Dell PowerEdge R210 II User Manual [in]

Page 1
Dell PowerEdge
R210 II Systems
Getting Started
With Your System
系统使用入门
Memulai Dengan Sistem Anda
はじめに
시스템 시작 안내서
Page 2
Page 3
Dell PowerEdge
R210 II Systems
Getting Started
With Your System
Page 4
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data
if instructions are not followed.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
___________________
Information in this publication is subject to change without notice. © 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc.
®
is a registered trademark and Core™ is a trademark of Intel Corporation in the U.S. and
Intel other countries. Microsoft of Microsoft Corporation in the United States and/or other countries. Red Hat
®
Linux
and are registered trademarks of Red Hat, Inc. in the United States and/or other countries. SUSE ™ is a trademark of Novell, Inc. in the United States and other countries. Citrix XenServer and/or other countries. VMware United States or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
®
are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States
®
and Windows Server® are either trademarks or registered trademarks
®
is a registered trademarks or trademark of VMWare, Inc. in the
®
and Red Hat Enterprise
®
and
Regulatory Model E10S Series
December 2010 P/N 30G7N Rev. A00
Page 5

Installation and Configuration

WARNING: Before performing the following procedure, review the safety
instructions that came with the system.

Unpacking the System

Unpack your system and identify each item.

Installing the Rails and System in a Rack

CAUTION: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
For more information, see
"Technical Specifications" on page 9.
Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.
Getting Started With Your System 3
Page 6
Optional—Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.

Connecting the Power Cable

Connect the system’s power cable to the system and, if a monitor is used, connect the monitor’s power cable to the monitor.
4 Getting Started With Your System
Page 7

Securing the Power Cable

Bend the system power cable as shown in the illustration and secure the cable in the retention clip.
Plug the other end of the power cable into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).

Turning On the System

Press the power button on the system and the monitor. The power indicators should light.
Getting Started With Your System 5
Page 8

Installing the Optional Bezel

Install the bezel (optional).

Complete the Operating System Setup

If you purchased a preinstalled operating system, see the operating system documentation that ships with your system. To install an operating system for the first time, see the installation and configuration documentation for your operating system. Be sure the operating system is installed before installing hardware or software not purchased with the system.

Supported Operating Systems

Microsoft Small Business Server 2011 Standard and Essential Editions
Microsoft Windows Server 2008 R2 SP1 (x64) Web, Standard, Foundation, and Enterprise Editions
Microsoft Windows and Enterprise Editions
Microsoft Windows Server 2008 SP2 (x86) Web, Standard, and Enterprise Editions
Microsoft Windows Server 2008 SP2 (x64) Web, Standard, and Enterprise Editions
Microsoft Windows Server 2008 R2 SP1(x64) with Hyper-V for Standard and Enterprise Editions
6 Getting Started With Your System
Server 2008 R2 (x64) Web, Standard, Foundation,
Page 9
Microsoft Windows Server 2008 R2 (x64) with Hyper-V for Standard and Enterprise Editions
Microsoft Windows Server 2008 SP2 (x64) with Hyper-V for Standard and Enterprise Editions
VMware ESX 4.1 Update 1 (Classic)
VMware ESX 4.1 Update 1 (Embedded)
Citrix XenServer 5.6 Feature Pack 1
Red Hat Enterprise Linux
SUSE Linux Enterprise Server 11 SP1 (x86_64)
NOTE: For the latest information on supported operating systems,
see support.dell.com.
6.0 (x86_64)

Dell Software License Agreement

Before using your system, please read the Dell Software License Agreement that came with your system.
You must consider any CD, DVD, or diskette set of Dell installed software as BACKUP copies of the software installed on your system's hard-disk drive.
If you do not accept the terms of the agreement, please call the customer assistance telephone number. For customers in the United States, call 800-WWW-DELL (800-999-3355). For customers outside the United States, visit from the top of the page.
support.dell.com
and select your country or region
Getting Started With Your System 7
Page 10

Other Information You May Need

WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document or as a separate document.
The rack documentation included with your rack solution describes how to install your system into a rack.
•The
Any media that ships with your system that provides documentation and
Owner’s Manual
and describes how to troubleshoot the system and install or replace system components. This document is available online at
support.dell.com/manuals
tools for configuring and managing your system, including those pertaining to the operating system, system management software, system updates, and system components that you purchased with your system.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
provides information about system features
.

Obtaining Technical Assistance

If you do not understand a procedure in this guide or if the system does not perform as expected, see your Owner’s Manual. Dell offers comprehensive hardware training and certification. See dell.com/training for more information. This service may not be offered in all locations.
8 Getting Started With Your System
Page 11

Información de la NOM (sólo para México)

La información que se proporciona a continuación aparece en el dispositivo descrito en este documento, en cumplimiento de los requisitos de la Norma Oficial Mexicana (NOM):
Importador:
Número de modelo: E10S Voltaje de alimentación: 100 V CA-240 V CA Frecuencia: 50 – 60 Hz Consumo eléctrico: 4,0 - 2,0 A

Technical Specifications

Processor
Processor type One Intel Core processor i3-2100 product family
or One Intel Xeon processor E3-1200 product family or One Intel Pentium processor (when available)
Expansion Bus
Bus type PCI Express Generation 2
Expansion slots One full-height, half-length x16 link
Memory
Architecture 1066 MHz and 1333 MHz DDR3 unbuffered
Error Correcting Code (ECC) DIMMs
Memory module sockets Four 240-pin
Memory module capacities 1 GB, 2 GB, 4 GB, or 8 GB
Minimum RAM 1 GB
Maximum RAM 32 GB
Getting Started With Your System 9
Page 12
Drives
Hard drives Up to two 3.5-inch cabled SAS or SATA
internal drives or Up to two 2.5-inch cabled SAS or SATA internal drives
Optical drive One optional internal SATA DVD-ROM or
DVD+/-RW drive
NOTE: DVD devices are data only.
Optional external USB DVD-ROM
Connectors
Back
NIC
Serial
USB
Video
eSATA
Front
Video
USB
Internal
USB
Two RJ-45 (for integrated 1 GB NICs)
9-pin, DTE, 16550-compatible
Two 4-pin, USB 2.0-compliant
15-pin VGA
One 7-pin connector
15-pin VGA
Two 4-pin, USB 2.0-compliant
Two 4-pin, USB 2.0-compliant
Video
Video type Matrox G200, integrated in Winbond WPCM450
Video memory 8 MB
10 Getting Started With Your System
Page 13
Power
AC power supply (per power supply)
Wattage
Vo lt ag e
Heat dissipation
Maximum inrush current
Batteries
System battery
Physical
Height 4.24 cm (1.67 inches)
Width 43.4 cm (17.09 inches)
Depth 39.37 cm (15.5 inches)
Weight (maximum configuration)
Environmental
250 W
100 VAC–240 VAC, 50 Hz/60 Hz, 4.0 A–2.0 A
1040 BTU/hr maximum
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 A
CR 2032 3.0-V lithium coin cell
8.058 kg (17.77 lb)
NOTE: For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Temperature
Operating
10 °C to 35 °C (50 °F to 95 °F) with a maximum temperature gradation of 10 °C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
Storage
Relative humidity
Operating
Storage
–40 °C to 65 °C (–40 °F to 149°F) with a maximum temperature gradation of 20 °C per hour
20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
5% to 95% (noncondensing)
Getting Started With Your System 11
Page 14
Environmental (continued)
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
0.26 Grms at 5 Hz–350 Hz for 15 min
1.87 Grms at 10 Hz–500 Hz for 15 min
One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (686 centimeters/second)
–16 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
–16 m to 10,600 m (–50 ft to 35,000 ft)
G1 as defined by ISA-S71.04-1985
12 Getting Started With Your System
Page 15
Dell PowerEdge
R210 II 系统

系统使用入门

管制型号:
E10S
系列
Page 16
注、小心和警告
注:“注”表示可以帮助您更好地使用计算机的重要信息。
小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据
丢失。
警告:
___________________
本出版物中的信息如有更改,恕不另行通知。
© 2010 Dell Inc.
未经
Dell Inc.
本文中使用的商标:
分别是
Core
Windows Server Red Hat
商标。
SUSE
Systems, Inc.
在美国或其它国家/地区的注册商标。
本出版物中述及的其它商标和商品名称是指拥有相应商标和商品名称的公司或其产品。
Dell Inc.
“警告”表示可能会造成财产损失、人身伤害甚至死亡。
版权所有,翻印必究。
书面许可,严禁以任何形式复制这些材料。
Dell
Intel Corporation
®
®
是 Microsoft Corporation
和 Red Hat Enterprise Linux® 是 Red Hat, Inc.
是 Novell Inc.
在美国和/或其它国家/地区的注册商标或商标。
对其它公司的商标和产品名称不拥有任何所有权。
DELL
在美国和其它国家/地区的商标。
徽标和
在美国 和其它国家/地区的注册商标和商标。
PowerEdge
在美国和/或其它国家/地区的商标或注册商标。
是 Dell Inc.
在美国和/或其它国家/地区的注册
Citrix® 和 XenServer® 是 Citrix
VMware
的商标。
®
Intel® 和
Microsoft® 和
是 VMware, Inc.
管制型号
2010 年 12 月 P/N 30G7N Rev. A00
E10S
系列
Page 17

安装和配置

警告: 执行下列步骤之前,请查看系统随附的安全说明。

打开系统包装

打开系统包装并检查各个组件。

在机架中安装滑轨和系统

小心:如果安装在封闭的或多单元机架部件中,机架周围的操作环境温度可
能高于室温。所以,应当考虑将设备安装在与制造商指定的最高环境温度
兼容的环境中。
(TMA)
有关详情,请参阅
页的“技术规格”。
21
遵循系统随附的安全说明和机架安装说明,在机架中组装滑轨并安装系统。
系统使用入门 15
Page 18
可选 — 连接键盘、鼠标和显示器
连接键盘、鼠标和显示器(可选)。 系统背面的连接器附有图标,这些图标指示了要插入每个连接器的电缆。
确保拧紧显示器的电缆连接器上的螺钉(如果有)。

连接电源电缆

将系统电源电缆连接至系统,如果使用显示器,将显示器电源电缆连接至显 示器。
16 系统使用入门
Page 19

固定电源电缆

如图所示,将系统电源电缆弯曲图中的形状,并使用固定夹固定好电缆。 将电源电缆的另一端插入接地的电源插座或单独的电源,如不间断电源设备
(UPS)
或配电装置
(PDU)

开启系统

按下系统和显示器的电源按钮。电源指示灯将会亮起。
系统使用入门 17
Page 20

安装可选挡板

安装挡板(可选)。

完成操作系统安装

如果购买了预安装的操作系统,请参阅系统随附的操作系统说明文件。第一 次安装操作系统时,请参阅操作系统的安装和配置说明文件。请确保先安装 操作系统,然后再安装未随系统一起购买的硬件或软件。

支持的操作系统

Microsoft Small Business Server 2011 Standard
Microsoft Windows Server 2008 R2 SP1 (x64) Web Foundation
Microsoft Windows
版及
Microsoft Windows Server 2008 SP2 (x86) Web
Enterprise
Microsoft Windows Server 2008 SP2 (x64) Web
Enterprise
具有
Standard
具有
Enterprise
18 系统使用入门
版及
Enterprise
Server 2008 R2 (x64) Web、Standard、Foundation
Enterprise
Hyper-V 的 Microsoft Windows Server 2008 R2 SP1 (x64)
版及
Hyper-V 的 Microsoft Windows Server 2008 R2 (x64) Standard 版及
Enterprise
版及
Essential
Standard
Standard
Standard
版 、
Page 21
具有
Hyper-V 的 Microsoft Windows Server 2008 SP2 (x64) Standard
Enterprise
VMware ESX 4.1 Update 1
VMware ESX 4.1 Update 1
Citrix XenServer 5.6 Feature Pack 1
Red Hat Enterprise Linux
SUSE Linux Enterprise Server 11 SP1 (x86_64)
注:有关支持的操作系统的最新信息,请访问 support.dell.com
软件许可协议
Dell
在使用您的系统前,请阅读系统随附的
您必须将 盘驱动器上安装的软件的备份副本。
如果您不接受协议条款,请拨打客户帮助电话号码。美国地区的 客户,请致电 请访问
(经典) (嵌入式)
6.0 (x86_64)
安装的软件的任何
Dell
800-WWW-DELL (800-999-3355)
support.dell.com
并从页面顶部选择您的国家或地区。
Dell
CD、DVD
软件许可协议。
或套装软盘视为您系统硬
。美国以外的客户,
版及
系统使用入门 19
Page 22

可能需要的其它信息

警告: 请参阅系统附带的安全与管制信息。保修信息可能包括在该说明文
件中,也可能作为单独的说明文件提供。
机架解决方案附带机架说明文件,介绍了如何将系统安装到机架中。
《用户手册》提供了有关系统功能的信息,并说明了如何排除系统故 障以及安装或更换系统组件。可在 该说明文件。
系统随附的所有介质都提供了用于配置和管理系统的说明文件和 工具,包括与随系统购买的操作系统、系统管理软件、系统更新以及 系统组件相关的说明文件和工具。
注:请经常访问 support.dell.com/manuals 以获得更新,并首先阅读这
些更新,因为这些更新通常会取代其它说明文件中的信息。
support.dell.com/manuals
在线获取

获得技术帮助

如果您对本指南中的步骤有疑问,或系统运行无法达到预期效果,请参阅 《用户手册》
dell.com/training
提供全面的硬件培训和认证。有关详情,请参阅
Dell
。此项服务可能并非在所有地区都提供。
20 系统使用入门
Page 23

技术规格

处理器
处理器类型 一个
扩充总线
总线类型
扩充槽 一个全高、半长
内存
架构
内存模块插槽 四个
内存模块容量
最小
RAM
最大
RAM
驱动器
硬盘驱动器 至多两个
光盘驱动器
Intel Core
或 一个
Intel Xeon
或 一个
Intel Pentium
PCI Express 第 2
1066 MHz 或 1333 MHz DDR3
代码
(ECC) DIMM
针插槽
240
1 GB、2 GB、4 GB 或 8 GB
1 GB
32 GB
英寸已连接电缆的
3.5
部驱动器 或 至多两个 部驱动器
一个可选的内部
驱动器
RW
英寸已连接电缆的
2.5
注:DVD 设备仅用于数据。
可选的外部
USB DVD-ROM
处理器
i3-2100
处理器
E3-1200
处理器(如果可用)
链路
x16
SATA DVD-ROM 或 DVD+/-
产品系列
产品系列
非缓冲错误纠正
SAS 或 SATA
SAS 或 SATA
系统使用入门 21
Page 24
连接器
背面
NIC
串行
USB
视频
eSATA
正面
视频
USB
内部
USB
视频
视频类型 集成在
视频内存
电源
交流电源设备(每个电源设备)
功率
电压
散热
最大涌入电流
电池
系统电池
两个
RJ-45
9 针、DTE、16550
两个
4 针、USB 2.0
15 针 VGA
一个
7
15 针 VGA
两个
4 针、USB 2.0
两个
4 针、USB 2.0
8 MB
250 W
100 VAC–240 VAC,50 Hz/60 Hz
4.0 A–2.0 A
最大为
在典型的线路条件下和整个系统运行范围内, 涌入电流可达
CR 2032 3.0 V
(用于集成的
针连接器
Winbond WPCM450 中的 Matrox G200
1040 BTU/
25 A
币形锂电池
1 GB NIC
兼容
兼容
兼容
兼容
小时
22 系统使用入门
Page 25
物理规格
高度
宽度
厚度
重量(最大配置)
环境参数
4.24
43.4
39.37
8.058
厘米(
厘米(
厘米(
公斤(
1.67
17.09
15.5
17.77
英寸)
英寸)
英寸)
磅)
注:有关特定系统配置的环境测量值的其它信息,请参阅
dell.com/environmental_datasheets
温度
运行时
10 °C 至 35 °C(50 °F 至 95 °F
度变化梯度为每小时
10 °C
注:海拔高度在 2950 英尺以上时,最高操作温
度按 1 °F/550 英尺降低
存储时
相对湿度
运行时
存储时
最大振动
运行时
存储时
40 °C 至 65 °C
最大温度变化梯度为每小时
20% 至 80%
每小时
5% 至 95%
5 Hz - 350 Hz、0.26 Grms
分钟
15
10 Hz - 500 Hz、1.87 Grms
分钟
15
(非冷凝),最大湿度变化梯度为
10%
(非冷凝)
(–
),最大温
40 °F 至 149°F
20 °C
时,可持续
时,可持续
),
系统使用入门 23
Page 26
环境参数 (续)
最大撞击
运行时
存储时
海拔高度
运行时
存储时
气载污染物级别
级别
在操作方向,z 轴正方向可承受一个 击脉冲(系统每一面承受一个脉冲),可持续
毫秒
2.6
x、y 和 z
撞击脉冲(系统每一面承受一个脉冲),最长 可持续
x、y 和 z
正弦波脉冲(系统每一面承受一个脉冲), 速度变化为
轴正负方向上可承受连续六个
毫秒
2
轴正负方向上可承受连续六个
英寸/秒(
270
16 米至 3048 米(-50
686
英尺至
厘米/秒)
10,000
31 G
71 G
32 G
英尺)
的撞
注:海拔高度在 2950 英尺以上时,最高操作温
度按 1 °F/550 英尺降低
16 米至 10,600 米(-50
(依据
G1
ISA-S71.04-1985
英尺至
35,000
定义的标准)
英尺)
24 系统使用入门
Page 27
Sistem Dell PowerEdge
R210 II
Memulai Dengan
Sistem Anda
Model Resmi Seri E10S
Page 28
Catatan, Perhatian, dan Peringatan
CATATA N: CATATAN menunjukkan informasi penting yang membantu Anda untuk
menggunakan komputermembantu Anda untuk menggunakan komputer dengan lebih baik.
PERHATIAN: PERHATIAN menunjukkan kemungkinan kerusakan pada perangkat
keras atau hilangnya data jika Anda tidak mengikuti instruksi yang diberikan.
PERINGATAN: PERINGATAN menunjukkan kemungkinan kerusakan pada harta
benda, cedera diri, atau kematian.
___________________
Informasi di dalam publikasi ini dapat berubah tanpa pemberitahuan. © 2010 Dell Inc. Hak Cipta Dilindungi Undang-Undang
Dilarang keras mereproduksi materi ini dalam cara apapun tanpa izin tertulis dari Dell Inc.
Merek dagang yang digunakan dalam teks ini: Dell™, logo DELL, dan PowerEdge™, adalah merek dagang dari Dell Inc. Intel Corporation di AS. dan negara-negara lain. Microsoft dagang atau merek dagang terdaftar dari Microsoft Corporation di Amerika Serikat dan/atau negara­negara lain. Red Hat di Amerika Serikat dan/atau negara-negara lain. SUSE™ adalah merek dagang terdaftar dari Novell, Inc. di Amerika Serikat dan negara-negara lain. Citrix terdaftar atau merek dagang dari Citrix Systems, Inc. di Amerika Serikat dan/atau negara-negara lain.
®
VMware negara lain.
Merek dagang dan nama dagang lain mungkin digunakan dalam publikasi ini untuk merujuk ke pihak lain yang memiliki merek dan nama terkait atau produk mereka. Dell Inc. menafikan kepentingan kepemilikan apa pun atas merek dagang dan nama dagang selain miliknya sendiri.
adalah merek dagang terdaftar dari VMware, Inc. di Amerika Serikat dan/atau negara-
®
adalah merek dagang terdaftar dan Core™ adalah merek dagang dari Intel
®
dan Red Hat Enterprise Linux® adalah merek dagang terdaftar dari Red Hat, Inc.
®
dan Windows Server® merupakan merek
®
dan XenServer® adalah merek dagang
Model Resmi Seri E10S
Desember 2010 No. Komp. 30G7N Rev. A00
Page 29

Instalasi dan Konfigurasi

PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk
keselamatan yang disertakan dengan sistem.

Membuka Kemasan Sistem

Buka kemasan sistem Anda dan kenali setiap komponen.

Memasang Rel dan Sistem dalam Rak

PERHATIAN: Jika dipasang pada rakitan rak multi-unit atau rak tertutup, suhu
pengoperasian sekitar rak dapat menjadi lebih tinggi daripada suhu ruangan. Oleh karena itu, Anda disarankan untuk memasang peralatan di lingkungan yang sesuai dengan suhu sekitar maksimal (Tma) yang ditentukan oleh produsen.
informasi lebih lanjut, lihat
"Spesifikasi Teknis" di halaman 33.
Untuk
Rakit rel dan pasang sistem dalam rak sesuai dengan petunjuk keselamatan dan petunjuk pemasangan rak yang disertakan bersama sistem Anda.
Memulai Dengan Sistem Anda 27
Page 30
Opsional—Menghubungkan Keyboard, Mouse, dan Monitor
Hubungkan keyboard, mouse, dan monitor (opsional).
Konektor di bagian belakang sistem Anda memiliki ikon yang menunjukkan kabel mana yang harus disambungkan ke setiap konektor. Pastikan baut (jika ada) dikencangkan pada konektor kabel monitor.

Menghubungkan Kabel Daya

Hubungkan kabel daya sistem ke sistem dan, jika monitor digunakan, hubungkan kabel daya monitor ke monitor.
28 Memulai Dengan Sistem Anda
Page 31

Mengamankan Kabel Daya

Bengkokkan kabel daya sistem seperti tampak pada gambar dan tahan kabel dengan klip penahan.
Sambungkan ujung lain kabel daya ke stopkontak listrik yang telah terhubung ke ground atau ke sumber daya yang terpisah seperti catu daya tak terputus (UPS) atau unit distribusi daya (PDU)

Menyalakan Sistem

Tekan tombol daya pada sistem dan monitor. Indikator daya harus menyala.
Memulai Dengan Sistem Anda 29
Page 32

Memasang Bingkai Opsional

Pasang bingkai (opsional).

Menyelesaikan Pemasangan Sistem Operasi

Jika Anda membeli sistem operasi yang telah diinstal sebelumnya, lihat dokumentasi sistem operasi yang dikirimkan bersama sistem Anda. Untuk menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi dan konfigurasi untuk sistem operasi Anda. Pastikan bahwa sistem operasi telah diinstal sebelum Anda menginstal perangkat keras atau perangkat lunak yang tidak dibeli bersama sistem.

Sistem Operasi Yang Didukung

Microsoft Small Business Server 2011 Edisi Standard dan Essential
Microsoft Windows Server 2008 R2 SP1 (x64) Web, Edisi Standard, Foundation, dan Enterprise
Microsoft Windows Foundation, dan Enterprise
Microsoft Windows Server 2008 SP2 (x86) Web, Edisi Standard, dan Enterprise
Microsoft Windows Server 2008 SP2 (x64) Web, Edisi Standard, dan Enterprise
30 Memulai Dengan Sistem Anda
Server 2008 R2 (x64) Web, Edisi Standard,
Page 33
Microsoft Windows Server 2008 R2 SP1(x64) dengan Hyper-V untuk Edisi Standard dan Enterprise Editions
Microsoft Windows Server 2008 R2 (x64) dengan Hyper-V untuk Edisi Standard and Enterprise
Microsoft Windows Server 2008 SP2 (x64) dengan Hyper-V untuk Edisi Standard dan Enterprise
VMware ESX 4.1 Update 1 (Classic)
VMware ESX 4.1 Update 1 (Embedded)
Citrix XenServer 5.6 Feature Pack 1
Red Hat Enterprise Linux
SUSE Linux Enterprise Server 11 SP1 (x86_64)
NOTE: Untuk informasi terbaru mengenai sistem operasi yang didukung,
kunjungi support.dell.com.
6.0 (x86_64)

Perjanjian Lisensi Perangkat lunak Dell

Sebelum menggunakan sistem Anda, silakan baca Perjanjian Lisensi Perangkat Lunak Dell yang disertakan bersama sistem Anda.
Anda harus menganggap CD, DVD, atau disket apapun dari perangkat lunak Dell yang telah diinstal sebagai salinan CADANGAN dari perangkat lunak yang diinstal pada hardi-disk drive sistem Anda.
Jika Anda tidak menerima syarat perjanjian ini, silakan hubungi nomor telepon bantuan pelanggan. Untuk pelanggan di Amerika Serikat, hubungi 800-WWW-DELL (800-999-3355). Untuk pelanggan di luar Amerika Serikat, silakan kunjungi wilayah Anda dari bagian atas halaman.
support.dell.com
dan pilih negara atau
Memulai Dengan Sistem Anda 31
Page 34

Informasi Lain Yang Mungkin Anda Perlukan

PERINGATAN: Lihat informasi keselamatan dan peraturan yang dikirimkan
bersama dengan sistem Anda. Informasi jaminan mungkin disertakan di dalam dokumen ini atau sebagai suatu dokumen terpisah.
Dokumentasi rak yang tercakup dalam solusi rak Anda menjelaskan bagaimana cara memasang sistem ke dalam rak.
Panduan Pemilik Komputer
• sistem dan menjelaskan cara memecahkan kesalahan sistem dan memasang atau mengganti komponen sistem. Dokumen ini tersedia secara online di
Media apa pun yang dikirimkan bersama dengan sistem Anda yang memberi dokumentasi dan alat untuk mengonfigurasikan dan mengelola sistem Anda termasuk yang berhubungan dengan sistem operasi, perangkat lunak manajemen sistem, pembaruan sistem, dan komponen sistem yang Anda beli bersama sistem Anda.
NOTE: Selalu periksa ketersediaan pembaruan di situs
support.dell.com/manuals dan baca pembaruan tersebut terlebih dahulu karena biasanya pembaruan tersebut sering kali menggantikan informasi dalam dokumen.
support.dell.com/manuals
menyediakan informasi mengenai fitur-fitur
.

Mendapatkan Bantuan Teknis

Jika Anda tidak memahami prosedur dalam panduan ini atau jika sistem tidak beroperasi seperti yang diharapkan lihat Panduan Pemilik Komputer yang Anda terima. Dell menyediakan pelatihan dan sertifikasi perangkat keras secara menyeluruh. Lihat dell.com/training untuk informasi lebih lanjut. Layanan ini mungkin tidak tersedia di semua lokasi.
32 Memulai Dengan Sistem Anda
Page 35

Spesifikasi Teknis

Prosesor
Tipe prosesor Sebuah produk prosesor keluarga Intel Core
i3-2100 atau Sebuah produk prosesor keluarga Intel Xeon E3-1200 atau Sebuah prosesor Intel Pentium (jika ada)
Bus Ekspansi
Tipe bus PCI Express Generasi 2
Slot ekspansi Satu slot dengan ketinggian penuh, setengah
panjang, link x16
Memori
Arsitektur DIMM DDR3 1066-MHz atau 1333-MHz dengan
Kode Mengoreksi Kesalahan (ECC) tanpa buffer.
Soket modul memori Empat 240-pin
Kapasitas modul memori 1 GB, 2 GB, 4 GB, atau 8 GB
RAM minimum 1 GB
RAM maksimum 32 GB
Drive
Hard drive Sampai dua drive internal berukuran 3.5-inch
menggunakan kabel SAS atau SATA atau Sampai dua drive internal berukuran 2.5-inch berkabel SAS atau SATA
Drive optis Sebuah drive DVD-ROM atau DVD+/-RW SATA
internal opsional
CATATA N: Perangkat DVD hanya data.
USB DVD-ROM eksternal opsional
Memulai Dengan Sistem Anda 33
Page 36
Konektor
Belakang
NIC
Serial
USB
Video
eSATA
Depan
Video
USB
Internal
USB
Video
Tipe video Matrox G200, terpadu pada Winbond WPCM450
Memori video 8 MB
Daya
Catu daya AC (per catu daya)
Watt D a ya
Te ga n ga n
Pelepasan panas
Lonjakan arus maksimum
Baterai
Baterai sistem
Dua RJ-45 (untuk NIC terpadu 1GB)
9 pin, DTE, kompatibel dengan 16550
Dua konektor 4 pin untuk USB 2.0
VGA 15 pin
Sebuah konektor 7-pin
VGA 15 pin
Dua konektor 4 pin untuk USB 2.0
Dua konektor 4 pin untuk USB 2.0
250 W
100 VAC–240 VAC, 50 Hz/60 Hz, 4,0 A–2,0 A
1040 BTU/jam maksimum
Di bawah kondisi listrik yang biasanya ada dan di dalam seluruh rentang pengoperasian ruangan sistem, arus masuk dapat mencapai 25 A
Sel koin lithium CR 2032 3,0 V
34 Memulai Dengan Sistem Anda
Page 37
Fisik
Tebal 4,24 cm (1,67 inci)
Panjang 43,4 cm (17,09 inci)
Lebar 39,37 cm (15,5 inci)
Berat (konfigurasi maksmimum) 8,058 kg (17,77 pon)
Lingkungan
CATATA N: Untuk informasi tambahan mengenai pengukuran lingkungan untuk
konfigurasi sistem spesifik, lihat dell.com/environmental_datasheets.
Suhu
Pengoperasian
10°C sampai 35°C (50°F sampai 95°F) dengan gradasi suhu maksimum 10 °C per jam
CATATA N: Untuk ketinggian di atas 2.950 kaki, suhu
pengoperasian maksimum menurun 1 ºF/550 kaki.
Penyimpanan
Kelembapan relatif
Pengoperasian
Penyimpanan
Getaran maksimum
Pengoperasian
Penyimpanan
–40° sampai 65°C (–40° hingga 149°F) dengan gradasi suhu maksimum 20°C per jam
20% sampai 80% (tanpa pengondensasian) dengan gradasi kelembapan maksimum sebesar 10% per jam
5% hingga 95% (nonkondensasi)
0,26 Grms pada frekuensi 5 Hz–350 Hz selama 15 menit
1,87 Grms pada frekuensi 10 Hz–500 Hz selama 15 menit
Memulai Dengan Sistem Anda 35
Page 38
Lingkungan (bersambung)
Guncangan maksimum
Pengoperasian
Penyimpanan
Ketinggian
Pengoperasian
Penyimpanan
Tingkat Pencemaran Udara
Kelas
Satu denyut kejutan pada sumbu z positif (satu denyut pada setiap sisi sistem) sebesar 31 G selama 2,6 mdt dalam arah pengoperasian
Enam denyut kejutan yang dilakukan berurutan pada sumbu x, y, dan z positif dan negatif (satu denyut pada setiap sisi sistem) sebesar 71 G selama paling lama 2 mdt
Enam denyut kejutan yang dilakukan berurutan pada sumbu x, y, dan z positif dan negatif (satu denyut pada setiap sisi sistem) sebesar 32 G denyut gelombang persegi yang diperhalus (faired square wave) dengan perubahan kecepatan sebesar 270 inci/detik (686 sentimeter/detik)
–16 sampai 3.048 m (–50 sampai 10.000 kaki)
CATATA N: Untuk ketinggian di atas 2.950 kaki, suhu
pengoperasian maksimum menurun 1 ºF/550 kaki.
–16 m sampai 10.600 m (–50 kaki sampai
35.000 kaki)
G1 sebagaimana didefinisikan oleh ISA-S71.04­1985
36 Memulai Dengan Sistem Anda
Page 39
Dell PowerEdge
R210 II システム

はじめに

認可モデル : E10S シリーズ
Page 40
メモ、注意、警告
メモ: コンピュータを使いやすくするための重要な情報を説明してい
ます。
注意: 手順に従わない場合は、ハードウェアの損傷やデータの損失の可能
性があることを示しています。
警告: 物的損害、けが、または死亡の原因となる可能性があることを示
しています。
___________________
本書の内容は予告なく変更されることがあります。 © 2010 すべての著作権は Dell Inc. にあります。
Dell Inc. の書面による許可のない複製は、いかなる形態においても厳重に禁じられてい ます。
本書に使用されている商標:Dell™、DELL のロゴ、および PowerEdge™ は、Dell Inc. の商標です。Intel あり、Core™ は同社の米国およびその他の国における商標です。 Microsoft
Windows Server
商標または登録商標です。Red Hat の他の国における Red Hat, Inc. の登録商標です。SUSE™ は米国およびその他の国におけ る Novell, Inc. の商標です。Citrix Citrix System, Inc. の登録商標または商標です。VMware VMware, Inc. の登録商標です。
本書では、上記記載以外の商標および会社名が使用されている場合があります。それらの 商標や会社名は、一切 Dell Inc. に帰属するものではありません。
®
は、Intel Corporation の米国およびその他の国々における登録商標で
®
は、米国および / またはその他の国における Microsoft Corporation の
®
および Red Hat Enterprise Linux® は、米国およびそ
®
および XenServer® は米国およびその他の国における
®
は米国またはその他の国におけ
®
および
認可モデル E10S シリーズ
2010 12 P/N 30G7N Rev. A00
Page 41

取り付けと設定

警告: 次の手順を実行する前に、システムに付属している安全にお使い
いただくための注意をお読みください。

システムの開梱

システムを箱から取り出し、同梱品がすべて揃っていることを確認し ます。

ラックへのレールとシステムの取り付け

注意: 密閉型ラックアセンブリ、またはマルチユニットラックアセンブリ
に設置した場合、動作時のラック周囲温度が室内の周囲温度を上回ること があります。そのため、製造元指定の最大周囲温度に適合する環境に設置 するよう注意する必要があります。 45 ページの「仕様」
詳細については、を参照してください。
レールの組み立てとラックへのシステムの取り付けの際は、システムに 付属しているマニュアルの「安全にお使いいただくために」およびラッ クへの取り付け手順に従ってください。
はじめに 39
Page 42
オプションキーボード、マウス、モニタの接続
キーボード、マウス、モニタを接続します(オプション)。 システム背面のコネクタには、どのケーブルを各コネクタに接続するか
を示すアイコンがあります。モニタのケーブルコネクタにネジがある場 合は、必ず締めてください。

電源ケーブルの接続

システムの電源ケーブルをシステムに接続し、モニタを使用する場合は モニタの電源ケーブルをモニタに接続します。
40 はじめに
Page 43

電源ケーブルの固定

システムの電源ケーブルを図のように曲げ、固定クリップで固定し ます。
電源ケーブルのもう一方の端を、アースされた電源コンセント、または UPS(無停電電源装置)や配電装置(PDU)などの電源に接続します。

システムの電源投入

システムとモニタの電源ボタンを押します。電源インジケータが点灯し ます。
はじめに 41
Page 44

ベゼルの取り付け(オプション)

ベゼルを取り付けます(オプション)。

OS のセットアップの完了

システムに OS がプリインストールされている場合は、システムに同梱 の OS のマニュアルを参照してください。OS を初めてインストールす る場合は、お使いの OS のインストールと設定に関するマニュアルを参 照してください。システムとは別途に購入したハードウェアやソフト ウェアのインストールは、OS がインストール済みであることを確認し てから行ってください。

対応 OS

Microsoft Small Business Server 2011 Standard/Essential Edition
Microsoft Windows Server 2008(x64)R2 SP1 Web/Standard/Foundation/Enterprise Edition
Microsoft Windows Server 2008 R2 (x64) Web/Standard/Foundation/Enterprise Edition
Microsoft Windows Server 2008 SP2(x86 Web/Standard/Enterprise Edition
Microsoft Windows Server 2008 SP2(x64 Web/Standard/Enterprise Edition
42 はじめに
Page 45
Microsoft Windows Server 2008 R2 SP1(x64) Hyper-V Standard/Enterprise Edition
Microsoft Windows Server 2008 R2 (x64) Hyper-V Standard/Enterprise Edition
Microsoft Windows Server 2008 SP2 (x64) Hyper-V Standard/Enterprise Edition
VMware ESX 4.1 Update 1 (Classic)
VMware ESX 4.1 Update 1 (Embedded)
Citrix XenServer 5.6 Feature Pack 1
Red Hat Enterprise Linux 6.0 (x86_64)
SUSE Linux Enterprise Server 11 SP1(x86_64
メモ: 対応 OS の最新情報については、support.dell.com を参照してくだ
さい。

Dell ソフトウェア製品ライセンス契約

システムを使用する前に、システムに付属の ライセンス契約をお読みください。
Dell
によりインストールされているソフトウェアのCD、 ディスケットは、システムのハードディスクドライブにインストー ルされているソフトウェアのバップアップコピーです。
使用許諾契約に同意しない場合は、カスタマーケアまでご連絡くだ さい。米国にお住まいの方は、 までお電話ください。米国外にお住まいの方は、 にアクセスしてページの上部からお住いの国または地域を選んでく ださい。
800-WWW-DELL(800-999-3355
Dell
ソフトウェア製品
DVD
support.dell.com
または
はじめに 43
Page 46

その他の情報

警告: システムに付属のマニュアルで安全および認可に関する情報を参
照してください。保証に関する情報は、このマニュアルに含まれている場 合と、別の文書として付属している場合があります。 
ラックソリューションに付属のマニュアルでは、システムをラック に取り付ける方法について説明しています。
『オーナーズマニュアル』では、システムの機能、システムのトラブ
ルシューティング方法、およびシステムコンポーネントの取り付け や交換の方法について説明しています。この文書は
support.dell.com/manuals からオンラインで入手できます。
OS
、システム管理ソフトウェア、システムアップデート、およびシ ステムと同時に購入したシステムコンポーネントに関するものを 含め、システムの設定や管理のためのマニュアルやツールが収録さ れた、システムに付属のメディア。
メモ: アップデートには他の文書の内容を差し替える情報が含まれ
ている場合があるため、support.dell.com/manuals でアップデートがな いかどうかを常に確認し、初めにお読みください。

テクニカルサポートの利用法

本書の手順が理解できない場合やシステムが思ったとおりに動作しない 場合は、『オーナーズマニュアル』を参照してください。 デルでは広範 囲にわたるハードウェアのトレーニングと資格認証 を実施しています。 詳細については、dell.com/training を参照してください。このサー ビスが提供されていない地域もあります。
44 はじめに
Page 47
仕様
プロセッサ
プロセッサのタイプ Intel Core プロセッサ i3-2100 製品ファミリ
1
または
Intel Core プロセッサ iE3-1200 製品ファミリ 1
または
( 利用可能な場合 ) Intel Pentium プロセッサ 1
拡張バス
バスのタイプ
拡張スロット フルハイト、ハーフレングス x16 リンク 1
メモリ
アーキテクチャ 1066 MHz および 1333 MHz DDR3 バッファ
メモリモジュールソケット 240 ピンソケット 4
メモリモジュールの容量 1 GB2 GB4 GB、または 8 GB
最小 RAM
最大 RAM
PCI Express Generation 2
なし誤り訂正符号(ECC DIMM
1 GB
32 GB
ドライブ
ハードドライブ ケーブル接続の 3.5 インチ SAS 、または内蔵
SATA ドライブ 2 台まで または ケーブル接続の 2.5 インチ SAS 、または内蔵 の SATA ドライブ 2 台まで
オプティカルドライブ オプションの内蔵 SATA DVD-ROM または
DVD+/-RW ドライブ 1
メモ: DVD デバイスはデータ専用。
オプションの外付け USB DVD-ROM
はじめに 45
Page 48
コネクタ
背面
NIC
シリアル
USB
ビデオ
eSATA
前面
ビデオ
USB
内蔵
USB
ビデオ
ビデオのタイプ Matrox G200Winbond WPCM450 に内蔵)
ビデオメモリ
Power(電源)
AC 電源装置(各電源装置につき)
ワット数
電圧
熱出力
最大流入電流
バッテリ
システムバッテリ
RJ-45(内蔵 1 GB NIC 用)2
16550 互換 9 ピン DTE
4 ピン USB 2.0 対応コネクタ 2
15 ピン VGA
7 ピンコネクタ 1
15 ピン VGA
4 ピン USB 2.0 対応コネクタ 2
4 ピン USB 2.0 対応コネクタ 2
8 MB
250 W
100 VAC-240 VAC50 Hz/60 Hz4.0 A-2.0 A
最大 1040 BTU/
通常のラインコンディションのもと、システ ムの動作環境全範囲で、入電量が 25 A に達す ることがあります。
3.0 V コイン型リチウムバッテリー CR 2032
46 はじめに
Page 49
サイズと重量
高さ
奥行き
重量(最大構成)
環境
4.24 cm
43.4 cm
39.37 cm
8.058 kg
メモ: 特定のシステム構成におけるその他の環境条件の詳細については、
dell.com/environmental_datasheets を参照してください。
温度
動作時
1 時間当たり最大 10°C の温度変化で 10 35°C
メモ: 高度が 900 m を超えると、動作時の許
容最大温度は 300 m ごとに 1°C ずつ低下しま す。
保管時
相対湿度
動作時
ストレージ
最大振動
動作時
保管時
1 時間当たり最大 20°C の温度変化で
-40 65°C
1 時間当たり最大 10 パーセントの湿度変化で 20 80 パーセント(結露しないこと)
5 95 パーセント(結露しないこと)
15 分間にわたり 5 350 Hz 0.26 Grms
15 分間にわたり 10 500 Hz 1.87 Grms
はじめに 47
Page 50
環境 (続き)
最大衝撃
動作時
保管時
高度
動作時
保管時
空気汚染物質レベル
クラス
z 軸の正方向に 1 衝撃パルス(システムの各面 に対して 1 パルス)、 2.6 ミリ秒に 31 G
xyz 軸の正および負方向に 6 連続衝撃パル ス(システムの各面に対して 1 パルス)、 2 ミ リ秒以下に 71 G
xyz 軸の正および負方向に 6 連続衝撃パル ス(システムの各面に対して 1 パルス)、32 G フェアードスクエアパルス波(686 cm / 秒の 速度変化)
- 16 3,048 m
メモ: 高度が 900 m を超えると、動作時の許
容最大温度は 300 m ごとに 1°C ずつ低下し ます。
- 16 10,600 m
G1 ISA-S71.04-1985 の定義による)
48 はじめに
Page 51
Dell PowerEdge
R210 II 시스템

시스템 시작 안내서

규정 모델 : E10S 시리즈
Page 52
주 , 주의 및 경고
주: "주"는 컴퓨터를 보다 효율적으로 사용하는 데 도움을 주는 중요 정보를 알
려줍니다.
주의: "주의"는 지침을 준수하지 않을 경우의 하드웨어 손상이나 데이터 손실
위험을 설명합니다.
경고 : " 경고 " 는 재산상의 피해나 심각한 부상 또는 사망을 유발할 수 있는
위험이 있음을 알려줍니다 .
___________________
발행물에 수록된 정보는 사전 통보 없이 변경될 있습니다. © 2010 Dell Inc. 저작권 본사 소유.
Dell Inc.의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히 금지 됩니다.
본 설명서에 사용된 상표 Dell™, DELL 로고 및 PowerEdge™는 Dell Inc.의 상표입니다. 미국 및 기타 국가에서 Intel 및 Windows Server 표입니다. Red Hat 의 등록 상표입니다. SUSE™는 미국 및 기타 국가에서 Novell, Inc.의 상표입니다. Citrix
XenServer VMware
본 발행물에서 특정 회사의 상표 및 회사 이름 또는 제품을 지칭하기 위해 기타 상표 및 상호 를 사용할 수도 있습니다. Dell Inc.는 자사가 소유하고 있는 것 이외에 기타 모든 상표 및 상호 에 대한 어떠한 소유권도 없습니다.
®
는 미국 및/또는 기타 국가에서 Citrix Systems, Inc.의 등록 상표 또는 상표입니다.
®
는 미국 또는 기타 국가에서 VMWare, Inc.의 등록 상표 또는 상표입니다.
®
Intel Corporation 등록 상표이고 Core™ 상표입니다. Microsoft®
®
는 미국 및/또는 기타 국가에서 Microsoft Corporation의 상표 또는 등록 상
®
Red Hat Enterprise Linux®는 미국 및/또는 기타 국가에서 Red Hat, Inc.
®
규정 모델 E10S 시리즈
2010 12 P/N 30G7N Rev. A00
Page 53

설치 및 구성

경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토
하십시오 .

시스템 포장 풀기

시스템 포장을 풀고 각 항목을 확인합니다

랙에 레일 및 시스템 설치

주의 : 폐쇄형 또는 멀티 유닛 랙 조립품에 설치할 경우 , 랙 환경의 작동 시 주
위 온도가 주위 실온보다 높을 수 있습니다 . 그러므로 , 해당 장비는 제조업체 가 지정한 주변 최대 온도 (Tma) 와 호환되는 환경에 설치되어야 합니다 .
내용은
57 페이지의 " 기술 사양 " 참조하십시오 .
.
자세
시스템과 함께 제공되는 안전 지침 및 랙 설치 지침에 따라 레일을 조립하고 시스템을 랙에 설치합니다
.
시스템 시작 안내서 51
Page 54
선택사양 — 키보드 , 마우스 및 모니터 연결
키보드, 마우스 및 모니터(선택 사양)를 연결합니다 시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된 아이
있습니다. 모니터의 케이블 커넥터에 있는 나사(해당하는 경우)를 단단
콘이 히
고정하십시오
.
.

전원 케이블 연결

시스템의 전원 케이블을 시스템에 연결하고, 모니터를 사용하는 경우 모니 터의
전원 케이블을 모니터에 연결합니다
.
52 시스템 시작 안내서
Page 55

전원 케이블 고정

그림과 같이 시스템 전원 케이블을 구부려서 고정 클립으로 케이블을 고정 합니다
.
전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나, 무정전 전원 공급 장치
(UPS)
또는 배전 장치
(PDU)와
같은 별도의 전원에 연결합니다
.

시스템 켜기

시스템 및 모니터의 전원 단추를 누릅니다. 전원 표시등이 켜집니다
시스템 시작 안내서 53
.
Page 56

베젤 ( 선택 사양 ) 설치

베젤(선택 사양)을 설치합니다
.

운영 체제 설치 완료

시스템 구입 시 운영 체제가 미리 설치되어 있는 경우 시스템과 함께 제공되
운영
는 제 웨어 하십시오
체제 설명서를 참조하십시오. 운영 체제를 처음 설치하려면 운영 체
설치 및 구성
또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어 있는지 확인
설명서를 참조하십시오. 시스템과 함께 구입하지 않은 하드
.

지원되는 운영 체제

Microsoft Small Business Server 2011 Standard 및 Essential Edition
Microsoft Windows Server 2008 R2 SP1(x64) Web, Standard, Foundation
Enterprise Edition
Microsoft Windows
Enterprise Edition
Microsoft Windows Server 2008 SP2(x86) Web, Standard
Enterprise Edition
Microsoft Windows Server 2008 SP2(x64) Web, Standard
Enterprise Edition
•Hyper-V Enterprise Edition
포함
Server 2008 R2(x64) Web, Standard, Foundation
Microsoft Windows Server 2008 R2 SP1(x64) Standard및
54 시스템 시작 안내서
Page 57
•Hyper-V 포함 Microsoft Windows Server 2008 R2(x64) Standard및 Enterprise Edition
•Hyper-V Enterprise Edition
VMware ESX 4.1 Update 1(Classic)
VMware ESX 4.1 Update 1(Embedded)
Citrix XenServer 5.6 Feature Pack 1
Red Hat Enterprise Linux
SUSE Linux Enterprise Server 11 SP1(x86_64)
주: 지원되는 운영 체제에 대한 최신 정보는 support.dell.com 참조하십시오.
포함
Microsoft Windows Server 2008 SP2(x64) Standard및
6.0(x86_64)

Dell 소프트웨어 라이센스 계약서

시스템을 사용하기 전에 시스템과 함께 제공된 계약서를 읽어보십시오
Dell
에서 설치한 모든 소프트웨어의 하드 디스크 드라이브에 설치된 소프트웨어의 백업 복사본으로 간주해야 합니다
.
계약서 내용에 동의하지 않으면 고객 지원 전화 번호로 연락하십시오. 미
거주하는 고객은
국에 미국 이외의 지역에 거주하는 고객은 support.dell.com을
위에서 해당 국가 또는 지역을 선택하십시오
.
CD, DVD 또는
800-WWW-DELL(800-999-3355)로
Dell
소프트웨어 라이센스
디스켓은 시스템의
전화하십시오
방문하고 페이
.
.
시스템 시작 안내서 55
Page 58

기타 필요한 정보

경고 : 시스템과 함께 제공되는 안전 및 규제 정보를 참조하십시오 . 보증 정
보는 이 문서에 포함되거나 별도의 문서로 제공될 수 있습니다 .
랙 솔루션과 함께 제공되는 랙 설명서에는 시스템을 랙에 설치하는 방법
기술되어 있습니다
소유자 설명서에서는 시스템 기능에 대한 정보를 제공하고 시스템 문제
해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명합니다. 이 문
support.dell.com/manuals에서
서는 운영 체제, 시스템 관리 소프트웨어, 시스템 업데이트 및 시스템과 함께
구입한 시스템 구성요소와 관련된 설명서 및 도구를 비롯하여 시스템을 구성 및 관리하는 데 필요한 설명서 및 도구를 제공하는 모든 매체가 시스
함께
템과
제공됩니다
주: 새로운 업데이트가 없는지 support.dell.com/manuals에서 항상 확인하
십시오. 업데이트에는 최신 정보가 수록되어 있으므로 다른 문서를 읽기 전에 반드시 먼저 참조하시기 바랍니다.
.
온라인으로 볼 수 있습니다
.
.

기술 지원 얻기

본 안내서의 절차가 이해되지 않거나 시스템이 제대로 작동하지 않을 경우 에는
소유자 설명서 참조하십시오
증을
제공합니다. 자세한 내용은 dell.com/training을
따라 이 서비스가 제공되지 않을 수도 있습니다
. Dell은
포괄적인 하드웨어 교육 및 인
참조하십시오. 지역에
.
56 시스템 시작 안내서
Page 59

기술 사양

프로세서
프로세서 유형
확장 버스
버스 종류
확장 슬롯 전체 높이, 절반 길이
메모리
아키텍처
Intel Core
또는
Intel Xeon
또는
Intel Pentium
PCI Express Generation 2
1066MHz 및 1333MHz DDR3 Unbuffered ECC(Error Correcting Code) DIMM
프로세서
프로세서
프로세서 1개(사용 가능한 경우
(i3-2100
(E3-1200
x16 링크 1
제품군
제품군
) 1
) 1
)
메모리 모듈 소켓
모듈
드라이브
용량
메모리
최소
RAM
최대
RAM
드라이브
하드 드라이브
광학
240핀 4
1GB, 2GB, 4GB 또는 8GB
1GB
32GB
3.5인치
이브 또는
2.5인치
이브
내장형 이브
케이블 방식
최대 2
케이블 방식
최대 2
SATA DVD-ROM 또는 DVD+/-RW
1개(옵션)
SAS 또는 SATA
SAS 또는 SATA
주: DVD 장치는 데이터 전용입니다.
외부
USB DVD-ROM(선택 사양)
시스템 시작 안내서 57
내장형 드라
내장형 드라
드라
Page 60
커넥터
후면
NIC
직렬
USB
비디오
eSATA
전면
비디오
USB
내부
USB
비디오
비디오 종류
비디오 메모리
Power( 전원 )
AC 전원 공급 장치(전원 공급
와트
전압
열 손실 최대
최대 유입 전류 일반적인 회선 상태 및 전체 시스템 작동 범위에
배터리
시스템 배터리
장치당
내장형
RJ-45(
9핀, DTE, 16550
핀 2개
4
15핀 VGA
핀 커넥터 1개
7
15핀 VGA
4
핀 2개
핀 2개
4
Winbond WPCM450에
8MB
)
250W
100VAC–240VAC, 50Hz/60Hz, 4.0A–2.0A
1040BTU/hr
최대 25A의
CR 2032 3.0V 리튬 코인
1GB NIC용) 2
호환
, USB 2.0
, USB 2.0
, USB 2.0
호환
호환
호환
전류가 유입될 수 있습니다
내장된
Matrox G200
.
58 시스템 시작 안내서
Page 61
실제
높이
너비
깊이
무게(최대 구성 시
환경
)
4.24cm(1.67인치)
43.4cm(17.09인치)
39.37cm(15.5인치)
8.058kg(17.77lb)
주: 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은
dell.com/environmental_datasheets를 참조하십시오.
온도
작동
10°C ~ 35°C(50°F ~ 95°F),
°C의 온도 변화 기준
10
주: 2,950피트 이상의 고도에서 최대 작동 온도
는 1°F/550ft로 감소됩니다.
보관
상대 습도
작동
보관
최대 진동
작동
보관
–40°C ~ 65°C(–40°F ~ 149°F),
°C의 온도 변화 기준
20
20% ~ 80%(
기준
5 ~ 95%(
5Hz–350Hz에서 15분 동안 0.26Grms
10Hz–500Hz에서 15분 동안 1.87Grms
비응축
비응축
),
시간당 최고
)
시간당 최고
시간당 최고
10%의 습도
시스템 시작 안내서 59
Page 62
환경 ( 계속 )
최대 충격
작동 작동 방향으로
펄스 1회(
보관 최대
고도
작동
2ms 동안 (+/-) x, y, z
펄스 6회(시스템 각 면에 1회의 펄스
속도 변화가
(+/-) x, y, z
의 각 면에 1회의 펄스
–16m ~ 3,048m(–50ft ~ 10,000ft)
주: 2,950피트 이상의 고도에서 최대 작동 온도
는 1°F/550ft로 감소됩니다.
보관
공기 중 오염 물질 수준
등급
–16m ~ 10,600m(–50ft ~ 35,000ft)
ISA-S71.04-1985의
2.6ms 동안 (+) z
시스템 각 면에 1회의 펄스
686cm/초(270인치/초)인 32G
축으로 연속 충격 펄스 6회(시스템
)
규정에 따른
축으로
축으로
G1
31G의
)
71G의 연속 충격
)
구형파
60 시스템 시작 안내서
Loading...