1: 简介........................................................................................................................................5
系统要求.................................................................................................................................................................................5
存储阵列简介........................................................................................................................................................................ 5
相关说明文件........................................................................................................................................................................ 6
2: 硬件安装................................................................................................................................. 7
规划存储配置 ........................................................................................................................................................................7
连接存储阵列 ........................................................................................................................................................................7
存储阵列布线.........................................................................................................................................................................7
一致配置与非一致配置........................................................................................................................................................8
RAID 控制器配置............................................................................................................................................................. 8
PowerVault MD3060e 扩展柜布线................................................................................................................................... 13
使用新的 PowerVault MD3060e 扩展柜进行扩展...................................................................................................15
3: 安装 MD Storage Manager.......................................................................................................17
安装主机总线适配器和驱动程序......................................................................................................................................17
图形化安装推荐.......................................................................................................................................................... 18
控制台安装 .......................................................................................................................................................................... 18
无提示安装 .......................................................................................................................................................................... 18
Windows 中进行无提示安装.................................................................................................................................. 18
Linux 中进行无提示安装......................................................................................................................................... 19
启用高级功能可选...................................................................................................................................................... 19
升级 PowerVault MD Storage Manager........................................................................................................................... 19
4: 安装后任务............................................................................................................................ 20
验证存储阵列查找..............................................................................................................................................................20
初始设置任务...................................................................................................................................................................... 20
5: 卸载 MD Storage Manager......................................................................................................22
Windows 中卸载 MD Storage Manager..................................................................................................................... 22
Windows Server GUI 版本卸载 MD Storage Manager.............................................................................................22
Windows Server Core 版本卸载 MD Storage Manager........................................................................................... 22
Linux 中卸载 MD Storage Manager............................................................................................................................ 23
6: 负载平衡............................................................................................................................... 24
负载平衡策略...................................................................................................................................................................... 24
带子集的轮询................................................................................................................................................................ 24
最少队列深度................................................................................................................................................................ 24
最少路径权重................................................................................................................................................................ 24
Linux 中设置负载平衡策略.......................................................................................................................................... 24
VMware 中设置负载平衡策略.....................................................................................................................................24
7: 获得帮助............................................................................................................................... 25
目录
3
联系 Dell............................................................................................................................................................................... 25
找到您的 Dell 系统服务标签 ............................................................................................................................................25
4
目录
1
简介
本指南提供关于部署 Dell PowerVault MD3460 存储阵列的信息。部署过程包括
硬件安装
Modular Disk Storage Manager (MD Storage Manager) 安装
初始系统配置
提供的其他信息包括系统要求、存储阵列组织和公用程序。
注: 有关产品说明文件的更多信息请参阅相关说明文件
MD Storage Manager 可让管理员配置和监测存储阵列以获得最佳可用性。PowerVault MD 系列资源介质随附的 MD Storage Manager 版本可用于管理 PowerVault MD3460 系列以及其他 PowerVault MD 系列存储阵列。MD Storage Manager 兼容 Microsoft Windows Linux 操作系统。
主题
系统要求
存储阵列简介
相关说明文件

系统要求

在安装和配置 PowerVault MD3460 系列硬件和软件之前请确保已安装支持的操作系统且满足最低系统要求。有关更多信息请参 阅 dell.com/powervaultmanuals 上的 Support Matrix支持值表
管理站要求
管理站使用 MDSM 来配置和管理跨网络的存储阵列。有关管理站的要求请参阅 dell.com/powervaultmanuals 上的 Dell PowerVault MD34xx/38xx Series Support MatrixDell PowerVault MD34xx/38xx 系列支持值表)。

存储阵列简介

包含通过 RAID 控制器模块访问的物理磁盘的机柜称为存储阵列。存储阵列包括硬盘柜内容纳的各种硬件组件例如物理硬盘、RAID 控制器模块、风扇以及电源设备。
连接至存储阵列的一台或多台主机服务器可访问存储阵列上的数据。您还可以在主机和存储阵列之间建立多条物理路径以便当任 意单一路径丢失时例如由于主机服务器端口故障仍可访问存储阵列中的数据。
存储阵列由运行在以下对象上的 MD Storage Manager 管理
主机服务器 — 在主机服务器系统上,MD Storage Manager 与存储阵列使用带内或带外连接传递管理请求和事件信息。
管理站 — 在管理站上,MD Storage Manager 通过存储阵列管理端口的以太网连接或通过主机服务器的以太网连接与存储阵列 进行通信。以太网连接可在管理站和使用阵列连接的存储阵列间传递管理信息。
使用 MD Storage Manager可将存储阵列中的物理磁盘配置成称为磁盘组和动态磁盘池 (DDP) 的逻辑组件然后将磁盘组分成虚拟 磁盘。磁盘组将采用存储阵列的未配置容量进行创建。虚拟磁盘则会采用磁盘组的可用容量进行创建。
未配置的容量包括尚未分配给磁盘组或 DDP 的物理磁盘。当使用未配置的容量创建虚拟磁盘时会自动创建一个磁盘组。如果删除 了磁盘组中唯一的虚拟磁盘则也会删除该磁盘组。可用容量是指磁盘组中尚未分配给任何虚拟磁盘的空间。
数据采用 RAID 技术写入存储阵列中的物理磁盘。RAID 级别定义了数据写入物理磁盘的方式。RAID 级别不同提供的可访问性、一 致性和容量级别也不同。您可以为存储阵列上的每个磁盘组和虚拟磁盘设置指定的 RAID 级别。有关在存储解决方案中使用 RAID 和 管理数据的更多信息请参阅 dell.com/powervaultmanuals 上的 Dell PowerVault MD Series Storage Arrays Administrator's Guide Dell PowerVault MD 系列存储阵列管理员指南
简介
5

相关说明文件

注: 有关所有 PowerVault 说明文件请访问 dell.com/powervaultmanuals,然后输入系统服务标签以获取您的系统说明文
件。
注: 有关所有 Dell OpenManage 文档请访问 dell.com/openmanagemanuals。
注: 有关所有存储控制器说明文件请访问 dell.com/storagecontrollermanuals。
您的产品说明文件包括
Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide(Dell PowerVault MD3460/3860i/3860f
用入门指南
Dell PowerVault MD3460 Storage Arrays Owner 的信息并介绍如何排除系统故障以及如何安装或更换系统组件。
Rack Installation Instructions机架安装说明— 介绍如何将系统安装到机架中。此说明文件也将随附在机架解决方案中。
Dell PowerVault MD Series Storage Arrays Administrator's Guide(Dell PowerVault MD 用 MDSM GUI 配置和管理系统的信息。
Dell PowerVault MD 34XX/38XX Series Storage Arrays CLI Guide 介绍有关使用 MDSM CLI 配置和管理系统的信息。
Dell PowerVault MD3460 Storage Arrays Deployment Guide(Dell PowerVault MD3460 构中部署存储系统的信息。
Dell PowerVault MD Series Support Matrix(Dell PowerVault MD 息。
— 提供系统功能设置系统和技术规范的概述。您的系统也随附有此说明文件。
s Manual(Dell PowerVault MD3460
存储阵列用户手册
系列存储阵列管理员指南
Dell PowerVault MD 34XX/38XX
存储阵列部署指南
系列支持值表
提供有关存储阵列软件和硬件兼容性值表的信
提供有关系统功能
系列存储阵列
— 提供有关在 SAN
存储阵列使
— 提供有关使
CLI
指南
6
简介

硬件安装

使用本指南之前请确保查阅以下指南中的说明
Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide(Dell PowerVault MD3460/3860i/3860f
用入门指南
Dell PowerVault MD Series Storage Arrays Administrator's Guide(Dell PowerVault MD 南提供有关设置存储解决方案之前必须了解的重要概念的信息。有关更多信息请参阅 dell.com/powervaultmanuals
Rack Installation instructions机架安装说明— 提供有关如何对系统使用机架的信息。此说明文件将随附在系统中。
主题
规划存储配置
连接存储阵列
存储阵列布线
一致配置与非一致配置
RAID 控制器配置
PowerVault MD3060e 扩展柜布线
— 存储阵列随附的 Getting Started Guide(使用入门指南)提供配置系统初始设置的信息。
系列存储阵列管理员指南

规划存储配置

存储阵列使
— 此管理员指
2
安装存储阵列之前请考虑以下各项
评估数据存储需要和管理要求。
计算可用性要求。
确定备份的频率和级别例如每周进行完整备份以及每天进行部分备份。
考虑存储阵列选项例如密码保护和对错误情况发送电子邮件警报通知。
根据数据组织规划设计虚拟磁盘、磁盘组和 DDP 的配置。例如一个虚拟磁盘用于存储资源清册第二个虚拟磁盘存储财务 和税务信息而第三个存储客户信息。
确定是否为热备份留出空间热备份将自动替换发生故障的物理磁盘。

连接存储阵列

存储阵列使用两个可热插拔的 RAID 控制器模块连接至主机。这些 RAID 控制器模块标识为 RAID 控制器模块 0 RAID 控制器模块 1。下面列出了 RAID 控制器模块上的端口及其功能
12 Gbps SAS 主机端口(4 可让您将主机服务器连接至存储阵列。
注: 将主机服务器连接至存储阵列 SAS IN 端口连接器时可使用服务器主机总线适配器 (HBA) 的任一输出端口连接器。
1 Gbps 以太网管理 (MGMT) 端口(1 — 管理端口用于存储阵列的带外管理。
保留的以太网端口(1 — 保留的端口。
SAS 扩展端口(2 — 可让您将存储阵列连接至可选的 PowerVault MD3060e 扩展柜以获得更多存储容量。一次只能使用一个 SAS 输出扩展端口建议的扩展端口为 0。
通过使用最多两个 MD3060e 系列扩展柜每个 PowerVault MD3460 存储阵列可最多扩展到 120 个物理磁盘如果使用高级功能激 活启用它们则可扩展到 180

存储阵列布线

可通过以下配置将存储阵列布线到主机服务器
单路径数据配置 — 单路径配置最多可连接八台主机。这是一种非一致配置。
双路径数据配置 — 双路径配置最多可连接四台主机。
可根据以下内容选择数据配置
所需主机数
硬件安装
7
所需的数据一致性级别

一致配置与非一致配置

非一致配置是指在主机与存储阵列之间仅提供一条数据路径的配置。此类配置仅建议用于非关键性的数据存储。电缆发生故障或卸 下、HBA 发生故障或 RAID 控制器模块发生故障或被卸下时会出现路径故障从而导致主机无法访问存储阵列中的存储设备。
通过在主机与存储阵列之间安装独立的数据路径即可建立一致性每条路径通往存储阵列中安装的两个 RAID 控制器模块中的一个。 一致性有助于防止主机在发生路径故障的情况下丢失对数据的访问因为这两个 RAID 控制器模块均可访问存储阵列中的所有磁盘。

RAID 控制器配置

下图显示了两台主机和四台主机的情况每台主机连接两个 RAID 控制器模块。由于每台主机有多条一致的路径因此即使丢失某一 条路径仍可通过备用路径访问存储阵列。
1: 两台主机连接到两个 RAID 控制器
8
硬件安装