Thank you for your purchase of Delmhorst Instrument’s Navigator Pro handheld moisture meter /
thermo-hygrometer. Navigator Pro has been developed specifically with the restoration
contractor in mind. It provides the user with a host of data acquisition capabilities, and offers the
latest in features and functionality. Even with its wide range of functions, Navigator Pro is
intuitive and easy to operate. We recommend that you read the following pages in detail to take
full advantage of all that Navigator Pro has to offer.
Outstanding Features:
Pin mode
o 5%-60% wood scale (Douglas Fir)
Species corrections for SPF, Oak, Maple, Birch, Plywood, OSB and
Particleboard
o Temperature correction over the range of 0-255° F/-18-124°C
o 0.1% - 6% Sheetrock® scale
o 0-100 numerical reference scale for non-wood building materials, including
Plaster and Concrete
Scan Mode
o 0-300 numerical reference scale
Thermo-hygrometer (RH/T-S1 sensor included)
o Measures RH over the range of 0-100% (with accuracy of +/- 2% over 10%-90%)
o Measures temperature over the range of -40°F-255°F with accuracy of +/- 1.8°F
over -4°F to 158F (range of -40°C - 124°C with accuracy of +/- 1°C over -20° to
70°C)
o Calculates Dew Point over the range of -40°F - 176°F (-40°C - 80°C)
o Calculates GPP (Grains Per Pound) when in Fahrenheit mode over the range of
0.1-3820 GPP
o Calculates GPK (Grains Per Kilogram) when in Celcius mode over the range of
0.01-545 GPK
o Conforms to ASTM-F-2170 for in-situ concrete slab testing (RH/T-S3 sensor
required)
General Features:
o Connector for external Electrodes
o On-screen reading recall of stored readings
o Date and time stamp for each stored reading
o Set up to 5 job groupings with room and location definition
o Optional infrared linking capability w/ application software
o 9V battery
o 1-year warranty
o Carrying Case
To turn the meter on, press and hold the SELECT button for approx. 2 seconds.
The first screen will temporarily display the meter name and the software revision level. Refer to
this revision level whenever you call Customer Service.
The next screen is theMAIN MENU. Use keys to select the desired
function/mode and then press SELECT to activate the function.
METER USE
BASIC AND ENHANCED MODES:
Navigator Pro may be used as a BASIC meter, which allows the user to begin taking readings
in either the scan mode or pin mode, without having to set up a job definition. BASIC mode does
not allow for data collection and is the default mode of the meter upon power up.
Or, Navigator Pro may be used inENHANCEDmode, which requires the user to set job
definitions and materials for each location within a job. The meter also stores each reading in
ENHANCED mode to allow for on screen reading recall or download to a PC.
USING THE METER IN BASIC MODE:
Navigator Pro is shipped from the factory set to BASIC mode. Use this option if you wish to use
the meter for scan or pin readings without having to set up a job.
Although Basic Mode does not allow for data acquisition, it does allow the user to set the type of
material being tested, and set the alarm to sound if a pre-established %MC is exceeded.
TO TAKE PIN READINGS IN BASIC MODE:
1. From the BASIC Main Menu, use thekey to highlight PIN MODE. Then, use the
SELECT key to enter the pin mode.
2. The meter will displaythe main %MC READscreen, as shown below:
3. Use the key to highlight the default material (Oak) if you wish to change it to a
different material. Press the SELECT key to get into the SELECT MATERIAL sub menu.
4. Use the keys to highlight the material you are testing. Press the SELECT key to
choose that material. This will bring you back to the main %MC READ screen.
You may begin taking readings by inserting the pins into the material and pressing the
SELECT key. This will display a %MC reading. If you wish to hold a reading on screen,
press the SELECT key again; otherwise remove the pins from the material being tested
and take another reading.
TO SET THE ALARM IN BASIC PIN MODE:
1. If you wish to set the alarm to beep after a pre-selected %MC value is reached, use the
keys from the %MC screen to highlight the ALARM. Press the SELECT key to
enter the alarm sub menu.
2. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.
3. After the alarm is turned on, use the keys to scroll up or down to a higher or
lower alarm value.
4. After you have selected the alarm value, use the key to highlight DONE. Press
SELECT to get back to the %MC READ screen.
Default alarm settings in pin mode are as follows for different materials:
All wood materials: 12%
Sheetrock/Gypcrete: 1.0%
Plaster: 68 (on the 0-100 relative scale)
Concrete: 68 (on the 0-100 relative scale)
Note: The default alarm setting in scan mode is 300.
Navigator Pro defaults to a temperature of 70ºF. As wood temperature increases, its electrical
resistance decreases and indicated moisture content rises. Lower wood temperatures result in
lower indicated moisture content. A correction is necessary if the wood temperature is outside
the range of 50ºF (10ºC) to 90ºF (32ºC). Set the temperature accordingly and the meter will
make the correction.
1. To change temperature, use the keys from the %MC READ screen to highlight
the TEMPERATURE, T: 70ºF. Press the SELECT button to get into the TEMPERATURE sub menu.
2. To scroll through the temperature settings, use the keys to scroll up or down to
a higher or lower temperature value. Temperature values will change in 5F increments.
3. To change between ºC and ºF press SELECT key when the COMPTEMP is
highlighted.
4. After you have selected the appropriate temperature setting, use the key to highlight
DONE. This will bring you back to the %MC READ screen and you may begin taking
readings.
TO TAKE SCAN READINGS IN BASIC MODE:
1. From the BASIC Main Menu, use the key to highlight SCANMODE. Then, use
the SELECT key to get into the SCAN mode main menu.
The meter will display the main SCAN mode main menu, as shown below:
2. You may begin taking readings by firmly pressing the back of the meter onto the
material. This will display a relative reading that ranges between 0 and 300. If you wish
to hold a reading on screen, press the SELECT key; otherwise move the meter to
another area to take continued readings.
TO SET THE ALARM IN BASIC SCAN MODE:
1. If you wish to set the alarm to beep after a pre-selected relative value is reached, use
the keys from the SCAN screen to highlight the ALARM. Press the SELECT key
to enter the alarm sub menu.
2. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.
3. After the alarm is turned on, use the keys to scroll up or down to a higher or
lower alarm value.
4. After you have selected the alarm value, use the key to highlight DONE. Press
SELECT to get back to the %MC SCAN screen.
Note: Default alarm setting for SCAN mode is 300.
TO TAKE TEMP/RH READINGS IN BASIC MODE:
Before entering the RH-T mode, firmly insert the RH/T-S1 sensor into the top of the meter,
making sure to align the pin-out on the DIN connector.
1. From the BASIC Main Menu, use the key to highlight RH-TMODE. Then, press
the SELECT key to get into the RH-T mode main menu.
The meter will display the main RH-T mode main menu, as shown below:
2. The meter will begin taking readings.
Note: You may change the temperature mode between °F and °C by highlighting the F°
C° in the lower left hand corner of the screen and pressing the SELECT key. When in
°F mode, Absolute Humidity will be displayed in GPP. When in °C mode, Absolute
Humidity will be displayed in GPK.
TO RESET THE METER TO DEFAULT SETTINGS IN BASIC MODE:
1. Use the keys from the BASIC main menu to highlight #5: DEFAULTS. Press
the SELECT key. The meter will display the following question:
2. Use the keys to answer “YES” or “NO.” If you answer “yes,” the meter will
return to factory default settings in basic mode; i.e. Species = Oak, Temperature
correction = 70° F, Alarm = OFF in pin mode. In Scan mode, Alarm = OFF.
USING THE METER IN ENHANCED MODE:
To use Navigator Pro in enhanced mode, use the keys to highlight #4: ENHANCED. The
Main Menu in ENHANCED mode is as follows:
Setting the meter to enhanced mode requires you to create job definitions and store readings as
described below.
NOTE: Although Navigator Pro’s default mode is BASIC, it will remember the mode last
saved at power off, and will remain in the saved mode at next power up.
Settings stored in each particular mode will not be affected by restoring defaults in a
different mode.
JOB DEFINITION:
Using Navigator Pro in ENHANCED mode allows you to define up to 5 jobs, and select locations
and materials being tested for each location. In this mode, Navigator Pro also stores each
reading and allows you to download the data to a PC or laptop via Infrared connection.
1. From the Enhanced Main Menu, use the keys to highlight JOB DEF.
2. Select a job number (from 1 to 5), using the keys.
3. Press the key and highlight DONE. Press SELECT.
If the job was previously defined and used, you will be asked if you want to “Update” the
job.
4. Select YES if you want new measurements stored under the same job number.
If it is a new job, the next screen will allow you to completely define the job.
To define a job means to choose between residential or commercial, allocate a 3 digit job ID
number, specify the temperature at which measurements will be taken, select from a list of each
of the rooms in which measurements will be taken, and select the materials used for each
location.
TO CHOOSE BETWEEN RESIDENTIAL AND COMMERCIAL:
Highlight the word COMMERCIAL and press the SELECT key. The following screen will appear:
Use the keys to toggle between residential and commercial. After you have made your
selection, highlight DONE and press SELECT.
Please refer to Appendix A for a list of location definitions for residential jobs.
TO SET THE ID NUMBER:
From the “Create Job” screen, the ID field will display the last selected ID number. Press
SELECT on “ID” to enter the ID screen
Select any number between 0 and 999 as the ID of your job, using the keys. Press the
SELECT key after choosing the ID#.
TO SET TEMPERATURE CORRECTION:
Navigator Pro defaults to a temperature of 70ºF. As wood temperature increases, its electrical
resistance decreases and indicated moisture content rises. Lower wood temperatures result in
lower indicated moisture content. A correction is necessary if the wood temperature is outside
the range of 50ºF (10ºC) to 90ºF (32ºC). Set the temperature accordingly and the meter will
make the correction.
1. To change the temperature, use the keys from the CREATE JOB sub menu to
highlight the temperature, T: 70ºF.
2. Press the SELECT key to enter the COMP TEMP sub menu.
3. Using the keys, scroll up or down to a higher or lower temperature value.
Temperature values will change in 5º F increments.
4. To change between C and F, press the SELECT key when the COMPTEMP is highlighted.
TO DEFINE ROOM LOCATION AND MATERIAL DESIGNATION:
1. Using the keys on the CREATE JOB sub menu, highlight LOC DEF and press the
SELECT key.
2. Use the keys to choose different rooms and the keys to switch between
YES and NO options. YES means measurements will be taken in that room. NO means
that you are not going to test in that room. Residential jobs show a list of 32 rooms as
listed below:
Commercial jobs show a list of 32 numerical locations as listed below:
3. With NEXT and BACK you will be able to scroll five pages of room listings. APPENDIX A
contains the list of all available rooms and the abbreviation used for each of them.
To save your settings, use key to highlight DONE and press the SELECT key.
Note:In order to move more quickly through the five pages of room listings,
you may use the key when the cursor is at the top of a page to bring
you down to the bottom of the next page. By doing this and then using
the key to highlight NEXT you will scroll through the pages more
quickly.
Each room will have up to three AREAS for measurements: FLOOR, WALLS and CEILING. If
you choose YES for a room you may now select the material used for each location.
1. Press the SELECT key while the cursor highlights that room and the SELECT
MATERIAL menu will be displayed.
2. Using the keys, select the material or species for that particular room.
Note: The default selection is OAK for the floor and SHEETROCK for the wall and
ceiling. If you are not going to test one of the materials in a room, use the keys
until the word NONE is displayed. This will turn off the ability to read that particular area
in a room.
3. After you have selected each material in a room, highlight DONE press the SELECT
key so that your selections will be saved. This will bring you back to the list of available
rooms. Continue the same procedure as above for each room that you are testing.
Available materials are: Sheetrock®, Plaster, Gypcrete, Concrete, SPF, Oak, Maple, Birch,
Plywood, OSB, Particleboard , Douglas Fir. Select NONE if you are not testing that location.
4. After you have scrolled through all five room pages, select DONE if satisfied with your
selections. This will take you back to the CREATEJOB sub menu.
5. Press DONE to save the job. This will bring you back to the main menu.
TO TAKE SCAN READINGS IN ENHANCED MODE
TO SET THE ALARM IN ENHANCED SCAN MODE:
1. If you wish to set the alarm to beep after a pre-selected relative value is reached,
highlight option #1: SCAN MODE from the ENHANCED main menu. If you have already
set up a job, this will bring you to the SCAN screen. If you have not set up a job, the meter
will prompt you to create one and then will return to the MAIN MENU, at which point you may
select #1: SCAN MODE.
2. Use the and keys and highlight ALARM: OFF. Press the SELECT key to enter the
alarm sub menu.
3. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.
4. After the alarm is turned on, use the keys to scroll up or down to a higher or lower
alarm value.
5. After you have selected the alarm value, use the key to highlight DONE. Press SELECT
to get back to the SCAN screen.
NOTE: Default alarm setting for SCAN mode is 300.
TO TAKE A SCAN READING:
1. In the MAIN Menu, highlight option #1: SCAN MODE
If you have already set up a job, this will bring you to the SCAN screen. If you have not
set up a job, the meter will prompt you to create one and then will return to the MAIN MENU, at which point you may select #1: SCAN MODE.
This screen contains the following information: Job # and ID, current location (LOC),
number of records (REC) for the current room, and memory used (MEM).
Rooms are ordered as in APPENDIX A, Floor (F), Wall (W), and then Ceiling (C). Only
locations for which a material was chosen can be selected for measurements.
2. You may begin taking readings by firmly pressing the back of the meter onto the
material.
3. This will display a relative reading that ranges between 0 and 300. Once you are
satisfied with the value indicated for the selected location, press the SELECT key to
store a reading.
4. You will notice the word HOLD in the right hand side of the screen. If you press the
SELECT key again the meter will store that reading and automatically increment to the
next defined location. (Example: LR, F then LR, W, then LR, C.)
If no storage is desired for this location, manually select a different location by doing the
following:
1. Use the keys to highlight LOC. Press SELECT to get into the LOCATION
definition sub menu.
2. Use the keys to change the location.
Note: You can only scroll through the pre-defined locations and areas as
described above.
3. Select DONE to save your new location; CANCEL to leave the previous location.
TO TAKE PIN READINGS IN ENHANCED MODE
TO SET THE ALARM IN ENHANCED PIN MODE:
1. If you wish to set the alarm to beep after a pre-selected value is reached, use the key
from the ENHANCED main menu, highlight Option #4: SET UP. Press the SELECT key to
enter the SET UP sub menu.
2. Use the key and highlight 6: SET PIN MODE ALARM. You will see a selection of
materials to choose from. Highlight the desired material and press the SELECT key.
3. The default status of the alarm is OFF. Press the SELECT key to turn it on.
4. After the alarm is turned on, use the keys to scroll up or down to a higher or lower
alarm value.
5. After you have selected the alarm value, use the key to highlight DONE. Press
SELECT to get back to the SET ALARM sub menu.
From here, you may continue to set the alarm value for other materials as described above,
or you may scroll to DONE to get back to the MAIN menu.
Default alarm settings in PIN mode are as follows for different materials:
All wood materials: 12%
Sheetrock/Gypcrete: 1.0%
Plaster: 68 (on the 0-100 relative scale)
Concrete: 68 (on the 0-100 relative scale)
Note: Default alarm setting for SCAN mode is 300.
TO TAKE A PIN READING:
1. From the Enhanced Main Menu, use the keys to highlight #2, PIN MODE. If you
are already in the ENHANCED SCAN screen, use the keys to highlight GOTO PIN.
2. Press the SELECT key to get into the ENHANCED READ screen. The current location
will stay the same while toggling between scan and pin modes.
This screen contains the following information: Job # and ID, current location (LOC),
material, the number of records for the current room (REC), and memory used (MEM).
3. Using the external probe, insert the pins into the material, press the SELECT key
and the meter will start taking measurements. Press SELECT again to store the
measurement. The meter will display HOLD. Once you have stored a reading, the meter
will automatically increment to the next available location. Remove the pins from the
material, press SELECT, and move to the next defined location as indicated on the
display.
1. By using the keys you may select which job and location you wish to view.
After you have made your selection, scroll to DONE and press the SELECT key.
Below are three examples of possible screens at this point:
3. A complete record of information per reading will be displayed. You will be able to
scroll through each reading in a room, using the NEXT key.
CLEAR MEMORY:
This option will delete all the readings stored in the meter, but will keep the defined job
structures and associated locations and areas in tact.
RESTORE DEFAULTS:
This will delete all defined parameters and readings stored in the meter. The meter will be
now set to the factory parameters: T = 70°F, Non-insulated probe, Backlight = OFF,
Power-off time = 2 min.
Note: Memory deletion and restoring defaults are both irreversible.
This menu option initiates a wireless communication session during which the currently stored
readings will be downloaded to a PC. Before using this feature, the target PC must be loaded with
Delmhorst Instrument Co’s Universal Application Program and a Delmhorst base unit must be
connected to an available USB port.
REQUIREMENTS:
The wireless communication technology employed in the meter requires line-of-sight access
between the red side window of the meter and the receiving window of the base unit. Simply
place the meter and base unit on a flat surface, with the red side window of the meter facing the
receiving window of the base unit. Separation requirements between the meter and base unit are
anywhere from 0 to 12 inches.
OPERATION:
1. Begin by starting the Delmhorst Instrument Co. Universal Application Program (double
click the application icon or choose the program from the Start Menu).
2. Once the Navigator Pro and base unit are lined up and the base unit is connected to a
USB port (a green LED should be lit), select the IR LINK option in the Main Menu. The meter
will display the message “Linking…” for a few seconds, followed by “Link OK” when
successful communication is established with the base unit. The base unit will also indicate
communication established by turning off the green LED and turning on a red LED.
3. Press the “MANAGE DATA” button in the Delmhorst Instrument Co. Universal
Application Program. The meter will display “Data” on the screen and the base unit will
alternately turn on a yellow and red LED while data transfer takes place (red indicates
communication between the meter and Base Unit, while yellow indicates communication
between the base unit and the PC). When finished, the meter will return to the Main Menu
and the base unit will, once again, turn on its green LED. For further details on managing the
meter data in the PC please refer to the HELP feature in the program.
NOTE: The above sequence of events in initiating communication between the PC and the
meter is not mandatory. The Application Program may be started first, or the IR Link may be
selected first. The MANAGE DATA button may also be pressed before communication is
started between the Base Unitand the meter. The meter, base unit and Application Program
all have ample delays built in to allow the other link components to come online in any
sequence.
TROUBLESHOOTING THE IR LINK:
Most problems tend to occur due to the positioning of the meter relative to the base unit. There
are a few error messages that may appear on the meter’s screen:
a. Timeout: This error message occurs when too much time has passed between data sent by
the meter and the response that should have been received from the base unit. Possible
causes:
Meter misalignment with the Base Unit (make sure the communication windows are
facing each other, within the distance indicated).
No connection to the PC. The Base Unit must be connected to the PC through a USB
cable. Check connection.
b. KBD: This message occurs when the user presses a key during communications. Do not
push any key on the meter during data transfer. The meter interprets this as a request to
escape this activity and returns to the Main Menu. The base unit should return to a green
LED status in a few seconds. A message should appear on the PC screen as well, indicating
lost communications.
c. Sync: This message occurs when data framing is lost during data transmission. This would
only happen if the wireless link becomes unreliable. Ensure the meter and base unit are
aligned and restart the session.
d. Data E: This message occurs when the content of a correctly framed data packet is invalid.
Again, this is an unreliable wireless link problem.
NOTE: Individual records cannot be downloaded to the PC. The entire storage content is
delivered to the PC during a link session.
SETUP MENU:
The Setup group of features allows access to the configurable parameters of the meter. They are:
Date and Time, Power-off time, Backlight, Conversions (temperature mode and electrode type)
and Pin Mode Alarm. All can only be accessed in the Setup Menu. To get to the Setup Menu,
use the keys to highlight option #4: SETUP.
SETUP MENU ENTRY DESCRIPTIONS:
Return to Main Menu: This menu option returns the meter to Main Menu. The meter
also returns to Main Menu if no user input is detected for 20 seconds.
Set Date and Time: This menu option allows user access to the date and time set
screen:
The Date and Time set screen is populated with the time and date values present in the
meter at access time. key action switches the row selection among available
parameters. key action changes the selected parameter’s value. All parameter values
are incremented using the key and decremented using the key. The DAY parameter
moves forward through weekdays using the key and backward using the key. The
SELECT (center) key is only active when menu selection is applied to HOURS, DONE or
CANCEL. Selecting DONE exits this screen back to the SETUP MENU and updates the
clock with the newly chosen values. Selecting CANCEL exits this screen back to the SETUP
MENU without updating the clock.
Set Power Off time: This menu option allows the user to change the amount of time
allowed to lapse between the last key press and meter shut-down. Allowable range is
1min – 9min, with a default value of 2min.
Set Backlight: This menu option allows the user to change the amount of time allowed to
lapse between the last key press and backlight shutdown. The default setting for this
feature is NO, where the backlight is completely disabled. Backlight shutdown delays are
10, 20, 30 seconds. It is recommended that the backlight delay be set to the minimum
amount of time necessary in order to maximize battery life.
Conversions: This menu option allows the user to change the temperature scale from
Fahrenheit (default) to Celsius. You can also change the electrode type from 4-pin (or
non-insulated) or 2-pin (insulated.)
NOTE: Except for clock settings, all other parameters will return to their default values,
as indicated above, when the RESTORE DEFAULTS option is selected in the Storage
Menu. The values chosen for the Setup Menu parameters will remain in effect even if the
meter is turned off, and even if the battery is removed.
The following application notes are intended for use with the meter in PIN
MODE.
TESTING WOOD:
Mount the 26-ES directly to the external connector.
Set the meter’s parameters as described previously in the owners’ manual. If the species
(construction-grade only) is unknown, set the meter to the reference calibration, Douglas Fir
and take the readings at face value.
To take a reading, align the contact pins parallel to the grain and drive them to the desired
depth. Insulated pins read only at the tip.
Press the SELECT button and read the moisture content on the meter scale. The meter
displays the %MC for two seconds.
NOTE: MC RANGE AND VALID READINGS
Readings below 5% or above 60% are displayed as LOW or HIGH, respectively. However, since
the resistance of the wood also depends on the species and temperature of the wood, the meter
may not always be able to read down to 5%. For different species and different wood
temperatures, there is a minimum %MC limit below that the meter can not read. All readings
below this “lowest limit” are displayed as LOW, and are not stored. These readings are not
considered valid readings and are not used by the meter in any statistical calculations.
USING 0-100 NUMERICAL REFERENCE SCALE (REL 0-100)
When taking a reading on hard materials such as concrete or masonry, set the meter to REL 0100 for a qualitative indication of the moisture level.
Make the best use of reference scale by first establishing a benchmark for the material you are
testing. Take readings in areas that you know are dry, or acceptable. Then take readings on
areas that are wet. These “dry to wet” readings can be used as reference points against which
subsequent readings are compared. Understanding the meter’s behavior on a particular material,
along with these comparative readings, your experience, and visual clues will all help determine
the overall condition. All readings should be evaluated in the light of factors such as type of paint,
type of construction, and climatic conditions.
The user-selectable alarm will sound if the displayed reading is above the alarm value.
Moisture meters are an effective tool to check comparative moisture conditions in concrete. They
can tell you where there may be excess moisture and help determine if you need to conduct
further testing, and identify specific areas on which that testing should be performed. Meters do
not provide quantitative results as a basis for acceptance of a slab for installation of moisturesensitive flooring systems. ASTM Test Method F2170 (RH using in situ probes), F1869 (calcium
chloride), and F2420 (RH on surface using insulated hood) provide quantitative information for
determining if moisture levels are within specific limits.
It is important to test both the surface and mid-section of the slab, especially if the slab is on or
below grade. This will help determine if there is continuous moisture migration toward the
surface. If this condition exists, the moisture movement may be so slow that once it reaches the
surface, moisture evaporates and causes a “dry” reading when a surface test is made.
However, if a sub-surface test is made, the meter may read “wet” indicating the presence of
moisture. When the slab is covered and the upward movement of moisture continues, moisture
will move into a hygroscopic (wood) floor, or build-up pressure under a non-breathing synthetic
floor, causing delamination.
Taking a surface reading:
Drive two hardened-steel masonry nails about 3/4" apartinto the finish coat of concrete floor.
Drive them about 1/8" deep so they make firm contact with the concrete and do not move when
touch
Touch the nails with the electrode’s contact pins.
Press the select key and read the meter, set to ‘concrete’. If the meter reads less than
“68”, the surface is dry. However, sub-surface tests should be made to verify if the slab
is dry throughout.
Subsurface test:
Drill two 1/4" holes, 3/4" apart and 1/2" to 2" deep.
Drive the masonry nails into the bottom of the holes and make the tests as described
above. Nails must not touch sides of drilled holes.
If the meter still indicates a “dry” condition, the floor is ready for covering. Tests should
be made at several points, especially when the slab is thick (4” or more) and air
circulation is poor. Make tests only in newly drilled holes.
Even readings in the “wet” range can indicate relatively low moisture content in Concrete.
For example, readings in the “68 to 77” range indicate approximately 2% to 4% moisture
content.
When evaluating a slab for readiness, always consider its age, thickness, whether the
slab is on grade or suspended, whether a vapor barrier is present and the drainage
condition of the ground.
MEASURING RH IN CONCRETE SLABS IN ACCORDANCE WITH ASTM F2170:
Navigator Pro can be used to measure the RH in a concrete slab in accordance with the ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs.
Basic Test Procedure:
Drill 5/8-inch hole in concrete to the appropriate depth and remove debris from the holes.
Insert a CS-2 concrete sleeve into the hole and plug the sleeve with the cap that is provided
with each sleeve.
Wait approximately 72 hours.
Remove protective cap from the concrete sleeve and insert the RH/T-S3 humidity sensor into
the hole. Wait approximately 1hr to allow the sensor to acclimate to the RH in the hole.
Connect one end of the RH/T-C1 cable to the top of meter and the other end to the exposed
end of the sensor. Take a RH reading using the RH/TEMP mode of Navigator Pro as
described on pages 10 and 17. This reading is the RH of the concrete slab.
For a complete explanation of the ASTM F2170- standard, please visit www.ASTM.org or
contact Delmhorst Instrument.
TESTING INSULATION:
Set the meter scale for PLASTER as described in the Create/Modify a Job section on page
11.
To take a reading, attach a 21-E electrode with 4” insulated contact pins to the meter. Push
the contact pins through the drywall into the insulation behind it.
Press the SELECT button and read the moisture content on the meter scale. The meter
displays the “relative” moisture level for two seconds.
TESTING DRYWALL
Set the meter scale for Sheetrock® as described in the Create/Modify a Job section on page
11.
To take a reading, push the contact pins into the Sheetrock® to their full penetration, if
possible.
Press the SELECT button and read the moisture content on the meter scale. The meter
Readings between 0.1% and 0.5% indicate a sufficiently dry moisture level.
Readings between 0.5% and 1% indicate a borderline situation. Readings
greater than 1% indicate material that is too wet for painting or wallpaper. A
reading above 1% also indicates enough moisture present to allow mold growth
to occur but only if other factors are also present such as a high RH level and
Store your meter in a clean, dry place. The protective carrying case provided is an ideal
storage place when the meter is not in use. If the meter has been left in a hot or cold
environment overnight or for an extended period, the calibration of the pin less mode may
be adversely affected. Under these conditions, allow the meter to acclimate to the
temperature conditions in which it will be used for minimum 1-2 hours, or as long as
possible.
Clean the meter with any biodegradable cleaner. Use the cleaner sparingly and on
external parts only. Keep cleaner out of the external connector.
Remove the battery if the meter will not to be used for one month or longer.
Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees the Navigator Pro
meter for one year from date of purchase and any optional electrodes against defects in material
or workmanship for 90 days. If, within the warranty period of the Model Navigator Pro, you find
any defect in material or workmanship, return the meter following the instructions in the “Service
for Your Meter” section. This warranty does not cover abuse, alteration, misuse, damage during
shipment, improper service, unauthorized or unreasonable use of the meter or electrodes. This
warranty does not cover batteries, pin assemblies, or pins. If the meter or any optional electrodes
have been tampered with, the warranty shall be void. At our option, we may replace or repair the
meter.
Delmhorst shall not be liable for incidental or consequential damages for the breach of any
express or implied warranty with respect to this product or its calibration. With proper care and
maintenance the meter should stay in calibration; follow the instructions in the “Care of Your Meter” section.
UNDER NO CIRCUMSTANCES SHALL DELMHORST BE LIABLE FOR ANY INCIDENTAL,
INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHATSOEVER,
INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR DOWNTIME ARISING OUT OF OR
RELATED IN ANY RESPECT TO ITS METERS OR ELECTRODES AND NO OTHER
WARRANTY, WRITTEN, ORAL OR IMPLIED APPLIES. DELMHORST SHALL IN NO EVENT
BE LIABLE FOR ANY BREACH OF WARRANTY OR DEFECT IN THIS PRODUCT THAT
EXCEEDS THE AMOUNT OF PURCHASE OF THIS PRODUCT.
The express warranty set forth above constitutes the entire warranty with respect to Delmhorst
meters and electrodes and no other warranty, written, oral, or implied applies. This warranty is
personal to the customer purchasing the product and is not transferable.