All rights reserved. Specifications in this manual are subject to change without notice.
Originated in the USA. Any other trademarks appearing in this manual are the property of their respective companies.
Open Source Code
Certain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU
General Public License (GPL), GNU Lesser General Public License (LGPL), or other Open Source Licenses. The Open Source code
used can be found at this site:
http://www.arubanetworks.com/open_source
Legal Notice
The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate other vendors' VPN
client devices constitutes complete acceptance of liability by that individual or corporation for this action and indemnifies, in full, Aruba
Networks, Inc. from any and all legal actions that might be taken against it with respect to infringement of copyright on behalf of those
vendors.
Dell PowerConnect W-620 Controller | Installation Guide0510751-MU-01 | July 2010
z An overview of the contents of this manual
z A list of related documentation for further reading
z Aruba support and service information
General Overview
z Chapter 1, “About the W-620 Controller” on page7 provides a detailed hardware overview of the Aruba 620.
z Chapter 2, “W-620 Series Installation” on page13 provides rack mounting and installation instructions.
z Appendix A, “Specifications, Safety, & Compliance” on page15 includes product technical specifications,
safety, and regulatory compliance information.
Related Documentation
The following documentation are referred to in this guide and are considered components of the complete
documentation set needed for a successful installation and management of an Dell Controller.
z
Dell PowerConnect ArubaOS 5.0 Quick Start Guide
z
Dell PowerConnect ArubaOS 5.0 User Guide
z
Dell PowerConnect ArubaOS 5.0 Command Line Reference
Contacting Dell
Web Site Support
Main Sitewww.dell.com
Support Sitesupport.dell.com
Documentationsupport.dell.com/manuals
The Dell PowerConnect W-620 Series Controller is an enterprise-class, wireless LAN controller. This controller
connects, controls, and integrates wireless Access Points (APs) and Air Monitors (AMs) into a wired LAN system.
The W-620 Series is capable of supporting up to 8 external, campus connected APs.
Minimum Software Requirements
The W-620 Series Controller requires ArubaOS 5.0.2 or later.
Note: The master controller, its redundant master controller, and all of its local controllers must run on the same code of ArubaOS.
Once you upgrade your network and install an W-620 Series Controller into your network, verify that the software version on your
controller matches the rest of your network.
z W-620 Series Controller
z AC Power Cord (country-specific)
z Flat Serial Cable (RJ-45)
z Rubber Feet (for table top deployments)
z Serial Console Port Adaptor (RJ-45 to DB9)
z
Dell PowerConnect ArubaOS Quick Start Guide
z End User License Agreement (EULA)
z Safety, Environmental, and Regulatory Information (SERI) document
z Warranty and Support Information (WSI) document
Note: Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the
original packing materials. Use these materials to repack and return the unit to the supplier if needed.
The W-620 Series is equipped with one ExpressCard slot, which can be used with an EVDO device.
Port LEDs
In non-rack deployments, the W-620 Series is placed with the front facing out. This allows the cables to be
hidden and create a more aesthetically pleasing look. Therefore, a set of LEDs displaying link activity on the ports
is placed on this side. For information about the behavior of these LEDs, see Table 3.
8 | About the W-620 ControllerDell PowerConnect W-620 Controller | Installation Guide
Rear View
10/100/1000Base-T
Gigabit Ethernet Port
10/100Base-T
Ethernet Ports
USB port
Media Eject Button
Serial Console Port
AC Power Socket
1000Base-T Gigabit
Ethernet Port
RJ-45 Female
Pin-Out
Signal Name
1
2
3
4
5
6
7
8
BI_DC+
BI_DC-
BI_DD+
BI_DD-
BI_DA+
BI_DABI_DB+
BI_DB-
Function
Bi-directional pair +C
Bi-directional pair -C
Bi-directional pair +D
Bi-directional pair -D
Bi-directional pair +A
Bi-directional pair -A
Bi-directional pair +B
Bi-directional pair -B
Figure 2 W-620 Series Series Rear View
AC Power Socket
The W-620 Series supports integrated AC powering and the AC power socket on the rear of the unit is for use
with an AC power cord (country-specific). Refer to Appendix A, “Specifications, Safety, & Compliance” on
page15 for power specification details.
10/100BaseT Ethernet Ports
There are eight 10/100BaseT Ethernet ports on the W-620 Series. Ports 0 through 3 support Power over Ethernet
(PoE). Ports 4 through 7 do not support PoE and do not have a PoE LED. Instead, they have an LED labeled 100,
which indicates interface speed. For information about LED behavior, see Table 3.
10/100/1000Base-T Gigabit Ethernet Port
There is one 10/100/1000Base-T Gigabit Ethernet (RJ-45) port on the W-620 Series. Gigabit Ethernet uses all
eight wires and each pair is used in a bi-directional fashion, meaning the same pairs are used for both data
transmission and reception. Figure 3 illustrates the CAT-5 pin-out found on an RJ-45 connector. The CAT-5 pinout pairs the following pins on a 10/100/1000Base-T Gigabit Ethernet port: 1/2, 3/6, 4/5, and 7/8.
A serial console port (see Figure 4) is provided for connection to a terminal, allowing for direct local management.
The port’s RJ-45 female connector accepts an RS-232 serial cable with a male connector.
Figure 4 Serial Console Port Pin-Out
Communication settings for the serial port are indicated in Table 1.
Table 1 Console Terminal Settings
Baud RateData BitsParityStop BitsFlow Control
96008None1None
10 | About the W-620 ControllerDell PowerConnect W-620 Controller | Installation Guide
Caution: Do not connect an AP to the serial console port. The serial console port is compatible only with RS-232 devices. NonRS-232 devices, such as APs, are not supported.
Serial Console Port Adaptor
A modular adaptor can be used to convert the RJ-45 (female) connector to a DB9 (male) connector. Refer to
Figure 5 for complete details.
Figure 5 RJ-45 (female) to DB9 (male) Modular Adaptor Conversion
USB Ports
The W-620 Series has one USB 2.0 interface. This interface allows the use of EVDO/HSPDA modem, flash or
disk storage devices, or a printer. For more information about configuring and using USB devices with the W-620
Series, see the ArubaOS User Guide.
Media Eject Button
The W-620 Series is equipped with a media eject button, which allows users to eject a storage device safely and
place the system in standby. When the button is pushed, the storage media device attached to the controller via
USB are unmounted. Printers and EVDO devices are unaffected.
Pushing the media eject button changes the state of the W-620 Series; the table below describes the states and
LED behaviors associated with use of the media eject button.
Table 2 Media Eject Button LED Behavior
Initial StateLED StateActionStatus LED Function
NAS Media
Operational
NAS Media
Unmounted
OperationalGreen-solidPress and hold media eject
Operating with NAS
Media un-mounted
StandbyRed-solidPress media eject buttonAmber-flashingController wake-upGreen-solid
Green-solidPress and hold media eject
button for 1 to 5 seconds only
Amber-solidPress and hold media eject
button for 1 to 5 seconds only
button for more than 5 seconds
only
Amber-solidPress and hold media eject
button for more than 5 seconds
only
Amber-flashingUn-mount NAS mediaAmber-solid
Amber-flashingMount attached NAS
device, and return to fully
functional operation
Red-flashingController goes into
Standby
Red-flashingController goes into
Standby
LED Action
Completed
Green-solid
Red-solid
Red-solid
LED Status Indicators
Table 3 W-620 Series LED Status Indicators
LEDLabelFunctionIndicatorStatus
PowerPOWERInput Power Status IndicatorOn (Solid Green)Power on
OffNo Power
StatusSTATUSModule Status IndicatorOn (Solid Green)Device is operational
On (Solid Red) Device failed or is in Standby
On (Solid Amber)Device is loading software
OffNo power
10/100/1000Base-T
Port
10/100Base-T Ports LINK/ACTLink/Activity Status IndicatorOn (Solid Green)Link has been established
LNK/ACTLink/Activity Status IndicatorOn (Solid Green)Link has been established
On (Flashing Green)Port is transmitting or receiving
data
Off No link on port
1000Interface SpeedOn (Solid Green)1000 Mbps
Off10/100 Mbps
On (Flashing Green)Port is transmitting or receiving
PoE PoE Status IndicatorOn (Solid Green)PoE is being provided
Chapter 1
On (Solid Amber)The attached device has
requested PoE, but PoE is not
being provided by the port
OffPoE is not being provided
100 Interface SpeedOn (Solid Green)100 Mbps
Off10 Mbps
12 | About the W-620 ControllerDell PowerConnect W-620 Controller | Installation Guide
Chapter 2
W-620 Series Installation
The following tools and equipment are required for installation of a W-620 Series controller.
z AC Power Cord (country-specific)
z Any ethernet cables required for your deployment
Physical Installation
Tabletop Deployment
To deploy an W-620 Series controller on a flat surface, such as a tabletop:
1. Insert the four rubber mounting feet to the bottom of the unit.
2. Place the unit on a hard flat surface.
Initial Setup and Network Connectivity
Once the physical installation is complete, run the initial setup on the controller to configure the IP address and
other basic system information. For complete details and instructions, refer to the Dell PowerConnectArubaOS Quick Start Guide for the software version installed on your controller.
z Height 1.75˝ (45 mm)
z Width 12.6˝ (320 mm)
z Depth 6.8˝ (173 mm)
Power Management Specifications
z AC Input Voltage: 100-240 V, Universal Input
z AC Input Frequency: 50-60 Hz
z Maximum power consumption: 115 Watts
Appendix A
Specifications, Safety, &
Compliance
z Power over Ethernet total capacity: 78 Watts
z Power over Ethernet capacity per port: 19.5 Watts
Operating Specifications
z Operating Temperature Range: 0°C to 40°C (32°F to 104°F)
z Operating Humidity Range: 5% to 95% (RH), non-condensing
Storage Specifications
z Storage Temperature Range: 0°C to 50°C (32°F to 122°F)
z Storage Humidity Range: 5% to 95% (RH), non-condensing
Safety and Regulatory Compliance
Dell provides a multi-language document containing country specific restrictions and additional safety and
regulatory information for all Dell hardware products. The Dell PowerConnect W-Series Safety, Environmental, and Regulatory Information document is included with this product.
CLASS 1
LASER PRODUCT
Caution: Use of controls or adjustments of performance or procedures other than those specified in this manual may result
in hazardous radiation exposure.
This product complies with 21 CFR Chapter 1, Subchapter J, Part 1040.10, and IEC 60825-1: 1993, A1: 1997, A2:
2001, IEC 60825-2: 2000.
For continued compliance with the above laser safety standards, only approved Class 1 modules from our
approved vendors should be installed in Aruba products.
FCC Class B Device
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
z Reorient or relocate the receiving antenna.
z Increase the separation between the equipment and receiver.
z Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
z Consult the dealer or an experienced radio/ TV technician for help (we can modify this to advise to seek help
of the professional installer).
For a complete list of Country Specific Regulations please speak with your Dell Representative .
NOM Information (Mexico Only)
The following information is provided on the device described in this document in compliance with the
requirements of the official Mexican standards (NOM):
Importer: Dell Inc. de Mexico, S.A. de C.V.
Paseo de la Reforma 2620-11° Piso
Col. Lomas Atlas
11950 Mexico, D.F.
Model Number: 620
z Supply Voltage: 100-240 V AC
z Frequency: 47-63 Hz
z Current consumption: 1.8 A
Additional Regulatory Compliance and Safety
z EN 55022 Class B
z EN 55024
z IEC/EN 60950
z CE Marking
z cTUVus Marked
z CB Scheme Certified
Proper Disposal of Dell Equipment
For the most current information on Global Environmental Compliance and Dell products please refer to the
Dell PowerConnect W-Series Safety, Environmental, and Regulatory Information document is included with this
product or see our website at www.dell.com.
Dell products also comply with the EU Restriction of Hazardous Substances Directive
2002/95/EC (RoHS). EU RoHS restricts the use of specific hazardous materials in the
manufacture of electrical and electronic equipment. Specifically, restricted materials
under the RoHS Directive are Lead (including Solder used in printed circuit assemblies), Cadmium, Mercury,
Hexavalent Chromium, and Bromine. Some Dell products are subject to the exemptions listed in RoHS Directive
Annex 7 (Lead in solder used in printed circuit assemblies). Products and packaging will be marked with the
“RoHS” label shown at the left indicating conformance to this Directive.
Alle Rechte vorbehalten. Spezifikationen in diesem Handbuch können ohne Ankündigung geändert werden.
Hergestellt in den USA. Alle anderen Marken, die in diesem Handbuch erwähnt werden, sind das Eigentum der jeweiligen
Unternehmen.
Open Source Code
Bestimmte Aruba-Produkte enthalten Open Source-Softwarecode, der von Drittanbietern entwickelt wurde, darunter Softwarecode
gemäß GNU General Public License (GPL), GNU Lesser General Public License (LGPL) oder anderen Open Source-Lizenzen.
Den Open Source Code finden Sie auf dieser Website:
http://www.arubanetworks.com/open_source
Rechtliche Hinweise
Die Verwendung von Switching-Plattformen und Software von Aruba Networks, Inc. durch Einzelpersonen oder Unternehmen zur
Terminierung von VPN-Client-Geräten anderer Hersteller stellt die vollständige Anerkennung der Haftbarkeit dieser Einzelpersonen oder
dieses Unternehmens für diese Aktion dar und enthebt Aruba Networks, Inc. zur Gänze aller rechtlichen Maßnahmen, die bezüglich der
Verletzung des Urheberrechts im Namen dieser Hersteller ergriffen werden.
Dell PowerConnect W-620 Controller | Installationsanleitung0510751-MU-01 | Juli 2010
Dieses Vorwort enthält die folgenden Informationen:
z Überblick über den Inhalt des vorliegenden Handbuchs
z Liste verwandter Dokumentationen
z Hinweise zum Support und Service von Aruba
Allgemeine Übersicht
z Kapitel 1, „Der W-620 Controller“ auf Seite 7 enthält einen ausführlichen Überblick über die Hardware
des Aruba 620
z Kapitel 2, „W-620 Serie - Installation“ auf Seite 13 bietet Informationen zur Rack-Montage und Installation
z Anhang A, „Technische Daten, Sicherheit und Konformität“ auf Seite 15 enthält technische Daten und
Informationen zur Sicherheit und Richtlinienkonformität
Verwandte Dokumentation
Die folgenden Handbücher und Anleitungen werden im vorliegenden Handbuch als Referenz angegeben und
gelten als Bestandteile der vollständigen Dokumentation, die für die erfolgreiche Bereitstellung und Verwaltung
eines Dell Controllers erforderlich ist.
z
Dell PowerConnect ArubaOS 5.0 Quick Start Guide
z
Dell PowerConnect ArubaOS 5.0 User Guide
z
Dell PowerConnect ArubaOS 5.0 Command Line Reference
Der Dell PowerConnect W-620 Serie Controller ist ein Wireless-LAN-Controller für Unternehmen. Dieser
Controller kann drahtlose Access Points (APs) und Air Monitors (AMs) verbinden, steuern und in ein
kabelgebundenes LAN-System integrieren. Der W-620 Serie unterstützt bis zu 8 externe, verbundene APs auf
einem Gelände.
Mindestvoraussetzungen für die Software
Für den W-620 Serie Controller ist ArubaOS 5.0.2 oder eine neuere Version erforderlich.
Hinweis: Der Mastercontroller, sein redundanter Mastercontroller und alle lokalen Controller müssen dieselbe Version von
ArubaOS verwenden. Wenn Sie Ihr Netzwerk aktualisieren und einen W-620 Serie Controller im Netzwerk installieren,
vergewissern Sie sich, dass die Softwareversion des Controllers zum restlichen Netzwerk passt.
z W-620 Serie Controller
z Netzkabel (länderspezifisch)
z Serielles Flachbandkabel (RJ-45)
z Gummifüße (für die Aufstellung auf Tischplatten)
z Adapter für die serielle Konsolenschnittstelle (RJ-45 zu DB9)
z
Dell PowerConnect ArubaOS Quick Start Guide
z Endbenutzerlizenzvereinbarung (EULA)
z Safety, Environmental, and Regulatory Information (SERI)-Dokument
z Warranty and Support Information (WSI)-Dokument
Hinweis: Wenden Sie sich an Ihren Händler, wenn Teile fehlen oder beschädigt sind oder wenn Sie falsche Teile erhalten haben.
Bewahren Sie den Karton einschließlich der Original-Verpackungsmaterialien nach Möglichkeit auf. Verwenden Sie diese
Materialien, um das Produkt bei Bedarf zu verpacken und zum Händler zurückzubringen.
Der W-620 Serie ist mit einem ExpressCard-Steckplatz ausgestattet, der für ein EVDO-Gerät verwendet
werden kann.
Anschluss-LEDs
Bei Aufstellungen ohne Rack wird der W-620 Serie mit der Vorderseite nach vorne aufgestellt. Auf diese Weise
können die Kabel für einen optisch besseren Eindruck verborgen werden. Deshalb befinden sich die LEDs, die
Informationen zur Verbindungsaktivität an den Ports anzeigen, auf dieser Seite. Informationen zu diesen LEDs
finden Sie in Tabelle 3.
8 | Der W-620 ControllerDell PowerConnect W-620 Controller | Installationsanleitung
Rückansicht
10/100/1000Base-T
Gigabit-Ethernet-Port
10/100Base-TEthernet-Ports
USB-Anschluss
Auswurftaste für Medien
Serielle Konsolenschnittstelle
Netzstromanschluss
1000Base-T Gigabit-
Ethernet-Port
RJ-45-Buchse
Pin-Belegung
Signalname
1
2
3
4
5
6
7
8
BI_DC+
BI_DC-
BI_DD+
BI_DD-
BI_DA+
BI_DABI_DB+
BI_DB-
Funktion
Bidirektionales Paar +C
Bidirektionales Paar -C
Bidirektionales Paar +D
Bidirektionales Paar -D
Bidirektionales Paar +A
Bidirektionales Paar -A
Bidirektionales Paar +B
Bidirektionales Paar -B
Abbildung 2 W-620 Serie Rückansicht
Netzstromanschluss
Der W-620 Serie unterstützt die integrierte Netzstromversorgung. An den Netzstromanschluss auf der Rückseite
des Geräts kann ein Netzkabel angeschlossen werden (länderspezifisch). Weitere Informationen zur
Stromversorgung finden Sie unter Anhang A, „Technische Daten, Sicherheit und Konformität“ auf Seite 15.
10/100BaseT-Ethernet-Ports
Es gibt acht 10/100BaseT-Ethernet-Anschlüsse am W-620 Serie. Die Ports 0 bis 3 unterstützen Power over
Ethernet (PoE). Die Ports 4 bis 7 unterstützen PoE nicht und haben keine PoE-LED. Stattdessen verfügen sie
über eine mit „100“ gekennzeichnete LED, die die Schnittstellengeschwindigkeit angibt. Informationen über die
Anzeigemuster der LEDs finden Sie in Tabelle 3.
10/100/1000Base-T-Gigabit-Ethernet-Port
Der W-620 Serie verfügt über einen 10/100/1000Base-T-Gigabit-Ethernet-Port (RJ-45). Gigabit-Ethernet nutzt
alle acht Leitungen und jedes Paar wird bidirektional verwendet, sodass dieselben Paare sowohl für die
Datenübertragung als auch für den Empfang verwendet werden. Abbildung 3 zeigt die CAT-5-Pin-Belegung für
einen RJ-45-Anschluss. Die CAT-5-Pin-Belegung fasst jeweils die folgenden Pins bei einem 10/100/1000Base-TGigabit-Ethernet-Anschluss zu Paaren zusammen: 1/2, 3/6, 4/5 und 7/8.
Abbildung 3 Pin-Belegung des Gigabit-Ethernet-Ports
Eine serielle Konsolenschnittstelle (siehe Abbildung 4) steht für den Anschluss an ein Terminal zur Verfügung,
um die direkte lokale Verwaltung zu ermöglichen. An die RJ-45-Buchse kann ein serielles Kabel (RS-232) mit
Stecker angeschlossen werden.
Kommunikationseinstellungen für den seriellen Anschluss sind in Tabelle 1 aufgeführt.
Tabelle 1 Konsolenterminaleinstellungen
BaudrateDatenbitsParitätStoppbitsFlusssteuerung
96008Keine1Keine
Vorsicht: Schließen Sie keinen AP an die serielle Konsolenschnittstelle an. Die serielle Konsolenschnittstelle ist nur mit RS-232Geräten kompatibel. Andere Geräte als RS-232-Geräte, zum Beispiel APs, werden nicht unterstützt.
Adapter für die serielle Konsolenschnittstelle
Mit einem modularen Adapter kann die RJ-45-Buchse in einen DB9-Stecker umgewandelt werden.
Details können Sie Abbildung 5 entnehmen.
Abbildung 5 Umwandlung der RJ-45-Buchse zum DB-9-Stecker mit modularem Adapter
USB-Anschlüsse
Der W-620 Serie ist mit einem USB 2.0-Anschluss ausgestattet. Über diese Schnittstelle kann ein
10 | Der W-620 ControllerDell PowerConnect W-620 Controller | Installationsanleitung
Weitere Informationen zur Konfiguration und Verwendung von USB-Geräten mit dem W-620 Serie finden Sie
im ArubaOS User Guide.
EVDO/HSPDA-Modem, Flash- oder Festplattenspeichergerät oder Drucker angeschlossen werden.
Loading...
+ 208 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.