Scripting WS-MAN Firmware Updates
This Dell Technical White Paper provides information about scripting WS-MAN Firmware Inventory and F irmware Updates on Dell PowerEdge servers with iDRAC.
Author(s)
Chris A. Poblete Raja Tamilarasan
Page 2
This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind.
© 2012 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, and PowerEdge are trademarks of Dell Inc. Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.
February 2012| Rev 1.0
ii Scripting WS-MAN Firmware Updates
Page 3
Executive summary
This paper describes how to automate firmware inventory an d updates through a secure and standards-based Web Services-Management (WS-MAN) service on Dell™ PowerEdge™ servers with Integrated Dell Remote Access Controller with Lifecycle Controller (iDRAC).
iii Scripting WS-MAN Firmware Updates
Page 4
Contents
Introduction ....................................................................................... 5
Before You Begin ................................................................................. 5
Performing a firmware update ................................................................ 6
Install firmware information on the system ............................................... 7
Begin the update process .................................................................... 8
Monitor the update execution ............................................................. 12
Performing a firmware rollback.............................................................. 13
Exceptions ...................................................................................... 15
Summary ........................................................................................ 15
Additional Resources .......................................................................... 15
iv Scripting WS-MAN Firmware Updates
Page 5

Introduction

WS-MAN provides secure, simple, scriptable, and standards-based remote management capabilities on Dell PowerEdge servers equipped with iDRAC.
WS-MAN is a network transport service that enables a user to access a number of Common Information Model (CIM) data access and methods supported by the target platform. WS-MAN can be scripted using command line interfaces (CLI) such as WinRM on Microsoft® Windows® systems and WS-MAN CLI on Linux systems.
This document uses the Python scripting platform, which run son both Windows and Linux systems. Some additional reading of specification documents may be required to understand the terminology and concepts in this paper.
In this document, you will learn how to:
View firmware information/inventory on a system.
Perform a firmware update.
Perform a firmware rollback.

Before You Begin

Before you begin, it is recommended to take the following actions:
1. Make sure the target system is a PowerEdge server with iDRAC enabled, configured, and network accessible to communicate with WS-MAN.
2. For Windows, make sure the WinRM command line tool is configured and ready (for help, see
Installation and Configuration of Windows Remote Management
For Linux, make sure the Openwsman CLI is built, installed, a nd read y (fo r help, go to the
Openwsman Home
3. Make sure Python 2.7 is installed on the target system (for help, see Python Home).
4. Download the following Python scripts:
a. [fw_inventory.py] b. [fwupdate.py] c. [fw_poll.py]
and join the mailing list).
).
5 Scripting WS-MAN Firmware Updates
Page 6
WSMAN over SSL
Target System
Administrator
Update Repository
1
2
3
FTP / HTTP / TFTP / NFS / CIFS
Download
Figure 1 - Environment Diagr am
Figure 2 shows an example of the target environment. It starts with the administrator (1) running scripts to send WS-MAN commands through an SSL connection. The target system (2) is equipped with iDRAC, which is a management controller with advanced capabilities. The update repository (3) contains the Dell Update Packages (DUPs) that will be used to update the firmware on the target system.

Performing a firmware update

The remote firmware update process involves the following steps
1. View the current firmware inventory of the system
2. Begin the update process
3. Monitor the update process
6 Scripting WS-MAN Firmware Updates
Page 7

Install firmware information on the system

1. Run fw_inventory.py –h to see Usage options.
./fw_inventory.py --help
Usage: fw_inventory.py [options]
Options:
-h, --help show this help message and exit
-v, --verbose Prints information verbosely
-f FWUPDATE, --firmware component=FWUPDATE prints component information(nic, bios, idrac_fw, drivers_pack, power_supply, raid, lifecycle_controller, diagnostics)
2. Enter requested information:
Enter iDRAC IP Address: [iDRAC IP] Enter User Name: [USER NAME] Enter User Password: [PASSWORD]
The first argument is the IP address of the iDRAC on the target system. The second argument is the user name; if the user is an Active Directory account, then the syntax is USER@DOMAIN. The third argument is the user password.
3. The script establishes a connection with the iDRAC and also performs certificate validation.
3 Pinging 192.168.0.206. Waiting for response. Done.
Getting SSL Certificate. Waiting for response. Done
4. Once a successful connection is established, the fw_inventory.py script performs a Software Inventory and lists components that are installed and available to be rolled back.
Sample output:
OPTION Component Status Comp ID Version Type
1(update) FRMW Installed 26018 0.12 BP12G+ 0:2
2(update) FRMW Installed 68138 D505 Physical Disk 0:2:0
3(update) FRMW Installed Empty 7.0.21 Broadcom NetXtreme Gigabit Ethernet
4(update) FRMW Installed Empty 7.0.21 Broadcom NetXtreme Gigabit Ethernet
5(update) BIOS Installed 159 0.3.32 BIOS
6(update) FRMW Installed Empty 7.0.21 Broadcom NetXtreme Gigabit Ethernet
7(update) FRMW Installed 26041 03.10.13 Power Supply.Slot.1
7 Scripting WS-MAN Firmware Updates
Page 8
8(update) FRMW Installed 25227 1.00.00 Integrated Dell Remote Access
Controller
9(rollback) FRMW Available 25227 1.00.00 Integrated Dell Remote Access
Controller
10(update) APAC Installed 25806 4216.1 Dell Enterprise UEFI Diagnostics
Diagnostics Utility
11(update) APAC Installed 28897
1.0.0.3551, X69
12(update) FRMW Installed 27763 0.5.3 System CPLD
13(update) APAC Installed 18981 7.0.0.38 Dell OS Driver Pack,
14(update) FRMW Installed Empty 3.0.0-0135 PERC S110 Controller
15(update) FRMW Installed Empty 20.10.1-0066 PERC H310 Mini
1.0.0.3551 Dell Lifecycle Controller 2,

Begin the update process

1. Run fwupdate.py –h for usage options.
./fwupdate.py -h Usage: fwupdate.py [options]
Options:
-h, --help show this help message and exit
-f CONFIG_FILE, --file=CONFIG_FILE Enter config file with parameters the script needs. Example of a file is fwupdate.cfg.
-v, --verbose Prints information verbosely
--cleanenv Cleans .log, .xml, and .cer files in current directory.
2. Enter requested information:
v.7.0.0.38, X38
Enter iDRAC IP Address: [iDRAC IP]
Enter User Name: [USER NAME] Enter User Password: [PASSWORD]
The first argument is the IP address of the iDRAC on the target system. The second argument is the user name; if the user is an Active Directory account, then the syntax is USER@DOMAIN. The third argument is the user password.
3. The script establishes a connection with the iDRAC and also performs certificate validation.
Pinging 192.168.0.206. Waiting for response. Done.
Getting SSL Certificate. Waiting for response. Done
4. Once a successful connection is established, the fwupdate.py script performs a Software Inventory and lists the components that are available to be updated.
8 Scripting WS-MAN Firmware Updates
Page 9
Sample output:
[Firmware Component Inventory List] b - bios dp - drivers_pack i - idrac_fw n - nic p - power_supply r - raid lc - lifecycle_controller d - diagnostics a - all
Each entry in the output lists a device that can either be updated to firmware located on a network share (ftp/http/tftp/nfs/cifs) or rolled back to a previous firmware version stored on the iDRAC.
5. Select the component alias (from step 3) for the component you would like to inventory. Once a component type is selected, the script lists options that are available for rollback and update for that particular component.
View component firmware inventory: n
OPTION Component Status Comp ID Version Type
1(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
2(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
3(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
4(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
5(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
6(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
7(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:49
8(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:49
9(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:49
9 Scripting WS-MAN Firmware Updates
Page 10
Once the firmware inventory is listed, you can either continue with the firmware update or quit. To perform a firmware update, select one of the options that are available for update.
The script will prompt for the location of the Dell Update Package (DUP) to be used. iDRAC supports the following download methods with source URI syntax:
FTP ftp://[IPADDRESS]/[LOCATION]/[DUPFILENAME]
HTTP http://[IPADDRESS]/[LOCATION]/[DUPFILENAME]
TFTP tftp://[IPADDRESS]/[LOCATION]/[DUPFILENAME]
CIFS cifs://[USER]:[PASSWORD]@[IPADDRESS]/[LOCATION]/[DUPFILENAME];mountpoint=[MOUNTN
AME]
NFS nfs://[IPADDRESS]/[LOCATION]/[DUPFILENAME];mountpoint=[MOUNTNAME]
The all-caps portions of the syntax represent user-provided values. The [IPADDRESS] is the IP address of the update package repository. The [LOCATION] is the path or dire cto ry. The [DUPFILENAME] is the update package file name; the only supported update package is the “Dell Update Package for Windows” that can be downloaded from support.dell.com. [USER] and [PASSWORD] refer to the user credentials required to access and download files from the share. [MOUNTNAME] refers to the share mount name.
Sample output:
Options
tftp://192.168.0.100/BIOS-2011.exe
nfs://192.168.0.100/BIOS-2011.exe;mountpoint=/pub
cifs://DOMAIN\\USER:PASS@192.168.0.100/pub/BIOS-2011.exe;mountpoint=E
http://192.168.0.100/BIOS-2011.exe
ftp://192.168.0.100/BIOS-2011.exe
Enter the path of the image file: tftp://192.168.0.3/DUP.exe
6.
The script will prompt for a reboot type that the host will use reboot before performing the update. Select an appropriate reboot type.
Reboot Type Options (1,2,3, and 4)
10 Scripting WS-MAN Firmware Updates
Page 11
1 = Forceful shutdown and reboot
2 = Graceful shutdown and reboot (Recommended)
3 = Forceful shutdown if graceful shutdown does not succeed
4 = No reboot
7. The script asks for permission to delete all existing jobs in iDRAC. It is recommended to choose yes for a clean start.
Erase all previous jobs stored in the iDRAC? (yes/no) yes
Deleting all iDRAC jobs
Completed job deletion
8. The script requests a start time for the job. The job can be scheduled immediately or for a future time.
Schedule the nic update now or schedule later (now, schedule)? now
The format of the StartTime argument is defined by the CIM Infrastructure Specification. Enter now to schedule the jobs immediately, or enter schedule to schedule the job for a future time. The schedule option will prompt for a start time, which you must enter in the format MM-DD-YYYY hh:mm:ss
Y = Year, M = Month, D = Day, H = Hour, m = minute, S = second
12-13-2011 11:11:11
Once the start time is specified, the update job is initiated.
The update package is downloaded from the repository. This may take some time depending on the size of the package and network state. After the update package is successfully downloaded, the update and the reboot job are scheduled for the specified start time.
Sample output of successful command:
nic update successfully created
Creating reboot job
Reboot job successfully created.
Scheduling nic update job
Scheduling reboot job
The nic updating from version 7.0.21 to version ftp://10.35.155.122/Release_DUPS/Network_Firmware_JXJWY_WN_7.0.46_X36.EXE
11 Scripting WS-MAN Firmware Updates
Page 12
Check the status of the reboot job and the nic update job by using the fw_pull.py
script.
Sample output of failed command:
The command failed with error code: CMPI_RC_ERR_INVALID_PARAMETER
If the command fails, check that the InstanceID you provided is accurate by comparing it with output from the previous step. Remember that characters are case sensitive. Also, check the accuracy of the source URI to ensure it is accessible with proper permission. Once verified, try the command again.
After the specified start time elapses, the host reboots and launces System Services to perform the firmware update.

Monitor the update execution

The final step in the update process is to monitor when the update executes, and then to verify the update by checking the new version from the inventory enumeration.
1. Run fw_poll.py –h for usage options
./fw_poll.py -h
Usage: fw_poll.py [options]
Options:
-h, --help show this help message and exit
-j JOBID, --JobID=JOBID Provide one of the JobIDs (begins with JID or RID) within the fwupdate.out file
-v, --verbose Prints information verbosely
2. Enter requested information:
Enter iDRAC IP Address: [iDRAC IP]
Enter User Name: [USER NAME] Enter User Password: [PASSWORD]
1. The first argument is the IP address of the iDRAC on the target system. The second argument is the user name; if the user is an Active Directory account, then the syntax is USER@DOMAIN. The third argument is the user password.
Sample output:
Available JobIDs.
(1) JID_267336093962
- nic updating to image located at
ftp://10.35.155.122/Release_DUPS/Network_Firmware_JXJWY_WN_7.0.46_X36.EXE
(2) RID_267336106745
12 Scripting WS-MAN Firmware Updates
Page 13
- reboot for nic update
(0) exit out
Enter a number to poll JobID or to exit. (1,2,etc): 1
JobStatus = Scheduled
Message = Task successfully scheduled.
MessageArguments = NA
MessageID = JCP001
Name = update:DCIM:INSTALLED#701__NIC.Integrated.1-2-1
Repeat get JobStatus command for JID_267336093962? (yes, no):
3. Select the number corresponding to your job to display the current status. The script performs two step executions. The first step is to monitor the status of the job associated
with the update. When it detects the status is completed, it monitors the status of the data sync. At this time, the update has been executed and the device is running the new firmware level.

Performing a firmware rollback

A firmware rollback applies a device’s previously installed firmware version. This is useful when you encounter a new firmware level that was just updated and is causing problems or incompatibilities in the system.
To determine if firmware can be rolled back, examine the inventory list and look for “available” in the status. For example:
5(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet
BCM5720 - 18:03:73:0F:45:48
To perform a rollback, select the firmware entry marked “available” and run the update script without the source URI. The script will detect that the request is a roll back and will execute the proper commands. Unlike an update, a rollback does not go through the download phase. Jump to scheduling the update and follow the rest of the process.
Sample output:
./fwupdate.py
Enter iDRAC IP Address: 10.36.0.117 Enter User Name: root Enter User Password: Pinging 10.36.0.117. Waiting for response. Done. Certificate exists!
13 Scripting WS-MAN Firmware Updates
Page 14
[Firmware Component Inventory List] b - bios dp - drivers_pack i - idrac_fw n - nic p - power_supply r - raid lc - lifecycle_controller d - diagnostics a - all
View component firmware inventory: n OPTION Component Status Comp ID Version Type 1(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 2(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 3(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 4(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 5(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 6(rollback) FRMW Available None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:49 7(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:49 8(rollback) FRMW Available None 7.0.46 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:48 9(update) FRMW Installed None 7.0.47 Broadcom Gigabit Ethernet BCM5720
- 18:03:73:0F:45:49
Choices: d Select different component OPTION 1,2,3 ENTER: 1 Reboot Type Options (1,2,3, and 4) 1 = Forceful shutdown and reboot 2 = Graceful shutdown and reboot (Recommended) 3 = Forceful shutdown if graceful shutdown does not succeed 4 = No reboot Enter reboot type: 1 Erase all previous jobs stored in the iDRAC? (yes/no) yes Deleting all iDRAC jobs Completed job deletion Schedule the nic rollback now or schedule later (now, schedule)? now Creating nic rollback job nic rollback successfully created Creating reboot job Reboot job successfully created. Scheduling nic rollback job Scheduling reboot job The nic rollback from 7.0.47 to the image 7.0.47 Check the status of the reboot job and the nic rollback job by using the fw_pull.py script.
14 Scripting WS-MAN Firmware Updates
Page 15

Exceptions

One exception to the process described in the previous sections is that certain updat es do not require a reboot and scheduling. After the update package is downloaded, it is immediately applied to the device. This exception applies to Lifecycle Controller, Diagnostics, and OS Driver Pack firmware updates. System CPLD Updates are currently not supported by this method.

Summary

In this paper, you have learned how to perform an inventory of firmware installed on your system, a firmware update on select system devices, and a firmware rollback.

Additional Res ources

Lear more about firmware inventory as defined by the Dell CIM profile specification:
http://www.delltechcenter.com/page/DCIM.Library.Profiles.DCIM+Software+Inventory+Profile+1.0
Lear more about firmware update as defined by the Dell CIM profile specification:
http://www.delltechcenter.com/page/DCIM.Library.Profile.DCIM+Software+Update+Profile+1.0
Lear more about job control as defined by the Dell CIM profile specification:
http://www.delltechcenter.com/page/DCIM+Job+Control+Profile+1.1
WS-MAN Interface Guide for Linux:
http://attachments.wetpaintserv.us/BMJk79WsVP3F0jwl50xR_w2088275
WS-MAN Interface Guide for Windows:
http://attachments.wetpaintserv.us/utYVFQFaHmnfG_LHEnx1YQ2026735
WS-MAN command line open source for Linux (OpenWS-MAN):
http://sourceforge.net/projects/openWS-MAN/
WS-MAN command line for Window s (WinRM):
http://msdn.microsoft.com/en-us/library/windows/desktop/aa384291(v=VS.85).aspx
All about Lifecycle Controller in iDRAC:
http://support.dell.com/support/edocs/software/smusc/smlc/lc_1_5/index.htm
15 Scripting WS-MAN Firmware Updates
Loading...