Dell PowerEdge R720, PowerEdge R720xd Owner's Manual

Dell PowerEdge R720 and R720xd Owner's Manual
Regulatory Model: E14S Series Regulatory Type: E14S001
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. mentioned herein may be trademarks of their respective companies.
2014 - 07
Rev. A07
and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names
Dell
Contents
1 About Your System......................................................................................................................8
Front-Panel Features And Indicators....................................................................................................................... 8
LCD Panel Features.................................................................................................................................................11
Home Screen....................................................................................................................................................12
Setup Menu......................................................................................................................................................12
View Menu....................................................................................................................................................... 12
Diagnostic Indicators..............................................................................................................................................13
Hard-Drive Indicator Patterns................................................................................................................................ 15
Back-Panel Features And Indicators..................................................................................................................... 16
NIC Indicator Codes................................................................................................................................................17
Power Indicator Codes...........................................................................................................................................18
Other Information You May Need...........................................................................................................................19
2 Using The System Setup and Boot Manager....................................................................... 20
Choosing The System Boot Mode.......................................................................................................................... 20
Entering System Setup............................................................................................................................................21
Responding To Error Messages.......................................................................................................................21
Using The System Setup Navigation Keys.......................................................................................................21
System Setup Options.............................................................................................................................................21
System Setup Main Screen..............................................................................................................................22
System BIOS Screen........................................................................................................................................22
System Information Screen..............................................................................................................................22
Memory settings screen.................................................................................................................................. 23
Processor Settings Screen.............................................................................................................................. 23
SATA Settings Screen......................................................................................................................................25
Boot Settings Screen....................................................................................................................................... 26
Integrated devices screen............................................................................................................................... 26
Serial Communications Screen........................................................................................................................27
System Profile Settings Screen........................................................................................................................28
System Security Screen...................................................................................................................................29
Miscellaneous Settings....................................................................................................................................30
System And Setup Password Features.................................................................................................................. 30
Assigning A System And/Or Setup Password..................................................................................................30
Deleting Or Changing An Existing System And/Or Setup Password................................................................31
Using Your System Password To Secure Your System....................................................................................32
Operating With A Setup Password Enabled.................................................................................................... 32
Entering The UEFI Boot Manager...........................................................................................................................32
Using The Boot Manager Navigation Keys......................................................................................................33
Boot Manager Screen......................................................................................................................................33
UEFI Boot Menu............................................................................................................................................... 33
Embedded System Management............................................................................................................................34
iDRAC Settings Utility..............................................................................................................................................34
Entering The iDRAC Settings Utility..................................................................................................................34
Changing The Thermal Settings.......................................................................................................................34
3 Installing System Components................................................................................................35
Recommended Tools.............................................................................................................................................. 35
Front Bezel (Optional)............................................................................................................................................. 35
Removing The Front Bezel................................................................................................................................35
Installing The Front Bezel.................................................................................................................................36
Opening And Closing The System...........................................................................................................................36
Opening The System........................................................................................................................................ 36
Closing The System..........................................................................................................................................37
Inside The System...................................................................................................................................................37
Cooling Shroud....................................................................................................................................................... 39
Removing The Cooling Shroud.........................................................................................................................39
Installing The Cooling Shroud.......................................................................................................................... 40
System memory...................................................................................................................................................... 40
General Memory Module Installation Guidelines............................................................................................ 42
Mode-Specific Guidelines................................................................................................................................43
Sample memory configurations....................................................................................................................... 44
Removing Memory Modules............................................................................................................................ 46
Installing Memory Modules............................................................................................................................. 48
Hard Drives.............................................................................................................................................................49
Removing A 2.5 Inch Hard-Drive Blank............................................................................................................50
Installing A 2.5 Inch Hard-Drive Blank............................................................................................................. 50
Removing A 2.5 Inch Hard-Drive Blank (Back).................................................................................................50
Installing A 2.5 Inch Hard-Drive Blank (Back)..................................................................................................51
Removing A 3.5 Inch Hard-Drive Blank............................................................................................................51
Installing A 3.5 Inch Hard-Drive Blank............................................................................................................. 52
Removing A Hot-Swap Hard Drive...................................................................................................................52
Installing A Hot-Swap Hard Drive.................................................................................................................... 52
Removing A Hard Drive From A Hard-Drive Carrier.........................................................................................53
Installing A Hard Drive Into A Hard-Drive Carrier............................................................................................54
Optical Drive (Optional)...........................................................................................................................................54
Removing The Optical Drive.............................................................................................................................54
Installing The Optical Drive..............................................................................................................................55
Cooling Fans............................................................................................................................................................56
Removing A Cooling Fan...................................................................................................................................56
Installing A Cooling Fan....................................................................................................................................57
Removing The Cooling-Fan Assembly..............................................................................................................57
Installing The Cooling-Fan Assembly...............................................................................................................58
Internal USB Memory Key (Optional)..................................................................................................................... 58
Replacing The Internal USB Key......................................................................................................................59
PCIe Card Holder.................................................................................................................................................... 59
Removing The PCIe Card Holder......................................................................................................................59
Installing The PCIe Card Holder.......................................................................................................................60
Opening And Closing The PCIe Card Holder Latch.......................................................................................... 61
Top Cover Lock Latch............................................................................................................................................. 61
Installing The Top Cover Lock Latch................................................................................................................61
Cable Retention Bracket.........................................................................................................................................62
Removing The Cable Retention Bracket.......................................................................................................... 62
Installing The Cable Retention Bracket............................................................................................................63
Expansion Cards And Expansion-Card Risers........................................................................................................ 63
Expansion Card Installation Guidelines............................................................................................................63
Removing An Expansion Card From The Expansion-Card Riser 2 Or 3............................................................ 65
Installing An Expansion Card Into The Expansion-Card Riser 2 Or 3............................................................... 66
Removing An Expansion Card From The Expansion-Card Riser 1....................................................................67
Installing An Expansion Card Into The Expansion-Card Riser 1.......................................................................68
Removing Expansion-Card Risers.................................................................................................................... 69
Installing Expansion-Card Risers..................................................................................................................... 73
GPU Card Installation Guidelines.....................................................................................................................73
Installing A GPU Card.......................................................................................................................................73
Removing A GPU Card......................................................................................................................................75
SD vFlash Card........................................................................................................................................................76
Replacing An SD vFlash Card...........................................................................................................................77
Removing The vFlash Media Unit.....................................................................................................................77
Installing The vFlash Media Unit......................................................................................................................78
Internal Dual SD Module........................................................................................................................................ 79
Removing The Internal Dual SD Module..........................................................................................................79
Installing The Internal Dual SD Module...........................................................................................................80
Internal SD Card..................................................................................................................................................... 81
Removing An Internal SD Card.........................................................................................................................81
Installing An Internal SD Card..........................................................................................................................81
Integrated Storage Controller Card........................................................................................................................ 81
Removing The Integrated Storage Controller Card..........................................................................................82
Installing The Integrated Storage Controller Card...........................................................................................83
Network Daughter Card..........................................................................................................................................83
Removing The Network Daughter Card........................................................................................................... 83
Installing The Network Daughter Card.............................................................................................................84
Processors..............................................................................................................................................................84
Removing A Processor.....................................................................................................................................85
Installing A Processor......................................................................................................................................88
Power Supplies.......................................................................................................................................................90
Hot Spare Feature............................................................................................................................................ 90
Removing An AC Power Supply....................................................................................................................... 90
Installing An AC Power Supply........................................................................................................................ 91
Wiring Instructions For A DC Power Supply.................................................................................................... 92
Removing A DC Power Supply......................................................................................................................... 94
Installing A DC Power Supply.......................................................................................................................... 95
Removing The Power Supply Blank................................................................................................................. 96
Installing The Power Supply Blank.................................................................................................................. 96
System Battery....................................................................................................................................................... 96
Replacing The System Battery.........................................................................................................................96
Hard-Drive Backplane............................................................................................................................................ 97
Removing The Hard-Drive Backplane..............................................................................................................98
Installing The Hard-Drive Backplane.............................................................................................................111
Removing The Optional Hard-Drive Backplane (Back)..................................................................................112
Installing The Optional Hard-Drive Backplane (Back)...................................................................................114
Control Panel Board..............................................................................................................................................115
Removing The Control Panel (PowerEdge R720)............................................................................................115
Installing The Control Panel (PowerEdge R720).............................................................................................117
Removing The Control Panel (PowerEdge R720xd)........................................................................................117
Installing The Control Panel (PowerEdge R720xd).........................................................................................118
Removing The I/O Panel (PowerEdge R720xd)...............................................................................................119
Installing The I/O Panel (PowerEdge R720xd)................................................................................................120
System Board........................................................................................................................................................120
Removing The System Board.........................................................................................................................120
Installing The System Board.......................................................................................................................... 122
4 Troubleshooting Your System...............................................................................................124
Safety First—For You And Your System............................................................................................................... 124
Troubleshooting System Startup Failure.............................................................................................................. 124
Troubleshooting External Connections.................................................................................................................124
Troubleshooting The Video Subsystem................................................................................................................124
Troubleshooting A USB Device............................................................................................................................ 124
Troubleshooting A Serial I/O Device.................................................................................................................... 125
Troubleshooting A NIC..........................................................................................................................................125
Troubleshooting A Wet System............................................................................................................................125
Troubleshooting A Damaged System................................................................................................................... 126
Troubleshooting The System Battery................................................................................................................... 127
Troubleshooting Power Supplies..........................................................................................................................127
Troubleshooting Cooling Problems.......................................................................................................................127
Troubleshooting Cooling Fans.............................................................................................................................. 128
Troubleshooting System Memory.........................................................................................................................128
Troubleshooting An Internal USB Key..................................................................................................................129
Troubleshooting An SD Card................................................................................................................................ 129
Troubleshooting An Optical Drive.........................................................................................................................130
Troubleshooting A Tape Backup Unit...................................................................................................................130
Troubleshooting A Hard Drive.............................................................................................................................. 130
Troubleshooting A Storage Controller..................................................................................................................131
Troubleshooting Expansion Cards........................................................................................................................132
Troubleshooting Processors.................................................................................................................................132
5 Using System Diagnostics.....................................................................................................134
Dell Online Diagnostics.........................................................................................................................................134
Dell Embedded System Diagnostics.....................................................................................................................134
When To Use The Embedded System Diagnostics........................................................................................134
Running The Embedded System Diagnostics.................................................................................................135
System Diagnostic Controls........................................................................................................................... 135
6 Jumpers And Connectors......................................................................................................136
System Board Jumper Settings............................................................................................................................136
System Board Connectors....................................................................................................................................137
Disabling A Forgotten Password.......................................................................................................................... 139
7 Technical Specifications....................................................................................................... 140
8 System Messages...................................................................................................................146
LCD Messages......................................................................................................................................................146
Viewing LCD Messages................................................................................................................................. 146
Removing LCD Messages...............................................................................................................................146
System Error Messages........................................................................................................................................146
Warning Messages...............................................................................................................................................162
Diagnostic Messages...........................................................................................................................................162
Alert Messages.....................................................................................................................................................162
9 Getting Help..............................................................................................................................163
Contacting Dell..................................................................................................................................................... 163

About Your System

Front-Panel Features And Indicators

Figure 1. Front-Panel Features and Indicators (3.5 Inch Chassis)—PowerEdge R720
1
Figure 2. Front-Panel Features and Indicators (2.5 Inch Chassis)—PowerEdge R720
Item Indicator, Button, or
Connector
1 Power-on indicator, power
button
2 NMI button
3 System identification button The identification buttons on the front and back panels
8
Icon Description
The power-on indicator lights when the system power is on. The power button controls the power supply output to the system.
NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.
Used to troubleshoot software and device driver errors when running certain operating systems. This button can be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.
can be used to locate a particular system within a rack. When one of these buttons is pressed, the LCD panel on
Item Indicator, Button, or
Connector
4 Video connector Allows you to connect a VGA display to the system.
5 LCD menu buttons Allows you to navigate the control panel LCD menu.
6 Information tag A slide-out label panel which allows you to record system
7 LCD panel Displays system ID, status information, and system error
Icon Description
the front and the system status indicator on the back flashes until one of the buttons is pressed again.
Press to toggle the system ID on and off. If the system stops responding during POST, press and
hold the system ID button for more than five seconds to enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seconds.
information such as Service Tag, NIC, MAC address and so on as per your need.
messages. The LCD lights blue during normal system operation. The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text.
NOTE: If the system is connected to a power source and an error is detected, the LCD lights amber regardless of whether the system is turned on or off.
8 Optical drive (optional) One optional SATA DVD-ROM drive or DVD+/-RW drive.
9 Hard drives
10 vFlash media card slot Allows you to insert a vFlash media card.
11 USB connectors (2) Allows you to connect USB devices to the system. The
3.5 inch hard drive systems
2.5 inch hard drive systems
ports are USB 2.0-compliant.
Up to eight 3.5 inch hot­swappable drives.
Up to sixteen 2.5 inch hot­swappable hard drives.
NOTE: In systems supporting Dell PowerEdge Express Flash devices (PCIe SSDs), hard-drive slots 0 through 3 in hard-drive bay 2 support only PCIe SSDs. Hard-drive bay 3 does not support any hard drives and is installed with a hard-drive blank.
9
Item Indicator, Button, or
Icon Description
Connector
12 Tape drive slot (optional) One optional 3.5 inch tape backup unit.
Figure 3. Front-Panel Features and Indicators (3.5 Inch Chassis)—PowerEdge R720xd
Figure 4. Front-Panel Features and Indicators (2.5 Inch Chassis)—PowerEdge R720xd
Item Indicator, Button, or
Icon Description
Connector
1 Diagnostic indicators The diagnostic indicators light up to display error status.
2 System identification button The identification buttons on the front and back panels
can be used to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the back flashes until one of the buttons is pressed again.
Press to toggle the system ID on and off. If the system stops responding during POST, press and
hold the system ID button for more than five seconds to enter BIOS progress mode.
To reset the iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seconds.
3 Power-on indicator, power
button
The power-on indicator lights when the system power is on. The power button controls the power supply output to the system.
NOTE: On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.
10
Item Indicator, Button, or
Connector
4 NMI button Used to troubleshoot software and device driver errors
5 Hard drives
Icon Description
when running certain operating systems. This button can be pressed using the end of a paper clip.
Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.
3.5 inch hard drive systems
Up to twelve 3.5 inch hot­swappable hard drives.
2.5 inch hard drive systems
6 Video connector Allows you to connect a VGA display to the system.
7 USB connector Allows you to connect USB devices to the system. The
port is USB 2.0-compliant.
8 Information tag A slide-out label panel which allows you to record system
information such as Service Tag, NIC, MAC address, and so on as per your need.
Up to twenty-four 2.5 inch hot­swappable hard drives.

LCD Panel Features

NOTE: The LCD panel is present only on PowerEdge R720.
The system's LCD panel provides system information and status and error messages to indicate when the system is operating correctly or when the system needs attention. See System Error Messages for information about specific error codes.
The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition.
The LCD backlight is off when the system is in standby mode and can be turned on by pressing either the Select, Left, or Right button on the LCD panel.
The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools.
Figure 5. LCD Panel Features
11
Item Button Description 1 Left Moves the cursor back in one-step
increments.
2 Select Selects the menu item highlighted by
the cursor.
3 Right Moves the cursor forward in one-step
increments. During message scrolling:
Press once to increase scrolling speed
Press again to stop
Press again to return to default scrolling speed
Press again to repeat the cycle

Home Screen

The Home screen displays user-configurable information about the system. This screen is displayed during normal system operation when there are no status messages or errors. When the system is in standby mode, the LCD backlight turns off after five minutes of inactivity if there are no error messages. Press one of the three navigation buttons (Select, Left, or Right) to view the Home screen.
To navigate to the Home screen from another menu, continue to select the up arrow until the Home icon is displayed, and then select the Home icon.
From the Home screen, press the Select button to enter the main menu.

Setup Menu

NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next action.
Option Description
iDRAC Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available
fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view domain addresses. Two separate DNS entries are available.
Set error Select SEL to display LCD error messages in a format that matches the IPMI description in the
SEL. This is useful when trying to match an LCD message with an SEL entry. Select Simple to display LCD error messages in a simplified user-friendly description. See
System Error Messages for a list of messages in this format.
Set home Select the default information to be displayed on the LCD Home screen. See View Menu to see
the options and option items that can be set as the default on the Home screen.

View Menu

NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.
12
Option Description
iDRAC IP Displays the IPv4 or IPv6 addresses for the iDRAC7. Addresses include DNS (Primary and
Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).
MAC Displays the MAC addresses for iDRAC, iSCSI, or Network devices.
Name Displays the name of the Host, Model, or User String for the system
Number Displays the Asset tag or the Service tag for the system.
Power Displays the power output of the system in BTU/hr or Watts. The display format can be
configured in the Set home submenu of the Setup menu.
Temperature Displays the temperature of the system in Celsius or Fahrenheit. The display format can be
configured in the Set home submenu of the Setup menu.

Diagnostic Indicators

NOTE: The diagnostic indicators are present only on PowerEdge R720xd.
The diagnostic indicators on the system front panel display error status during system startup.
NOTE: No diagnostic indicators are lit when the system is switched off. To start the system, plug it into a working power source and press the power button.
The following section describes system conditions and possible corrective actions associated with these indicators:
Health indicator
Condition Corrective Action
If the system is on, and in good health, the indicator lights solid blue.
The indicator blinks amber if the system is on or in standby, and any error exists (for example, a failed fan or hard drive)
Hard-drive indicator
Condition Corrective Action
The indicator blinks amber if a hard drive experiences an error.
None required.
See the System Event Log or system messages for the specific issue.
Invalid memory configurations can cause the system to halt at startup without any video output. See Getting Help.
See the System Event Log to determine the hard drive that has an error. Run the appropriate Online Diagnostics test. Restart system and run embedded diagnostics (ePSA). If the hard drives are configured in a RAID array, restart the system and enter the host adapter configuration utility program.
13
Electrical indicator
Condition Corrective Action
The indicator blinks amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply or voltage regulator).
Temperature indicator
Condition Corrective Action
The indicator blinks amber if the system experiences a thermal error (for example, a temperature out of range or fan failure).
Memory indicator
See the System Event Log or system messages for the specific issue. If it is due to a problem with the power supply, check the LED on the power supply. Re-seat the power supply by removing and reinstalling it. If the problem persists, see Getting Help.
Ensure that none of the following conditions exist:
A cooling fan is removed or has failed.
System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
See Getting Help.
Condition Corrective Action
The indicator blinks amber if a memory error occurs.
PCIe indicator
Condition Corrective Action
The indicator blinks amber if a PCIe card experiences an error.
14
See the system event log or system messages for the location of the failed memory. Reinstall the memory device. If the problem persists, see Getting Help.
Restart the system. Update any required drivers for the PCIe card. Re-install the card. If the problem persists, see Getting Help.

Hard-Drive Indicator Patterns

Figure 6. Hard-Drive Indicators
1. hard-drive activity indicator (green) 2. hard-drive status indicator (green and amber)
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off.
Drive-Status Indicator Pattern (RAID Only)
Blinks green two times per second
Off Drive ready for insertion or removal
Blinks green, amber, and off
Blinks amber four times per second
Blinks green slowly Drive rebuilding
Steady green Drive online
Blinks green three seconds, amber three seconds, and off six seconds
Condition
Identifying drive or preparing for removal
NOTE: The drive status indicator remains off until all hard drives are initialized after the system is turned on. Drives are not ready for insertion or removal during this time.
Predicted drive failure
Drive failed
Rebuild aborted
15

Back-Panel Features And Indicators

Figure 7. Back-Panel Features and Indicators—PowerEdge R720
Figure 8. Back-Panel Features and Indicators—PowerEdge R720xd
Item Indicator, Button, or
Connector
1 System identification button The identification buttons on the front and back panels
2 System identification
connector
Icon Description
can be used to locate a particular system within a rack.
PowerEdge R720 When one of these buttons is
PowerEdge R720xd
Press to toggle the system ID on and off. If the system stops responding during POST, press and
hold the system ID button for more than five seconds to enter BIOS progress mode.
To reset iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seconds.
Connects the optional system status indicator assembly through the optional cable management arm.
pressed, the LCD panel on the front and the system status indicator on the back flashes until one of the buttons is pressed again.
When one of these buttons is pressed, the system status indicator on the back flashes until one of the buttons is pressed again.
3 iDRAC7 Enterprise port Dedicated management port.
NOTE: The port is available for use only if the iDRAC7 Enterprise license is installed on your system.
16
Item Indicator, Button, or
Connector
Icon Description
4 PCIe expansion card slots
low–profile (3)
5 Serial connector Allows you to connect a serial device to the system.
6 Video connector Allows you to connect a VGA display to the system.
7 USB connectors (2) Allows you to connect USB devices to the system. The
8 Ethernet connectors Four integrated 10/100/1000 Mbps NIC connectors
9 PCIe expansion card slots
full height (4) (PowerEdge R720)
PCIe expansion card slots full height (3) (PowerEdge R720xd)
10 Power supply (PSU1)
11 Power supply (PSU2)
Allows you to connect up to three PCI Express expansion cards.
ports are USB 2.0-compliant.
or Four integrated connectors that include:
Two 10/100/1000 Mbps NIC connectors
Two 100 Mbps/1 Gbps/10 Gbps SFP+/10 GbE T connectors
Allows you to connect up to four full-height PCI Express expansion cards.
Allows you to connect up to three full-height PCI Express expansion cards.
AC 495 W, 750 W, or 1100 W
or
DC 750 W, or 1100 W
12 Hard drives (2) (back) Up to two hot-swappable 2.5 inch hard drives.
13 vFlash media card slot Allows you to insert a vFlash media card.

NIC Indicator Codes

Figure 9. NIC Indicator
link indicator 2. activity indicator
1.
17
Indicator Indicator Code
Link and activity indicators are off
Link indicator is green
Link indicator is amber
Activity indicator is blinking green
The NIC is not connected to the network.
The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps).
The NIC is connected to a valid network at less than its maximum port speed.
Network data is being sent or received.

Power Indicator Codes

Each AC power supply has an illuminated translucent handle and each DC power supply (when available) has an LED that serves as an indicator to show whether power is present or whether a power fault has occurred.
Figure 10. AC Power Supply Status Indicator
1. AC power supply status indicator/handle
Figure 11. DC Power Supply Status Indicator
1.
DC power supply status indicator
18
Power Indicator Pattern
Not lit Power is not connected.
Green The handle/LED indicator lights green indicating that a valid power source is connected to the
Flashing amber Indicates a problem with the power supply.
Flashing green When hot-adding a power supply, this indicates that the power supply is mismatched with the
Condition
power supply and that the power supply is operational.
CAUTION: When correcting a power supply mismatch, replace only the power supply with the flashing indicator. Swapping the opposite power supply to make a matched pair can result in an error condition and unexpected system shutdown. To change from a High Output configuration to a Low Output configuration or vice versa, you must power down the system.
CAUTION: AC power supplies support both 220 V and 110 V input voltages with the exception of Titanium power supplies, which support only 220 V. When two identical power supplies receive different input voltages, they can output different wattages, and trigger a mismatch.
CAUTION: If two power supplies are used, they must be of the same type and have the same maximum output power.
CAUTION: Combining AC and DC power supplies is not supported and triggers a mismatch.
other power supply (in terms of efficiency, feature set, health status, and supported voltage). Replace the power supply that has the flashing indicator with a power supply that matches the capacity of the other installed power supply.

Other Information You May Need

WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document.
The
Getting Started Guide
document is available online at dell.com/support/manuals.
The rack documentation included with your rack solution describes how to install your system into a rack, if required.
Any media that ships with your system that provides documentation and tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.
For the full name of an abbreviation or acronym used in this document, see the Glossary at dell.com/support/ manuals.
NOTE: Always check for updates on dell.com/support/manuals and read the updates first because they often supersede information in other documents.
provides an overview of setting up your system, and technical specifications. This
19

Using The System Setup and Boot Manager

System Setup enables you to manage your system hardware and specify BIOS-level options. The following keystrokes provide access to system features during startup:
2
Keystroke
<F2>
<F10>
<F11>
<F12>
From the System Setup, you can:
Change the NVRAM settings after you add or remove hardware
View the system hardware configuration
Enable or disable integrated devices
Set performance and power management thresholds
Manage system security
You can access the System Setup using the:
Description Opens the System Setup page.
Enters System Services and starts Lifecycle Controller, which supports systems management features such as operating system deployment, hardware diagnostics, firmware updates, and platform configuration, using a graphical user interface. The feature set available in Lifecycle Controller is determined by the iDRAC license purchased. For more information, see Related Documentation topic.
Enters the BIOS Boot Manager or the Unified Extensible Firmware Interface (UEFI) Boot Manager, depending on the system's boot configuration.
Starts Preboot Execution Environment (PXE) boot.
Standard graphical browser, which is enabled by default
Text browser, which is enabled using Console Redirection
To enable Console Redirection, in System Setup, select System BIOSSerial Communication screenSerial Communication, select On with Console Redirection.
NOTE: By default, help text for the selected field is displayed in the graphical browser. To view the help text in the text browser, press <F1>.

Choosing The System Boot Mode

System Setup enables you to specify the boot mode for installing your operating system:
BIOS boot mode (the default) is the standard BIOS-level boot interface.
UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI) specifications that overlays the system BIOS.
20
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the boot mode, the system boots in the specified boot mode and you then proceed to install your operating system from that mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating system. Trying to boot the operating system from the other boot mode will cause the system to halt at startup.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot mode.
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport.

Entering System Setup

1. Turn on or restart your system.
2. Press <F2> immediately after you see the following message:
<F2> = System Setup
If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart your system and try again.

Responding To Error Messages

If an error message is displayed while the system is booting, make a note of the message. For more information, see System Error Messages.
NOTE: After installing a memory upgrade, it is normal for your system to display a message the first time you start your system.

Using The System Setup Navigation Keys

Keys Action
Up arrow Moves to the previous field.
Down arrow Moves to the next field.
<Enter> Allows you to type in a value in the selected field (if applicable) or follow the link in the field.
Spacebar Expands or collapses a drop-down menu, if applicable.
<Tab> Moves to the next focus area.
NOTE: For the standard graphics browser only.
<Esc> Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen
displays a message that prompts you to save any unsaved changes and restarts the system.
<F1> Displays the System Setup help file.
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system.

System Setup Options

21

System Setup Main Screen

NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.
Menu Item Description
System BIOS This option is used to view and configure BIOS settings.
iDRAC Settings This option is used to view and configure iDRAC settings.
Device Settings This option is used to view and configure device settings.

System BIOS Screen

NOTE: The options for System Setup change based on the system configuration.
NOTE: System Setup defaults are listed under their respective options in the following sections, where applicable.
Menu Item Description
System Information Displays information about the system such as the system model name, BIOS version, Service
Tag, and so on.
Memory Settings Displays information and options related to installed memory.
Processor Settings Displays information and options related to the processor such as speed, cache size, and so
on.
SATA Settings Displays options to enable or disable the integrated SATA controller and ports.
NOTE: This setting is not available on the PowerEdge R720xd.
Boot Settings Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS
boot settings.
Integrated Devices Displays options to enable or disable integrated device controllers and ports, and to specify
related features and options.
Serial Communication Displays options to enable or disable the serial ports and specify related features and options.
System Profile Settings
System Security Displays options to configure the system security settings like, system password, setup
Miscellaneous Settings
Displays options to change the processor power management settings, memory frequency, and so on.
password, TPM security, and so on. It also enables or disables support for local BIOS update, the power and NMI buttons on the system.
Displays options to change the system date, time, and so on.

System Information Screen

Menu Item
System Model Name Displays the system model name.
Description
22
Menu Item Description
System BIOS Version Displays the BIOS version installed on the system.
System Service Tag Displays the system Service Tag.
System Manufacturer Displays the name of the system manufacturer.
System Manufacturer Contact Information
Displays the contact information of the system manufacturer.

Memory settings screen

Menu Item Description
System Memory Size Displays the amount of memory installed in the system.
System Memory Type Displays the type of memory installed in the system.
System Memory Speed
System Memory Voltage
Video Memory Displays the amount of video memory.
System Memory Testing
Memory Operating Mode
Displays the system memory speed.
Displays the system memory voltage.
Specifies whether system memory tests are run during system boot. Options are Enabled and Disabled. By default, the System Memory Testing option is set to Disabled.
Specifies the memory operating mode. The options available are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory Operating Mode option is set to Optimizer Mode.
NOTE: The Memory Operating Mode can have different defaults and available options based on the memory configuration of your system.
NOTE: The Dell Fault Resilient Mode establishes an area of memory that is fault resilient. This mode can be used by an operating system that supports the feature to load critical applications or enables the operating system kernel to maximize system availability.
Node Interleaving If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is
installed. If Disabled, the system supports Non-Uniform Memory architecture (NUMA) (asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.
Serial Debug Output By default, it is set to disabled.

Processor Settings Screen

Menu Item Description
Logical Processor Allows you to enable or disable logical processors and display the number of logical
processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical processors. If this option is set to Disabled, the BIOS only displays one logical processor per core. By default, the Logical Processor option is set to Enabled.
23
Menu Item Description
QPI Speed Allows you to set the QuickPath Interconnect data rate settings. By default, the QPI Speed
option is set to Maximum data rate.
NOTE: The QPI speed option displays only when both the processors are installed.
Alternate RTID (Requestor Transaction ID) Setting
Virtualization Technology
Adjacent Cache Line Prefetch
Hardware Prefetcher Allows you to enable or disable hardware prefetcher. By default, the Hardware Prefetcher
DCU Streamer Prefetcher
DCU IP Prefetcher Allows you to enable or disable Data Cache Unit IP prefetcher. By default, the DCU IP
Execute Disable Allows you enable or disable execute disable memory protection technology. By default, the
Logical Processor Idling
Dell Controlled Turbo Helps in controlling Turbo engagement. By default, the option is set to Disabled. This feature is
Allows you to allocate more RTIDs to the remote socket increasing cache performance between the sockets or work in normal mode for NUMA. By default, the Alternate RTID (Requestor Transaction ID) Setting is set to Disabled.
Allows you to enable or disable the additional hardware capabilities provided for virtualization. By default, the Virtualization Technology option is set to Enabled.
Allows you to optimize the system for applications that require high utilization of sequential memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can disable this option for applications that require high utilization of random memory access.
option is set to Enabled.
Allows you to enable or disable Data Cache Unit streamer prefetcher. By default, the DCU Streamer Prefetcher option is set to Enabled.
Prefetcher option is set to Enabled.
Execute Disable option is set to Enabled.
Allows you to enable or disable the OS capability to put logical processors in the idling state in order to reduce power consumption. By default, the option is set to Disabled.
also referred to as Dell Processor Acceleration Technology (DPAT).
Number of Cores per Processor
24
NOTE: This option is available only on systems installed with an E5-2690 or E5-2600 V2 Xeon series processor and support Turbo. Enable Turbo Boost under System Profile Settings and set the System Profile to Performance mode when utilizing this feature. Enabling Dell Controlled Turbo will force fans to run at maximum R.P.M.
NOTE: DPAT works when DPAT is enabled in BIOS setup and either one of the following settings is available:
System Profile is set to Maximum Performance. This automatically enables Turbo mode.
System Profile is set to Custom and CPU Power Management is set to Maximum Performance and Turbo is enabled.
NOTE: When DPAT is disabled, fan offset speed does not change and remains high. Set Fan offset to normal on the iDRAC Thermal Settings page.
Allows you to control the number of enabled cores in each processor. By default, the Number of Cores per Processor option is set to All.
Menu Item Description
Processor 64-bit Support
Processor Core Speed
Processor Bus Speed Displays the bus speed of the processors.
Processor 1
Family-Model­Stepping
Brand Displays the brand name reported by the processor.
Level 2 Cache Displays the total L2 cache.
Level 3 Cache Displays the total L3 cache.
Number of Cores Displays the number of cores per processor.
Specifies if the processor(s) support 64-bit extensions.
Displays the maximum core frequency of the processor.
NOTE: The processor bus speed option displays only when both the processors are installed.
NOTE: The following settings are displayed for each processor installed in the system.
Displays the family, model and stepping of the processor as defined by Intel.

SATA Settings Screen

Menu Item Description
Embedded SATA Allows the embedded SATA to be set to Off, ATA, AHCI, or RAID mode. By default, Embedded
SATA is set to AHCI Mode.
Port A Auto enables BIOS support for the device attached to SATA port A. By default, Port A is set to
Auto.
Port B Auto enables BIOS support for the device attached to SATA port B. By default, Port B is set to
Auto.
Port C Auto enables BIOS support for the device attached to SATA port C. By default, Port C is set to
Auto.
Port D Auto enables BIOS support for the device attached to SATA port D. By default, Port D is set to
Auto.
Port E Auto enables BIOS support for the device attached to SATA port E. By default, Port E is set to
Auto.
Port F Auto enables BIOS support for the device attached to SATA port F. By default, Port F is set to
Auto.
NOTE
: Ports A, B, C, and D are used for the backplane drives, port E for the optical drive (CD/DVD), and port F for
the tape drive.
25

Boot Settings Screen

Menu Item Description
Boot Mode Allows you to set the boot mode of the system.
CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in the same boot mode.
If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set to BIOS.
NOTE: Setting this field to UEFI disables BIOS Boot Settings menu. Setting this field to BIOS disables the UEFI Boot Settings menu.
Boot Sequence Retry Allows you to enable or disable the boot sequence retry feature. If this field is enabled and the
system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the Boot Sequence Retry option is set to Disabled.
BIOS Boot Settings Allows you to enable or disable BIOS Boot options.
NOTE: This option is enabled only if the boot mode is BIOS.
UEFI Boot Settings Allows you to enable or disable UEFI Boot options. The Boot options include IPv4 PXE and IPv6
PXE. By default, the UEFI PXE boot protocol is set to IPv4.
NOTE: This option is enabled only if the boot mode is UEFI.
One-Time Boot Allows you to enable or disable a one-time boot from a selected device.

Integrated devices screen

Menu Item Description
Integrated RAID Controller
User Accessible USB Ports
Internal USB Port Allows you to enable or disable the internal USB port. By default, the Internal USB Port option
Internal SD Card Port Enables or disables the system’s internal SD card port. By default, Internal SD Card Port option
Internal SD Card Redundancy
Allows you to enable or disable the integrated RAID controller. By default, the Integrated RAID Controller option is set to Enabled.
Allows you enable or disable the user accessible USB ports. Selecting Only Back Ports On disables the front USB ports and selecting All Ports Off disables both front and back USB ports. By default, the User Accessible USB Ports option is set to All Ports On.
is set to On.
is set to On.
NOTE: This option is displayed only if IDSDM is installed on the system board.
If set to Mirror mode, data is written on both SD cards. If any one of the SD card fails, data is written to the active SD card. Data from this card is copied to the replacement SD card at the next boot. By default, Internal SD Card Redundancy option is set to Mirror.
26
Menu Item Description
NOTE: This option is displayed only if IDSDM is installed on the system board.
Integrated Network Card 1
OS Watchdog Timer Allows you to enable or disable the OS watchdog timer. When this field is enabled, the
Embedded Video Controller
SR-IOV Global Enable Allows you to enable or disable the BIOS configuration of Single Root I/O Virtualization (SR-
Slot Disablement Allows you to enable or disable available PCIe slots on your system. The Slot Disablement
Memory Mapped I/O above 4 GB
Allows you to enable or disable the integrated network card 1. By default, the Integrated Network Card 1 option is set to Enabled.
operating system initializes the timer and the OS watchdog timer helps in recovering the operating system. By default, the OS Watchdog Timer option is set to Disabled.
Allows you to enable or disable the Embedded Video Controller. By default, the embedded video controller is Enabled.
IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.
feature controls the configuration of PCIe cards installed in the specified slot.
CAUTION: Slot disablement must be used only when the installed peripheral card is preventing booting into the Operating System or causing delays in system startup. If the slot is disabled, both the Option ROM and UEFI driver are disabled.
Allows you to enable support for PCIe devices that require large amounts of memory. By default, the option is set to Enabled.

Serial Communications Screen

Menu Item Description
Serial Communication Allows you to select serial communication devices (Serial Device 1 and Serial Device 2) in the
BIOS. BIOS console redirection can also be enabled and the port address can be specified. By default, Serial Communication option is set to On without Console Redirection.
Serial Port Address Allows you to set the port address for serial devices. By default, the Serial Port Address option
is set to Serial Device 1=COM2, Serial Device 2=COM1.
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console redirection by SOL, configure the same port address for console redirection and the serial device.
External Serial Connector
Failsafe Baud Rate Displays the failsafe baud rate for console redirection. The BIOS attempts to determine the
Remote Terminal Type
Allows you to associate the external serial connector to serial device 1, serial device 2, or remote access device. By default, the External Serial Connector option is set to Serial Device1.
NOTE: Only Serial Device 2 can be used for SOL. To use console redirection by SOL, configure the same port address for console redirection and the serial device.
baud rate automatically. This failsafe baud rate is used only if the attempt fails and the value must not be changed. By default, the Failsafe Baud Rate option is set to 11520.
Allows you to set the remote console terminal type. By default, the Remote Terminal Type option is set to VT 100/VT 220.
27
Menu Item Description
Redirection After Boot
Allows you to enable or disable to the BIOS console redirection when the operating system is loaded. By default, the Redirection After Boot option is set to Enabled.

System Profile Settings Screen

Menu Item Description
System Profile Allows you to set the system profile. If you set the System Profile option to a mode other than
Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. By default, the System Profile option is set to Performance Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.
NOTE: The following parameters are available only when the System Profile is set to Custom.
CPU Power Management
Memory Frequency Allows you to set the memory frequency. By default, the Memory Frequency option is set to
Turbo Boost Allows you to enable or disable the processor to operate in turbo boost mode. By default, the
C1E Allows you to enable or disable the processor to switch to a minimum performance state when
Allows you to set the CPU power management. By default, the CPU Power Management option is set to System DBPM (DAPC). DBPM is Demand-Based Power Management.
Maximum Performance.
Turbo Boost option is set to Enabled.
it is idle. By default, the C1E option is set to Enabled.
C States Allows you to enable or disable the processor to operate in all available power states. By
default, the C States option is set to Enabled.
Monitor/Mwait Allows you to enable Monitor/Mwait instructions in the processor. By default, the Monitor/
Mwait option is set to Enabled for all system profiles, except Custom.
NOTE: This option can be disabled only if the C States option in Custom mode is disabled.
NOTE: When C States is enabled in Custom mode, changing the Monitor/Mwait setting does not impact system power/performance.
Memory Patrol Scrub Allows you to set the memory patrol scrub frequency. By default, the Memory Patrol Scrub
option is set to Standard.
Memory Refresh Rate Allows you to set the memory refresh rate. By default, the Memory Refresh Rate option is set to
1x.
Memory Operating Voltage
Collaborative CPU Performance Control
Allows you to set the DIMM voltage selection. When set to Auto, the system automatically sets the system voltage to the optimal setting based on the DIMM capacity and the number of DIMMs installed. By default, the Memory Operating Voltage option is set to Auto.
When set to Enabled, the CPU power management is controlled by the OS DBPM and the System DBPM (DAPC). By default, the option is set to Disabled.
28

System Security Screen

Menu Item Description
Intel AES-NI Improves the speed of applications by performing encryption and decryption using the
Advanced Encryption Standard Instruction Set and is set to Enabled by default.
System Password Allows you to set the system password. This option is set to Enabled by default and is read-only
if the password jumper is not installed in the system.
Setup Password Allows you to set the setup password. This option is read-only if the password jumper is not
installed in the system.
Password Status Allows you to lock the system password. By default, the Password Status option is set to
Unlocked.
TPM Security Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the
TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On without Pre-boot Measurements.
TPM Activation Allows you to change the operational state of the TPM. By default, the TPM Activation option is
set to No Change.
TPM Status Displays the TPM status.
TPM Clear
Intel TXT Allows you to enable or disable Intel Trusted Execution Technology (TXT). To enable Intel TXT,
BIOS Update Control Allows you to update the BIOS using either DOS or UEFI shell-based flash utilities. For
Power Button Allows you to enable or disable the power button on the front of the system. By default, the
NMI Button Allows you to enable or disable the NMI button on the front of the system. By default, the NMI
AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default,
AC Power Recovery Delay
User Defined Delay (60s to 240s)
CAUTION: Clearing the TPM results in the loss of all keys in the TPM. The loss of TPM keys may affect booting to the operating system.
Allows you to clear all the contents of the TPM. By default, the TPM Clear option is set to No.
Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot measurements. By default, the Intel TXT option is set to Off.
environments that do not require local BIOS updates, it is recommended to set this option to Disabled. By default, the BIOS Update Control option is set to Unlocked.
NOTE: BIOS updates using the Dell Update Package are not affected by this option.
Power Button option is set to Enabled.
Button option is set to Disabled.
the AC Power Recovery option is set to Last.
Allows you to set how the system supports staggering of power up after AC power is restored to the system. By default, the AC Power Recovery Delay option is set to Immediate.
Allows you to set the User Defined Delay when the User Defined option for AC Power Recovery Delay is selected.
29

Miscellaneous Settings

Menu Item Description
System Time Allows you to set the time on the system.
System Date Allows you to set the date on the system.
Asset Tag Displays the asset tag and allows you to modify it for security and tracking purposes.
Keyboard NumLock Allows you to set whether the system boots with the NumLock enabled or disabled. By default
the Keyboard NumLock is set to On.
NOTE: This option does not apply to 84-key keyboards.
Report Keyboard Errors
F1/F2 Prompt on Error Allows you to enable or disable the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is
In-System Characterization
Allows you to set whether keyboard-related error messages are reported during system boot. By default, the Report Keyboard Errors option is set to Report.
set to Enabled.
This option enables or disables In-System Characterization. By default, In-System Characterization is set to Enabled.

System And Setup Password Features

You can create a system password and a setup password to secure your system. To enable creation of the system and setup password, the password jumper must be set to enabled. For more information on the password jumper settings, see System Board Jumper Settings.
System password This is the password that you must enter before you can boot your system.
Setup password This is the password that you must enter to access and make changes to the BIOS or UEFI
settings of your system.
CAUTION: The password features provide a basic level of security for the data on your system.
CAUTION: Anyone can access the data stored on your system if the system is running and unattended.
NOTE: Your system is shipped with the system and setup password feature disabled.

Assigning A System And/Or Setup Password

NOTE: The password jumper enables or disables the System Password and Setup Password features. For more information on the password jumper settings, see System Board Jumper Settings.
You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup Password only when the password jumper setting is enabled and Password Status is Unlocked. If the Password Status is Locked, you cannot change the System Password and/or Setup Password.
If the password jumper setting is disabled, the existing System Password and Setup Password is deleted and you need not provide the system password to boot the system.
30
Loading...