Safety standards 2
Identification of the parts 4
Remote control 6
Operating modes 8
AUTO mode 9
TIMER mode 9
DRY mode 10
SLEEP mode 10
Maintenance 11
Troubleshooting 12
Installation instructions 13
Installation of the indoor unit 15
Installation of the outdoor unit 19
Venting the air 19
Note 20
Useful information 20
U AI
U AI
U A
I
U AI
U A
I
U AI
U A
I
U AI
U AI
U A
I
AI
A
I
AI
A
I
U AI
U A
I
U User I Installer A Service
SINGLE SPLIT
2 English 11/2002
Use the power supply voltage shown on the rating plate. Keep the power switch or plug clean. Connect the power cable correctly and securely to the out­let, avoiding the risk of electric shock or fire due to insufficient contact.
Check that the outlet is suitable for the plug, oth­erwise have the outlet replaced. Do not use the power switch or pull out the plug to switch the appliance off when operating. This may cause fires due to sparks,etc.
The user must contact qualified personnel to earth the appliance, in compliance with the legis­lation in force, and to install a thermal-magnetic circuit breaker.
Do not bend, pull or press the power cable, as it may break.Electric shock or fire are usually caused by damaged power cables. The power cable must only be replaced by special­ist technicians.
Do not use power supply cables that are too long,or multiple adapters.
Do not operate the air-conditioner with wet hands;this may cause electric shock.
Do not modify or alter the characteristics of the appliance in any wa y. Contact the Service Centres authorised by the Manufacturer for all repairs.Incorrect repair may cause electric shock,etc.
Make sure the appliance is disconnected from the power supply when not used for extend­ed periods, and before performing any clean­ing or maintenance operations.
Do not install the appliance in environments where the air may contain gases,oil or sulphur, or near sources of heat.
Check that the base of the outdoor unit is installed securely.
This appliance must only be used by adults; do not allow children to play with the appliance. Do not climb onto or rest objects on the out­door unit.
Never insert sticks or tools into the appliance. This may cause injuries.
Do not block the air inlet or outlet of either the indoor or outdoor unit. Extended exposure to cold air is a health risk.
If smoke or a smell of burning is detected,imme­diately disconnect power and contact the Service Centre.
SAFETY STANDARDS AND WARNINGS
U I A
SINGLE SPLIT
3English 11/2002
Keep the appliance at least 50cm from flamma­ble substances (alcohol, etc.) or from pres­surised containers (e.g.spray cans).
Selecting the most suitable temperature will avoid damaging the appliance.
The direction of air flow must be adjusted correct­ly.The louvers must be adjusted downwards in heating mode,and upwards in cooling mode.
Do not leave doors and windows open when the air-conditioner is operating f or long periods.
Do not aim the air stream directly at plants or animals. Do not spray water onto the air-conditioner .
This appliance has been designed to air-condition the home and must not be used for other pur­poses,such as drying clothes, cooling food,etc.
If the appliance is used in areas without the renewal of fresh air, precautions must be taken to prevent any leaks of refrigerant gas from stagnating in the environment and creating the risk of fire. Do not rest heavy or hot objects on the appliance.
The packing materials are recyclable.It is therefore recommended to place them in suitable containers for separate waste disposal. At the end of its working life, take the air-condi­tioner to a special waste disposal centre.
Only use the air-conditioner as shown in this booklet. These instructions are not intended to cover every possible situation that may arise. Common sense and prudence must be applied in the installation,operation and conservation of all household appliances.
Lowers
the inside temperature by 5°C from
the outside
temperature
Working temperature range
Maximum cooling
Maximum heating
Minimum cooling
Minimum heating
36
Indoor side DB()
30
16
16
45
Outdoor side DB()
27
18
-10
SINGLE SPLIT
4 English 11/2002
IDENTIFICATION OF THE PARTS
AUTO TEST RUN STOP
AUTO STOP
1
4
5
11
10
7
9
6
8
12
4
4
14
13
2
3
Air inlet
INDOOR UNIT
OUTDOOR UNIT
The above figure represents a simplified layout of the appliance and may not correspond to the appearance of the unit actually purchased.
U I A
Air outlet
Air inlet
Air outlet
1Front panel 2 Air filter 3 Electrostatic filter (optional) 4 Manual switch 5 Cable panel 6 Activated carbon filter 7 Louvers 8 Signal receiver 9 LED display 10 Power plug 11 Drain hose 12 Remote control 13 Handle 14 Air outlet grill
4
AUTO
STOP
RUN
TEST
SINGLE SPLIT
5English 11/2002
1
2
3
4
5
AUTO TEST RUN STOP
1. Manual switch
This is used to start the appliance if the remote con­trol is not working.*
2. Heating indicator
This comes on when the appliance is in heating mode.
3. Cooling indicator
This comes on when the appliance is in cooling mode.
4. Operation indicator
This comes on when the appliance is operating.
5. Signal receiver
Receives the signals from the remote control.
OPERA TION AND DISPLA Y
The shape and the position of the switches and indicators may change according to the model, howe v er their functions r emain the same.
Power on when grill open.
*This operation must be carried out by spe­cialist technicians.
REMOTE CONTROL
SINGLE SPLIT
6 English 11/2002
3 4
1
5 6
7
10
2
8
9
1. Liquid crystal display
Displays all the operating modes.
2. MODE button
Used to select the operating mode.
3. FAN button
Used to set the fan speed, in sequence , to automatic, low,medium,high.
4. SLEEP button
Used to set or cancel SLEEP mode.
5. SWING button
Used to start or stop the movement of the vertical louvers.
6. TIMER ON button
When the appliance is off, this button is used to switch the air-conditioner on automatically.
7-8. ROOM TEMPERATURE SETTING buttons
Used to set the room temperature.
9. TIMER OFF button
When the appliance is on, this button is used to switch the air-conditioner off automatically.
10. button
Used to switch appliance on or off.
Meaning of the symbols shown on the liquid crystal display:
Automatic fan speed Low fan speed Medium fan speed High fan speed Cooling indicator Dehumidification indicator Fan only operation indicator Heating indicator Automatic mode indicator SLEEP indicator Louver swing indicator
The display on the remote control remains on even when the unit is off.
The remote control sends signals to the appliance.
U I A
Loading...
+ 14 hidden pages