.
Do not climb onto or place any heavy or hot objects on top of the appliance.
Do not leave windows or doors open for long when the air conditioner is operating.
Do not direct the airflow onto plants or animals.
Do not spray water onto the air conditioner.
Do not climb onto or place any objects on the out­door unit
Never insert a stick or similar object into the appliance. It could cause injury.
SAFETY RULES AND PROHIBITIONS
GENERAL INFORMATION
NAMES OF THE PARTS
GENERAL INFORMATION
INDOOR UNIT
No. Description
1 Front panel
2 Air filter 3 Antibacterial silver ion filter (if installed) 4 Deodoriser biologic electrostatic filter (if installed) 5 Terminal block cover 6 Automatic restart button 7 ECC LED display 8 Signal receiver 9 Airflow direction flaps
10 Intelligent remote control
OUTDOOR UNIT
No. Description
11 Air outlet grille
12 Handle 13 Fittings cover (if present)
Note: the above figures are only intended to be a simple
diagram of the appliance and may not correspond to the appearance of the units that have been purchased.
SINGLE SPLIT
ENGLISH
4
MODELS
9K 12K 18K 24K
General data
Electricity supply 230~50 (*) 7_)[
Refrigerant gas R410 A (**) Fuse 10 15 15 15 A Minimum cable section 1,5 2,5 2,5 2,5 mm
2
Size and clearance
P
L
H
B
E
A
D
C
L 770 830 1020 1020 mm
H 250 285 310 310 mm
P 205 215 250 250 mm
A 150 mm
B 150 mm
C 2500 mm
D 150 mm
E 300 mm
P
L
H
C
F
D
E
L 763 763 848 848 mm
P 258 258 378 378 mm
H 515 515 620 620 mm
C 300 mm
D 500 mm
F 300 mm
E 2000 mm
Indoor unit net weight 8 11 14 14 kg Outdoor unit net weight 40 40 52 52 kg
Connecting pipes
3FGSJHFSBOU QJQF TJ[F
Liquid
6,0 - 1/4” 6,0 - 1/4” 6,0 - 1/4” 6,0 - 1/4”
Ø-inch
Gas
12 - 1/2” 12 - 1/2” 12 - 1/2” 12 - 1/2”
Ø-inch
Pipe tightening torque
Liquid
20 20 20 20
Nm
Gas
60 60 60 60
Nm
Quantity of refrigerant per metre of pipe (over 5 m) 15 15 22 22 g/m
A
B
C
A
(max)
6688m
B
(max)
25 25 30 30 m
C
(max)
6688m
Refrigerant charge
(***)
g.
Operating limits
Internal part bulb External part bulb Cooling (Max ; Min) 36 ; 16 45 ; -10 °C Heating (Max ; Min) 30 ; 16 27 ; -15 °C
(*) See the rating plate for the electricity supply. (**) The appliance may be supplied with refrigerant gas R22 in countries where the use
of refrigerant gas R410a is not compulsory.
(***) See the rating plate for the refrigerant charge.
TECHNICAL DATA
GENERAL INFORMATION
SINGLE SPLIT
5
ENGLISH
ON-OFF MODELS
7K 9K 12K 18K 24K
General data
Electricity supply 230~50 (*) 7_)[
Refrigerant gas R410 A (**) Fuse 10 10 15 15 15 A Minimum cable section 1,5 1,5 2,5 2,5 2,5 mm
2
Size and clearance
P
L
H
B
E
A
D
C
L 770 770 830 1020 1020 mm
H 250 250 285 310 310 mm
P 205 205 215 250 250 mm
A 150 mm
B 150 mm
C 2500 mm
D 150 mm
E 300 mm
P
L
H
C
F
D
E
L 763 763 763 848 950 mm
P 258 258 258 378 420 mm
H 515 515 515 620 840 mm
C 300 mm
D 500 mm
F 300 mm
E 2000 mm
Indoor unit net weight 8 8 11 14 15 kg Outdoor unit net weight 30 30 38 52 72 kg
Connecting pipes
3FGSJHFSBOU QJQF TJ[F
Liquido 6,0 - 1/4” 6,0 - 1/4” 6,0 - 1/4” 6,0 - 1/4” 10-3/8”
Ø-inch
Gas 10-3/8” 10-3/8” 12-1/2” 12-1/2” 16-5/8”
Ø-inch
Pipe tightening torque
Liquido 20 20 20 20 40
Nm
Gas 40 40 60 60 80
Nm
Quantity of refrigerant per metre of pipe (over 5 m) 20 20 30 50 50 g/m
A
B
C
A
(max)
5 m
B
(max)
10 m
C
(max)
5 m
Refrigerant charge
(***)
g.
Operating limits
Internal part bulb External part bulb
Cooling (Max ; Min)
36 ; 16 45 ; 18 °C
Heating (Max ; Min)
30 ; 16 27; -10 °C
(*) See the rating plate for the electricity supply. (**) The appliance may be supplied with refrigerant gas R22 in countries where the use
of refrigerant gas R410a is not compulsory.
(***) See the rating plate for the refrigerant charge.
SINGLE SPLIT
ENGLISH
6
Led Function
DISPLAY (temp) Indicates the temperature in °C
COOL COOL mode
DRY Dry mode
RUN Indicates switching on of the appliance
ON (led) Shows that the unit is powered
Led Function
SMART SMART mode
FAN Fan mode
HEAT HEAT mode
FAN SPEED
High fan speed Medium fan speed Low fan speed
The shape and position of switches and indicators may vary according to the model, but their function is the same.
Danger of electric shock with open grille.
If the remote control is lost, proceed as follows:
- If the unit is turned off, press the Automatic restart button on the unit to start the air conditioner in the SMART mode. The air conditioner will automa­tically choose the cooling, dehumidifying or heating mode according to environmental conditions to ensure maximum comfort.
-
To turn off the unit, press the
Automatic restart
but-
ton again.
No. Button Function
MODE Selection of mode of operation
ON/OFF On/Off
TEMP DN
Decrease of temperature or time by 1 unit
TEMP UP
Increase of temperature or time by 1 unit
T-ON To set automatic switching-on
CLOCK To set the clock
T-OFF To set automatic switching-off
TURBO POWER
TURBO function
I COMFORT I COMFORT mode
FAN Selection of fan speed
LIGHT
To illuminate/darken ECC display LED of indoor unit
SLEEP Night function
SWING To adjust the position of the aps
SMART (*) Automatic operation
ROOM TEMPERATURE (**)
Temperature display mode
INTELLIGENT REMOTE CONTROL
ON
MODE
OFF
!
+
88
12:38
°C
AUTO
PM AM
ON TIMER
!
OFF TIMER
INTELLIGENT REMOTE CONTROL
ON
MODE
OFF
!
+
88
°C
!
Per impostare l’ora corrente, procedere in questo modo:
- Premere il tasto CLOCK (
)
 4FMF[JPOBSF MPSB TQPTUBOEPTJ DPO J UBTUJ 
) e ( ) Nota: se premuti per più di 2 secondi, l’ora riportata sul display scorrerà velocemente.
- Premere nuovamente il tasto CLOCK per confermare. Nota: se non verrà premuto entro 10 secondi, l’orologio
SJUPSOFSÆ BMMJNQPTUB[JPOF PSJHJOBMF
(*) Only on B Logic remote control (**) Only on F Logic remote control
B Logic
Remote control
F Logic
Remote control
OPERATION AND EEC (Electronic Climate Control) DISPLAY
USER
REMOTE CONTROL
USER
Loading...
+ 14 hidden pages