Delmhorst J-2000/PKG User manual

J-2000
o w n e r ’ s m a n u a l
W H E N A C C U R A C Y I S T H E P O I N T.
®
TM
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
2 J-2000 Features
3 Before You Begin
3 Check Calibration
4 Set Species
5 Species Code Chart
6 Set Temperature
7 Set Pin Calibration
7 Taking a Reading
8 Information About Your Readings
8 To Check Accumulated Readings
8 To Reset Meter
9 Care of Your Meter
10 Service For Your Meter
11 Warranty
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
^
J-2000 FEATURES
hResistance technology recognized worldwide as the most
accurate method for measuring wood MC
h6% to 40% MC wood (Douglas Fir ref) h6% to 60% MC wood (J-2000/X) hAverages up to 100 accumulated readings hUser-selectable corrections for 48 species hBuilt-in temperature compensation (F/C) hProven microcontroller circuit hEasy one-hand operation hIncludes (1) 9-Volt Battery hIncludes sturdy carrying case hOne-year warranty
#2497A-100 contact pins with 5/16” penetration
Temperature Key
Read Key
Calibration Check Key
#
Species Key
%
Digital
Readout
&
Connector for
External
Electrode
$
@
!
D E L M H O R S T J - 2 0 0 0
2
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
BEFORE YOU BEGIN
Key Functions
! READ KEY - Press to read the %MC.
@ CALIBRATION CHECK KEY - This key,
(when pressed with the read key) checks the meter calibration. It also displays the number of readings in memory (up to 100), the aver­age, and the highest stored reading. It also clears the memory.
# SPECIES KEY - Press to select the species
code for the wood you are testing. Species are numbered from 1 to 48 and are listed on the Species Code Chart on page 5. To scroll for­ward through the species codes keep the species key pressed. To scroll backward press the species key, release it and immediately press the temperature key.
$ TEMPERATURE KEY - Press to set the wood
temperature. Press and immediately press the Calibration Check the temperature key
@ to
toggle between (F and C). To increase the tem­perature setting keep the temperature key pressed. To decrease the temperature, press the temperature key, release it and immediate­ly press the species key.
CHECK CALIBRATION
Press the calibration check key @ and read key ! simul­taneously. Meter is in calibration if it displays 12% (+ or - 0.2).
If you check the calibration and the meter does not display 12% it is likely an indication of a low battery. If this occurs, replace the battery immediately with a new EverReady or Duracell brand 9V. Continued use with a low battery may cause the meter to go out of calibration. If you have a fresh battery and the instrument still does not indicate a proper calibration, return it to DELMHORST for service. See Service for your Meter section.
3
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
SET SPECIES
The J-2000 defaults to Species Code #1 - Douglas Fir - the USDA standard and basis for all Delmhorst calibrations. Because the electrical characteristics of different species vary, all species read differently at the same moisture con­tent. For this reason you need to adjust for species. If you are working with a species other than Douglas Fir, set the species code using the species key
#, and the meter will make the
necessary corrections.
hTo change species press the species key
#. The meter will
display the current species code for one second. Refer to the Species Code Chart on page 5. Call our customer ser­vice team at 877-DELMHORST (335-6467) or e-mail info@delmhorst.com for assistance with any species or wood-based material that is not included in the chart. It is always helpful if you have the scientific name as well as any common names for the species.
4
When the battery is removed and then reconnected, the meter displays its software version for one second and then turns itself off. After replacing the battery, you must reset the meter as described in Resetting the Meter section.
A hard Reset is required if, after changing the battery, the display is frozen. This is sometimes caused by the interrup­tion of contact between the battery and battery lead wire. Resolve this as follows: Disconnect the battery. Press and hold the Read key for 15 seconds. Release the Read key. Press and hold the Check key for 15 seconds. Release the Check key. Connect a fresh battery to the lead wire in a sin­gle action, making sure to align the poles properly and without interrupting contact. If the display remains frozen, repeat the procedure. If this procedure does not solve the problem, refer to the Service for Your Meter section.
Meter Default Settings
Species - Douglas Fir Temperature - 70ºF Pin/Electrode - 4-pin (non-insulated) Each of these parameters is programmed into the meter and is user-selectable. Proper setting of each will insure the most accurate readings.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
Species Code Chart
CODE / SPECIES CODE / SPECIES
1 Fir, Douglas 25 Magnolia 2 Pine, Southern 26 Mahogany, African (also Khaya) 3 SPF 27 Mahogany, Honduras 4 Alder 28 Mahogany, Philippine 5 Apitong 29 Maple, Hard/Soft 6 Aspen 30 Meranti, Dark Red 7 Ash, White 31 Oak, Red 8 Basswood 32 Oak, White 9 Birch 33 Pecan 10 Cedar, Eastern Red 34 Pine, Longleaf 11 Cedar, Incense 35 Pine, Ponderosa 12 Cherr y 36 Pine, Shortleaf 13 Cottonwood 37 Pine, Sugar 14 Cypress 38 Pine, White 15 Elm, American 39 Poplar, Yellow 16 Fir, Red 40 Ramin 17 Fir, White 41 Radiata Pine 18 Gum, Black 42 Redwood 19 Gum, Red 43 Spruce, Sitka 20 Hemlock, Western 44 SPF, COFI* 21 Hackberr y 45 Teak 22 Hickory 46 Virola 23 Keruing 47 Walnut, Black 24 Larch 48 Western Hemlock - COFI*
*Species and temperature correction data for both Western Hemlock­COFI (code #48) and SPF-COFI (code #44) were developed by COFI.
When comparing readings between the model RDM-2/COFI or the RDM-2S/COFI, used with type 26-E electrode with insulated pins, and the J-2000, be sure both meters are set to 2-pin electrode (insulated pins).
5
hTo scroll forward through the species list hold the species
key
# while the current species code is displayed and
scroll to the species number desired.
hTo scroll backward through the species list, press and
release the species key
#. Within one second, press and
hold the temperature key
$. Continue to hold the tem-
perature button
$ and the species number will decrease.
hWhen scrolling in either direction, release the key to stop
at your desired species.
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
SET TEMPERATURE
The J-2000 defaults to a temperature of 70ºF. As wood temperature increases, its electrical resistance decreases and indicated moisture content rises. Lower wood temperatures result in lower indicated moisture content. A correction is necessary if the wood temperature is outside the range of 50ºF (10ºC) to 90ºF (32ºC). Set the temperature accordingly and the meter will make the correction.
hTo change temperature press and release the temperature
key
$. The meter will display the current temperature for
one second.
hTo scroll forward through the temperature settings, press
and hold the temperature key
$ while the current tem-
perature is displayed.
hTo scroll backward press and release the temperature
key
$
.
Within one second, press and hold the species
key
#
.
Continue to hold the species key
# and
the temperature will decrease.
hWhen scrolling in either direction, release the button to
stop at the desired temperature.
Set Temperature Mode
hTo change between Fahrenheit and Celsius modes press the
temperature key
$.
hPress the calibration check key
@ within one second and
release when you are in the desired mode.
hThe meter will display the current temperature setting in
the new mode and will wait one more second until shutting off so that you may change the temperature value as described above.
If the meter is in Fahrenheit mode, the letter “F ” will display in the left-hand corner. If it is in Celsius mode, no letter will appear in the display.
In the Fahrenheit mode, the temperature will change in increments of 5ºF. In Celsius, the temperature will change in increments of either 2ºC or 3ºC depending on its conversion from Fahrenheit.
In the Fahrenheit mode, the temperature value will display in whole numbers. In the Celsius mode, positive values will display in whole numbers; negative values will display with a decimal point and a “minus” sign in the left-hand corner. (i.e.: -17.0)
6
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
SET PIN CALIBRATION
The basic factory calibration of the J-2000 is for use with non-insulated pins. Insulated pins read lower than non-insu­lated ones. The difference is small below 10% MC but increases as the moisture content increases above 10%. When using an electrode with insulated pins, such as the 26­ES hammer electrode, you can change the calibration to compensate for this difference.
hTo change the pin setting, press and release the species
key
#, then press the calibration check key @ within
one second.
hThe meter will display the current pin calibration as either
222 for insulated or 444 for non-insulated pins.
hIf you continue to hold the calibration check key
@, the
meter will toggle between 222 and 444.
TAKING A READING
hRemove the protective cover to expose the pins. Check
that the contact pins
^ are firmly hand tightened.
hTo take a reading, align the contact pins
^ parallel to
the grain and push them to their full penetration into the wood, if possible. Insulated pins read only at the tip and can be driven to the desired depth.
hPress the read key
! and read the moisture content on
the meter scale. The meter displays the %MC for two seconds.
hTo add a reading to the sum of all the previously stored
readings, release the read key
! within 2 seconds.
The non-insulated contact pins on the top of the meter pene­trate max 5/16in. and may be used on wood up to 1-1/2 to 2in. thick. Push the pins into the wood to their full penetration for best accuracy. For thicker wood and hardwoods over 4/4, use the 26-ES hammer electrode with insulated pins. These pins (no. 496), may be used on wood up to 5-6in. thick. Connect the electrode to the input connector on the top of the meter
&. Contact our customer service team for more infor-
mation on other available pins for your application. Insulated pins offer the advantage of taking measurements
at various depths since the reading is made at the point in the wood where only the non-insulated tips of the pins make contact. This is especially useful when drying lumber since reliable shell and core readings are essential to producing high quality lumber.
See the FAQ section of our website for helpful application info. www.delmhorst.com
7
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
INFORMATION ABOUT YOUR READINGS
Readings below 6% will be displayed as a numeric value, (-##.#), but will not be added to the accumulated readings in memory. Readings below 6% due to temperature and species adjustments will be shown as a numeric value with no minus sign. These readings will be added to the accumulated total in memory and included in the statistical calculations.
Readings above 40% are always displayed as 999 and are not added to the memory.
The meter will accumulate up to 100 readings. After all 100 readings are stored it will not add new readings until the memory has been cleared. It will also continue to display the average of all 100 readings as a reminder that the mem­ory is full.
When taking and storing readings for a specific wood species, be sure to clear the meter's memory before moving on to the next species if you do not want to group all of the readings together.
TO CHECK ACCUMULATED READINGS
This feature allows you to view the total number of all accumulated readings, the average of those readings, and the highest stored reading.
hTo view the readings press and release the calibration
check key
@. The meter displays the number of accumulat-
ed readings for one second, then the average of those read­ings for two seconds. Then it displays the highest stored reading for two seconds. The total cycle time is five sec­onds.
hTo clear the memory press and hold the calibration check
key
@ down for 5 seconds. All accumulated readings will
be erased and the meter will display “0”.
TO RESET METER
hPress and release the calibration check key @.
hWithin one second press the species key
#.
hThe meter will reset itself and display “170” to indicate the
meter is reset to default: Species #1 (Douglas Fir) at 70ºF, followed by 444 (pin setting). All of the readings in memory will be cleared.
8
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
CARE OF YOUR METER
To keep your meter in good working order:
hStore your meter in a clean, dry place. The protective
carrying case provided is an ideal storage place when the meter is not in use.
hChange the 9-Volt battery as needed. Use only EverReady
or Duracell brand batteries. Continued use with a low bat­tery may cause the meter to go out of calibration.
hChange contact pins as needed. Keep contact pins hand
tightened.
hClean the meter and contact pins with any biodegradable
cleaner. Use the cleaner sparingly and on external parts only. Keep cleaner out of the external connector
&.
hRemove the battery if the meter will not be used for one
month or longer.
9
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
WARRANTY
Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its J-2000 meter for one year from date of purchase and any optional electrodes against defects in material or workmanship for 90 days. If, within the warranty period, you find any defect in material or workmanship return the meter following the instructions in the Service for Your Meter section. This limited warranty does not cover abuse, alteration, misuse, damage during shipment, improper service, unauthorized or unreasonable use of the meter or electrodes. This warranty does not cover batteries or contact pins. If the meter or any optional electrodes have been tam­pered with, the warranty shall be void. At our option we may replace or repair the meter.
Delmhorst shall not be liable for incidental or consequential damages for the breach of any express or implied warranty with respect to this product or its calibration. With proper care and maintenance the meter should stay in calibration; follow the instructions in the Care of Your Meter section.
UNDER NO CIRCUMSTANCES SHALL DELMHORST BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY TYPE WHAT­SOEVER, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS OR DOWNTIME ARISING OUT OF OR RELAT­ED IN ANY RESPECT TO ITS METERS OR ELEC­TRODES AND NO OTHER WARRANTY, WRITTEN, ORAL OR IMPLIED APPLIES. DELMHORST SHALL IN NO EVENT BE LIABLE FOR ANY BREACH OF WARRANTY OR DEFECT IN THIS PRODUCT THAT EXCEEDS THE AMOUNT OF PURCHASE OF THIS PRODUCT.
The express warranty set forth above constitutes the entire warranty with respect to Delmhorst meters and electrodes and no other warranty, written, oral, or implied applies. This warranty is personal to the customer purchasing the product and is not transferable.
11
Find Quality Products Online at: sales@GlobalTestSupply.com
www.GlobalTestSupply.com
®
TM
For more than 65 years Delmhorst Instrument
has been the leading manufacturer of high quality,
US-made moisture meters and thermo-hygrometers.
Today we offer a wide range of meters for
applications including water damage restoration,
construction, flooring, lumber/woodworking,
paper, and agriculture.