Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc.
®
is a registered trademark and Core™ is a trademark of Intel Corporation in the U.S. and
Intel
other countries. Microsoft
of Microsoft Corporation in the United States and/or other countries. Red Hat
®
Linux
and are registered trademarks of Red Hat, Inc. in the United States and/or other countries.
SUSE ™ is a trademark of Novell, Inc. in the United States and other countries. Citrix
XenServer
and/or other countries. VMware
United States or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
®
are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States
®
and Windows Server® are either trademarks or registered trademarks
®
is a registered trademarks or trademark of VMWare, Inc. in the
®
and Red Hat Enterprise
®
and
Regulatory Model E10S Series
December 2010 P/N 30G7NRev. A00
Page 5
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item.
Installing the Rails and System in a Rack
CAUTION: If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by
the manufacturer.
For more information, see
"Technical Specifications" on page 9.
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
Getting Started With Your System3
Page 6
Optional—Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable
to plug into each connector. Be sure to tighten the screws (if any) on the
monitor's cable connector.
Connecting the Power Cable
Connect the system’s power cable to the system and, if a monitor is used,
connect the monitor’s power cable to the monitor.
4Getting Started With Your System
Page 7
Securing the Power Cable
Bend the system power cable as shown in the illustration and secure the cable
in the retention clip.
Plug the other end of the power cable into a grounded electrical outlet or
a separate power source such as an uninterrupted power supply (UPS) or
a power distribution unit (PDU).
Turning On the System
Press the power button on the system and the monitor. The power indicators
should light.
Getting Started With Your System5
Page 8
Installing the Optional Bezel
Install the bezel (optional).
Complete the Operating System Setup
If you purchased a preinstalled operating system, see the operating system
documentation that ships with your system. To install an operating system for
the first time, see the installation and configuration documentation for your
operating system. Be sure the operating system is installed before installing
hardware or software not purchased with the system.
Supported Operating Systems
•Microsoft Small Business Server 2011 Standard and Essential Editions
•Microsoft Windows Server 2008 R2 SP1 (x64) Web, Standard,
Foundation, and Enterprise Editions
•Microsoft Windows
and Enterprise Editions
•Microsoft Windows Server 2008 SP2 (x86) Web, Standard,
and Enterprise Editions
•Microsoft Windows Server 2008 SP2 (x64) Web, Standard,
and Enterprise Editions
•Microsoft Windows Server 2008 R2 SP1(x64) with Hyper-V for
Standard and Enterprise Editions
6Getting Started With Your System
Server 2008 R2 (x64) Web, Standard, Foundation,
Page 9
•Microsoft Windows Server 2008 R2 (x64) with Hyper-V for Standard and
Enterprise Editions
•Microsoft Windows Server 2008 SP2 (x64) with Hyper-V for Standard and
Enterprise Editions
•VMware ESX 4.1 Update 1 (Classic)
•VMware ESX 4.1 Update 1 (Embedded)
•Citrix XenServer 5.6 Feature Pack 1
•Red Hat Enterprise Linux
•SUSE Linux Enterprise Server 11 SP1 (x86_64)
NOTE: For the latest information on supported operating systems,
see support.dell.com.
6.0 (x86_64)
Dell Software License Agreement
•Before using your system, please read the Dell Software License
Agreement that came with your system.
•You must consider any CD, DVD, or diskette set of Dell installed
software as BACKUP copies of the software installed on your system's
hard-disk drive.
•If you do not accept the terms of the agreement, please call the customer
assistance telephone number. For customers in the United States,
call 800-WWW-DELL (800-999-3355). For customers outside the
United States, visit
from the top of the page.
support.dell.com
and select your country or region
Getting Started With Your System7
Page 10
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document
or as a separate document.
•The rack documentation included with your rack solution describes how
to install your system into a rack.
•The
•Any media that ships with your system that provides documentation and
Owner’s Manual
and describes how to troubleshoot the system and install or replace
system components. This document is available online at
support.dell.com/manuals
tools for configuring and managing your system, including those pertaining
to the operating system, system management software, system updates,
and system components that you purchased with your system.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
provides information about system features
.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does
not perform as expected, see your Owner’s Manual. Dell offers
comprehensive hardware training and certification. See dell.com/training
for more information. This service may not be offered in all locations.
8Getting Started With Your System
Page 11
Información de la NOM (sólo para México)
La información que se proporciona a continuación aparece en el dispositivo
descrito en este documento, en cumplimiento de los requisitos de la Norma
Oficial Mexicana (NOM):
Importador:
Número de modelo:E10S
Voltaje de alimentación:100 V CA-240 V CA
Frecuencia:50 – 60 Hz
Consumo eléctrico:4,0 - 2,0 A
Technical Specifications
Processor
Processor typeOne Intel Core processor i3-2100 product family
or
One Intel Xeon processor E3-1200 product family
or
One Intel Pentium processor (when available)
Expansion Bus
Bus typePCI Express Generation 2
Expansion slotsOne full-height, half-length x16 link
Memory
Architecture1066 MHz and 1333 MHz DDR3 unbuffered
Error Correcting Code (ECC) DIMMs
Memory module socketsFour 240-pin
Memory module capacities1 GB, 2 GB, 4 GB, or 8 GB
Minimum RAM1 GB
Maximum RAM32 GB
Getting Started With Your System9
Page 12
Drives
Hard drivesUp to two 3.5-inch cabled SAS or SATA
internal drives
or
Up to two 2.5-inch cabled SAS or SATA
internal drives
Optical drive One optional internal SATA DVD-ROM or
DVD+/-RW drive
NOTE: DVD devices are data only.
Optional external USB DVD-ROM
Connectors
Back
NIC
Serial
USB
Video
eSATA
Front
Video
USB
Internal
USB
Two RJ-45 (for integrated 1 GB NICs)
9-pin, DTE, 16550-compatible
Two 4-pin, USB 2.0-compliant
15-pin VGA
One 7-pin connector
15-pin VGA
Two 4-pin, USB 2.0-compliant
Two 4-pin, USB 2.0-compliant
Video
Video typeMatrox G200, integrated in Winbond WPCM450
Video memory8 MB
10Getting Started With Your System
Page 13
Power
AC power supply (per power supply)
Wattage
Vo lt ag e
Heat dissipation
Maximum inrush current
Batteries
System battery
Physical
Height4.24 cm (1.67 inches)
Width43.4 cm (17.09 inches)
Depth39.37 cm (15.5 inches)
Weight
(maximum configuration)
Environmental
250 W
100 VAC–240 VAC, 50 Hz/60 Hz, 4.0 A–2.0 A
1040 BTU/hr maximum
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 25 A
CR 2032 3.0-V lithium coin cell
8.058 kg (17.77 lb)
NOTE: For additional information about environmental measurements for specific
system configurations, see dell.com/environmental_datasheets.
Temperature
Operating
10 °C to 35 °C (50 °F to 95 °F) with a maximum
temperature gradation of 10 °C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1 ºF/550 ft.
Storage
Relative humidity
Operating
Storage
–40 °C to 65 °C (–40 °F to 149°F) with a
maximum temperature gradation of 20 °C
per hour
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
Getting Started With Your System11
Page 14
Environmental (continued)
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
0.26 Grms at 5 Hz–350 Hz for 15 min
1.87 Grms at 10 Hz–500 Hz for 15 min
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms in
the operational orientation
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of 71 G for
up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 32 G faired
square wave pulse with velocity change at
270 inches/second (686 centimeters/second)
Dilarang keras mereproduksi materi ini dalam cara apapun tanpa izin tertulis dari Dell Inc.
Merek dagang yang digunakan dalam teks ini: Dell™, logo DELL, dan PowerEdge™, adalah merek
dagang dari Dell Inc. Intel
Corporation di AS. dan negara-negara lain. Microsoft
dagang atau merek dagang terdaftar dari Microsoft Corporation di Amerika Serikat dan/atau negaranegara lain. Red Hat
di Amerika Serikat dan/atau negara-negara lain. SUSE™ adalah merek dagang terdaftar dari
Novell, Inc. di Amerika Serikat dan negara-negara lain. Citrix
terdaftar atau merek dagang dari Citrix Systems, Inc. di Amerika Serikat dan/atau negara-negara lain.
®
VMware
negara lain.
Merek dagang dan nama dagang lain mungkin digunakan dalam publikasi ini untuk merujuk ke pihak
lain yang memiliki merek dan nama terkait atau produk mereka. Dell Inc. menafikan kepentingan
kepemilikan apa pun atas merek dagang dan nama dagang selain miliknya sendiri.
adalah merek dagang terdaftar dari VMware, Inc. di Amerika Serikat dan/atau negara-
®
adalah merek dagang terdaftar dan Core™ adalah merek dagang dari Intel
®
dan Red Hat Enterprise Linux® adalah merek dagang terdaftar dari Red Hat, Inc.
®
dan Windows Server® merupakan merek
®
dan XenServer® adalah merek dagang
Model Resmi Seri E10S
Desember 2010 No. Komp. 30G7NRev. A00
Page 29
Instalasi dan Konfigurasi
PERINGATAN: Sebelum melakukan prosedur berikut, bacalah petunjuk
keselamatan yang disertakan dengan sistem.
Membuka Kemasan Sistem
Buka kemasan sistem Anda dan kenali setiap komponen.
Memasang Rel dan Sistem dalam Rak
PERHATIAN: Jika dipasang pada rakitan rak multi-unit atau rak tertutup, suhu
pengoperasian sekitar rak dapat menjadi lebih tinggi daripada suhu ruangan.
Oleh karena itu, Anda disarankan untuk memasang peralatan di lingkungan yang
sesuai dengan suhu sekitar maksimal (Tma) yang ditentukan oleh produsen.
informasi lebih lanjut, lihat
"Spesifikasi Teknis" di halaman 33.
Untuk
Rakit rel dan pasang sistem dalam rak sesuai dengan petunjuk keselamatan
dan petunjuk pemasangan rak yang disertakan bersama sistem Anda.
Memulai Dengan Sistem Anda27
Page 30
Opsional—Menghubungkan Keyboard, Mouse, dan Monitor
Hubungkan keyboard, mouse, dan monitor (opsional).
Konektor di bagian belakang sistem Anda memiliki ikon yang menunjukkan
kabel mana yang harus disambungkan ke setiap konektor. Pastikan baut
(jika ada) dikencangkan pada konektor kabel monitor.
Menghubungkan Kabel Daya
Hubungkan kabel daya sistem ke sistem dan, jika monitor digunakan,
hubungkan kabel daya monitor ke monitor.
28Memulai Dengan Sistem Anda
Page 31
Mengamankan Kabel Daya
Bengkokkan kabel daya sistem seperti tampak pada gambar dan tahan kabel
dengan klip penahan.
Sambungkan ujung lain kabel daya ke stopkontak listrik yang telah terhubung
ke ground atau ke sumber daya yang terpisah seperti catu daya tak terputus
(UPS) atau unit distribusi daya (PDU)
Menyalakan Sistem
Tekan tombol daya pada sistem dan monitor. Indikator daya harus menyala.
Memulai Dengan Sistem Anda29
Page 32
Memasang Bingkai Opsional
Pasang bingkai (opsional).
Menyelesaikan Pemasangan Sistem Operasi
Jika Anda membeli sistem operasi yang telah diinstal sebelumnya, lihat
dokumentasi sistem operasi yang dikirimkan bersama sistem Anda. Untuk
menginstal sistem operasi untuk pertama kalinya, lihat dokumentasi instalasi
dan konfigurasi untuk sistem operasi Anda. Pastikan bahwa sistem operasi
telah diinstal sebelum Anda menginstal perangkat keras atau perangkat lunak
yang tidak dibeli bersama sistem.
Sistem Operasi Yang Didukung
•Microsoft Small Business Server 2011 Edisi Standard dan Essential
•Microsoft Windows Server 2008 R2 SP1 (x64) Web, Edisi Standard,
Foundation, dan Enterprise
•Microsoft Windows
Foundation, dan Enterprise
•Microsoft Windows Server 2008 SP2 (x86) Web, Edisi Standard,
dan Enterprise
•Microsoft Windows Server 2008 SP2 (x64) Web, Edisi Standard,
dan Enterprise
30Memulai Dengan Sistem Anda
Server 2008 R2 (x64) Web, Edisi Standard,
Page 33
•Microsoft Windows Server 2008 R2 SP1(x64) dengan Hyper-V untuk Edisi
Standard dan Enterprise Editions
•Microsoft Windows Server 2008 R2 (x64) dengan Hyper-V untuk Edisi
Standard and Enterprise
•Microsoft Windows Server 2008 SP2 (x64) dengan Hyper-V untuk Edisi
Standard dan Enterprise
•VMware ESX 4.1 Update 1 (Classic)
•VMware ESX 4.1 Update 1 (Embedded)
•Citrix XenServer 5.6 Feature Pack 1
•Red Hat Enterprise Linux
•SUSE Linux Enterprise Server 11 SP1 (x86_64)
NOTE: Untuk informasi terbaru mengenai sistem operasi yang didukung,
kunjungi support.dell.com.
6.0 (x86_64)
Perjanjian Lisensi Perangkat lunak Dell
•Sebelum menggunakan sistem Anda, silakan baca Perjanjian Lisensi
Perangkat Lunak Dell yang disertakan bersama sistem Anda.
•Anda harus menganggap CD, DVD, atau disket apapun dari perangkat
lunak Dell yang telah diinstal sebagai salinan CADANGAN dari perangkat
lunak yang diinstal pada hardi-disk drive sistem Anda.
•Jika Anda tidak menerima syarat perjanjian ini, silakan hubungi nomor
telepon bantuan pelanggan. Untuk pelanggan di Amerika Serikat, hubungi
800-WWW-DELL (800-999-3355). Untuk pelanggan di luar
Amerika Serikat, silakan kunjungi
wilayah Anda dari bagian atas halaman.
support.dell.com
dan pilih negara atau
Memulai Dengan Sistem Anda31
Page 34
Informasi Lain Yang Mungkin Anda Perlukan
PERINGATAN: Lihat informasi keselamatan dan peraturan yang dikirimkan
bersama dengan sistem Anda. Informasi jaminan mungkin disertakan di dalam
dokumen ini atau sebagai suatu dokumen terpisah.
•Dokumentasi rak yang tercakup dalam solusi rak Anda menjelaskan
bagaimana cara memasang sistem ke dalam rak.
Panduan Pemilik Komputer
•
sistem dan menjelaskan cara memecahkan kesalahan sistem dan
memasang atau mengganti komponen sistem. Dokumen ini tersedia
secara online di
•Media apa pun yang dikirimkan bersama dengan sistem Anda yang
memberi dokumentasi dan alat untuk mengonfigurasikan dan mengelola
sistem Anda termasuk yang berhubungan dengan sistem operasi, perangkat
lunak manajemen sistem, pembaruan sistem, dan komponen sistem yang
Anda beli bersama sistem Anda.
NOTE: Selalu periksa ketersediaan pembaruan di situs
support.dell.com/manuals dan baca pembaruan tersebut terlebih dahulu
karena biasanya pembaruan tersebut sering kali menggantikan informasi
dalam dokumen.
support.dell.com/manuals
menyediakan informasi mengenai fitur-fitur
.
Mendapatkan Bantuan Teknis
Jika Anda tidak memahami prosedur dalam panduan ini atau jika sistem
tidak beroperasi seperti yang diharapkan lihat Panduan Pemilik Komputer yang
Anda terima. Dell menyediakan pelatihan dan sertifikasi perangkat keras
secara menyeluruh. Lihat dell.com/training untuk informasi lebih lanjut.
Layanan ini mungkin tidak tersedia di semua lokasi.
32Memulai Dengan Sistem Anda
Page 35
Spesifikasi Teknis
Prosesor
Tipe prosesorSebuah produk prosesor keluarga Intel Core
i3-2100
atau
Sebuah produk prosesor keluarga Intel Xeon
E3-1200
atau
Sebuah prosesor Intel Pentium (jika ada)
Bus Ekspansi
Tipe busPCI Express Generasi 2
Slot ekspansiSatu slot dengan ketinggian penuh, setengah
panjang, link x16
Memori
ArsitekturDIMM DDR3 1066-MHz atau 1333-MHz dengan
Kode Mengoreksi Kesalahan (ECC) tanpa buffer.
Soket modul memoriEmpat 240-pin
Kapasitas modul memori1 GB, 2 GB, 4 GB, atau 8 GB
RAM minimum1 GB
RAM maksimum32 GB
Drive
Hard driveSampai dua drive internal berukuran 3.5-inch
menggunakan kabel SAS atau SATA
atau
Sampai dua drive internal berukuran 2.5-inch
berkabel SAS atau SATA
Drive optis Sebuah drive DVD-ROM atau DVD+/-RW SATA
internal opsional
CATATA N: Perangkat DVD hanya data.
USB DVD-ROM eksternal opsional
Memulai Dengan Sistem Anda33
Page 36
Konektor
Belakang
NIC
Serial
USB
Video
eSATA
Depan
Video
USB
Internal
USB
Video
Tipe videoMatrox G200, terpadu pada Winbond WPCM450
Memori video8 MB
Daya
Catu daya AC (per catu daya)
Watt D a ya
Te ga n ga n
Pelepasan panas
Lonjakan arus maksimum
Baterai
Baterai sistem
Dua RJ-45 (untuk NIC terpadu 1GB)
9 pin, DTE, kompatibel dengan 16550
Dua konektor 4 pin untuk USB 2.0
VGA 15 pin
Sebuah konektor 7-pin
VGA 15 pin
Dua konektor 4 pin untuk USB 2.0
Dua konektor 4 pin untuk USB 2.0
250 W
100 VAC–240 VAC, 50 Hz/60 Hz, 4,0 A–2,0 A
1040 BTU/jam maksimum
Di bawah kondisi listrik yang biasanya ada dan di
dalam seluruh rentang pengoperasian ruangan
sistem, arus masuk dapat mencapai 25 A
Sel koin lithium CR 2032 3,0 V
34Memulai Dengan Sistem Anda
Page 37
Fisik
Tebal4,24 cm (1,67 inci)
Panjang43,4 cm (17,09 inci)
Lebar39,37 cm (15,5 inci)
Berat (konfigurasi maksmimum) 8,058 kg (17,77 pon)
Lingkungan
CATATA N: Untuk informasi tambahan mengenai pengukuran lingkungan untuk
konfigurasi sistem spesifik, lihat dell.com/environmental_datasheets.
Suhu
Pengoperasian
10°C sampai 35°C (50°F sampai 95°F) dengan
gradasi suhu maksimum 10 °C per jam
CATATA N: Untuk ketinggian di atas 2.950 kaki, suhu
pengoperasian maksimum menurun 1 ºF/550 kaki.
Penyimpanan
Kelembapan relatif
Pengoperasian
Penyimpanan
Getaran maksimum
Pengoperasian
Penyimpanan
–40° sampai 65°C (–40° hingga 149°F) dengan
gradasi suhu maksimum 20°C per jam
20% sampai 80% (tanpa pengondensasian) dengan
gradasi kelembapan maksimum sebesar 10%
per jam
5% hingga 95% (nonkondensasi)
0,26 Grms pada frekuensi 5 Hz–350 Hz selama
15 menit
1,87 Grms pada frekuensi 10 Hz–500 Hz selama
15 menit
Memulai Dengan Sistem Anda35
Page 38
Lingkungan (bersambung)
Guncangan maksimum
Pengoperasian
Penyimpanan
Ketinggian
Pengoperasian
Penyimpanan
Tingkat Pencemaran Udara
Kelas
Satu denyut kejutan pada sumbu z positif (satu
denyut pada setiap sisi sistem) sebesar 31 G
selama 2,6 mdt dalam arah pengoperasian
Enam denyut kejutan yang dilakukan berurutan
pada sumbu x, y, dan z positif dan negatif (satu
denyut pada setiap sisi sistem) sebesar 71 G
selama paling lama 2 mdt
Enam denyut kejutan yang dilakukan berurutan
pada sumbu x, y, dan z positif dan negatif (satu
denyut pada setiap sisi sistem) sebesar 32 G
denyut gelombang persegi yang diperhalus (faired
square wave) dengan perubahan kecepatan
sebesar 270 inci/detik (686 sentimeter/detik)
–16 sampai 3.048 m (–50 sampai 10.000 kaki)
CATATA N: Untuk ketinggian di atas 2.950 kaki, suhu
本書に使用されている商標:Dell™、DELL のロゴ、および PowerEdge™ は、Dell Inc.
の商標です。Intel
あり、Core™ は同社の米国およびその他の国における商標です。 Microsoft
Windows Server
商標または登録商標です。Red Hat
の他の国における Red Hat, Inc. の登録商標です。SUSE™ は米国およびその他の国におけ
る Novell, Inc. の商標です。CitrixCitrix System, Inc. の登録商標または商標です。VMware
る VMware, Inc. の登録商標です。
本書では、上記記載以外の商標および会社名が使用されている場合があります。それらの
商標や会社名は、一切 Dell Inc. に帰属するものではありません。
システムに OS がプリインストールされている場合は、システムに同梱
の OS のマニュアルを参照してください。OS を初めてインストールす
る場合は、お使いの OS のインストールと設定に関するマニュアルを参
照してください。システムとは別途に購入したハードウェアやソフト
ウェアのインストールは、OS がインストール済みであることを確認し
てから行ってください。
対応 OS
•
Microsoft Small Business Server 2011 Standard/Essential Edition
•
Microsoft Windows Server 2008(x64)R2 SP1
Web/Standard/Foundation/Enterprise Edition
•
Microsoft Windows Server 2008 R2 (x64)
Web/Standard/Foundation/Enterprise Edition
•
Microsoft Windows Server 2008 SP2(x86
Web/Standard/Enterprise Edition
•
Microsoft Windows Server 2008 SP2(x64
Web/Standard/Enterprise Edition
42はじめに
)
)
Page 45
•
Microsoft Windows Server 2008 R2 SP1(x64) Hyper-V
Standard/Enterprise Edition
•
Microsoft Windows Server 2008 R2 (x64) Hyper-V
Standard/Enterprise Edition
•
Microsoft Windows Server 2008 SP2 (x64) Hyper-V
Standard/Enterprise Edition
Dell Inc.의 서면 승인 없이 어떠한 방식으로든 본 자료를 무단 복제하는 행위는 엄격히 금지
됩니다.
본 설명서에 사용된 상표 Dell™, DELL 로고 및 PowerEdge™는 Dell Inc.의 상표입니다. 미국
및 기타 국가에서 Intel
및 Windows Server
표입니다. Red Hat
의 등록 상표입니다. SUSE™는 미국 및 기타 국가에서 Novell, Inc.의 상표입니다. Citrix
XenServer
VMware
본 발행물에서 특정 회사의 상표 및 회사 이름 또는 제품을 지칭하기 위해 기타 상표 및 상호
를 사용할 수도 있습니다. Dell Inc.는 자사가 소유하고 있는 것 이외에 기타 모든 상표 및 상호
에 대한 어떠한 소유권도 없습니다.
®
는 미국 및/또는 기타 국가에서 Citrix Systems, Inc.의 등록 상표 또는 상표입니다.
®
는 미국 또는 기타 국가에서 VMWare, Inc.의 등록 상표 또는 상표입니다.
®
은 Intel Corporation의 등록 상표이고 Core™는 상표입니다. Microsoft®
®
는 미국 및/또는 기타 국가에서 Microsoft Corporation의 상표 또는 등록 상
®
및 Red Hat Enterprise Linux®는 미국 및/또는 기타 국가에서 Red Hat, Inc.
®
및
규정 모델 E10S 시리즈
2010 년 12 월P/N 30G7NRev. A00
Page 53
설치 및 구성
경고 : 다음 절차를 수행하기 전에 시스템과 함께 제공되는 안전 지침을 검토
하십시오 .
시스템 포장 풀기
시스템 포장을 풀고 각 항목을 확인합니다
랙에 레일 및 시스템 설치
주의 : 폐쇄형 또는 멀티 유닛 랙 조립품에 설치할 경우 , 랙 환경의 작동 시 주
위 온도가 주위 실온보다 높을 수 있습니다 . 그러므로 , 해당 장비는 제조업체
가 지정한 주변 최대 온도 (Tma) 와 호환되는 환경에 설치되어야 합니다 .
내용은
한
57 페이지의 " 기술사양 " 을참조하십시오 .
.
자세
시스템과 함께 제공되는 안전 지침 및 랙 설치 지침에 따라 레일을 조립하고
시스템을 랙에 설치합니다
.
시스템 시작 안내서51
Page 54
선택사양 — 키보드 , 마우스 및 모니터 연결
키보드, 마우스 및 모니터(선택 사양)를 연결합니다
시스템 후면에 있는 커넥터에는 각 커넥터에 연결될 케이블이 표시된 아이
있습니다. 모니터의 케이블 커넥터에 있는 나사(해당하는 경우)를 단단
콘이
히
고정하십시오
.
.
전원 케이블 연결
시스템의 전원 케이블을 시스템에 연결하고, 모니터를 사용하는 경우 모니
터의
전원 케이블을 모니터에 연결합니다
.
52시스템 시작 안내서
Page 55
전원 케이블 고정
그림과 같이 시스템 전원 케이블을 구부려서 고정 클립으로 케이블을 고정
합니다
.
전원 케이블의 반대쪽 끝을 접지된 전원 콘센트나, 무정전 전원 공급 장치
(UPS)
또는 배전 장치
(PDU)와
같은 별도의 전원에 연결합니다
.
시스템 켜기
시스템 및 모니터의 전원 단추를 누릅니다. 전원 표시등이 켜집니다
시스템 시작 안내서53
.
Page 56
베젤 ( 선택 사양 ) 설치
베젤(선택 사양)을 설치합니다
.
운영 체제 설치 완료
시스템 구입 시 운영 체제가 미리 설치되어 있는 경우 시스템과 함께 제공되
운영
는
제
웨어
하십시오
체제 설명서를 참조하십시오. 운영 체제를 처음 설치하려면 운영 체
설치 및 구성
또는 소프트웨어를 설치하기 전에 운영 체제가 설치되어 있는지 확인
설명서를 참조하십시오. 시스템과 함께 구입하지 않은 하드
.
지원되는 운영 체제
•Microsoft Small Business Server 2011 Standard 및 Essential Edition
•Microsoft Windows Server 2008 R2 SP1(x64) Web, Standard, Foundation
및
Enterprise Edition
•Microsoft Windows
및
Enterprise Edition
•Microsoft Windows Server 2008 SP2(x86) Web, Standard
및
Enterprise Edition
•Microsoft Windows Server 2008 SP2(x64) Web, Standard
및
Enterprise Edition
•Hyper-V
Enterprise Edition
포함
Server 2008 R2(x64) Web, Standard, Foundation
Microsoft Windows Server 2008 R2 SP1(x64) Standard및
54시스템 시작 안내서
Page 57
•Hyper-V 포함 Microsoft Windows Server 2008 R2(x64) Standard및
Enterprise Edition
•Hyper-V
Enterprise Edition
•VMware ESX 4.1 Update 1(Classic)
•VMware ESX 4.1 Update 1(Embedded)
•Citrix XenServer 5.6 Feature Pack 1
•Red Hat Enterprise Linux
•SUSE Linux Enterprise Server 11 SP1(x86_64)
주: 지원되는운영체제에대한최신정보는support.dell.com을참조하십시오.
포함
Microsoft Windows Server 2008 SP2(x64) Standard및
6.0(x86_64)
Dell 소프트웨어라이센스계약서
•
시스템을 사용하기 전에 시스템과 함께 제공된
계약서를 읽어보십시오
•Dell
•
에서 설치한 모든 소프트웨어의
하드 디스크 드라이브에 설치된 소프트웨어의 백업 복사본으로 간주해야
합니다
.
계약서 내용에 동의하지 않으면 고객 지원 전화 번호로 연락하십시오. 미
거주하는 고객은
국에
미국 이외의 지역에 거주하는 고객은 support.dell.com을
맨
위에서 해당 국가 또는 지역을 선택하십시오
지
.
CD, DVD 또는
800-WWW-DELL(800-999-3355)로
Dell
소프트웨어 라이센스
디스켓은 시스템의
전화하십시오
방문하고 페이
.
.
시스템 시작 안내서55
Page 58
기타 필요한 정보
경고 : 시스템과 함께 제공되는 안전 및 규제 정보를 참조하십시오 . 보증 정
보는 이 문서에 포함되거나 별도의 문서로 제공될 수 있습니다 .
•
랙 솔루션과 함께 제공되는 랙 설명서에는 시스템을 랙에 설치하는 방법
기술되어 있습니다
이
소유자 설명서에서는 시스템 기능에 대한 정보를 제공하고 시스템 문제
•
해결 방법 및 시스템 구성요소 설치 또는 교체 방법을 설명합니다. 이 문
support.dell.com/manuals에서
서는
운영 체제, 시스템 관리 소프트웨어, 시스템 업데이트 및 시스템과 함께
•
구입한 시스템 구성요소와 관련된 설명서 및 도구를 비롯하여 시스템을
구성 및 관리하는 데 필요한 설명서 및 도구를 제공하는 모든 매체가 시스
함께
템과
제공됩니다
주: 새로운 업데이트가 없는지 support.dell.com/manuals에서 항상 확인하
십시오. 업데이트에는 최신 정보가 수록되어 있으므로 다른 문서를 읽기
전에 반드시 먼저 참조하시기 바랍니다.
.
온라인으로 볼 수 있습니다
.
.
기술 지원 얻기
본 안내서의 절차가 이해되지 않거나 시스템이 제대로 작동하지 않을 경우
에는
소유자 설명서를 참조하십시오
증을
제공합니다. 자세한 내용은 dell.com/training을
따라 이 서비스가 제공되지 않을 수도 있습니다
. Dell은
포괄적인 하드웨어 교육 및 인
참조하십시오. 지역에
.
56시스템 시작 안내서
Page 59
기술 사양
프로세서
프로세서 유형
확장 버스
버스 종류
확장 슬롯전체 높이, 절반 길이
메모리
아키텍처
Intel Core
또는
Intel Xeon
또는
Intel Pentium
PCI Express Generation 2
1066MHz 및 1333MHz DDR3 Unbuffered
ECC(Error Correcting Code) DIMM
프로세서
프로세서
프로세서 1개(사용 가능한 경우
(i3-2100
(E3-1200
x16 링크 1
제품군
제품군
개
) 1
) 1
개
개
)
메모리 모듈 소켓
모듈
드라이브
용량
메모리
최소
RAM
최대
RAM
드라이브
하드 드라이브
광학
240핀 4
개
1GB, 2GB, 4GB 또는 8GB
1GB
32GB
3.5인치
이브
또는
2.5인치
이브
내장형
이브
케이블 방식
최대 2
개
케이블 방식
최대 2
개
SATA DVD-ROM 또는 DVD+/-RW
1개(옵션)
SAS 또는 SATA
SAS 또는 SATA
주: DVD 장치는데이터전용입니다.
외부
USB DVD-ROM(선택 사양)
시스템 시작 안내서57
내장형 드라
내장형 드라
드라
Page 60
커넥터
후면
NIC
직렬
USB
비디오
eSATA
전면
비디오
USB
내부
USB
비디오
비디오 종류
비디오 메모리
Power( 전원 )
AC 전원 공급 장치(전원 공급
와트
전압
열 손실최대
최대 유입 전류일반적인 회선 상태 및 전체 시스템 작동 범위에
배터리
시스템 배터리
장치당
내장형
RJ-45(
9핀, DTE, 16550
핀 2개
4
15핀 VGA
핀 커넥터 1개
7
15핀 VGA
4
핀 2개
핀 2개
4
Winbond WPCM450에
8MB
)
250W
100VAC–240VAC, 50Hz/60Hz, 4.0A–2.0A
1040BTU/hr
최대 25A의
서
CR 2032 3.0V 리튬 코인
1GB NIC용) 2
호환
, USB 2.0
, USB 2.0
, USB 2.0
호환
호환
호환
전류가 유입될 수 있습니다
개
내장된
셀
Matrox G200
.
58시스템 시작 안내서
Page 61
실제
높이
너비
깊이
무게(최대 구성 시
환경
)
4.24cm(1.67인치)
43.4cm(17.09인치)
39.37cm(15.5인치)
8.058kg(17.77lb)
주: 특정 시스템 구성을 위한 환경 측정에 대한 자세한 내용은
dell.com/environmental_datasheets를 참조하십시오.
온도
작동
10°C ~ 35°C(50°F ~ 95°F),
°C의 온도 변화 기준
10
주: 2,950피트 이상의 고도에서 최대 작동 온도
는 1°F/550ft로 감소됩니다.
보관
상대 습도
작동
보관
최대 진동
작동
보관
–40°C ~ 65°C(–40°F ~ 149°F),
°C의 온도 변화 기준
20
20% ~ 80%(
화
기준
5 ~ 95%(
5Hz–350Hz에서 15분 동안 0.26Grms
10Hz–500Hz에서 15분 동안 1.87Grms
비응축
비응축
),
시간당 최고
)
시간당 최고
시간당 최고
10%의 습도
변
시스템 시작 안내서59
Page 62
환경 ( 계속 )
최대 충격
작동작동 방향으로
펄스 1회(
격
보관최대
고도
작동
2ms 동안 (+/-) x, y, z
펄스 6회(시스템 각 면에 1회의 펄스
속도 변화가
(+/-) x, y, z
의
각 면에 1회의 펄스
–16m ~ 3,048m(–50ft ~ 10,000ft)
주: 2,950피트 이상의 고도에서 최대 작동 온도
는 1°F/550ft로 감소됩니다.
보관
공기 중 오염 물질 수준
등급
–16m ~ 10,600m(–50ft ~ 35,000ft)
ISA-S71.04-1985의
2.6ms 동안 (+) z
시스템 각 면에 1회의 펄스
686cm/초(270인치/초)인 32G
축으로 연속 충격 펄스 6회(시스템
)
규정에 따른
축으로
축으로
G1
31G의
)
71G의 연속 충격
)
구형파
충
60시스템 시작 안내서
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.