Delonghi CF 1130 Instructions Manual

16
Important safeguards
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
•The appliance must be installed in conformity with legislation in force in the country concerned.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. Repairs carried out by unauthorised personnel may be dangerous.
• This appliance must be used exclusively by adults.
• Do not allow children or unfit persons to use the appliance without adequate supervision.
• Do not allow children to play with the appliance.
• he appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
• Do not rest heavy or hot objects on top of the appliance.
•Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioner.
• Always transport the appliance upright or resting on one side.
•Use the appliance as described in this instruction manual only. As with all electrical equipment, whil­st the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance.
•At the end of its working life, take the appliance to a special collection centre.
• The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers.
• The refrigerant gas R407c conforms to EC regulations on the environment. Avoid perforating the refri­gerant circuit of the appliance.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (e.g. aerosol cans).
DESCRIPTION 1 air outlet grille 2 control panel 3 handles 4 castors 5 filter 6 evaporator air intake grille 7 external unit fixing screws 8 cover for quick-fit coupling compart-
ment (some models only)
9 water drain hose
10 power cable compartment 11 external unit handle 12 two mounting brackets with screws 13 two spanners (some models only) 14 four wall plugs with screws (some
models only)
15 two belts with hooks 16 one frame with sheath 17 four protective caps for connectors
(some models only)
18 remote control unit
GB
17
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
INSTALLATION
The sheath connecting the external and inter­nal units can pass: a) through a window or door left ajar (fig. A).
A
Preparing for use
USING THE QUICK-FIT COUPLINGS (some models only)
In addition to the methods described above, the sheath connecting the external and inter­nal units can also pass through a hole with a diameter of about 6 cm cut in an outside wall (fig C) proceeding as follows:
b) Through a small hole (5.5 cm x 2.5 cm) cut
in the bottom part of a door or in a win­dow frame, protecting the sheath by using the frame provided (fig. B).
B
ø6
cm
30
C
Turn the appliance off and unplug from the mains. Wait about 30 minutes before following the instructions below:
1) Remove the screws and take off the cover of the quick-fit coupling compartment.
2) Press the tab to disconnect the electrical connection.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• the mains socket and electrical circuit are adequate for the appliance;
• the mains socket matches the plug. If this is not the case, have the plug replaced;
• the mains socket is adequately earthed.
• the mains socket is adequately earthed. Failure to follow these important safety instructions absolves the
manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
18
Preparing for use
3) Remove the metal hose mounts.
How to reconnect the quick-fit couplings
To reconnect the quick-fit couplings, repeat the previous operations in reserve, taking the following precautions:
• Before passing the sheath through the hole in the wall, you should protect the threaded ends of the quick-fit couplings with insulating tape or similar.
•Fit the two refrigerant couplings together, making sure they are perpendicular with respect to the appliance. Screw them up a couple of turns by hand to make sure they fit together correctly, then tighten using the spanners used previously.
• After connecting the two refrigerant cou­plings, fix the two metal mounts.
• Check the tightness of the refrigerant cou­plings by moistening the junctions with a little soapy water. No soap bubbles should form.
INTERNAL UNIT
Install the internal unit in the room to be air conditioned. It should usually be beneath a window or in any case near an outside wall. The internal unit must be level. The air intake and outlet grilles of the internal unit must always be kept free.
EXTERNAL UNIT
1) The external unit can be stood on a terra­ce or balcony. In this case, it is not neces­sary to use the mounts.
4) Remove the rubber insulation around the connection.
5) Use the two spanners supplied to uncou­ple the two hoses.
6) Screw the caps provided onto both the disconnected parts.
7) Disconnect the condensate drain hose carefully as water may leak out.
Important
You are recommended to have the quick-fit couplings disconnected and reconnected by a qualified professional.
WARNING
To avoid leaks of refrigerant while disconnec­ting and reconnecting the quick-fit couplings, make sure the hoses are perpendicular with respect to the appliance.
Important
Make sure the external unit water drain hose is free from kinks or obstructions.
GB
19
Preparing for use
2) The external unit can be hung on a wall using the mounts supplied. In this case, proceed as follows:
a) Fix the mounts to the wall, making sure
they are positioned as shown in the figure.
b) Hook the external unit to the mounts and
fix with the screws provided.
3) Alternatively, to install temporarily, the external unit can be hung as follows:
a) Attach the mounts to the external unit and
fix them using the screws provided.
b) Attach the belts to the mounts. c) Attach the other end of the belts securely.
The external unit can be installed on the same level as the internal unit or higher, provi­ded the difference in height does not exceed
1.5 m.
The air intake and outlet grilles of the external unit must always be kept free. Condensate forming during air conditioning (summer mode) is eliminated through evaporation from the external unit.
Important:
The external unit must be protected from rain and bad weather.
In particular cases of exceptionally high humi­dity, the condensate must be eliminated using the condensate drain hose (after remo­ving the rubber cap).