Dell PowerEdge R6525 User Manual [zh]

Dell EMC PowerEdge R6525
Installation and Service Manual
Regulatory Model: E67S Regulatory Type: E67S001 July 2020 Rev. A03
注意、小心和警告
注: “注意”表示更好地使用该产品的重要信息。
警告: “警告”表示可能财产损失、人身害甚至死亡。
© 2019 - 2020 Dell Inc. 或其子公司。保留所有利。DellEMC 和其他商 Dell Inc. 或其附的商。其他商可能是其各自所有者的商
Contents
Chapter 1: 于本明文件................................................................................................................7
Chapter 2: ........................................................................................................................ 8
的前视图........................................................................................................................................................................ 8
控制面板视图.........................................................................................................................................................10
控制面板视图..........................................................................................................................................................11
的背面视图...................................................................................................................................................................12
............................................................................................................................................................................... 15
找到快速服和服务编..........................................................................................................................................15
信息标签.......................................................................................................................................................................16
导轨调整和机架兼容性矩..............................................................................................................................................18
Chapter 3: 初始系统设置和配置....................................................................................................... 20
置系.............................................................................................................................................................................. 20
iDRAC 配置.......................................................................................................................................................................... 20
用于 iDRAC IP 地址的选项..................................................................................................................................20
用于登 iDRAC 选项............................................................................................................................................... 21
用于安装操作系.................................................................................................................................................. 21
固件的选项............................................................................................................................................................ 22
安装操作系统驱动程序的选项.......................................................................................................................22
载驱动程序和固件....................................................................................................................................................23
Chapter 4: 装操作系管理用程序..............................................................................................24
统设...............................................................................................................................................................................24
BIOS....................................................................................................................................................................... 24
iDRAC 用程序....................................................................................................................................................36
设备设.........................................................................................................................................................................37
戴尔生命周期控制器..........................................................................................................................................................37
嵌入式系管理............................................................................................................................................................ 37
管理器...........................................................................................................................................................................37
PXE .............................................................................................................................................................................. 37
Chapter 5: 安装和卸下系统组....................................................................................................... 38
安全...............................................................................................................................................................................38
拆装算机件之前................................................................................................................................................. 39
拆装系件之后..................................................................................................................................................... 39
工具.............................................................................................................................................................................. 39
的前...................................................................................................................................................................... 40
卸下前.................................................................................................................................................................... 40
安装前.................................................................................................................................................................... 40
统护............................................................................................................................................................................... 41
卸下系统护................................................................................................................................................................. 41
安装系统护................................................................................................................................................................ 42
驱动器背板.................................................................................................................................................................. 43
Contents 3
卸下驱动器背板....................................................................................................................................................43
安装驱动器背板....................................................................................................................................................44
控制面板.............................................................................................................................................................................. 45
卸下右控制面板........................................................................................................................................................45
安装右控制面板........................................................................................................................................................46
卸下左控制面板........................................................................................................................................................46
安装左控制面板........................................................................................................................................................ 47
VGA ..............................................................................................................................................................................48
卸下 VGA .............................................................................................................................................................. 48
安装 VGA .............................................................................................................................................................. 49
................................................................................................................................................................................... 51
卸下..................................................................................................................................................................... 51
安装.................................................................................................................................................................... 52
冷却.............................................................................................................................................................................. 54
卸下冷却扇模........................................................................................................................................................54
安装冷却扇模........................................................................................................................................................54
驱动.................................................................................................................................................................................. 55
卸下驱动............................................................................................................................................................55
安装驱动............................................................................................................................................................ 56
卸下驱动器托架............................................................................................................................................................ 56
安装驱动器托架............................................................................................................................................................ 57
驱动器托中卸下驱动....................................................................................................................................... 58
驱动器安装到驱动器托架中................................................................................................................................... 59
驱动器背板.......................................................................................................................................................................... 60
驱动器背板.................................................................................................................................................................... 60
卸下驱动器背板.............................................................................................................................................................61
安装驱动器背板............................................................................................................................................................ 62
Cable routing........................................................................................................................................................................64
背面驱动器模.................................................................................................................................................................. 70
卸下背面驱动器模....................................................................................................................................................70
安装背面驱动器模.....................................................................................................................................................71
前置 PERC .................................................................................................................................................................. 72
卸下正面安装的前置 PERC ............................................................................................................................... 72
安装正面安装的前置 PERC ............................................................................................................................... 73
卸下背面安装的前置 PERC ............................................................................................................................... 74
安装背面安装的前置 PERC ...............................................................................................................................75
...............................................................................................................................................................................76
存指南................................................................................................................................................................ 76
一般存模安装原................................................................................................................................................78
卸下存模................................................................................................................................................................ 80
安装存模................................................................................................................................................................. 81
理器和散.................................................................................................................................................................. 82
卸下散.....................................................................................................................................................................82
卸下理器.....................................................................................................................................................................83
安装理器.................................................................................................................................................................... 85
安装散.....................................................................................................................................................................87
展卡和展卡提升板..................................................................................................................................................... 89
展卡安装原............................................................................................................................................................ 89
卸下展卡提升板........................................................................................................................................................ 97
安装展卡提升板...................................................................................................................................................... 100
4
Contents
展卡提升板中卸下展卡..................................................................................................................................102
展卡安装到展卡提升板中............................................................................................................................. 104
的串行 COM 端口.....................................................................................................................................................106
卸下串行 COM 端口................................................................................................................................................... 106
安装串行 COM 端口................................................................................................................................................... 107
IDSDM .......................................................................................................................................................... 108
卸下 IDSDM .........................................................................................................................................................108
安装 IDSDM .........................................................................................................................................................108
MicroSD ......................................................................................................................................................................... 109
卸下 MicroSD ..........................................................................................................................................................109
安装 MicroSD ...........................................................................................................................................................110
M.2 SSD ...................................................................................................................................................................... 111
卸下 M.2 SSD ....................................................................................................................................................... 111
安装 M.2 SSD ...................................................................................................................................................... 112
统电..............................................................................................................................................................................113
统电................................................................................................................................................................113
USB ........................................................................................................................................................... 115
卸下 USB ..........................................................................................................................................................115
安装 USB ..........................................................................................................................................................115
盗开关..................................................................................................................................................................... 116
卸下防盗开关....................................................................................................................................................... 116
安装防盗开关........................................................................................................................................................117
OCP ................................................................................................................................................................... 118
卸下 OCP ..................................................................................................................................................................118
安装 OCP ..................................................................................................................................................................119
源装置.............................................................................................................................................................................120
热备盘功能...................................................................................................................................................................120
卸下源装置....................................................................................................................................................... 121
安装源装置....................................................................................................................................................... 121
卸下源装置................................................................................................................................................................121
安装源装置...............................................................................................................................................................122
可信平台模.....................................................................................................................................................................123
可信平台模.......................................................................................................................................................123
初始化 TPM..................................................................................................................................................... 124
初始化 TPM 1.2............................................................................................................................................... 124
初始化 TPM 2.0...............................................................................................................................................124
................................................................................................................................................................................. 125
卸下系...................................................................................................................................................................125
安装系................................................................................................................................................................... 126
使用 Easy Restore 原服务编............................................................................................................................. 128
LOM 卡和背面 I/O .......................................................................................................................................................128
卸下 LOM 卡和背面 I/O ........................................................................................................................................128
安装 LOM 卡和背面 I/O ........................................................................................................................................129
Chapter 6: 线接器................................................................................................................131
接器......................................................................................................................................................................131
板跳线设.................................................................................................................................................................133
禁用已忘的密............................................................................................................................................................ 133
Contents
5
Chapter 7: 术规......................................................................................................................134
机箱尺寸.............................................................................................................................................................................135
重量............................................................................................................................................................................. 136
理器格.........................................................................................................................................................................136
PSU ............................................................................................................................................................................ 136
支持的操作系.................................................................................................................................................................136
冷却.....................................................................................................................................................................137
统电.....................................................................................................................................................................138
展卡提升板............................................................................................................................................................ 138
............................................................................................................................................................................. 138
控制器.................................................................................................................................................................139
驱动.........................................................................................................................................................................139
驱动........................................................................................................................................................................... 139
端口和接器............................................................................................................................................................ 140
USB 端口.............................................................................................................................................................. 140
NIC 端口............................................................................................................................................................... 140
串行接器...........................................................................................................................................................140
VGA 端口..............................................................................................................................................................140
IDSDM........................................................................................................................................................................... 140
视频规..............................................................................................................................................................................141
..............................................................................................................................................................................141
限制...............................................................................................................................................................143
限制列表...............................................................................................................................................................143
Chapter 8: 统诊程序和指示灯代............................................................................................ 146
LED 指示灯............................................................................................................................................................... 146
状况和系 ID 指示灯代..............................................................................................................................147
iDRAC Quick Sync 2 指示灯代.....................................................................................................................................147
iDRAC Direct LED 指示灯代........................................................................................................................................ 148
液晶面板.........................................................................................................................................................................148
看主...............................................................................................................................................................149
置菜....................................................................................................................................................................... 149
视图....................................................................................................................................................................... 149
NIC 指示灯代码.................................................................................................................................................................150
源装置指示灯代........................................................................................................................................................ 150
驱动器指示灯代............................................................................................................................................................ 152
使用系统诊程序............................................................................................................................................................ 152
戴尔嵌入式系统诊程序..........................................................................................................................................153
Chapter 9: ..................................................................................................................... 154
回收或停售服信息........................................................................................................................................................ 154
系戴尔.............................................................................................................................................................................154
使用 QRL 访问信息..........................................................................................................................................154
PowerEdge R6525 的快速源定位符............................................................................................................155
过 SupportAssist 接收自支持..................................................................................................................................155
Chapter 10: 明文件..............................................................................................................156
6
Contents

于本明文件

明文件提供于系、有安装和装回件的信息、技术规格、工具,以及安装特定要遵循的原
1
于本明文件 7
PowerEdge R6525 1U 机架式服器,支持:
两个 AMD EYPCTM 7002 系列理器
32 DIMM
两个冗余交流或直流源装置
4 x 3.5 英寸、8 x 2.5 英寸或 10 x 2.5 英寸 SASSATA NVMe 驱动器。
2

注:如何拔 NVMe PCIe SSD U.2 设备的更多信息,请
:https://www.dell.com/support 浏览所有品 > 据中心基构 > 适配器和控制器 > 戴尔 PowerEdge Express Flash NVMe PCIe SSD > > 明文件。
: SASSATA 驱动器、PCIe SSD NVMe 的所有例在本明文件中都为驱动器,除非另有明。
支持的驱动器的情,驱动器规格部分。
Dell Express Flash NVMe PCIe SSD User's Guide
的前视图
的背面视图
找到快速服和服务编
信息标签
导轨调整和机架兼容性矩

的前视图

1: 10 x 2.5 英寸驱动器系的前视图
. 1: 系统正面上可用功能
端口、面板和 图标
1 控制面板 不适用
8
包含系状况、系 ID LED,以及 iDRAC Quick Sync 2 (无线)指示灯。
LED:允所有出故障的硬件件。有多
Quick Sync 2(无线):指示 Quick Sync 的系Quick
注: iDRAC Quick Sync 2 指示灯在某些配置中提供。
LED 和体系状况 LED(机箱状况和系 ID。有更多信息, LED 指示灯部分。
Sync 功能是可的。此功能允使用移动设备管理系 OpenManage Mobile (OMM) 功能。使用 iDRAC Quick Sync 2 OpenManage Mobile (OMM),可以集合硬件或固件
清册以及各统级诊错误信息,以用于故障理系。有更多信息,iDRAC
www.dell.com/idracmanuals
指南
址:https://
. 1: 正面上可用功能
端口、面板和 图标
2 VGA 端口 您将设备连接到系。有关详情, VGA 端口规
面上的 140 部分。
3 右侧控制面板 不适用 包含源按USB 端口、iDRAC Direct 微型端口和 iDRAC Direct
态 LED
4 信息标签
5 驱动 (10) 不适用
2: 8 x 2.5 英寸驱动器系的前视图
. 2: 系统正面上可用功能
端口、面板和 图标
1 控制面板 不适用
信息标签是一滑出式标签面板,其中包含服务标签NICMAC 地址等系信息。如果选择 iDRAC 安全默认访问则该信息 标签还包含 iDRAC 安全默
安装系支持的驱动器。有驱动器的更多信息,
部分。
包含系状况、系 ID LED,以及 iDRAC Quick Sync 2 (无线)指示灯。
注: iDRAC Quick Sync 2 指示灯在某些配置中提供。
LED:允许您所有出故障的硬件件。有多 LED 体系状况 LED(机箱状况和系 ID
。有更多信息, LED 指示灯部分。
Quick Sync 2(无线):指示 Quick Sync 的系Quick Sync 功能是可的。此功能允使用移动设备管理系 为 OpenManage Mobile (OMM) 功能。使用 iDRAC Quick Sync 2 OpenManage Mobile (OMM),可以集合硬件或固件
清册以及各统级诊错误信息,以用于故障理系。有更多信息,iDRAC
www.dell.com/idracmanuals
2 驱动 (8) 不适用 安装系支持的驱动器。有驱动器的更多信息,
部分。
3 右侧控制面板 不适用 包含源按USB 端口、iDRAC Direct 微型端口和 iDRAC Direct
态 LED
4 VGA 端口
5 信息标签
您将设备连接到系。有关详情, VGA 端口规面上的 140 部分。
信息标签是一滑出式标签面板,其中包含服务标签NICMAC 地址等系信息。如果选择 iDRAC 安全默认访问则该信息 标签还包含 iDRAC 安全默
指南
址:https://
9
3: 4 x 3.5 英寸驱动器系的前视图
. 3: 正面上可用功能
端口、面板和 图标
1 控制面板 不适用
2 驱动 (4) 不适用 安装系支持的驱动器。有驱动器的更多信息,
3 VGA 端口 您将设备连接到系。有情, VGA 端口
4 控制面板 不适用 包含源按USB 端口、iDRAC Direct 微型端口和 iDRAC Direct
包含系状况、系 ID LED,以及 iDRAC Quick Sync 2 (无线)指示灯。
注: iDRAC Quick Sync 2 指示灯在某些配置中提供。
LED:允许您所有出故障的硬件件。有多 LED 体系状况 LED(机箱状况和系 ID
。有更多信息, LED 指示灯部分。
Quick Sync 2(无线):指示 Quick Sync 的系Quick Sync 功能是可的。此功能允使用移动设备管理系 为 OpenManage Mobile (OMM) 功能。使用 iDRAC Quick Sync 2 OpenManage Mobile (OMM),可以集合硬件或固件
清册以及各统级诊错误信息,以用于故障理系。有更多信息,iDRAC
www.dell.com/idracmanuals
部分。
面上的 140 部分。
LED。
指南
址:https://
5 信息标签
端口的情,“技术规格”部分。

控制面板视图

4: iDRAC Quick Sync 2 指示灯的左控制面板
信息标签是一滑出式标签面板,其中包含服务标签NICMAC 地址等系信息。如果选择 iDRAC 安全默认访问则该信息 标签还包含 iDRAC 安全默
10
5: iDRAC Quick Sync 2 指示灯的左控制面板
. 4: 控制面板
指示灯、按接器 图标
1 LED 指示灯 不适用
2
3
注:指示灯代的更多信息,“系统诊程序和指示灯代部分。
状况和系 ID 指 示灯
iDRAC Quick Sync 2 线 示灯(可
表示系状况。有更多信息, LED 指示灯”部 分。
指示系状况。有更多信息,“系状况和系
ID 指示灯代部分。
指示 iDRAC Quick Sync 2 线选项是否已用。Quick Sync 2 功能 允使用移动设备管理系。此功能集合了硬件或固件清册和各统级诊错误信息,可用于故障排除系可 以访问Dell Lifecycle Controller 日志或系日志、系 状况状态以及如何配置 iDRACBIOS 参数也可以 在支持的移动设备拟键盘视频和鼠 (KVM) 看器以 及基于核的 (KVM)。有更多信息,
“Integrated Dell Remote Access Controller User's Guide” Integrated Dell Remote Access Controller 指南),址:
www.dell.com/poweredgemanuals

控制面板视图

6: 控制面板视图
. 5: 右侧控制面板
指示灯或按 图标
1 电源按
指示系是打。按源按即可手
11
. 5: 控制面板 (
指示灯或按 图标
USB 2.0 兼容端口
2
iDRAC Direct LED 指示灯 不适用 iDRAC Direct LED 指示灯亮起表示 iDRAC Direct 端口主
3
iDRAC Direct 端口 (Micro-AB USB) iDRAC Direct (Micro-AB USB) 端口用于访问 iDRAC Direct
4
注:端口的更多信息,端口和接器部分。
USB 端口是 4 针连接器且兼容 2.0。此端口允您将 USB 设备连接到系
接至设备
(Micro-AB) 功能。有情,iDRAC 址:https://www.dell.com/idracmanuals

的背面视图

注:源按以正常 ACPI 兼容的操作系
指南
注: 您可以使用 USB micro USB (type AB) 线缆配
iDRAC Direct,以电脑或平板电脑线 缆长度不得超 0.91 米(3 英尺)。线缆量可能 性能。
7: 10 x 2.5 英寸驱动器系的背面视图
. 6: 系统的背面视图
端口、面板或 图标
1 源装置 (PSU 1) PSU 配置的更多信息,术规部分。
2
3
4 USB 2.0 端口 (1) 此端口兼容 USB 2.0
5 源装置 (PSU 2) PSU 配置的更多信息,术规部分。
6
7 USB 3.0 端口 (1) 此端口兼容 USB 3.0
8 iDRAC 用端口
9 统识 按下系 ID
PCIe 展卡提升板(1不适用
PCIe 展卡提升板(2不适用
VGA 端口 您将设备连接到系。有更多信息,术规
展卡提升板允 PCI Express 展卡。有关您的系 支持的展卡的更多信息,“技术规格”部分。
展卡提升板允 PCI Express 展卡。有关您的系 支持的展卡的更多信息,“技术规格”部分。
部分。
访问 iDRAC。有更多信息,iDRAC User’
s Guide》,址:www.dell.com/poweredgemanuals
可定位机架中的特定系
12
. 6: 的背面视图
端口、面板或 图标
开启 ID
要重 iDRAC按住保持 16 秒以上。
:
要使用系 ID iDRAC确保在 iDRAC 置中 用了系统 ID
如果系机自检过程中停止按住系 ID (五秒以上)可 BIOS 程模式。
10
11 NIC 端口(2 NIC 端口嵌入在接到系板的 LOM 卡上。
端口的情,“技术规格”部分。
8: 8 x 2.5 英寸驱动器系的背面视图
. 7: 系统的背面视图
端口、面板或 图标
1 源装置 (PSU 1) PSU 配置的更多信息,术规部分。
2
OCP NIC 端口(可 不适用 此端口支持 OCP 3.0NIC 端口集成在接到系板的 OCP
卡上。
PCIe 展卡提升板(1不适用
展卡提升板允 PCI Express 展卡。有关您的系支持的展卡的更多信息,技术规部分。
3
4 USB 2.0 端口 (1) 此端口兼容 USB 2.0
5 PCIe 展卡提升板(3不适用
6 源装置 (PSU 2) PSU 配置的更多信息,术规部分。
7
8 USB 3.0 端口 (1) 此端口兼容 USB 3.0
9 iDRAC 用端口
10 统识 按下系 ID
PCIe 展卡提升板(2不适用
VGA 端口 您将设备连接到系。有更多信息,术规
展卡提升板允 PCI Express 展卡。有关您的系 支持的展卡的更多信息,“技术规格”部分。
展卡提升板允 PCI Express 展卡。有关您的系 支持的展卡的更多信息,“技术规格”部分。
部分。
访问 iDRAC。有更多信息,iDRAC User’
s Guide》,址:www.dell.com/poweredgemanuals
可定位机架中的特定系
开启 ID
要重设 iDRAC按住保持 16 秒以上。
13
. 7: 的背面视图
端口、面板或 图标
注:
要使用系 ID iDRAC确保在 iDRAC 设置中
用了系统 ID
如果系机自检过程中停止按住系 ID (五秒以上)可 BIOS 程模式。
11
12 NIC 端口(2 NIC 端口嵌入在接到系板的 LOM 卡上。
端口的情,“技术规格”部分。
9: 2 x 2.5 英寸背面驱动器模 4 x 3.5 英寸驱动器系的背面视图
. 8: 系统的背面视图
端口、面板或 图标
1 源装置 (PSU 1) PSU 配置的更多信息,术规部分。
2
OCP NIC 端口(可 不适用 此端口支持 OCP 3.0NIC 端口集成在接到系板的 OCP
卡上。
背面驱动器模 不适用
安装系支持的驱动器。有驱动器的更多信息, 驱动器部分。
3
4 PCIe 展卡提升板(3不适用
5 源装置 (PSU 2) PSU 配置的更多信息,术规部分。
6
7 USB 3.0 端口 (1) 此端口兼容 USB 3.0
8 iDRAC 用端口
9 统识 按下系 ID
USB 2.0 端口 (1) 此端口兼容 USB 2.0
展卡提升板允 PCI Express 展卡。有关您的系 支持的展卡的更多信息,“技术规格”部分。
VGA 端口 您将设备连接到系。有更多信息,术规
部分。
访问 iDRAC。有更多信息,iDRAC User’
s Guide》,址:www.dell.com/poweredgemanuals
可定位机架中的特定系
开启 ID
要重设 iDRAC按住保持 16 秒以上。
:
要使用系 ID iDRAC确保在 iDRAC 置中 用了系统 ID
如果系机自检过程中停止按住系 ID (五秒以上)可 BIOS 程模式。
14
. 8: 的背面视图
端口、面板或 图标
10
11 NIC 端口(2 NIC 端口嵌入在接到系板的 LOM 卡上。
端口的情,“技术规格”部分。
OCP NIC 端口(可 不适用 此端口支持 OCP 3.0NIC 端口集成在接到系板的 OCP
卡上。

10:
驱动器背板 2. 背面安装的前置 PERC
1.
3. 扇模 (4) 4.
5. 适用于理器 2 DIMM (B1) 6. 适用于理器 2 的散
7. 提升板 3 8. 盗开关
9. 源装置 (PSU 2) 10. 源装置 (PSU 1)
11. IDSDM/ USB 卡端口 12. 提升板 2
13. 理器 1 的散 14. 适用于理器 1 DIMM (A1)
15. xGMI 线缆

找到快速服和服务编

唯一快速服和服务编可用于
信息位于系正面 ,其中包括系信息,例如服务编、快速服、制造日期、NICMAC 地址、QRL 标签等。如果选择 iDRAC 安全默认访问则该信息标签还包含 iDRAC 安全默。如果选择 iDRAC Quick Sync 2,那信息标签会包 OpenManage Mobile (OMM) 标签,以便管理用于配置、控和 PowerEdge 器。
15
11: 找到快速服和服务编
1. 信息标签(前视图 2. 信息标签(后视图
3. OpenManage Mobile (OMM) 标签 4. iDRAC MAC 地址(MAC 地址)和 iDRAC 安全密码标签
5. 务编、快速服QRL 标签
小型企务编号 (MEST) 标签位于系背面,包括服务编号 (ST)、快速服码 (Exp Svc Code) 和制造日期 (MfgDate)Exp Svc Code Dell EMC 用于支持呼叫合适的人
或者,服务编信息位于机箱左壁上的标签上。

信息标签

信息标签位于系统护盖的背面。
16
12: 信息
17
13: 存信息和系接器
14: LED 、配置和布局、快速服务编

导轨调整和机架兼容性矩

关与您的系兼容的导轨方案的特定信息, Dell EMC Enterprise Systems Rail Sizing and Rack Compatibility Matrix(Dell EMC
统导轨大小整和机架兼容性矩
Docs_Documents/en/rail-rack-matrix.pdf
本文提供下面列出的信息:
址:https://i.dell.com/sites/csdocuments/Business_solutions_engineering-
18
导轨型及其功能的具体详细信息
机架安装凸型的导轨调节
有和不带线缆管理配件的导轨深度
机架安装凸型支持的机架
19

初始系统设置和配置

本部分介 Dell EMC 的初始置和配置任。本部分提供了置系统时完成的常,以及包含详细信息的考指 南。
置系
iDRAC 配置
用于安装操作系

置系

行以下步,以的系
1. 包装。
2. 安装到机架中。有详细信息,阅导轨线缆管理解方案相导轨安装和线缆管理配件指南,址:
www.dell.com/poweredgemanuals
3. 围设备连接至系,然后统连接至座。
4. 源按开启 置系的更多信息,附的 Getting Started Guide
3

iDRAC 配置

Integrated Dell Remote Access Controller (iDRAC) 设计用于提高系管理的工作效率和 Dell EMC 器的整体可用性。iDRAC 会就统问题警告管理助管理员执程系管理,少物理访问的需要。

用于 iDRAC IP 地址的选项

要在的系 iDRAC 用通信,首先根据配置络设置。络设选项认设DHCP
注: 对于 IP 配置,购买时请设置。
可以使用以下接口 iDRAC IP 地址。有如何 iDRAC IP 地址的信息,表中提供的文接。
. 9: 设置 iDRAC IP 地址的界面
界面
iDRAC 用程序 Integrated Dell Remote Access Controller User's Guide 址是:
https://www.dell.com/idracmanuals,而系特定的 Integrated
Dell Remote Access Controller User's Guide 址是:https://
www.dell.com/poweredgemanuals > 适用于的系品支持
> 手明文件
注: 要确定适用于的平台的最新 iDRAC 版本和最新的文
版本,识库文章 https://www.dell.com/support/
article/sln308699
Dell OpenManage 部署工具包 OpenManage
www.dell.com/openmanagemanuals > Open Manage 部署工具
包。
部署工具包用指南
址:https://
20 初始系统设置和配置
. 9: iDRAC IP 地址的界面 (
界面
生命周期控制器 Lifecycle Controller User’s Guide 址是:https://
www.dell.com/idracmanuals,而系特定的 Lifecycle Controller
User’s Guide 址是:https://www.dell.com/
poweredgemanuals > 适用于的系品支持 >
明文件
注: 要确定适用于的平台的最新 iDRAC 版本和最新的文
版本,识库文章 https://www.dell.com/support/
article/sln308699
器液晶面板 液晶面板部分。
iDRAC Direct Quick Sync 2(可 Integrated Dell Remote Access Controller User's Guide 址是:
https://www.dell.com/idracmanuals,而系特定的 Integrated
Dell Remote Access Controller User's Guide 址是:https://
www.dell.com/poweredgemanuals > 适用于的系品支持
> 手明文件
注: 要确定适用于的平台的最新 iDRAC 版本和最新的文
版本,识库文章 https://www.dell.com/support/
article/sln308699
: 要访问 iDRAC,确保使用 USB 线缆以太线缆连接到 iDRAC9 端口或使用 iDRAC Direct 端口。如果经选
用共享 LOM 模式的系也可以通共享 LOM 模式访问 iDRAC

用于登 iDRAC 选项

要登 iDRAC Web 界面,浏览入地址 IP
可以凭借下列身 iDRAC
iDRAC
Microsoft Active Directory
录访问协议 (LDAP)
示的登幕中,如果选择安全默认访问 iDRAC请输入信息标签背面提供的 iDRAC 安全默。如果选择退出安 全默认访问 iDRAC则输入默的用名和密码 – root calvin。也可以使用一登或智能卡登
注: 确保在置 iDRAC IP 地址后更改默的用名和密
录 iDRAC iDRAC 的更多信息,新的 Integrated Dell Remote Access Controller User's Guide址:
www.dell.com/idracmanuals
: 要确定适用于的平台的最新 iDRAC 版本和最新的文版本,识库文章 https://www.dell.com/support/article/
sln308699
也可以使用命令行协议 RACADM 访问 iDRAC。有详细信息, iDRAC with Lifecycle Controller RACADM CLI Guide, 址:www.dell.com/idracmanuals
也可以使用自化工具 Redfish API 访问 iDRAC。有详细信息, iDRAC9 with Lifecycle Controller Redfish API Guide, 址:https://www.dell.com/idracmanuals

用于安装操作系

如果系统发货时未安装操作系可以使用下表中提供的一种资安装支持的操作系。有如何安装操作系的信息,表中提供的文接。
统设置和配置 21
初始系
. 10: 用于安装操作系
iDRAC Integrated Dell Remote Access Controller User's Guide址是:https://www.dell.com/idracmanuals,而
特定的 Integrated Dell Remote Access Controller User's Guide址是:https://www.dell.com/
poweredgemanuals > 适用于的系产品支持 > 明文件
注: 要确定适用于的平台的最新 iDRAC 版本和最新的文版本,识库文章 https://
www.dell.com/support/article/sln308699
生命周期控制器 Lifecycle Controller User’s Guide 址是:https://www.dell.com/idracmanuals,而系特定的 Lifecycle
Controller User’s Guide 址是:https://www.dell.com/poweredgemanuals > 适用于的系品支持
> 明文件
戴尔建安装生命周期控制器以安装操作系,因所有所需的驱动程序都已安装到系中。
: 要确定适用于的平台的最新 iDRAC 版本和最新的文版本,识库文章 https://
www.dell.com/support/article/sln308699
Dell OpenManage 部署 工具包
戴尔认证 VMware
ESXi
: PowerEdge 系统上支持的操作系的安装和指导视频详细信息, Dell EMC PowerEdge 系统支持的操作系
www.dell.com/openmanagemanuals > OpenManage 部署工具包
www.dell.com/virtualizationsolutions

固件的选项

可以戴尔支持站点下固件。有更多信息,载驱动程序和固件
也可以选择以下任意一选项固件。有如何下固件的信息,表中提供的文接。
. 11: 下载固件的选项
选项
使用 Dell Remote Access Controller Lifecycle Controller (iDRAC with LC)
使用 Dell Repository Manager (DRM) www.dell.com/openmanagemanuals > Repository Manager
使用 Dell Server Update Utility (SUU) www.dell.com/openmanagemanuals > Server Update Utility
使用 Dell OpenManage Deployment Toolkit (DTK) www.dell.com/openmanagemanuals > OpenManage 部署工具包
使用 iDRAC www.dell.com/idracmanuals
www.dell.com/idracmanuals

安装操作系统驱动程序的选项

可以选择以下任意一选项安装操作系统驱动程序。有如何下或安装操作系统驱动程序的信息,阅表中提供的接。
. 12: 下载安装操作系统驱动程序的选项
选项 明文件
Dell EMC 支持站点 载驱动程序和固件部分。
iDRAC Integrated Dell Remote Access Controller User's Guide 址是:
https://www.dell.com/idracmanuals,而系特定的 Integrated
Dell Remote Access Controller User's Guide 址是:https://
www.dell.com/poweredgemanuals > 适用于的系品支持
面 > 明文件
22 初始系统设置和配置
. 12: 安装操作系统驱动程序的选项
选项 明文件
注: 要确定的平台的最新 iDRAC 版本和最新的文版本,
https://www.dell.com/support/article/
sln308699

载驱动程序和固件

在系上下安装最新的 BIOS驱动程序和系管理固件。
前提
确保页浏览器高速存,然后再下载驱动程序和固件。
1. www.dell.com/support/drivers
2. 入戴尔服务编Dell EMC ID 或型字段中入系的服务编,然后按 Enter。
注: 如果您没有服务编请选择检测 PC 以使系动检测务编,或单击浏览所有航至品。
3. 示的面上,单击驱动程序和下驱动程序和下面上,示适用于的所有驱动程序。
4. 驱动程序下 USB 驱动器、CD DVD
初始系
统设置和配置 23

装操作系管理用程序

使用系固件,可以在不引至操作系的情下管理系的基本置和功能。
用于管理操作系统应用程序的选项
可以使用以下任意一选项管理装操作系统应用程序:
统设
戴尔生命周期控制器
管理器
导执 (PXE)
统设
戴尔生命周期控制器
管理器
PXE
4

统设

使用统设选项可以配置 BIOS 置、iDRAC 置以及系设备设置。
可以使用以下界面之一访问统设置:
形用界面访问 iDRAC 控制面板,请单击配置,然后单击 BIOS
文本浏览浏览器通控制台重定向用。
统设,按 F2 ,然后单击统设置主菜
注: 如果按 F2 键之前已始载入操作系统,等待系统完成引导过程,然后重新动系统并重试。
统设置主菜详细信息如下所示:
. 13: 系统设置主菜
选项
统 BIOS 配置 BIOS 置。
iDRAC 配置 iDRAC 置。
iDRAC 设置置程序是一接口,用于使用 UEFI展固 件接口)置和配置 iDRAC 参数。可使用 iDRAC 用程序
用或禁用各 iDRAC 参数。有用程序的更多信息,Integrated Dell Remote Access Controller User’s Guide
址:www.dell.com/poweredgemanuals
设备设 控制器或卡等设备配置设备设置。

BIOS

统 BIOS 幕,、按 F2,然后单击 统设置主菜 > 统 BIOS
24 装操作系管理用程序
. 14: BIOS 详细信息
选项
信息 提供有的信息,如系BIOS 版本、服务编等。
存设 所安装存有的信息和选项
理器 理器有的信息和选项,如速度、高速存大小等。
SATA 示用于用或禁用集成 SATA 控制器和端口的选项
NVMe 示用于更改络设置的选项。如果系中包含的 NVMe 驱动想要配置在
RAID 列中,在此字段和嵌入式 SATA 字段中 SATA RAID 模式可能需要模式置更改UEFI。如果不是,则应此字段
RAID 模式。
导设 示各选项以指定引模式(BIOS UEFI)。支持修改 UEFI BIOS 导设
置。
络设 指定用于管理 UEFI 网络设置和引导协议选项
传统络设设备设受管。
注: BIOS 引模式下不支持“络设置”。
集成设备 示用于管理集成设备控制器和端口的选项,以及指定相的功能和选项
串行通信 示用于管理串行端口的选项,以及指定相的功能和选项
配置文件 示用于更改理器源管理置、率等等的选项
安全 示用于配置系安全置的选项,如系置密、可信平台模 (TPM)
安全和 UEFI 安全引可以管理系上的源按
冗余操作系控制 置冗余操作系控制的冗余操作系信息。
其他 指定更改系日期和时间选项
信息
信息幕,、按 F2,然后单击统设置主菜 > BIOS > 信息
. 15: 系统信息详细信息
选项
指定系的型
BIOS 版本 指定系上安装的 BIOS 版本。
务编 指定系务编
制造商 指定系制造商的名
制造商系人信息 指定系制造商的系信息。
CPLD 版本 指定系逻辑设备 (CPLD) 固件的前版本。
UEFI 性版本 指定系固件的 UEFI 性等
AGESA 版本 指定 AGESA 考代版本。
SMU 版本 指定 SMU 固件版本。
DXIO 版本 指定 DXIO 固件版本。
内存幕,、按 F2,然后单击系统设置主菜 > BIOS >
装操作系管理用程序 25
. 16: 详细信息
选项
存大小 指定系存大小。
指定系中安装的型。
存速度 指定系存速度。
电压 指定系电压
视频内存 指定视频存容量。
测试 指定系测试是否在系行。可能的选项包括已禁
。此选项认设已禁用
行模式 指定行模式。该选项可用,且默认设化器模式
行模式的 指定行模式的
存交叉存取 用或禁用存交叉存取选项。可用的两个选项为已禁用。此选项
认设
伺机自刷新 用或禁用伺机自刷新功能。此选项认设已禁用
正的错误日志记录 用或禁用可正的错误日志记录。此选项认设
理器
处理器幕,、按 F2,然后单击系统设置主菜 > BIOS > 理器
. 17: 理器详细信息
选项
逻辑处理器 理器核心最多支持两个逻辑处理器。如果此选项设
BIOS 示所有逻辑处理器。如果此选项设已禁BIOS 示每核心的一逻辑处理器。此选项认设
已启
化技 用或禁用的理器化技。此选项认设
IOMMU 支持 用或禁用 IOMMU 支持。需要 IVRS ACPI 表。此选项
L1 流硬件取器 用或禁用 L1 流硬件取器。此选项认设
L2 流硬件取器 用或禁用 L2 流硬件取器。此选项认设
MADT Core 指定 MADT Core 。此选项认设线
NUMA 指定每个插槽的 NUMA 。此选项认设 1
CCX NUMA 用或禁用“CCX NUMA 。此选项认设已禁用
最小 SEV-ES ASID 确定安全加密的虚拟 ES 和非 ES 可用地址空 ID 量。此
选项认设1
x2APIC 模式 用或禁用 x2APIC 模式。此选项认设
理器 CCD 控制每理器中的已 CCD 。此选项认设全部
CCD 核心 指定每 CCD 的核心。此选项认设全部
理器核心速度 理器的最大核心率。
理器 n
26 预装操作系管理用程序
注: 根据 CPU 数量,最多可能会列出 n 处理器。
以下仅对中安装的每理器示:
. 18: 处理器 n 详细信息
选项
系列、型和步 指定 AMD 理器系列、型和步
品牌 示品牌名
2 高速 L2 高速和。
3 高速 L3 高速和。
示每理器的
指定理器微版本。
SATA 设置
SATA 设置幕,、按 F2,然后单击系统设置主菜 > BIOS > SATA
. 19: SATA 详细信息
选项
嵌入式 SATA 支持嵌入式 SATA 选项设AHCI 模式RAID 模式。此选项认设
AHCI 模式
注:
1. 您可能需要模式置更改 UEFI。否此字段 RAID 模 式。
2. RAID 模式下不支持 ESXi Ubuntu 操作系
安全冻结锁 机自测过程中安全冻结锁定命令嵌入式 SATA 驱动器。此选项仅适用于
AHCI 模式。此选项认设已启
入高速 POST 程中用或禁用嵌入式 SATA 驱动器的命令。此选项认设已禁用
端口 n 置所选设备驱动型。
AHCI 模式RAID 模式用 BIOS 支持。
. 20: 端口 n
选项
指定所选设备驱动器型
驱动 指定接至 SATA 端口的驱动型。
容量 指定驱动器的容量。于可移质设
,如光,此字段未定
NVMe
选项 NVMe 驱动器模式。如果系中包含想要在 RAID 列中配置的 NVMe 驱动器, SATA 置菜上的此字 段和嵌入式 SATA”字段 RAID 模式。可能需要的模式置更改 UEFI该选项认设 RAID 模式。
导设
可以使用导设模式BIOS UEFI指定引导顺序。
UEFI:一可展固件接口( UEFI )都是一新接口之的操作系和平台固件。接口中包含据表和平台相信息,以及操作
及其加程序可用的引呼叫。以下参数配置文件自定才可用。
支持大于 2 TB 的驱动器分增强的安全性(例如, UEFI 安全引导)更快的引导时间
: 必须使用 UEFI 引导模式,以便 NVMe 驱动行引
装操作系管理用程序 27
BIOS:BIOS 模式传统模式。此位置支持向后兼容性。
导设幕,、按 F2,然后单击统设置主菜 > BIOS > 导设
. 21: 导设详细信息
选项
模式 置系的引模式。如果操作系支持 UEFI选项设 UEFI
此字段 BIOS 后,可 UEFI 操作系兼容。该选项认设UEFI
小心: 如果操作系统不是在同一模式下安装,模式可能阻止系
注: 将此字段 UEFI 将禁用 BIOS 引导设置菜
导顺序重 用或禁用引导顺序重功能。如果用此字段后系,系 30 秒后重
尝试导顺序。此选项认设为已
故障切 用或禁用硬故障切。此选项认设已禁用
通用 USB 用或禁用通用 USB 占位符。此选项认设已禁用
占位符 用或禁用硬占位符。此选项认设已禁用
UEFI 导设 指定 UEFI 导顺序。用或禁用 UEFI 导选项
注:选项控制 UEFI 引导顺序。首先尝试列表中的第一选项
. 22: UEFI 导设
选项
UEFI 导顺 更改引导设备序。
导选项/禁用 选择用或已禁用的引导设
选择模式
统设置程序也能指定其中一用于安装操作系的引模式:
UEFI 模式(默)是增强版 64 位引接口。
如果配置 UEFI 模式, BIOS
1. 单击统设置程序主菜中的导设,然后选择模式
2. 选择希望系至的 UEFI 引模式。
小心: 如果操作系不是在同一模式下安装,模式可能阻止系
3. 在系以指定引模式引后,模式安装操作系
: 操作系 UEFI 兼容才能 UEFI 模式安装。DOS 32 位操作系不支持 UEFI,只能通 BIOS 模式
安装。
注:支持的操作系的最新信息,请转www.dell.com/ossupport
更改引导顺
于此任
如果 USB 或光可能需要更改引导顺序。如果选择BIOS Boot Mode(引模式),处给出的 明可能有所不同。
注: 只有在 BIOS 引模式下才支持更改驱动器引导顺序。
1. 统设置主菜幕上,单击 BIOS > 导设置 > UEFI 导设置 > UEFI 导顺
2. 使用箭头键选择导设备,然后使用加号 (+) 减号 (-) 将设备序向下或向上移
28
装操作系管理用程序
3. 单击退出,然后单击以在退出后保存置。
注: 还可以根据需要启用或禁用引导顺设备
络设置
络设置幕,,按 F2,然后单击系统设置主菜 > BIOS > 络设
注: Linux 络性能设置的信息,请
AMD.com
注: BIOS 引模式下不支持“络设置”。
. 23: 络设详细信息
选项
UEFI PXE 控制 UEFI PXE 设备的配置。
PXE 设备 n (n = 1 to 4) 用或禁用此设备则为设备创 UEFI PXE 导选项
PXE 设备 n (n = 1 to 4) 控制 PXE 设备的配置。
UEFI HTTP 控制 UEFI HTTP 设备的配置
HTTP 设备 n (n = 1 to 4) 用或禁用此设备则为设备创 UEFI HTTP 导选项
HTTP 设备 n (n = 1 to 4) 控制 HTTP 设备的配置。
UEFI iSCSI 控制 iSCSI 设备的配置。
Linux Network Tuning Guide for AMD EPYC Processor Based Servers
址:
. 24: PXE 设备 n 详细信息
选项
界面 确定用于 PXE 设备 NIC 接口。
协议 指定用于 PXE 设备协议。此选项设 IPv4 IPv6。此选项认设 IPv4
Vlan PXE 设备 Vlan。此选项设禁用。此选项认设禁用
Vlan ID PXE 设备 Vlan ID
Vlan PXE 设备 Vlan
. 25: HTTP 设备 n 详细信息
选项
界面 指定用于 HTTP 设备 NIC 接口。
协议 指定用于 HTTP 设备协议。此选项设 IPv4 IPv6。此选项认设 IPv4
Vlan HTTP 设备 Vlan。此选项设禁用。此选项认设禁用
Vlan ID HTTP 设备 Vlan ID
Vlan HTTP 设备 Vlan
DHCP HTTP 设备用或禁用 DHCP。此选项认设
IP 地址 指定 HTTP 设备 IP 地址。
指定 HTTP 设备的子
网关 指定 HTTP 设备网关
DHCP 用或禁用 DNS信息从 DHCP 用或禁用 DNS 信息。此选项认设启用
主要 DNS 指定 HTTP 设备的主 DNS IP 地址。
次要 DNS 指定 HTTP 设备 DNS IP 地址。
装操作系管理用程序 29
. 25: HTTP 设备 n 详细信息 (
选项
URI 如果未指定, DHCP URI
. 26: UEFI iSCSI 设详细信息
选项
iSCSI 器名 指定 iSCSI 器的名IQN 格式)。
iSCSI 设备 1 用或禁用 iSCSI 设备。禁用后, iSCSI 设备动创 UEFI 导选项。此选项认设
已禁用
iSCSI 设备 1 设置 控制 iSCSI 设备的配置。
. 27: ISCSI 设备设详细信息
选项
1 用或禁用 iSCSI 接。此选项认设禁用
2 用或禁用 iSCSI 接。此选项认设禁用
1 控制 iSCSI 接的配置。
2 控制 iSCSI 接的配置。
控制尝试进 iSCSI 接的序。
集成设备
集成设备幕,、按 F2,然后单击系统设置主菜 > BIOS > 集成设备
. 28: 集成设备详细信息
选项
访问 USB 端口 禁用前端用访问 USB 端口。选择仅开启背面端口禁用正面 USB 端口;选择
所有端口禁用所有正面和背面 USB 端口;选择 所有端口(动态 POST 禁用所有正面和背面 USB 端口。此选项认设打开所有端口
访问 USB 端口所有端口(动态用正面端口选项 禁用。
用正面端口:在操作系用或禁用正面 USB 端口。
在引导过程中 USB 键盘和鼠在某些 USB 端口中仍可正常工作,具体取 。引导过程完成后,USB 端口根据用或禁用。
USB 端口 用或禁用 USB 端口。此选项设。此选项认设
iDRAC Direct USB 端口 iDRAC Direct USB 端口由 iDRAC 专门管理,主机不可。此选项设
iDRAC 无法检测到此管理端口中安装的任何 USB 设备。此选项 认设
集成 RAID 控制器 用或禁用集成 RAID 控制器。此选项认设
嵌入式 NIC1 NIC2 用或禁用嵌入式 NIC1 NIC2 选项已禁用 (OS) NIC 仍可用于
嵌入式管理控制器的共享络访问。通使用系 NIC 管理用程序配置嵌入 式 NIC1 NIC2 选项
嵌入式视频控制器 用或禁用嵌入式视频控制器主要的使用。,嵌入
视频控制器用作主示器,即使已安装附加式卡。已禁用,附 加式用作主示器。BIOS 机自检过程中和导环境中 两个主要附加式视频和嵌入式视频。在操作系之前,嵌入式视频立即被 禁用。此选项认设
注: 当系中已安装附加式,在 PCI 枚举过程中找到的第一卡已
中作视频可能需要重新排列槽中的卡,以便控制卡是主
30 预装操作系管理用程序
Loading...
+ 127 hidden pages