Dell OpenManage Baseboard Management Controller User Manual

Dell OpenManage Baseboard
Management Controller
Utilities 4.3

User’s Guide

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
instructions are not followed.
____________________
Information in this publication is subject to change without notice. © 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL™ logo, OpenManage™, PowerVault™, PowerConnect™, and PowerEdge™ are trademarks of Dell Inc. Microsoft
®
Server
, and MS-DOS® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat trademarks of Red Hat, Inc. in the United States and/or other countries. SUSE™ is a registered trademark of Novell, Inc. Intel countries. UNIX
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
®
is a registered trademark of The Open Group.
®
is a registered trademark of Intel Corporation in the U.S. and other
®
and Red Hat Enterprise Linux® are registered
®
, Windows®, Windows
July 2010

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 9
Supported Systems and Operating Systems. . . . . . . 10
BMC Configuration and Management Tasks . . . . . . 10
Configuring the BMC
. . . . . . . . . . . . . . . . 10
Managing the System Using BMC . . . . . . . . . 11
BMC Action on Event
Basic BMC Alerting Over a LAN
. . . . . . . . . . . . . . . . 13
. . . . . . . . . . 13
IPMI Shell Over a LAN . . . . . . . . . . . . . . . 14
IPMI Shell Over the Serial Cable
SOL Proxy Over a LAN
. . . . . . . . . . . . . . . 18
. . . . . . . . . . 16
BMC Configuration and Management Tools
. . . . . . 20
Using the Remote Access Configuration Utility
in x9xx systems
. . . . . . . . . . . . . . . . . . . 20
Using Deployment Toolkit. . . . . . . . . . . . . . 20
Using the BMC Management Utility
Using Server Administrator
Other Dell Documents You May Need
Obtaining Technical Assistance
. . . . . . . . 20
. . . . . . . . . . . . . 21
. . . . . . . . . . 21
. . . . . . . . . . . . 23
2 Configuring Your Managed System . . . . . 25
BIOS Configuration . . . . . . . . . . . . . . . . . . . 25
Configuring System BIOS in Dell
PowerEdge x8xx/x9xx Systems
. . . . . . . . . . . 26
Contents 3
Configuring System BIOS in Dell
PowerEdge x9xx and xx0x Systems. . . . . . . . . 27
Configuring System BIOS in Dell
PowerEdge xx1x Systems. . . . . . . . . . . . . . 29
Using BIOS Console Redirection
With SOL Proxy . . . . . . . . . . . . . . . . . . . 30
Baseboard Management Controller Configuration . . . 31
Entering the Remote Access Configuration
Utility in x9xx systems
Remote Access Configuration Utility Options
. . . . . . . . . . . . . . . . 32
. . . 32
Configuring Your BMC Using the Deployment Toolkit Utility
. . . . . . . . . . . . . . . . . . . . . . . 40
Installation and Setup for Microsoft Windows PE Operating Systems
. . . . . . . . . . . . . . . . 40
Creating a Bootable Windows PE 2005
ISO Image . . . . . . . . . . . . . . . . . . . . . . 41
Creating a Bootable Windows PE 2.0
ISO Image . . . . . . . . . . . . . . . . . . . . . . 43
Installation and Setup for Linux Operating Systems
. . . . . . . . . . . . . . . . . . . . . . . 44
Basic configuration . . . . . . . . . . . . . . . . . 45
3 Using the BMC Management Utility . . . 51
4 Contents
Configuring Your BMC Using Server Administrator
Using Dell Remote Access Controller 5
. . . 48
. . . . . . 49
Installing the BMC Management Utility . . . . . . . . . 52
Installation Prerequisites
Installation Procedures
. . . . . . . . . . . . . . 53
. . . . . . . . . . . . . . . . . 53
Installing on Systems Running Supported Windows Operating Systems
. . . . . . . . . . . . 54
Uninstalling on Systems Running Supported
Windows Operating Systems . . . . . . . . . . . . 55
Installing on Systems Running Supported
Linux Enterprise Operating Systems . . . . . . . . 56
Uninstalling on Systems Running Supported
Linux Enterprise Operating Systems . . . . . . . . 57
IPMI Shell
. . . . . . . . . . . . . . . . . . . . . . . . 57
Using IPMI Shell
IPMI Shell Command Syntax
IPMI Shell Global Options
. . . . . . . . . . . . . . . . . . 59
. . . . . . . . . . . . 59
. . . . . . . . . . . . . 60
IPMI Shell Commands . . . . . . . . . . . . . . . 66
SOL Proxy . . . . . . . . . . . . . . . . . . . . . . . . 78
Using SOL Proxy
. . . . . . . . . . . . . . . . . . 81
Using SOL proxy in command mode . . . . . . . . 91
Configuring the SOL Proxy Configuration File
IPMItool
. . . . . . . . . . . . . . . . . . . . . . . . . 96
IPMItool Command for Dynamic Entry on the DNS Server When DRAC is Not Present
. . . . . . 102
4 Known Issues and Frequently Asked
Questions . . . . . . . . . . . . . . . . . . . . . . . 109
Known Issues . . . . . . . . . . . . . . . . . . . . . . 109
General Issues
SOL Proxy Issues
IPMI Shell Issues
. . . . . . . . . . . . . . . . . . . 109
. . . . . . . . . . . . . . . . . . 109
. . . . . . . . . . . . . . . . . . 110
. . . 93
Frequently Asked Questions
. . . . . . . . . . . . . . . 110
Contents 5
A BMC Management Utility Error
Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
B Terminal Mode Commands . . . . . . . . . . 117
Configuring Terminal Mode . . . . . . . . . . . . 117
Using Terminal Mode
. . . . . . . . . . . . . . . 118
Security Information
. . . . . . . . . . . . . . . . . . 118
Syntax . . . . . . . . . . . . . . . . . . . . . . . . . 119
Command Length
. . . . . . . . . . . . . . . . . 119
Character Support . . . . . . . . . . . . . . . . 119
Hex-ASCII Command Format. . . . . . . . . . . . . . 120
Text Command Format
Examples
. . . . . . . . . . . . . . . . . 120
. . . . . . . . . . . . . . . . . . . . . 121
C Escape Key Sequences . . . . . . . . . . . . . 129
D Serial Port Console Redirection
Serial Communication . . . . . . . . . . . . . . . . . 131
Console Redirection Via COM1
Console Redirection Via COM2
Serial Terminal Communication to
BMC or DRAC . . . . . . . . . . . . . . . . . . . 132
SPCR Table . . . . . . . . . . . . . . . . . . . . . . . 132
. . . . . . 131
. . . . . . . . . . 131
. . . . . . . . . . 131
6 Contents
Serial Console redirection With SOL Proxy
. . . . . . 133
Configuring Linux for Serial Redirection During Boot
. . . . . . . . . . . . . . . . . . . . 133
Enabling Login to the Console After Boot. . . . . 135
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Contents 7
8 Contents
1

Introduction

The Dell systems’ Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and logs events when certain parameters exceed their preset thresholds. The BMC supports the industry-standard Intelligent Platform Management Interface (IPMI) specification, enabling you to configure, monitor, and recover systems remotely. The BMC provides the following features:
Access through the system’s serial port and integrated NIC
Fault logging and SNMP alerting
Access to the system event log (SEL) and sensor status
Control of system functions including power on and power off
Support that is independent of the system’s power or operating state
Text console redirection for system setup, text-based utilities, and operating system consoles
Access to Linux Enterprise server serial console interfaces by using Serial over LAN (SOL).
Dell provides several distinct utilities and programs for accessing the BMC to perform management activities. The following BMC interfaces allow you to configure and manage your system through the BMC:
The BMC Management Utility allows remote, out-of-band LAN and/or serial port power control, event log access, and console redirection.
The Remote Access Configuration Utility in configuring BMC in a pre-operating system environment.
The Dell OpenManage Deployment Toolkit SYSCFG utility provides a powerful command line configuration tool.
Dell OpenManage Server Administrator allows remote, in-band access to event logs, power control, and sensor status information and provides the ability to configure the BMC.
Command Line Interface (CLI) tools provide a command line tool for sensor status information, System Event Log (SEL) access, and power control.
x9xx
systems enables
Introduction 9
Additionally, the BMC can be accessed by standard, off-the-shelf terminal or terminal emulator utilities that allow access to sensor status information and power control.

Supported Systems and Operating Systems

BMC Management Utility supports new Dell systems running supported Microsoft Windows and Linux systems by implementing the new IPMItool commands to monitor your system’s power, view, and set the LCD status.
For the complete list of supported systems and operating systems, see the
readme.txt file in the root installation folder, or the Dell Systems Software Support Matrix available on the Dell Support website at
support.dell.com/manuals.
NOTE: All references in this document to x9xx systems also apply to the
PowerVault NX1950, PowerVault 500, and PowerVault 600 systems. All references to the PowerEdge 840 system also apply to the PowerVault 100 system.
NOTE: The new power monitoring features are not supported on IPMIsh and
SOLProxy.

BMC Configuration and Management Tasks

The following sections document the basic tasks needed to set up and configure the BMC on a managed system in preparation for using the BMC Management Utility. These basic tasks are:
•Configuring the BMC
•Managing the BMC
Configuring the BMC
To configure the BMC on a managed system in a pre-boot environment, you can use:
Dell Deployment Toolkit (DTK)
Remote Access Configuration Utility in
NOTE: The Remote Access Configuration Utility is called the BMC Setup Module in
Dell PowerEdge x8xx systems, iDRAC Configuration Utility in xx0x systems, and iDRAC6 Configuration Utility in xx1x systems.
10 Introduction
x9xx
systems
Dell Remote Access Controller (DRAC) 5 graphical user interface (GUI)
iDRAC6 Enterprise graphical user interface (GUI)
Command Line Interface (CLI)
from a management station depending on the scope of your required configuration tasks. Alternately, you can configure the BMC on a managed system with a running operating system using the Server Administrator home page GUI or CLI. See "Baseboard Management Controller Configuration" on page 31 for more information.
Managing the System Using BMC
To manage the BMC in a pre-boot environment, or to access the BMC of a system, you can use the BMC Management Utility. See "Using the BMC Management Utility" on page 51. To configure the BMC on a system with a running operating system or to perform everyday BMC management tasks, you can use the GUI on the Server Administrator home page. See the Server Administrator User’s Guide for more information about using Server Administrator to manage your system’s BMC functions. Figure 1-1 shows the configuration matrix for BMC.
Introduction 11
Figure 1-1. BMC Configuration Matrix
12 Introduction
BMC Action on Event
If you plan to use your system’s BMC to perform actions when events occur, you must follow the BMC Action on Event configuration guidelines listed in Ta b l e 1 - 1 .
Table 1-1. BMC Action on Event Configuration Guidelines
Features Connection
Medium
•System
Reset
•System
Power Off
•System
Power Cycle
LAN
BMC Configuration Tools
• Deployment Toolkit (pre-operating system environment)
• Server Administrator
Basic Configuration Ta sk s
•Enable platform events
•Enable alert actions
Management Tools
NA
Basic BMC Alerting Over a LAN
If you plan to use your system’s BMC to send alerts (Platform Event Traps), you must follow the BMC configuration guidelines listed in Table 1-2.
NOTE: The LAN-sharing depends on the NIC selection configuration option.
The available options are Shared and Failover. If you are using iDRAC6 Enterprise, the additional option available is Dedicated. See the NIC Selection option in the table in "Remote Access Configuration Utility Options" on page 32 for more information on Shared, Failover, and Dedicated.
Introduction 13
Table 1-2. BMC LAN Alerting Configuration Guidelines
Features Connection
Medium
Platform Event Alerts (SNMP Tr a ps )
LAN
BMC Configuration Tools
•Remote Access Configuration
x9xx
Utility in systems (pre-operating system environment)
•Deployment To ol k i t (pre-operating system environment)
•Server Administrator
Basic Configuration Tas ks
1
Configure NIC Selection to select Shared, Failover, or Dedicated
NOTE: This option is
available only on Dell PowerEdge
x9xx, xx0x, and xx1x
systems.
2
Configure the IP address, Subnet mask, and Gateway on the managed system
3
Configure the VLAN (optional)
4
Enable alerting
5
Configure the Alert destination IP address
6
Configure the Host Name (optional)
Management Tools
IT Assistant
IPMI Shell Over a LAN
Table 1-3 lists the actions you can perform, if you plan to use the BMC Management Utility’s IPMI Shell or IPMItool to access your system’s BMC over a LAN.
14 Introduction
Table 1-3. BMC LAN Access Configuration Guidelines
Features Connection
Medium
• Remote SEL
LAN
access
•Power control
•System identification
•Sensor information
BMC Configuration Tools
• Remote Access Configuration
x9xx
Utility in systems (pre-operating system environment)
• Deployment Toolkit (pre-operating system environment)
•Server Administrator
Basic Configuration Tas ks
1
Enable IPMI over LAN on the managed system
2
Configure NIC selection to select Shared, Failover, or Dedicated
NOTE: This
option is available only on Dell PowerEdge
x9xx, xx0x, and xx1x systems.
3
Configure the IP address, Subnet mask, and Gateway on the managed system
4
Configure IPMI encryption key (optional)
NOTE: This
option is available only on Dell PowerEdge
x9xx, xx0x, and xx1x systems.
5
Configure VLAN (optional)
6
Configure BMC users
Management Tools
IPMI Shell
Introduction 15
IPMI Shell Over the Serial Cable
If you plan to use the BMC Management Utility’s IPMI Shell to access your system’s BMC over a serial cable, you must follow the BMC configuration guidelines listed in Table 1-4.
NOTE: Console redirection does not apply to BMC when using the serial interface.
Table 1-4. BMC Serial Configuration Guidelines
Features Connection
Medium
•Interactive mode
•Remote SEL access
•Power control
•System identification
•System information
•Access the BMC of the remote system
Accessed through the serial channel by using a null modem cable
BMC Configuration Tools
•BIOS (pre-operating system environment)
• Deployment To ol k i t (pre-operating system environment)
•Server Administrator (to enable BMC serial only)
Basic Configuration Ta sk s
1
Configure Serial Port 1 to BMC Serial
NOTE: This
option is available only on Dell PowerEdge
x8xx systems.
2
Configure External Serial Connector to Remote Access
NOTE: This
option is available only on Dell PowerEdge
x9xx, xx0x, and xx1x systems.
Management Tools
• IPMI Shell (Basic mode)
•Terminal emulation (Terminal mode only)
16 Introduction
Table 1-4. BMC Serial Configuration Guidelines
(continued)
Features Connection
Medium
•System information
•Access the BMC of the remote system
BMC Configuration Too ls
Basic Configuration Tas ks
3
Set Serial baud rate to match the rate to be used by the management tool
4
Set BMC Serial Connection Mode to Basic for IPMI Shell or Terminal for Te rm i n al emulation
5
Configure BMC users
Management Too ls
Introduction 17
SOL Proxy Over a LAN
If you plan to use the BMC Management Utility’s SOL Proxy to access your system’s console over a LAN, you must follow the BMC configuration guidelines listed in Table 1-5.
Table 1-5. BMC SOL Configuration Guidelines
Features Connection
Medium
• Text Utility console redirection
•Remote BIOS setup
•Microsoft text console redirection
•Linux text console redirection
LAN
BMC Configuration Tools
•BIOS (pre-operating system environment)
• Remote Access Configuration
x9xx
Utility in systems (pre-operating system environment)
•Deployment Toolkit (pre-operating system environment)
•Server Administrator
Basic Configuration Tas ks
1
Configure Serial Port 1 to BMC NIC
NOTE: This
option is available only on Dell
PowerEdge x8xx
systems.
2
Configure BIOS console redirection to Serial Port 1.
NOTE: This option
is available only on Dell
PowerEdge x9xx
systems.
3
Configure Console Redirection to On with Console Redirection via COM2
NOTE: This option
is available only on Dell
PowerEdge x9xx, xx0x, and xx1x
systems.
Management Too ls
•SOL Proxy
•IPMI Shell
18 Introduction
Table 1-5. BMC SOL Configuration Guidelines
(continued)
Features Connection
Medium
•Force a reboot on a remote system and activate console redirection
•Access BMC of the remote system
BMC Configuration Tools
Basic Configuration Ta sk s
4
Configure other Console Redirection parameters, such as baud rate, emulation type, and so on.
5
Enable IPMI over LAN on the managed system
6
Configure the IP address, Subnet mask, and Gateway on the managed system
7
Configure IPMI encryption key (optional)
NOTE: This
option is available only on Dell
PowerEdge x9xx, xx0x, and xx1x
systems.
8
Configure VLAN (optional)
9
Configure BMC users
Management Tools
Introduction 19

BMC Configuration and Management Tools

Using the Remote Access Configuration Utility in
The Remote Access Configuration Utility in x9xx systems provides basic BMC setup and configuration functions that can be accessed during system boot. Use the utility for initial BMC setup and configuration only. For advanced configuration tasks, you must use the Deployment Toolkit SYSCFG utility or Server Administrator Version 2.0 or later.
NOTE: The Remote Access Configuration Utility is called the BMC Setup Module in
Dell PowerEdge x8xx systems, iDRAC Configuration Utility in xx0x systems, and iDRAC6 Configuration Utility in xx1x systems.
x9xx
systems
Using Deployment Toolkit
The Deployment Toolkit (DTK) SYSCFG utility provides a powerful Microsoft Windows Preinstallation Environment (PE) and Linux command an initial deployment. Use the DTK SYSCFG utility to set all supported BMC features. Additionally, you can use the Deployment Toolkit utilities to capture and replicate system settings on similar systems. See "Configuring Your BMC Using the Deployment Toolkit Utility" on page 40 for more information on how to install and set up the DTK SYSCFG utility.
-line interface for locally configuring your system’s BMC as part of
Using the BMC Management Utility
The BMC Management Utility provides a command-line interface to your remote management station to manage BMC-supported functions. Use the BMC Management Utility to manage your BMC from a remote management station and as your managed system’s emergency management console. The utility gives you the option of using either a command line interface (IPMI Shell) or a SOL Proxy to access and manage the BMC. To use the BMC Management Utility, you must perform the following tasks:
Configure BMC using the Remote Access Configuration Utility in systems, the DTK SYSCFG utility, or Server Administrator.
Install the BMC Management Utility on a management station.
See "Configuring Your Managed System" on page 25 for instructions on configuring the BMC on a managed system in preparation for using the BMC Management Utility.
x9xx
20 Introduction
Using Server Administrator
The Server Administrator provides a convenient and easy-to-use GUI for remotely configuring or managing your system’s BMC on a system running a supported operating system. You can use the Server Administrator to configure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations. Additionally, Server Administrator can be used as a command line interface. Server Administrator requires that the system has an operating system installed and functioning. As a result, Server Administrator is best suited for everyday BMC management tasks, and is not an option for performing pre-boot setup or accessing the BMC as an emergency management console. To use Server Administrator, you must perform the following tasks:
Install Server Administrator on the managed system.
Access the Server Administrator home page remotely or locally from a supported browser on a management station.
Configure BMC remotely or locally on the managed system.
See the Dell OpenManage Server Administrator User’s Guide and Command line Interface User’s Guide on the Dell Support website at support.dell.com/manuals for more information about using Server Administrator to configure and manage your system BMC.

Other Documents You May Need

In addition to this guide, you can access the following guides available on the Dell Support website at support.dell.com/manuals. On the Manuals page, click Software on the right-side to access the documents.
•The overview of applications that you can install on your management station (console) and on your managed systems and procedures for installing your console and managed system applications on systems running supported operating systems.
•The additional information about using Server Administrator to manage your system’s BMC.
Systems Management. Click on the appropriate product link
Dell OpenManage Software Quick Installation Guide
Dell OpenManage Server Administrator User’s Guide
provides an
provides
Introduction 21
•The
•The
•The
•The
•The
•The
The Dell system
•The
•The
•The
•The
Dell OpenManage Deployment Toolkit User’s Guide
additional information about installing and using the DTK utilities.
Dell OpenManage Deployment Toolkit Command Line Interface
Reference Guide
command-line options, suboptions, and arguments.
Dell OpenManage IT Assistant User’s Guide
about how to monitor and manage a large number of client and server systems on a local area network (LAN) or wide area network (WAN).
Dell Remote Access Controller 5 User’s Guide
information about installing and configuring a DRAC 5 and using DRAC 5 to remotely access an inoperable system.
Integrated Dell Remote Access Controller User’s Guide
detailed information on configuring and using the iDRAC.
Dell Systems Software Support Matrix
various Dell systems, the operating systems supported by these systems, and the Dell OpenManage components that can be installed on these systems.
configuring your BIOS settings with the System Setup Program, as well as instructions for configuring your system to use console redirection.
Integrated Dell Remote Access Controller 6 (iDRAC6) Enterprise for
Blade Servers User Guide
using an iDRAC6 for blade servers to remotely manage and monitor your system and its shared resources through a network.
Integrated Dell Remote Access Controller 6 (iDRAC6) User Guide
provides complete information about configuring and using an iDRAC6 for tower and rack servers to remotely manage and monitor your system and its shared resources through a network.
iDRAC Administrator Reference Guide
the RACADM subcommands, supported interfaces, and iDRAC6 property database groups and object definitions.
Glossary
provides a complete list of all valid BMC-related
provides information
provides information about the
User’s Guide
provides information about the terms used in this document.
provides supplemental information about
provides information about configuring and
provides information about
provides
provides complete
provides
22 Introduction
Additionally, the Dell OpenManage readme.txt file provides the latest available information for the installation and operation of the programs and utilities used to manage your system through the BMC. The readme is available on the Dell Systems Management Tools and Documentation DVD and on the Dell Support website at support.dell.com/manuals.

Obtaining Technical Assistance

If at any time you do not understand a procedure described in this guide or if your product does not perform as expected, help tools are available to assist you. For more information about these help tools, see "Getting Help" in your system's Installation and Troubleshooting Guide or the Hardware Owner’s Manual.
Additionally, Dell Enterprise Training and Certification is available; see www.dell.com/training for more information. This service may not be offered in all locations.
Introduction 23
24 Introduction
2

Configuring Your Managed System

Before using the BMC Management Utility, configure certain items, such as the necessary system BIOS, network, Intelligent Platform Management Interface (IPMI) encryption key, and serial connection settings, depending on the functionality to be performed, to enable access to the BMC.
NOTE: The IPMI encryption key is a public key that is used to generate an
encryption key for use between the firmware and the application.
In addition, to utilize the BMC Management Utility IPMI serial functions, you must have a working connection between the management station and the correct serial I/O port of the target BMC, using a null modem cable.
This section describes the basic procedures you must perform to prepare your BMC to be accessed and managed using the BMC Management Utility. The following procedures are described:
BIOS Configuration
Baseboard Management Controller Configuration
Configuring your BMC with the Dell OpenManage Deployment ToolKit (DTK) SYSCFG utility
Configuring your BMC with Dell OpenManage Server Administrator

BIOS Configuration

For most configurations, you must configure the serial port settings and the console redirection settings in your system BIOS before you can use the BMC Management Utility. To configure the necessary system BIOS setting, your must enter the System Setup Program. The BIOS settings can also be configured using the Deployment Toolkit or the
NOTE: For more information about configuring BIOS settings, see your system
User’s Guide.
Configuring Your Managed System 25
Server Administrator.
Configuring System BIOS in Dell PowerEdge x8
1
Turn on or restart your system.
2
Press <F2> immediately after you see the following message:
xx/x9xx
<F2> = Setup
The
System Setup
NOTE: If the operating system begins to load before you press <F2>,
allow your system to boot, and then restart your system, and try again.
3
Use the up- and down- arrow keys to navigate to the
screen appears.
field and press <Enter>.
4
Use the up- and down- arrow keys to navigate to the press <Enter>.
5
Use the space bar to select the serial port option.
The options are
COM1, COM3, BMC Serial, BMC NIC, Off
(if an optional RAC is installed in the system).
Systems
Integrated Devices
Serial Port 1
field and
, and
RAC
To use BMC, serial port 1 uses the
COM1
address and communication can be through the serial port or the integrated shared NIC. RAC control uses only the
COM1
address.
Off
and
COM3
are not available options
when Console Redirection is set to use serial port 1.
a
Select
BMC Serial
if you are planning to access the BMC through the
serial cable connection.
b
Select
BMC NIC
if you are using SOL proxy and are planning to
access the BMC over a shared LAN.
6
Press <Enter> to return to the
7
Use the up- and down- arrow keys to navigate to the
System Setup
screen.
Console Redirection
field and press <Enter>.
8
Use the up- and down- arrow keys to navigate to the
Console Redirection
option and then use the space bar to set the console redirection feature to
Serial Port 1
9
Use the up- and down- arrow keys to navigate to the
. Optionally, you can also enable
Redirection after Boot.
Failsafe Baud Rate
option and then use the space bar to set the console failsafe baud rate, if applicable.
26 Configuring Your Managed System
10
Use the up- and down- arrow keys to navigate to the
Ty p e
option and then use the space bar to select either
ANSI, if applicable.
11
Press <Enter> to return to the
12
Press <Esc> to exit the System Setup program. The the following options:
Save Changes and Exit
Discard Changes and Exit
Return to Setup
13
Choose the appropriate option and exit the system setup.
System Setup
screen.
Remote Terminal
VT 100/VT 200
Exit
screen displays
or
Configuring System BIOS in Dell PowerEdge x9
1
Turn on and restart your system.
2
Press <F2> immediately after you see the following message:
<F2> = Setup
The
System Setup
NOTE: If the operating system begins to load before you press <F2>,
allow your system to boot, and then restart your system, and try again.
3
Use the up- and down- arrow keys to navigate to the
Communication
4
Use the spacebar to select the appropriate serial communication option.
5
Press <Enter> to select the appropriate option for Console Redirection. The following options are available:
On without Console Redirection:
available for use by the operating system or applications. Console redirection is disabled. This is the default option.
On with Console Redirection via COM1:
redirection is enabled through COM1, the COM1 port is not available to applications through the operating system.
On with Console Redirection via COM2:
redirection is enabled through COM2, the COM2 port is not available to applications through the operating system.
screen appears.
field and press <Enter>.
COM1 and COM2 are enabled and
xx
and xx0x Systems
Serial
When BIOS console
When BIOS console
Configuring Your Managed System 27
Off:
COM1 and COM2 are both disabled and not available for use by the
operating system or applications. BIOS Console redirection is disabled.
NOTE: Select On with Console Redirection via COM2 to use Console
Redirection with SOL.
6
Use the up- and down- arrow keys to navigate to the
Communication
7
Use the spacebar to select the appropriate external serial communication
field and press <Enter>.
External Serial
option.
The available options are The default option is
NOTE: Select Remote Access to access the BMC through the serial cable
connection. This option can be set to any value for using SOL and accessing the BMC over LAN.
8
Press <Enter> to select.
9
If required, use the spacebar to navigate to and change the settings for
COM1, COM2
COM1
.
, and
Remote Access.
Redirection after Boot.
10
Use the up- and down- arrow keys to navigate to the
Failsafe Baud Rate
option and then use the space bar to set the console failsafe baud rate, if applicable.
11
Use the up- and down- arrow keys navigate to the option and then use the space bar to select either
Remote Terminal Type
VT 100/VT 200
if applicable.
12
Press <Enter> to return to the
13
Press <Esc> to exit the System Setup program. The
System Setup
screen.
Exit
screen displays
the following options:
Save Changes and Exit
Discard Changes and Exit
Return to Setup
or
ANSI,
NOTE: For most options, any changes that you make are recorded but do not take
effect until you restart the system.
NOTE: Press <F1> to display the help file for the System Setup program.
28 Configuring Your Managed System
Configuring System BIOS in Dell PowerEdge
1
Turn on and restart your system.
2
Press <F2> immediately after you see the following message:
xx1x
Systems
<F2> = Setup
The
System Setup
NOTE: If the operating system begins to load before you press <F2>,
allow your system to boot, and then restart your system, and try again.
3
Use the up- and down- arrow keys to navigate to the
Communication
4
Use the spacebar to select the appropriate serial communication option.
5
Press <Enter> to select the appropriate option for Console Redirection.
screen displays.
Serial
field and press <Enter>.
The following options are available:
On without Console Redirection:
COM1 and COM2 are enabled and available for use by the operating system or applications. Console redirection is disabled. This is the default option.
On with Console Redirection via COM1:
When BIOS console redirection is enabled through COM1, the COM1 port is not available to applications through the operating system.
On with Console Redirection via COM2:
When BIOS console redirection is enabled through COM2, the COM2 port is not available to applications through the operating system.
Off:
COM1 and COM2 are both disabled and not available for use by the
operating system or applications. BIOS Console redirection is disabled.
NOTE: Select On with Console Redirection via COM2 to use Console
Redirection with SOL.
6
Use the up- and down- arrow keys to navigate to the
Selection
7
Use the up- and down- arrow keys to navigate to the appropriate
Serial Connector
The available options are
field to select
option.
COM1
or
COM2
.
SerialDevice1, SerialDevice2
Serial Port Address
, and
Remote
Access Device.
NOTE: Use only SerialDevice2 for SOL.
Configuring Your Managed System 29
External
8
Use the up- and down- arrow keys to navigate to the
Failsafe Baud Rate
option and then use the space bar to set the console failsafe baud rate, if applicable.
9
Use the up- and down- arrow keys to navigate to the
Ty p e
option and then use the space bar to select either
ANSI,
if applicable.
10
Use the up- and down- arrow keys to navigate to and change the settings for
Redirection After Boot.
11
Press <Enter> to return to the
12
Press <Esc> to exit the System Setup program. The
System Setup
Remote Terminal
VT 100/VT 220
screen.
Exit
or
screen displays
the following options:
Save Changes and Exit
Discard Changes and Exit
Return to Setup
NOTE: For most options, any changes that you make are recorded but do not take
effect until you restart your system.
NOTE: Press <F1> to display the help file for the System Setup program.
Using BIOS Console Redirection With SOL Proxy
Console redirection allows maintenance of a system from a remote location by redirecting keyboard input and output through the serial port. Any console-based feature or operating system can then be used to access the server. DR-DOS, Linux (init 3) and Windows Special Administrative Console (SAC) are examples of operating systems and consoles that can be used to access the server.
By default, some operating systems, such as Windows Server 2003, are automatically configured to send text console output to the BIOS. Manual configuration of the Redirection after Boot feature through the system BIOS may not be visible to the operating system. This results in both, the operating system feature and the BIOS redirection feature, being enabled. Depending on the operating system and its setup, the results may vary. Dell recommends the following steps as good practice:
DR-DOS: Do not configure DR-DOS for serial console output. Enable console redirection after reboot in system BIOS.
30 Configuring Your Managed System
Windows Special Administrative Console (SAC): Do not configure Windows SAC for serial console redirection. Enable console redirection after reboot in system BIOS.
Linux: Do not configure console redirection after rebooting the system BIOS. Do the tasks listed in the "Installation and Setup for Linux Operating Systems" on page 44, to configure Linux for console redirection.
NOTE: See "Escape Key Sequences" on page 129 for a list of keystrokes to be used for
BIOS Setup operations from a serial terminal.

Baseboard Management Controller Configuration

You can perform basic BMC configuration using the Remote Access Configuration Utility in x9xx systems during system startup. See Figure 2-1. For more advanced configuration options, see the instructions for the DTK SYSCFG utility in the Deployment Toolkit User’s Guide.
NOTE: The Remote Access Configuration Utility in Dell PowerEdge x9xx systems is
called the BMC Setup Module in x8xx systems, iDRAC Configuration Utility in xx0x systems and iDRAC6 Configuration Utility in xx1x systems. For more information on the iDRAC Configuration Utility, see the Integrated Dell Remote Access Controller User’s Guide available on the Dell Support website at support.dell.com/manuals.
x9xx
Figure 2-1. Remote Access Configuration Utility in
systems
Configuring Your Managed System 31
Entering the Remote Access Configuration Utility in
1
Turn on or restart your system.
2
Press <
If your operating system begins to load before you press <
Ctrl-E
> when prompted after POST.
x9xx
systems
Crtl-E
>, allow
the system to finish booting, and then restart your system and try again.
Remote Access Configuration Utility Options
Table 2-1 lists the Remote Access Configuration Utility options and shows how to configure the BMC on a managed system. After entering all settings, press <Esc> and select one of the following:
Save Changes and Exit—
Configuration Utility.
Discard Changes and Exit
Configuration Utility.
Return to Setup
— Continue using the Remote Access Configuration
Utility.
Keep all entries made in the Remote Access
— Undo all entries made in the Remote Access
Table 2-1. Remote Access Configuration Utility in
Option Description
iDRAC6 LAN
NOTE: This option is
available in the iDRAC6 Configuration Utility on
Dell PowerEdge xx1x
systems.
IPMI Over LAN Enables or disables the out-of-band LAN channel access to
Enables or disables the iDRAC6 LAN. The LAN must be enabled to permit use of iDRAC6 facilities, such as the Web interface, telnet/SSH access to the SM-CLP command line interface, console redirection, and virtual media.
the shared network controller.
x9xx
systems
NOTE: When you select Off, the iDRAC will not accept IPMI
messages arriving over the LAN interface on Dell PowerEdge
xx1x systems.
32 Configuring Your Managed System
Table 2-1. Remote Access Configuration Utility in
Option Description
NIC Selection
NOTE: This option is
available only on Dell
PowerEdge x9xx, xx0x, and xx1x systems.
Displays the configuration option.
•Shared
Select this option to share the network interface with the host operating system. The remote access device network interface is fully functional when the host operating system is configured for NIC teaming.
The remote access device receives data through NIC 1 and NIC 2, but transmits data only through NIC 1.
If NIC 1 fails, the remote access device will not be accessible.
NOTE: The NIC 2 is not available on PowerEdge 1900
system.
•Failover
Select this option to share the network interface with the host operating system. The remote access device network interface is fully functional when the host operating system is configured for NIC teaming.
The remote access device receives data through NIC 1 and NIC 2, but transmits data only through NIC 1. If NIC 1 fails, the remote access device fails over to NIC 2 for all data transmission.
The remote access device continues to use NIC 2 for data transmission. If NIC 2 fails, the remote access device fails over all data transmission back to NIC 1.
NOTE: This option cannot be selected on the PowerEdge 1900
system.
x9xx
systems
(continued)
Configuring Your Managed System 33
Table 2-1. Remote Access Configuration Utility in
Option Description
•Dedicated
Select this option to enable the remote access device to utilize the dedicated network interface available on iDRAC6 Enterprise. This interface is not shared with the host operating system and routes the systems management traffic to a separate physical network, enabling it to be separated from the application traffic.
systems
(continued)
x9xx
NOTE: This option is available only on systems with iDRAC6
Enterprise.
LAN Parameters
RMCP+ Encryption Key
IP Address Source Displays whether the network controller will be assigned a
Ethernet IP Address The static IP address of the BMC. This field is limited to a
NOTE: This option is available only on PowerEdge x9xx,
xx0x,and xx1x systems.
The Key is used to encrypt the IPMI sessions. The encryption key is entered as a maximum of 20 pairs of ASCII hexadecimal characters representing 20 bytes. For example, 01FA3BA6C812855DA001FA3BA6C812855DA0A0A0.
Static IP address or a DHCP address.
maximum value of 255.255.255.255.
The following IPv4 rules apply:
• IP addresses cannot be between
• The first octet must be between
143.xxx.xxx.xxx
0-255
127.xxx.xxx.xxx
.
)
1-223
, where
(that is,
xxx
NOTE: IP address 169.254.0.2 subnet mask 255.255.0.0 is
returned when the BMC is unable to contact the DHCP server.
MAC Address This field is read-only.
Displays the network controller’s BMC MAC address.
Subnet Mask The subnet mask for the static IP address.
NOTE: IP address 169.254.0.2 subnet mask 255.255.0.0 is
returned when the BMC is unable to contact the DHCP server.
is
34 Configuring Your Managed System
Table 2-1. Remote Access Configuration Utility in
Option Description
Default Gateway The IP gateway for the static IP address.
VLAN Enable Enables or disables the virtual LAN ID.
VLAN ID This field is read-only when VLAN Enable is set to off.
To enter a value, navigate to the VLAN ID field from another field.
A valid value for the virtual LAN ID must be a number from 1 to 4094.
x9xx
systems
(continued)
NOTE: If you enter a value outside the specified range, either 1
or 4094 is entered, whichever is closest.
VLAN This field is read-only when VLAN Enable is set to off.
Specifies the priority of the VLAN. The valid values range from Priority 0 - Priority 7.
Register iDRAC6 Name
NOTE: This option is
available in the iDRAC6 Configuration Utility on
Dell PowerEdge xx1x
systems.
iDRAC6 Name
NOTE: This option is
available in the iDRAC6 Configuration Utility on
Dell PowerEdge xx1x
systems.
LAN Alert Enabled
Alert Policy Entry 1
Select On to register the iDRAC6 name in the DNS service.
Off
Select in DNS.
If edit the
Enter
< name. Press < iDRAC6 name must be a valid DNS host name.
Enables or disables LAN alerting.
Enables or disables the first alert destination.
if you do not want users to find the iDRAC6 name
Register iDRAC6 Name
Current DNS iDRAC6 Name
> when you have finished editing the iDRAC6
Esc
is set to On, press <
text field. Press
> to return to the previous menu. The
Enter
> to
Configuring Your Managed System 35
Table 2-1. Remote Access Configuration Utility in
x9xx
systems
(continued)
Option Description
Alert Destination 1 This field is read-only when LAN Alert Enabled is set to
off.
Enter the IP address of the first alert destination. Use the Left or Right arrow keys to navigate to each octet. Use the numeric keypad to enter each octet.
The following IPv4 rules apply:
• IP addresses cannot be between
0-255
• The first octet must be between
143.xxx.xxx.xxx
• The last octet must not be (i.e.
xxx.xxx.xxx.0
127.xxx.xxx.xxx
.
)
0
or
xxx.xxx.xxx.255
or
1-223
255
, where
xxx
is
(i.e.
)
Host Name String Specifies the managed system hostname used to correlate
Platform Event Traps to the system on which they originate.
Use alpha-numerics, but no symbols (except ’-’) or spaces.
Smart Card Logon Select Enabled to enable Smart Card logon. Enabling Smart
Card logon disables all CLI out-of-band interfaces. Select Disabled to disable Smart Card logon. All command line out­of-band interfaces are set to their default state. Select Enabled with RACADM to enable Smart Card logon along with remote RACADM. All other CLI out-of-band interfaces are disabled.
NOTE: This option is available only on xx0x and xx1x systems.
IPv6 Settings Specifies the LAN Configuration for IPv6.
NOTE: This option is available in the iDRAC6 Configuration
Utility on xx1x systems. See the Integrated Dell Remote Access Controller User’s Guide available on the Dell Support website
at support.dell.com/manuals for more information.
Advanced LAN Parameters
Dedicated NIC Configuration Options
NIC Enables or disables the NIC
Auto-Negotiate Enables or disables Auto-Negotiation of the LAN Speed.
NOTE: This option is available only on systems with a DRAC
installed.
36 Configuring Your Managed System
Table 2-1. Remote Access Configuration Utility in
x9xx
systems
(continued)
Option Description
LAN Speed Setting This field is read-only when Auto-Negotiate is set to
Enabled.
Sets the LAN Speed Setting to 10 or 100 Mbps
LAN Duplex Setting This field is read-only when Auto-Negotiate is set to
Enabled.
Sets the LAN communication method to Half or Full Duplex.
DNS Configuration Options
DNS Servers from DHCP
on = IP addresses of the DNS Servers are assigned by the DHCP
off = IP addresses of the DNS Servers are set manually
DNS Server 1
This field is read-only when DNS Servers from DHCP is set to on.
Enter the IP Address of DNS Server 1
The following IPv4 rules apply:
DNS Server 2
• IP addresses cannot be between
0-255
• The first octet must be between
143.xxx.xxx.xxx
• The last octet must not be (i.e.
xxx.xxx.xxx.0
This field is read-only when DNS Servers from DHCP is
127.xxx.xxx.xxx
.
)
0
or
or
xxx.xxx.xxx.255
1-223
255
, where
xxx
is
(i.e.
)
set to on.
Enter the IP Address of DNS Server 2
The following IPv4 rules apply:
Register RAC Name
• IP addresses cannot be between
0-255
• The first octet must be between
143.xxx.xxx.xxx
• The last octet must not be (i.e.
xxx.xxx.xxx.0
on = You may enter the Current DNS RAC Name.
127.xxx.xxx.xxx
.
)
0
or
or
xxx.xxx.xxx.255
1-223
255
, where
xxx
is
(i.e.
)
Configuring Your Managed System 37
Table 2-1. Remote Access Configuration Utility in
Option Description
Register RAC Name
Domain Name from DHCP
Domain Name
Virtual Media Configuration
Virtual Media
Virtual Flash
LCD Configuration Configures the virtual Keyboard Video Mouse (vKVM)
LCD User Defined String
LCD System Power Units
LCD Ambient Temp Units
LCD Error Display
LCD Front Panel Access
LCD Remote KVM Indication
LAN User Configuration
This field is read-only when Register RAC Name is set to off.
Enter the Current DNS RAC Name using 1-32 alpha­numerics, spaces, and symbols. Press <Enter> to save the value. Press <Esc> to exit the field without saving.
Turns the domain name on or off.
This field is read-only when DNS Servers from DHCP is set to on.
Enter the Domain Name using 1-64 alpha-numerics, spaces, and symbols. Press <Enter> to save the value. Press <Esc> to exit the field without saving.
NOTE: This option is available only on systems with a DRAC
installed.
Attaches or detaches a virtual media drive.
Enables or disables virtual flash memory.
session status on LCD and the access level to the LCD.
Sets the line of user-defined text on the system LCD.
Sets the unit for the system power.
Sets the unit for the ambient temperature.
Sets the error display field.
Allows you to either View, or View and Modify, or Lock the data on the LCD.
Enables or disables the vKVM session status on the LCD.
Enables setting the user name, user password, user privilege, and enables user access for user ID=2.
x9xx
systems
(continued)
38 Configuring Your Managed System
Table 2-1. Remote Access Configuration Utility in
Option Description
Account Access
Account Privilege
Account User Name
Enter Password
Confirm Password
Reset To Default
System Event Log Menu
Total System Event Log Entries
View System Event Log
Clear System Event Log
Enables or disables account privileges.
Sets the account to:
Admin, User, Operator, or No Access
Sets the account user name.
Enter the password for this Account User. You must enter at least one non-null character.
Confirm the password you entered.
Clears the BMC settings and resets the BMC setting to the defaults.
CAUTION: Resetting to factory defaults will restore
remote non-volatile settings.
Enables viewing and clearing the System Event Log (SEL). A popup box will indicate that the SEL is being read.
Displays the number of records in the SEL.
Displays a record in the SEL, starting with the most recent record. Enter a record number to view, using the Advance to Entry field. Use the Right and Left arrow keys to scroll up and down the SEL.
Erases all records in the SEL.
x9xx
systems
(continued)
NOTE: If the first integrated network interface controller (NIC 1) is used in an Ether
Channel team or link aggregation team, the BMC management traffic will not
function on PowerEdge x8xx systems. The NIC teaming option is supported on PowerEdge x9xx, xx0x, and xx1x systems. For more information about network
teaming, see the documentation for the network interface controller.
Configuring Your Managed System 39

Configuring Your BMC Using the Deployment Toolkit Utility

The Dell OpenManage Deployment Toolkit SYSCFG utility includes a set of Microsoft Windows PE and Linux-based utilities for configuring and deploying Dell systems. The Deployment ToolKit (DTK) SYSCFG utility is specifically designed to address all necessary BMC configuration tasks using a powerful and comprehensive command-line interface. This utility runs on PowerEdge 1435SC and all supported PowerEdge x7xx, x8xx, x9xx, xx0x, and xx1x systems.
To use the BMC Management Utility, configure your managed system with the SYSCFG utility by performing the following tasks:
Obtain the latest version of DTK from
support.dell.com
Create a BMC configuration CD containing a bootable image, and the SYSCFG utility.
•Configure BMC Users.
Configure BMC SOL access.
Configure BMC IPMI serial access.
.
Installation and Setup for Microsoft Windows PE Operating Systems
NOTE: See the Deployment Toolkit User’ s Guide for additional information about
installing and using the utilities, and the Deployment Toolkit Command Line Interface Reference Guide for a complete list of valid options, suboptions, and
arguments for using the SYSCFG.EXE to configure and manage your BMC.
The DTK components are provided as a self-extracting zip file on the Dell Support website at support.dell.com. The self-extracting file can be opened on any system running a Microsoft Windows operating system, or it can be extracted at the Windows Command Prompt (cmd.exe) using the PKUNZIP.EXE utility (not supplied with the Deployment Toolkit). By default, the dtk-2.X-winpe-AXX.exe files are extracted to the root directory of your local hard drive, for example, C:\. This location can be changed by giving a different path when extracting the file. Perform the following steps to extract the DTK components to a workstation running Windows:
the Dell Support website at
40 Configuring Your Managed System
1
Download the DTK file website at
support.dell.com
dtk-2.X-winpe-AXX
.exe
from the Dell Support
and save it on a system running a supported
Windows operating system.
2
After the zip file downloads, double-click the file.
3
Click OK.
4
Click
Unzip
.
By default, the DTK files are unzipped to located in the located in the
C:\Dell\Toolkit\Tools C:\Dell\drivers
folder.
C:
\. The
SYSCFG.EXE
directory. Dell-provided drivers are
Creating a Bootable Windows PE 2005 ISO Image
NOTE: See "Creating a Bootable Windows PE 2.0 ISO Image" on page 43 for
information on creating a bootable CD for Windows PE 2.0.
Integration of DTK Directory Structure in the Windows PE Build
This task involves a five-step process:
1
Integrating DTK tools and scripts: Copy the folder unzipped from the Dell-supplied zip file to
DellWinPEBuild,
the Dell-supplied file directly into the Windows PE build.
2
Installing necessary drivers into Windows PE: Execute
\Dell\Drivers\DRIVERINST.BAT
•Path to
DellWinPEBuild
with two required arguments:
Path where the Dell-provided drivers are located. These drivers can be found in the DTK zip file under the
3
Adding support for mass storage drivers into Windows PE:
\Dell\drivers
\Dell
folder.
that you
utility is
or extract
NOTE: You must implement this step to ensure mass storage drivers are
installed into Windows PE.
In the
winpeoem.sif
file (available under
I386\SYSTEM32
in your Windows PE directory), edit the following text to remove the semicolons from the names for the Dell
Oem Driver Params
-m
ass storage drivers:
section and append the directory
OemDriverRoot="" OemDriverDirs=MRAID, PERC4IM, PERC5, SAS5
Configuring Your Managed System 41
NOTE: For your reference, a sample winpeoem.sif file is available under
\Dell\Toolkit\template\Configs.
4
Starting required services: The started for RAID to function; the
mr2kserv
racsvc
service should be installed and
service should be installed and started for RACADM to function. For details on how to start the required services, see the sample
\Dell\Toolkit\template\Configs
NOTE: When booting the target system, ensure that the RAC and the
mr2kserv services are running.
5
Extracting the following files from your Windows Server 2003 product CD to
\Dell\Toolkit\Tools
winbom.ini
:
file under
.
•rpcns4.dll
•rpcrt4.dll
rpcss.dll
NOTE: The directory name should not have any spaces.
You can now customize the Windows PE according to your requirements.
Creating a Bootable CD
Use the following steps to create bootable media that can be used to configure the BMC on a managed system:
1
Create a directory,
2
Insert the Windows OEM Preinstallation Kit (OPK) CD into your CD
WinPE_OPKTools
, on your hard drive.
drive.
3
Copy all CD files from the Windows PE directory to the
WinPE_OPKTools
4
Copy
factory.exe
the
WinPE_OPKTools
5
Remove the CD from the CD drive.
6
Create and name a directory on your development system hard drive.
directory.
and
netcfg.exe
directory.
from the
CD drive
\tools\x86 directory to
This is where the ISO file is stored.
7
Navigate to the
8
Run the following command:
WinPE_OPKTools
directory through a command prompt.
OSCDIMG -bETFSBOOT.COM -n <DELLWINPEBUILD>
42 Configuring Your Managed System
ETFSBOOT.COM is part of the OPK tools and makes the Windows PE CD bootable. The following command line creates a bootable ISO image called Dellx86winpe.iso:
C:\WINPE_OPKTOOLS\OSCDIMG -bETFSBOOT.com -n c:\DELLWINPEBUILD
C:\FINALBUILD\Dellx86winpe.iso
9
Copy the SYSCFG.EXE utility to the root of the directory.
10
After you create an ISO image, you can use any CD-burning software to burn the image onto a CD.
You are now ready to use your bootable CD to configure the BMC on a managed system. See the
Deployment Toolkit User’s Guide
for additional
information.
Creating a Bootable Windows PE 2.0 ISO Image
If you are using Windows PE 2.0, download Installation Kit (WAIK) from the Microsoft website. By default, WAIK is copied to the
Integration of DTK Directory Structure in Windows PE Build
C:\Program Files\Windows AIK
DTK provides a script, VPE_driverinst.bat, to pre-install the Dell drivers into a base Windows PE 2.0 image offline. Use the following steps to execute this script:
1
Open a command prompt on your system and change the directory to the location of VPE_driverinst.bat. For example:
cd C:\Dell\Drivers\winpe2.x
Windows Administrative
directory.
2
Execute VPE_driverinst.bat with two required arguments
<WINPEPATH>
and
<DTKPATH>
. For example:
VPE_driverinst.bat <WINPEPATH> <DTKPATH>
Where
<WINPEPATH>
structure for Windows PE 2.0 and
i s t h e d e st in a ti o n p a th to c re a te t he d ir e ct o ry
<DTKPATH>
is the path to Dell
drivers in the extracted DTK toolkit. For example:
VPE_driverinst.bat C:\vistaPE_x86 C:\DELL\DRIVERS
Configuring Your Managed System 43
NOTE: <WINPEPATH> is passed as the destination to the WAIK command
copype.cmd. The destination folder C:\vistaPE_x86 is created as part of the
process, and should not already exist.
Creating a Bootable CD
Use the following steps to create bootable media:
1
Click
Start
2
, navigate to
Click
Windows PE Tools Command Prompt
All ProgramsMicrosoft Windows AIK
to open a command prompt
window.
3
Run the following command:
oscdimg -n -bc:\vistaPE_x86\etfsboot.com c:\vistaPE_x86\ISO c:\vistaPE_x86\WinPE2.0.iso
This command creates a CD bootable ISO image called WinPE2.0.iso.
4
You can use any CD burning software to burn the image onto a CD.
You are now ready to use your bootable CD to configure the BMC on a managed system. See the
Deployment Toolkit User’s Guide
for additional
information.
Installation and Setup for Linux Operating Systems
NOTE: See the Deployment Toolkit User’ s Guide for additional information about
installing and using the utilities, and the Deployment Toolkit Command Line Interface Reference Guide for a complete list of all valid options, suboptions, and
arguments for using the SYSCFG utility to configure and manage your BMC.
1
Obtain the ISO image of embedded Linux available on the Dell Support website at
2
Burn the ISO image using any commonly available CD burning software.
support.dell.com
.
.
NOTE: When you create a bootable CD, this image is supplied to the CD burning
software along with the complete deployment directory structure, which includes all necessary supporting files to perform the deployment.
3
The CD burning software creates an image of the self-bootable ISO image and the deployment files on the CD.
4
Extract the contents of the ISO image to a folder on your hard drive.
5
Copy your custom scripts into the folder you created in step 4.
44 Configuring Your Managed System
NOTE: Your scripts should also take care of copying miscellaneous items to
unlock the CD, so that the CD can be mounted and ejected as required by the operating system’s installation process.
6
In
/mnt/cdrom/isolinux.cfg
, the cd install section points to your
customized start-up script.
NOTE: The scripts that you copy into the CD will be copied to and run from the
RAM disk. This task is done to ensure the CD is not locked. Ensure that your sample scripts have valid path names.
7
Copy the directory structure created in your work station, into the root folder that you created in "step 4".
8
This folder contains the DTK CD files necessary for operating system installation, and files required for replication.
9
Use the
isolinux
utility to burn the contents of the folder you created in
"step 7" to a CD and make it bootable.
10
Your ISO image is ready for booting.
Basic configuration
Before you can use the BMC Management Utility to remotely manage the BMC on a managed system, you must perform some basic configuration tasks. The Deployment Toolkit SYSCFG utility provides a powerful command-line interface for performing the following configuration tasks:
Configuring BMC users for the managed system
Configuring the BMC IP address for IPMI LAN access and SOL access for the managed system
Configuring the BMC serial channel for IPMI serial access for the managed system
NOTE: See the Deployment Toolkit User’s Guide for additional information about
installing and using the Deployment Toolkit utilities, and the Command Line Interface Reference Guide for a complete list of valid options, suboptions, and
arguments for using the SYSCFG utility to configure and manage your BMC.
Configuring New BMC Users
The BMC is configured by default with user ID 2 set to username: root and password: calvin. It is highly recommended that you change the user name and password when deploying your system.
Configuring Your Managed System 45
1
Insert the bootable BMC configuration diskette or CD into the appropriate drive of the system to be deployed and reboot the system.
2
To create a new user, at the command prompt, type:
syscfg username --userid=X --name=name
where X is a number between 2–10 and
name
is an ASCII string of 16 or
fewer characters.
Press <Enter> to execute the command line options.
3
To enable the new user ID, at the command prompt, type:
syscfg useraction --userid=X --action=enable
Press <Enter> to execute the command line options.
4
To set the password for a BMC user, at the command prompt, type:
syscfg passwordaction --action=setpassword --userid=X -
-password=password
where
password
PowerEdge
CAUTION: A password must be set for each BMC user. The BMC firmware does
not allow access to users with null user names or passwords.
is an ASCII string of 16 or fewer characters for both
x8xx
and
x9xx
systems.
Press <Enter> to execute the command-line options.
5
To configure BMC user privilege, at the command prompt, type:
syscfg lanuseraccess --usrprivlmt=bmcuserprivilege where bmcuserprivilege=user, operator, administrator, noaccess
Press <Enter> to execute the command-line options.
Configuring the BMC IP Address
1
Insert the Deployment Toolkit CD into the appropriate drive of the system to be deployed and reboot the system.
2
To configure the BMC IP address source for the LAN channel to DHCP, at the command prompt, type:
syscfg lcp --ipaddrsrc=dhcp
Press <Enter> to execute the command line options.
46 Configuring Your Managed System
For a complete list of valid options, suboptions, and arguments for configuring the BMC LAN channel see the
Line Interface Reference Guide
3
To configure the BMC IP address source for the LAN channel to a static
.
Deployment Toolkit Command
IP address, at the command prompt, type:
syscfg lcp --ipaddrsrc=static --ipaddress= XXX.XXX.XXX.XX
--subnetmask=XXX.XXX.XXX.X --gateway= XXX.XXX.XXX.X
Press <Enter> to execute the command line options.
For a complete list of valid options, suboptions, and arguments for configuring the BMC LAN channel see the
Line Interface Reference Guide
Configuring the BMC Serial Channel Access
1
Insert the bootable diskette or CD into the appropriate drive of the system
.
Deployment Toolkit Command
to be deployed, and reboot the system.
2
To configure the serial port for BMC, at the command prompt, type:
syscfg scp --connectionmode=basic -­msgcommbitrate=XXXXX
where
XXXXX
is the baud rate in bps.
Press <Enter> to execute the command line options.
3
To configure the terminal mode for BMC, at the command prompt, type:
syscfg scp --connectionmode=terminal -­msgcommbitrate=XXXXX
where
XXXXX
is the baud rate in bps.
Press <Enter> to execute the command line options.
For a complete list of valid options, suboptions, and arguments for configuring the BMC serial channel, see the
Line Interface Reference Guide
.
Configuring Your Managed System 47
Deployment Toolkit Command

Configuring Your BMC Using Server Administrator

You can also configure the BMC options using Server Administrator Version 5.3 or later, which is a one-to-one systems management software program that must be installed on the managed system. Once installed, you can remotely access Server Administrator from a management station with a supported browser to perform BMC configuration tasks. See the Server Administrator User’s Guide for more information about installing and using Server Administrator.
You can configure the BMC settings from either the Server Administrator home page or from its command line interface. Users must have Administrator privileges to access the BMC settings. Users logged in with User or Power User group privileges can view the BMC information but cannot change the settings.
See the Dell OpenManage Server Administrator Command Line Interface User's Guide for information about configuring the BMC from the command line.
When using Server Administrator, you can click Help on the global navigation bar for more detailed information about the specific window you are viewing. Server Administrator help is available for all windows accessible to the user based on user privilege level and the specific hardware and software groups that Server Administrator discovers on the managed system.
The Server Administrator Instrumentation Service allows you to manage BMC features, such as, general BMC information, configuration of the LAN and serial port, BMC users, and BIOS setup. To use Server Administrator to configure the BMC on a managed system, perform the following steps:
NOTE: You must be logged in with Admin privileges to configure the BMC settings.
1
Log in to the Server Administrator home page for the target system.
2
Click the
3
Click the
4
Click the
5
The
6
Click the
Under the Serial Over LAN.
48 Configuring Your Managed System
System
object.
Main System Chassis
Remote Access
BMC Information
Configuration
Configuration
object.
object.
window is displayed.
tab.
tab, you can configure LAN, Serial Port, and
7
Click the
Under the
CAUTION: A password must be set for each BMC user. The BMC firmware does
not allow access to users with null user names or passwords.
Configuring BIOS in Server Administrator
Users
tab.
Users
tab, you can modify the BMC user configuration.
To configure BIOS in Server Administrator, complete the following steps:
1
Click the
2
Click the
3
Click the
4
Click the
In the
communication
System
object.
Main System Chassis
BIOS
object.
Setup
tab.
Setup
tab, you can configure
parameters.
object.
Console Redirection
and
Serial Port
Using Dell Remote Access Controller 5
The Dell Remote Access Controller (DRAC) 5 provides a Web-based interface and RACADM (a command-line interface) that enables you to configure the DRAC 5 properties and users, perform remote management tasks, and troubleshoot a remote (managed) system for problems.
Configuring the Network and IPMI LAN Settings
NOTE: You must have Configure DRAC 5 permission to do the following steps.
NOTE: Most DHCP servers require a server to store a client identifier token in its
reservations table. The client (DRAC 5, for example) must provide this token during DHCP negotiation. For RACs, the DRAC 5 supplies the client identifier option using a one-byte interface number (0) followed by a six-byte MAC address.
NOTE: If your managed system DRAC is configured in Shared or Shared with Failover
mode and the DRAC is connected to a switch with Spanning Tree Protocol (STP) enabled, network clients will experience a 20- to 30-second delay in connectivity when the management station’s LOM link state changes during the STP convergence.
1
Access the DRAC 5 Web-based interface. See the
Controller 5 User’s Guide
2
Click
Remote Access
3
Click the
Configuration
for more information.
in the
System
tree.
tab and then click
Configuring Your Managed System 49
Dell Remote Access
Network
.
4
Configure the DRAC 5 NIC settings in the
Network Configuration
page.
Table 2-1 describes the Network Settings and IPMI Settings on the
Network Configuration
5
Click
Apply Changes
6
Click the appropriate
Adding and Configuring DRAC 5 Users
page.
when completed.
Network Configuration
page button to continue.
Create unique users with specific administrative permissions (or role-based authority) to manage your system with the DRAC 5 and maintain system security. For additional security, you can also configure alerts that are e-mailed to specific users when a specific system event occurs.
NOTE: You must have Configure DRAC 5 permission to do the following steps.
1
Expand the System tree and click
2
Click the
Configuration
tab and then click
Remote Access
Users
.
. The
Users
page appears, which includes each user’s State, RAC Privilege, IPMI LAN Privilege, and IPMI Serial Privilege.
3
Click a user ID number in the User ID column.
4
Configure the user’s properties and privileges in the
User Configuration
page.
5
Click
Apply Changes
6
Click the appropriate
See the
Dell Remote Access Controller 5 User’s Guide
when completed.
User Configuration
page button to continue.
for more information on the IPMI user privileges, DRAC group permissions, and the DRAC user privilege settings.
50 Configuring Your Managed System
3

Using the BMC Management Utility

The BMC Management Utility is a collection of software applications that enable remote management and configuration of Dell systems equipped with a BMC. The BMC Management Utility includes the following components:
Command Line Interface (IPMI Shell and IPMItool)
Both IPMI Shell and IPMItool are scriptable console application programs used for the control and management of remote systems using the IPMI version 1.5 and later protocol. IPMI Shell supports both serial access and LAN access to the BMC. IPMItool supports only LAN access to the BMC.
The IPMI Shell can be used either in the generic CLI mode or the interactive mode. The interactive mode allows for a dedicated connection to a server and availability of all commands from the operating system CLI. Using the IPMI Shell in this mode improves usability and reduces time and traffic required for connecting and authenticating. The IPMItool can only be used in the CLI mode.
Both IPMI Shell and IPMItool allow administration of one or more managed systems from a command line shell, rather than a graphical user interface (GUI). Use the IPMI Shell or IPMItool to perform the following tasks:
System power management – System identifier control – Access to the event log – Access to the system sensors – Enable Serial-over-LAN for a remote managed system
Using the BMC Management Utility 51
Serial-Over-LAN Proxy (SOL Proxy)
The SOL Proxy is a telnet daemon that allows LAN-based administration of remote systems using the Serial Over LAN (SOL) and IPMI protocols. Any standard telnet client application, such as HyperTerminal on Microsoft Windows or telnet on Linux, can be used to access the daemon's features. SOL can be used either in the menu mode or command mode. The SOL protocol coupled with the remote system's BIOS console redirection allows administrators to remotely view and change a managed system’s BIOS settings over a LAN. The Linux serial console and Microsoft's EMS/SAC interfaces can also be accessed over a LAN using SOL.
CAUTION: All versions of the Microsoft Windows operating system include
Hilgraeve's HyperTerminal terminal emulation software. However, the included version does not provide many functions required during console redirection. Instead, you can use any terminal emulation software that supports VT100 or ANSI emulation mode. One example of a full VT100 or ANSI terminal emulator that supports console redirection on your system is Hilgraeve's HyperTerminal Private Edition 6.1 or later.
NOTE: See your system’s User’s Guide for more information about console
redirection, including hardware and software requirements and instructions for configuring host and client systems to use console redirection.
NOTE: HyperTerminal and telnet settings must be consistent with the settings on
the managed system. For example, the baud rates and terminal modes should match.
NOTE: The Windows "telnet" command that is run from a MS-DOS prompt supports
ANSI terminal emulation, and the BIOS needs to be set for ANSI emulation to display all the screens correctly.
NOTE: In future releases, IPMItool will replace IPMI Shell (IPMISH) and SOL Proxy
utilities.

Installing the BMC Management Utility

The BMC Management Utility is installed on a management station to remotely connect to the managed system’s BMC. See Figure 3-1.
52 Using the BMC Management Utility
Installation Prerequisites
Before using the BMC Management Utility, you must perform at least the basic BIOS and BMC configuration tasks described in "Configuring Your Managed System" on page 25.
In addition, to access the BMC using the IPMI serial feature, you must have a working connection between the management station and the correct serial I/O port of the managed system’s BMC using a null modem cable.
Figure 3-1. Installing on a Management Station

Installation Procedures

The following installation procedures provide step-by-step instructions for installing and uninstalling the BMC Management Utility for each supported operating system:
Installing/uninstalling on systems running supported Windows operating systems
Installing/uninstalling on systems running supported Linux operating systems
Using the BMC Management Utility 53
Installing on Systems Running Supported Windows Operating Systems
To install the BMC Management Utility on a management station running the Windows operating system, perform the following steps:
1
Log in with administrator privileges to the system where you want to install the systems management software components.
2
Exit any open application programs and disable any virus-scanning software.
3
Insert the your system's DVD drive.
If the DVD does not automatically start the setup program, click the button, click drive letter of your DVD drive).
The
4
Click
The
Station
5
Click
A software license agreement appears.
6
Select
The
7
Select
The
Dell Systems Management Tools and Documentation
Run
, and then type
Dell OpenManage Management Station Installation
Install, Modify, Repair or Remove Management Station
Welcome to Install Wizard for Dell OpenManage Management
screen appears.
Next
.
I accept the terms in the license agreement,
Setup Type
Custom Setup
Custom Setup
screen appears.
and click
screen appears.
x:\windows\setup.exe
Next
.
if you agree.
DVD into
(where x is the
screen appears.
.
Start
8
From the drop-down menu, which appears on the left side of BMC Console, select
local hard drive
To accept the default directory path, click and navigate to the directory where you want to install your software, and then click
The
Ready to Install the Program
54 Using the BMC Management Utility
This feature, and all subfeatures will be installed on the
.
Next
. Otherwise, click
Next
.
screen appears.
Browse
9
Ensure that all information is correct and click
The
Installing Dell OpenManage Management Station
and displays the status of the installation.
10
When installation is complete, the appears. Click
NOTE: Enable the virus scanning software after installation.
See the Dell OpenManage Installation and Security User’s Guide for additional information about installing the BMC Management Utility on a management station.
By default, the installation program copies the files to the following directory: C:\Program Files\Dell\SysMgt\bmc.
The SOL Proxy service does not auto-start after installation. To start the SOL Proxy service after installation, you can reboot the system (SOL Proxy automatically starts on a reboot). To restart the SOL Proxy service on Windows systems, complete the following steps:
1
Right-click
Management
2
Click
Services and Applications
are displayed to the right.
3
Locate start the service.
Finish
.
My Computer
window is displayed.
DSM_BMU_SOLProxy
and click
Install Wizard Completed
Manage.
and then click
in the list of services and right-click to
Install
The
Computer
Services.
.
screen appears
screen
Available services
Uninstalling on Systems Running Supported Windows Operating Systems
To uninstall the BMC Management Utility, use the Add/Remove Programs utility in the Control Panel.
Using the BMC Management Utility 55
Installing on Systems Running Supported Linux Enterprise Operating Systems
To install the BMC Management Utility on a management station running the Linux operating system:
1
Log in as root to the system where you want to install the management station components.
2
If required, mount the appropriate media supplied by Dell using the command:
mount /mnt/cdrom
3
Install the BMC Management Utility with the following command for SUSE Linux Enterprise server:
rpm -ivh /linux/bmc/osabmcutil9g-SUSE*.rpm
or for Red Hat Enterprise Linux, use the following command:
rpm -ivh /linux/bmc/osabmcutil9g-RHEL*.rpm
By default, the installation program copies the files to the following locations:
/etc/init.d/SOLPROXY.cfg
/etc/SOLPROXY.cfg
/usr/sbin/dsm_bmu_solproxy32d
/usr/sbin/solconfig
/usr/sbin/ipmish
The SOL Proxy will start automatically during system startup. Alternatively, you can go to directory commands to manage the SOL Proxy service:
solproxy status
/etc/init.d
and use the following
dsm_bmu_solproxy32d start
dsm_bmu_solproxy32d stop
solproxy restart
56 Using the BMC Management Utility
Uninstalling on Systems Running Supported Linux Enterprise Operating Systems
To uninstall the BMC Management Utility, perform the following steps:
1
Log in as
2
Enter either of the following commands to remove all the installed packages from SUSE Linux Enterprise Server or Red Hat Enterprise Linux.
rpm -e osabmcutil9g-SUSE*
rpm -e osabmcutil9g-RHEL*
If the BMC Management Utility has been uninstalled, you will receive a success message.
root
.

IPMI Shell

IPMI Shell is a CLI console application and has no GUI. Its commands and options are specified using command line arguments only.
IPMI Shell supports out-of-band (OOB) access (over a LAN or through the serial port) to a single system at a time, however, multiple IPMI Shell sessions can run simultaneously on the same managed system. See Figure 3-2.
IPMI Shell allows a user with user-level BMC privileges to:
Display the current power status.
Display the 16-byte system GUID of the managed system.
Display information from the system’s field replaceable unit (FRU).
Display the BMC firmware information.
Display summary information about the event log.
Display logged events.
Display current status of platform sensors.
Enable or disable SOL.
Using the BMC Management Utility 57
In addition to the operations that can be performed by a user with user-level BMC user privileges, IPMI Shell allows a user with operator-level and administrator-level BMC user privileges to:
Power on, reset, or power cycle a managed system.
Simulate a hard power off on a managed system (forcing the system to turn off without shutting down the operating system).
Clear the system event log (SEL).
Turn the blinking system identification LED on or off.
To facilitate command scripting, upon successful execution, IPMI Shell terminates with an exit code of zero, and will output the execution results in a parsable format. If an error is encountered, the program exits with a non­zero error code and outputs the error in a parsable format. See "BMC Management Utility Error Codes" on page 113 for a complete list of possible BMC Management Utility error codes.
Figure 3-2. IPMI Shell Diagram
58 Using the BMC Management Utility
Using IPMI Shell
To use IPMI Shell, perform the following steps:
On systems running a supported Microsoft Windows operating system:
1
Start a
Command Prompt
2
Locate the directory:
3
Enter IPMI Shell commands (see "IPMI Shell Command Syntax" on page 59) to manage the remote system. See "IPMI Shell Commands" on page 66 for a complete list of valid options, commands, subcommands, and arguments.
On systems running a supported Linux operating system:
1
Start an operating system (OS) shell.
2
Enter IPMI Shell commands (see "IPMI Shell Command Syntax" on page 59) to manage the remote system. See "IPMI Shell Commands" on page 66 for a complete list of valid options, commands, subcommands, and arguments.
NOTE: The IPMI Shell will be located in /usr/sbin.
ipmish.exe
C:\Program Files\Dell\SysMgt\bmc.
window.
file. By default,
ipmish.exe
is located in the
IPMI Shell Command Syntax
The general syntax of IPMI Shell CLI commands is as follows:
ipmish [global-options] … command [; command] …
The general usage for a command is:
command [subcommand] [command option and argument] …
Both global options and command-specific options are always in the following form:
-option argument
For examp l e:
-help
-max 20
-u John
Using the BMC Management Utility 59
Arguments with embedded tabs or spaces must be enclosed in matching double quotation marks ("). For example:
-user "John Smith"
Every command has one default action. The default action is typically, but not always, the equivalent of reading and displaying the current setting or status for the command.
IPMI Shell Global Options
IPMI Shell has the following global options:
Running IPMISH over LAN Option -ip
Synopsis
ipmish -ip bmc_ip_address | bmc_hostname -u username ­p password
[-k KG value] <command>
Description
This option is used to establish a connection to a remote managed system using the LAN channel. The IP port specified in installation (default value is 623) is used unless another port has been configured.
NOTE: This global option cannot be used independently to connect to the BMC.
One or more IPMISH commands must follow the option.
Options
-ip bmc_ip_address | bmc_hostname
Specifies the IP address or hostname of the remote managed system.
-u username
Specifies the BMC username.
-p password
Specifies the BMC user password.
-k KG value
60 Using the BMC Management Utility
Specifies the KG value in Hex format. The IPMI encryption key is a public key used to generate an encryption key for use between firmware and application. It is differentiated from a password, which is not public and is used to access the firmware. The maximum value is 20 ASCII hex pairs with no spaces between the pairs.
NOTE: Even number of hexadecimal characters is valid and odd number of
hexadecimal characters is invalid. For example, 123456AB67 is valid, and 123 is invalid. Enter 00, 0000, and so on to disable encryption.
NOTE: The IPMI encryption key is available only on Dell x9xx,xx0x and xx1x systems.
Running IPMISH over Serial - Option -com
Synopsis
ipmish -com serial_port -baud baud_rate -flow flow_control -u username -p password
The following attributes should be configured for IPMISH over serial to function correctly.
NOTE: These options can be configured in BIOS Setup, as well as using
Dell OpenManage tools. Log on to Server Administrator and navigate to BIOS Setup.
"External Serial Connector" must be configured and set to "Remote Access" for PowerEdge
x9xx, xx0x,
and
xx1x
systems. This option is
available in the "Serial Communication" submenu in BIOS setup.
Disable the "RAC serial Console" if you have a DRAC 5 card installed. Log on to the DRAC GUI, navigate to Serial and deselect the "Enable Serial console" checkbox.
Set "Serial port 1" to "BMC Serial" for PowerEdge
x8xx
systems. This
option is available under the Integrated Devices menu in BIOS Setup.
The Serial communication connection mode for the BMC must be set to "Direct Connect Basic Mode" for all systems. This can be configured using Server Administrator. Log on to Server Administrator and navigate to Serial Port.
Description
This option establishes a connection to a remote managed system using the serial channel.
NOTE: This global option cannot be used independently to connect to the BMC.
One or more IPMISH commands must follow the option.
Using the BMC Management Utility 61
Options
-com serial_port
Specifies the serial port used when establishing an IPMI session to the managed system. For a system running Windows, the management station port can be 1, 2, 3, and so on. For systems running Linux, the management station port can be ttyS0, ttyS1, ttyS2, and so on.
-baud baud_rate
Specifies the communication baud rate over the serial channel. The maximum reliably supported baud rates are:
19200 for PowerEdge x8
57600 for PowerEdge
xx
x9xx
systems
and
xx0x
systems without Dell Remote Access
Controller 5 (DRAC 5)
115200 for PowerEdge
115200 for PowerEdge
NOTE: The baud rate for serial channel should match the baud rate set in the
managed system.
x9xx
xx1x
and
xx0x
systems
systems with DRAC 5
-flow flow_control
Specifies the data flow control method. There are two flow control options:
cts (hardware flow control) and none (no flow control).
-u username
Specifies the BMC username.
-p password
Specifies the BMC user password.
IPMI Help Option -help
Synopsis
ipmish -help [command]
62 Using the BMC Management Utility
Description
This option displays the following information:
A summary page for all commands
A summary of all subcommands for a single command
A detailed description of a command-subcommand combination
Options
-help subcommand
A command list and a capsule description of options are printed if no argument is given. When there is an argument specifying a valid command, the help option displays a detailed description of the command. See Figure 3-3 and Figure 3-4.
Figure 3-3. IPMI Help Option Example 1
Using the BMC Management Utility 63
Figure 3-4. IPMISH Help option Example 2
IPMI Session Option -interactive
Synopsis
ipmish -interactive [-cfg <config_file>]
Description
This option invokes the interactive CLI mode. An IPMISH prompt appears when entering interactive CLI mode. Type quit to exit the IPMISH prompt and return to the CLI prompt.
NOTE: The command prompt responds with an error message in the interactive
mode, if a command is used before establishing an IPMI session with connect.
Options
-interactive
Invokes the interactive CLI mode.
-cfg <config_file>
64 Using the BMC Management Utility
Specifies the configuration file for BMU to start the CLI mode with. If a configuration file is not specified, BMU operates with default configuration settings.
NOTE: The -interactive option must be followed by connect for ipmish
to work.
See "Configuring the SOL Proxy Configuration File" on page 93 for more information on configuration files.
Figure 3-5. IPMISH interactive option
The following line edit functions are supported during the interactive session:
1
Up and Down arrow keys to browse command history.
2
Left and Right arrow keys to move the input cursor.
3
Home and End keys to move the input cursor to the beginning or end of the line.
4
Backspace key to move the input cursor back by one space.
The following line edit functions are supported for the SOL proxy menu mode:
1
Left and Right arrow key to move the input cursor.
2
Home and End keys to move the input cursor to the beginning or end of the line.
3
Backspace key to move the input cursor back by one space.
Using the BMC Management Utility 65
IPMI Shell Commands
Table 3-1 lists IPMI Shell commands with a brief description.
NOTE: The sol, sensor, and connect commands can be used in the IPMI
Shell interactive and non-interactive modes and the quit command can be used only in the interactive mode.
Table 3-1. IPMI Shell Commands
Command Description
identify Controls the identification LED on the front panel.
sysinfo Retrieves and displays managed system information.
power Controls the power state of the managed system.
sel Displays or deletes information from the SEL.
sol Enables Serial-over-LAN for the remote managed system.
sensor Displays current status of platform sensors.
LCD Displays information on and helps configure the LCD panel in
Dell
x9xx, xx0x,
powermonitor Displays information on and helps manage your system’s power.
connect Connects to the BMC of the remote managed system.
help Displays a command list with descriptions and syntax of options.
quit Exits the command prompt.
and
xx1x
systems
.
identify
Synopsis
identify [on [-t seconds] | off]
Description
This command controls the identification LED on the front panel. See Figure 3-6.
66 Using the BMC Management Utility
Subcommands
on
off
Turns the managed system’s front panel LED on or off. If the BMC supports the IPMI extension Chassis Identify On command, then the identify on command turns the LED on indefinitely until the identify off command is used to turn the LED off.
NOTE: Acknowledgement or status check of the command is not displayed on the
command prompt. You should manually check the status on the system.
Options
-t seconds
Specifies how long the LED is on. It should be no longer than 255 seconds.
Default Subcommand
If a subcommand is not specified, this command acts the same as the identify on command.
Figure 3-6. identify Option Example
sysinfo
Synopsis
sysinfo [fru | id]
Description
This command retrieves and displays the system information, including field replaceable unit (FRU) and BMC information for the managed system. See Figure 3-7 and Figure 3-8.
Using the BMC Management Utility 67
Subcommands
fru — Returns FRU related information
id — Returns BMC related information
Default Subcommand
If a subcommand is not specified, this command acts the same as sysinfo id. See Figure 3-7.
Figure 3-7. sysinfo Option Example
Figure 3-8. sysinfo FRU Example
68 Using the BMC Management Utility
power
Synopsis
power status
power off [-force] | on | cycle | reset
Description
This command displays the current power status of the managed system, turns the system on or off, or resets the system. See Figure 3-9.
Subcommands
status
value is
on
off
NOTE: This reboot feature mimics restarting the system using the server's power
button. A graceful shutdown of the server operating system may not be possible when the server software stops responding, or if the local security policy of the operating system does not allow a graceful shutdown. In these cases, specify a forced reboot instead of graceful reboot of Windows.
cycle
reset
— Displays the current power status of the system, the returned
on
or
off
.
— Turns on the managed system.
— Issues a "graceful shutdown" IPMI command.
— Turns off the system, pauses, then turns the system back on.
— Pulses the system reset signal, regardless of the power state.
Options
-force
This option simulates pressing and holding the power button for four or more seconds.
Default Subcommand
If a subcommand is not specified, this command functions the same as power status.
Using the BMC Management Utility 69
Figure 3-9. Power Option Example
sel
Synopsis
sel status
sel get [[-begin index1] [-end index2 | -max count]] | [-last n] [-format <oemlist|legacy>]
sel clear
Description
This command displays the system event log information, displays the contents of the event log, and deletes all the event log records. See Figure 3-10.
Subcommands
status
get
clear
— Displays the total number of system event log records.
— Prints all or part of the event log.
— Deletes all the records in the event log.
70 Using the BMC Management Utility
Options
-begin index1
Specifies the first record to display.
-end index2
Specifies the last record to display.
-max count
Specifies the maximum number of records to display.
If the value of the argument count is bigger than the total number of the records, the last record displayed will be the last one in the event log.
-last n
Specifies the number of records to be displayed, starting from the last record and counting backwards.
Default Subcommand
If a subcommand is not specified, this command acts the same as sel status.
Display Format
System event log records are displayed using either a tabular format (legacy) or a vertical format (oemlist) consistent with the SEL log output found in other Dell OpenManage products. The default is the oemlist format. The column headers for the legacy format are: Ordinal Number, Date, Time, Sensor Number, Sensor Type, and Brief Description. See Figure 3-10 for an example of oemlist and legacy formatted SEL display.
Using the BMC Management Utility 71
Figure 3-10. sel Option Example
SOL
Synopsis
sol[enable |disable]
sol config [-baud baud_rate][-priv privilege_level] [-retry count retry_count] [retry interval retry_interval]
Description
This command allows you to configure sol session parameters of a remote BMC. See Figure 3-11.
NOTE: The command prompt responds with an error message if a command is
used before establishing an IPMI session with connect.
Subcommands
enable
disable
config
— Allows you to enable SOL of connected server.
— Allows you to disable SOL of connected server.
— Allows you to configure SOL baud rate and privilege level.
72 Using the BMC Management Utility
Options
-baud baud_rate
Specifies the communication baud rate over the serial channel, such as 9600 or 19200. It should be in conformity with the SOL baud rate of the managed server.
-priv privilege_level
Specifies minimum privilege levels required to establish an SOL session. Possible values are User, Operator, and Administrator.
-retry count retry_count
Specifies number of times the BMC will retry sending SOL packages if no acknowledgement is received. The maximum and minimum values are 7 and 0, respectively.
-retry interval retry_interval
Specifies the retry time interval that the BMC will wait before resending SOL packets to the remote console. It is specified in 10 ms increments. For example, if you set 100 as the value, the BMC will wait 1000 ms before retrying to send SOL packages to the remote console. If you specify zero as the value, the BMC will retry sending instantly, without any time intervals.
Figure 3-11. IPMISH SOL option
Using the BMC Management Utility 73
sensor
Synopsis
sensor [temp|fan|volt|discrete|numeric][-format <oemlist|legacy>]
Description
This command displays the current status of platform sensors using one of the two possible formats. See Figure 3-12.
OPTIONS
[temp|fan|volt|discrete|numeric]
Specifies the sensor group (temp, volt, fan, discrete, or numeric) for which information is displayed. If you do not specify a sensor group, all sensors for which there is information will be displayed.
-format <oemlist|legacy>
Use different formats to output the sensor data. Default format is oemlist. Legacy format is displayed as below:
Sensor Name | Sensor Type | Sensor # | Status [| Value | Units]
Subcommands
[temp | fan | volt | discrete | numeric]
Specifies the sensor group for which information is displayed. If no sensor group is specified, information is displayed for all groups.
74 Using the BMC Management Utility
Figure 3-12. Sensor option example
connect
Synopsis
connect -ip bmc_ip_address | bmc_hostname [-u username] [-p password] [-k IPMI encryption key value]
connect -com bmc_ip_address | bmc_hostname -u username
-p password
[-k KG value] <command>
Description
This command establishes an IPMI connection with the remote server in the interactive mode to enable the user to perform server management activities. The command remains active until the user quits the command prompt or uses the command again to connect to a different server. See Figure 3-13.
Options
-ip bmc-ip-address|bmc_hostname
Specifies the out-of-band IP address or hostname of the remote managed system.
-u username
Specifies the username to connect to the remote system.
Using the BMC Management Utility 75
-p password
Specifies the password to be used to connect to the remote managed system.
-k IPMI encryption key value
Specifies the KG value in Hex format. The IPMI encryption key is a public key used to generate an encryption key for use between firmware and application. It is differentiated from a password, which is not public and is used to access the firmware. The maximum value is 20 ASCII hex pairs with no spaces between the pairs.
NOTE: Even number of hexadecimal characters is valid and odd number of
hexadecimal characters is invalid. For example, 123456AB67 is valid, and 123 is invalid. Enter 00, 0000, and so on to disable encryption.
Figure 3-13. IPMISH connect option
LCD
Synopsis
LCD info
Description
This command displays the status of the LCD display on a x9xx, xx0x, or xx1x system. You can also configure the LCD display using this command.
Subcommands
info
set other
none
default
— Displays information about the LCD display.
— Sets LCD display to either
none, default, other
to set a string of your choice.
— Turns the LCD display off.
— Sets the default display on the LCD.
. Choose
76 Using the BMC Management Utility
Default Subcommand
If a subcommand is not specified, this command functions the same as LCD info.
powermonitor
Synopsis
powermonitor status
Description
This command displays the current power status of the managed system.
Subcommands
status
— Displays the current power status of the system. The returned values denote energy consumption, peak power (in Watts), and peak amperage.
clear peakpower
clear cumulativepower
Default Subcommand
— Deletes the peak power value.
— Deletes the cumulative power values.
If a subcommand is not specified, this command functions the same as power status.
quit
Synopsis
quit
Description
This command exits the IPMI Shell interactive mode and returns to the command mode.
Using the BMC Management Utility 77
help
Synopsis
help [command]
Description
This command lists commands and capsule descriptions with syntax for each command. See Figure 3-14.
Argument
command
Specifies the command for which detailed description is required.
Figure 3-14. IPMISH help option

SOL Proxy

SOL Proxy is a simple telnet server. It allows a telnet client to interact with the hardware-designated serial port of a remote managed system using the LAN communication channel. See Figure 3-15. With SOL Proxy, administrators can view and change the BIOS settings over a shared LAN. In addition, you can also access your managed system’s BMC using SOL Proxy using the Linux serial console and Microsoft’s EMS/SAC interfaces. SOL Proxy does not support in-band or serial connection to the managed system’s BMC.
78 Using the BMC Management Utility
When BIOS console redirection to serial port is enabled on the remote managed system, any application that uses the BIOS to read from or write to the system console will have its I/O redirected to the designated serial I/O port. When SOL is activated, the BMC firmware reads any data written to the serial port and transmits it to the SOL Proxy as LAN packets. SOL Proxy then forwards the data to the telnet client as TCP/IP packets.
Conversely, any keyboard activity at the telnet client is sent to the BMC by SOL Proxy. BMC then writes the packets to the system serial I/O port.
NOTE: See your system’s User’s Guide for more information about console
redirection, including hardware and software requirements and instructions for configuring host and client systems to use console redirection.
Figure 3-15. SOL Proxy Diagram
The SOL Proxy communication scheme enables you to view and configure the BIOS settings of a managed system, as well as to reset the managed system remotely using a telnet client. SOL Proxy is installed as a daemon service and automatically starts each time the system boots. SOL Proxy can accommodate only one telnet session at a time.
Using the BMC Management Utility 79
You can use a variety of telnet clients to access SOL Proxy features. For exam ple :
In a Windows environment, you can use a Command Prompt window as your console. However, function keys such as <F1> and <F2> will not operate correctly with this client except on systems running Windows Server 2003.
In a Windows environment, you can also use any telnet application that supports VT100 or ANSI emulation mode (such as HyperTerminal) as your console.
CAUTION: All versions of the Microsoft Windows operating system include
Hilgraeve's HyperTerminal terminal emulation software. However, the included version does not provide many functions required during console redirection. Instead, you can use any terminal emulation software that supports VT100 or ANSI emulation mode. One example of a full VT100 or ANSI terminal emulator that supports console redirection on your system is Hilgraeve's HyperTerminal Private Edition 6.1 or later.
CAUTION: SOL Proxy supports only local user login and not Active Directory
login. Authentication errors will result in case of Active Directory logins.
NOTE: When using HyperTerminal, you must deselect the Wrap lines that
exceed terminal width check box to avoid console redirected data that may
appear to be corrupted or garbled. To deselect this feature, click File Properties Settings ASCII Setup Wrap lines that exceed terminal width.
NOTE: See your system’s User’s Guide for more information about console
redirection, including hardware and software requirements and instructions for configuring host and client systems to use console redirection.
In a Linux environment, you can use a shell such as
csh
or
ksh
as your console, or you can use any telnet application supporting VT100 or ANSI emulation mode.
NOTE: Telnet settings must be consistent with the settings on the managed
system. For example, the baud rates and terminal modes should match.
You can also send the terminal break function while in console redirection. The use of this functionality requires that the specific terminal program in use has the ability to send the break function. For example, you can send the break signal through the Linux telnet modules by typing:
Ctrl+]send brk<Enter>
80 Using the BMC Management Utility
The Linux SysRq function is one example of an advanced debugging feature that is enabled by use of the break function. See the "BIOS Configuration" on page 25 on how to use this feature. See the "Serial Console redirection With SOL Proxy" on page 133 for more information on the SysRq feature.
To enable BIOS console redirection for use with SOLProxy:
•Configure the
Redirection via COM2
the
Serial Communication
COM2
Console redirection
for Dell
attribute to
x9xx
and
attribute to
On with Console Redirection via
. This option is available under the
On with Console
xx0x
. For
xx1x systems, configure
Serial Communication
submenu in BIOS setup.
•Configure the PowerEdge
Redirection
option is available under the
Console Redirection
x8xx
systems. This option is available under the
menu in
BIOS Setup
attribute to
. Set
Serial Port 1
Integrated Devices
Serial Port1
menu in
to
BMC NIC
for
Console
. This
BIOS Setup
.
Using SOL Proxy
Depending on the console you use, there are different steps for accessing SOL Proxy. Throughout this section, the management station where the SOL Proxy is running is referred to as the SOL Proxy Server.
Initiating the SOL Proxy session using the Windows Command Prompt:
To connect and use SOL Proxy:
1
Open a Command Prompt window on your management station.
2
Enter the IP address of the SOL Proxy server and the port number that you specified in the SOL Proxy installation (the default value is 623). For example:
telnet 192.168.1.24 623
telnet
command in the command-line and provide the
NOTE: The IP address and port number you provide should conform to the
ones defined in the SOL Proxy configuration file. For more details, see "Configuring the SOL Proxy Configuration File" on page 93.
3
If you are prompted for a username, provide the operating system login credentials of the system running the service:
Using the BMC Management Utility 81
DSM_BMU_SOLProxy
.
4
Provide a password when prompted. SOL Proxy will use this combination of operating system username and password to authenticate you on the SOL Proxy Server. The specific authentication scheme will depend on the operating system configuration for the SOL Proxy Server. However, if
localhost
or an IP address of 127.0.0.1 is used, it is assumed that the user has login privileges to the current host, and is not prompted for a username and password.
5
After authentication, a login successful message and the SOL Proxy main menu prompt appear. You are ready to use SOL Proxy. By default, you will be logged in the menu mode. See "SOL Proxy Main Menu" on page 83 for further instructions.
The following line edit functions are supported during the SOLProxy session:
1
Up- and down- arrow keys to browse command history.
2
Left- and right- arrow keys to move the input cursor.
Using a Linux Shell
To connect and use SOL Proxy:
1
Open a Linux shell on your management station.
2
Enter the
telnet
command and provide the IP address of the SOL Proxy Server and the port number you specified in SOL Proxy installation. For example:
telnet 192.168.1.24 623
NOTE: The IP address and port number you provide should conform to the
ones defined in the SOL Proxy configuration file. For more details, see "Configuring the SOL Proxy Configuration File" on page 93.
3
If you are prompted for a username, provide the operating system login credentials of SOL Proxy Server.
4
Provide a password when prompted. SOL Proxy will use this combination of operating system username and password to authenticate you on the SOL Proxy Server. The specific authentication scheme will depend on the operating system configuration for the SOL Proxy Server. However, if
localhost
or an IP address of 127.0.0.1 is used, it is assumed that the user has login privileges to the current host, and is not prompted for a username and password.
82 Using the BMC Management Utility
5
After authentication, a login successful message and the SOL Proxy main menu prompt appear. You are ready to use SOL Proxy. See "SOL Proxy Main Menu" on page 83 for further instructions.
SOL Proxy Main Menu
After the telnet connection with SOL Proxy is successfully established, you are presented with the following choices. See Figure 3-16.
Figure 3-16. SOL Proxy Main Menu Example
The SOL Proxy main menu allows you to change the SOL settings of a remote managed system’s BMC, reboot the remote BMC, or activate console redirection.
When you select menu option 1, Connect to the Remote Server’s BMC, you are prompted for the BMC IP address and BMC login. After you enter the required information and make a successful connection, the internal state SLP is changed to “connected.” If you select menu options 2, 3, or 4, and the application state is not “connected,” you are prompted to connect to a BMC.
Using the BMC Management Utility 83
Menu option 2 allows you to enable, disable, and configure the SOL defaults, including the minimum user privilege level required for activating SOL and the communication baud-rate.
Menu options 3 and 4 allow you to establish a SOL remote console session through the SOL Proxy main menu. Menu option 3 establishes a SOL session without changing the remote system’s state. This option is ideal for connecting to the Microsoft SAC/EMS or the Linux console. Menu option 4 reboots the remote managed system and establishes a SOL session. This option is best suited for performing BIOS setup and system configuration tasks.
To exit an active SOL session, use the <~><.> character sequence. This sequence terminates SOL and returns you to the top-level menu.
Connecting to the Remote Managed System’s BMC
NOTE: While multiple SOL sessions can be active at the same time, only one
console redirection session can be active at any given time for a managed system.
1
Select option 1 in the main menu.
2
Enter the BMC IP address of the remote managed system.
3
Provide the BMC username and password for the BMC on the managed system. The BMC username and password must be assigned and stored in the BMC non-volatile storage. See "Configuring Your Managed System" on page 25 for more information about configuring BMC users. Only one SOL session with one BMC is permitted at one time.
The connection status displays on the main menu. See Figure 3-17.
4
Provide the IPMI encryption key if it was configured in the BMC.
84 Using the BMC Management Utility
Figure 3-17. Connecting to the Remote System’s BMC
Configuring the SOL for the Remote Managed System
Select option 2 in the main menu.
NOTE: You must be connected to the managed system’s BMC before you can
configure the SOL features. If SOL Proxy is not yet connected to the managed system’s BMC, you are prompted for an IP address, a username/password combination, and an IPMI encryption key. The IPMI encryption key value will be ignored if no key was set at the BMC on the target server. See "Connecting to the Remote Managed System’s BMC" on page 84 for more information.
Using the BMC Management Utility 85
The SOL configuration menu appears. According to the current SOL status, the content of the SOL configuration menu varies:
If SOL is already enabled, the current settings are displayed and you are presented with three choices. See Figure 3-18.
Figure 3-18. Configuring the Serial-Over-LAN for the Remote System, Example 1
If SOL is currently disabled, the options shown in Figure 3-19 are displayed. Type
Y
to enable SOL or N to keep SOL disabled. See
Figure 3-19.
86 Using the BMC Management Utility
Figure 3-19. Configuring the Serial-Over-LAN for the Remote System, Example 2
If SOL is enabled, two BMC settings are displayed:
The communication baud-rate between the system serial port and the
BMC
The minimum BMC user privilege level required for activating
console redirection
SOL Proxy displays a list of valid values for each feature, as well as the current value of the feature enclosed in a pair of brackets. Select the number before a value to set it as the new setting, and press <Enter> to confirm your changes. The new SOL settings are then displayed. See Figure 3-20.
Using the BMC Management Utility 87
Figure 3-20. SOL Settings, Example 3
Activating Console Redirection
Select option 3 in the main menu.
NOTE: You must be connected to the managed system’s BMC before you can
configure the SOL features. If SOL Proxy is not yet connected to the managed system’s BMC, you are prompted for an IP address and a username/password combination. See "Connecting to the Remote Managed System’s BMC" on page 84 for more information.
The remote managed system’s text console is redirected to your management station. See Figure 3-21.
NOTE: BIOS Console Redirection must be enabled on the managed system and
correctly configured before SOL can be successfully activated. See "Configuring Your Managed System" on page 25 for more information.
88 Using the BMC Management Utility
Figure 3-21. Console Redirection Example
Rebooting the Managed System and Activating Console Redirection
Select option 4 in the main menu.
NOTE: You must be connected to the managed system’s BMC before you can
configure the SOL features. If SOL Proxy is not yet connected to the managed system’s BMC, you are prompted for an IP address, a username/password combination, and an IPMI encryption key. The IPMI encryption key value will be ignored if no key was set at the BMC on the target server. See "Connecting to the Remote Managed System’s BMC" on page 84 for more information.
The power state of the remote managed system is confirmed. If power is on, you are prompted to decide between a graceful or forceful shutdown.
NOTE: This reboot feature mimics restarting the system using the server's power
button. A graceful shutdown of the server operating system may not be possible when the server software stops responding, or if the local security policy of the operating system does not allow a graceful shutdown. In these cases, specify a forced reboot instead of graceful reboot of Windows.
Next, the power state is monitored until the status changes to on. Console redirection begins, and the remote managed system text console is redirected to your management station. Use the escape character sequence <~><.> to terminate console redirection and return to the top-level menu.
Using the BMC Management Utility 89
While the managed system reboots, you can enter the BIOS system setup program to view or configure BIOS settings. See Figure 3-22.
NOTE: Before activating the console redirection, you must first enable the console
redirection features. See "Configuring Your Managed System" on page 25 for more information.
Figure 3-22. Reboot Example
Getting Help
Select option 5 in the main menu to display detailed descriptions for each option. See Figure 3-23.
90 Using the BMC Management Utility
Figure 3-23. Sample Help Screen
Exit
Select option 6 to end your telnet session and disconnect from SOL Proxy.
Using SOL proxy in command mode
By default, SOL Proxy is installed for use in the menu mode by the system. See "Configuring the SOL Proxy Configuration File" on page 93 for instructions on how to change the default settings to command mode.
Commands in SOL Proxy
SOL Proxy command mode is similar to the IPMI Shell interactive mode. In addition to supporting all commands of the IPMI Shell interactive mode, the SOL Proxy supports the following additional commands.
Using the BMC Management Utility 91
console
Synopsis
console
Description
This command allows users to establish an SOL session with the connected server.
NOTE: BMU responds with an error message if console is used before establishing
an IPMI session with connect.
reboot
Synopsis
reboot[-force]
Description
This command allows you to control power configurations and establish an SOL session in one atomic operation. It is equivalent to executing the menu command of "Reboot and Activate Console Redirection". See Figure 3-24.
Options
-force
This option is used to force the system to shut down. If this option is omitted, the "reboot" command is executed using a graceful shutdown.
Figure 3-24. reboot Option Example
92 Using the BMC Management Utility
Configuring the SOL Proxy Configuration File
Certain parameters, for IPMI Shell and SOL Proxy, must be correctly configured in the SOL Proxy Configuration file, - SOLProxy.cfg, which is located in the default installation BMC directory.
The parameters and their descriptions are as follows:
Comments
Any line starting with a “#” is treated as a comment. For example:
#The file is an example.
IP Address
Specifies the specific IP address used to connect to SOL Proxy. This item defines what kind of connection can be accepted to establish a SOL Proxy telnet session. There are three possible values:
INADDR_ANY
server.
127.0.0.1
IP address
For examp l e:
ip=INADDR_ANY
SOL proxy listens for input on any interface on the
— SOL proxy listens for input on the localhost only.
SOL proxy listens for input on this IP address only.
Port Binding
Specifies the port at which the SOL Proxy listens for incoming connections. By default, the port is set to 623 and can be modified by the user.
This item defines the port when you telnet SOL Proxy. If this item is absent, 623 is set as the default port. For example:
port=623
Session Timeout
Specifies the time in minutes before the SOL Proxy session times out.
If there is no keyboard activity for the specified timeout period, the telnet session and the SOL session will be closed. The timeout value is specified in minutes and can be changed during SOL Proxy installation. For example:
Using the BMC Management Utility 93
session_timeout=30
Power-off Timeout
Specifies the time in seconds before the SOL Proxy gives up polling for the managed system's power status. If the SOL Proxy issues the power off command and the system does not power off within the specified interval, the SOL Proxy returns with a message, indicating that the SOL Proxy was unable to power off the system due to the timeout interval.
NOTE: When Reboot and Activate Console Redirection is selected and power for
the remote managed system is on, a power off IPMI command is issued. The power status is then continually monitored until the power status reports “off.” If power status remains “on” longer than this timeout period, Reboot and Activate Console Redirection reports an error and returns to the top-level menu. This timeout value is specified in seconds and can be changed during SOL Proxy installation.
For example:
power_off_timeout=60
Retry Interval
Specifies the period of time in seconds that the BMC waits before it tries to resend a packet. The retry_interval unit is half a second. Therefore, a value of 2 means that the software waits one second for the BMC to respond before it tries to resend the packet, a value of 4 means that it waits two seconds, and so on. For example:
retry_interval=2
Retry Count
Specifies the maximum number of times that the software tries to resend a packet if it does not receive a response from the BMC. Before each retry, the software waits for the interval specified by the retry_interval parameter. For example:
retry_count=10
User Interface
Specifies the default settings for SOL Proxy startup. The user can edit and set this comment in the command or menu mode. For example:
user_interface=menu
94 Using the BMC Management Utility
Sol Loss Silent
Specifies system behavior when one or more SOL packets are lost. The possible values are 0 and 1. If it is set to 0 or is absent, the system will print an error message on the screen each time an SOL packet is lost. If it is set to 1, the system will not print error messages for loss of SOL packets. For e xa mp le :
sol_loss_silent=0 or 1
Sol Loss Threshold
Specifies number of SOL packets that can be lost before SOL deactivation. The default value is 0, which means that the system will deactivate SOL, if any SOL packets are lost. For example:
sol_loss_silent_threshold=0
Sdr Cache
Specifies whether the system probe information is saved. This information enhances speed of providing sensor and System Event Log (SEL) data. The possible values are on and off. Default value is on. For example:
sdr_cache=on
Sdrcache Path
Specifies path where the system probe information is saved. Default location is the installed BMC directory on your hard drive. For example,
sdrcache_path=<specified path directory>
Max Session
Specifies the maximum number of concurrent SOL sessions possible. This default value is 1; any value less than 1 will be ignored or treated as 1. You cannot set more than 20 sessions. For example:
max_session=2
Logpath
Specifies the path for storing the log files. Two log files, solproxy.log and solproxyipmi.log, are created at the specified path. For example,
logpath=<specified location for log file>
Using the BMC Management Utility 95
debug
Specifies if the debug data will be logged. The default is off.
debug=off

IPMItool

IPMItool is a CLI utility that helps in configuring and managing devices using the IPMI version 1.5 and later protocol. IPMItool supports out-of-band (OOB) access (over a LAN) to a single system at a time. However, multiple IPMItool sessions can run simultaneously on the same managed system.
IPMItool allows a user with user-level BMC privileges to:
Display the current power status.
Display the 16-byte system GUID of the managed system.
Display information from the system’s FRU.
Display the BMC firmware information.
Display summary information about the system event log.
Display logged events.
Display current status of platform sensors.
•Enable or disable SOL.
NOTE: See the IPMItool man page available on the World Wide Web for a
comprehensive list of features.
NOTE: While running ipmitool inband on Linux, if the OpenIPMI driver is not
running by default, it may cause commands to fail. To start the OpenIPMI drivers, use the command driver automatically during boot, use
service ipmi start. To set the system to start the
chkconfig ipmi on.
In addition to the operations that can be performed by a user with user-level BMC user privileges, IPMItool allows a user with operator-level and administrator-level BMC user privileges to:
Power on, reset, or power cycle a managed system.
Simulate a hard power off on a managed system (forcing the system to turn off without shutting down the operating system).
Clear the system event log (SEL).
Turn the blinking system identification LED on or off.
96 Using the BMC Management Utility
To facilitate command scripting, upon successful execution, IPMItool terminates with an exit code of zero, and will output the execution results in a parsable format. If an error is encountered, the program exits with a non­zero error code and outputs the error in a parsable format. See "BMC Management Utility Error Codes" on page 113 for a complete list of possible BMC Management Utility error codes.
The complete list of commands listed under delloem in Table 3-2 are supported by the IPMItool.
delloem
The delloem commands provide information on Dell-specific features.
Table 3-2 lists the delloem subcommands with a brief description.
NOTE: The vFlash info Card command can be used only for in-band access.
Table 3-2. delloem Subcommands
Command Description
lcd
powermonitor
sysinfo
sel
sensor
mac
lan
windbg
vFlash info
Displays information on and helps configure the LCD
Dell
panel in
Displays power tracking statistics information.
Displays information about your system.
Displays the system event log information.
Displays information on and helps manage your system’s sensors.
Displays information about the system NICs.
Displays the NIC selection mode information.
Controls the debugging sessions.
Displays the vFlash SD card properties.
x9xx, xx0x,
and
xx1x
systems.
Card
Options for LCD
lcd set {mode}|{lcdquallifier}|{errordisplay}
lcd set mode
: Allows you to set the LCD mode and user defined
string.
Using the BMC Management Utility 97
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd set mode {none}|{modelname}|{ipv4address}|{macaddress}|{sy stemname}|{servicetag}|{ipv6address}|{ambienttemp }|{systemwatt}|{userdefined}|<text>{assettag}
NOTE: The kgkey (-k option in lanplus) is a string of 20 ASCII characters.
This feature is enhanced for xx1x systems to support the kgkey in hex. The
option is
work, ensure that this kgkey is the same as what is set on the xx1x system.
Except for the default value, the 40 character hex kgkey should start with a non–zero value. If you enter a value less than 40 characters or any non-hex values, an error message displays.
lcd set lcdquallifier
–x followed by a 40 character hex value. For the lanplus interface to
: Allows you to set the unit for the
system Watt and ambient temperature modes.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd set lcdquallifier {watt}|{btuphr}|{celsius}|{fahrenheit}
lcd set errordisplay
: Allows you to set the error display.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd set errordisplay {sel}|{simple}
info
: Displays information about the LCD display.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd info
lcd set vkvm:
To set the vKVM status,
Active
or
Inactive
Command Syntax:
98 Using the BMC Management Utility
.
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd set vkvm {active}|{inactive}
lcd set frontpanelaccess
: Sets the LCD mode to view and
modify, view only, or disabled.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd set frontpanelaccess{viewandmodify}|{viewonly}| {disabled}
lcd status
: To view the vKVM status (Active or Inactive) and to view the front panel access mode (View and Modify, View Only, or Disabled) on the LCD.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem lcd status
Options for powermonitor
status
: Displays the current power status of the system. The returned values denote energy consumption, peak power (in Watts), and peak amperage (in Amperes).
clear peakpower:
clear cumulativepower
powersupplyrating:
Resets the peak power value.
: Resets the cumulative power values.
Gets the power rating for all the power supplies
attached in rated Watts.
Command Syntax:
ipmitool -I lanplus -H <ip-address> -U <user> -P <password> -k <kgkey> delloem powermonitor powersupplyrating
powerconsumption
: Displays the warning threshold, failure threshold, system instantaneous headroom, and system peak headroom in Watts or BTU/hr and the instantaneous current consumption in Amperes.
Command Syntax:
Using the BMC Management Utility 99
ipmitool -I lanplus -H <ip-address> -U <user> -P <password> -k <kgkey> delloem powermonitor powerconsumption <watt|btuphr>
The system peak headroom is applicable on systems with PMBus support. The peak headroom is reported in BTU/hr or Watt. Peak Headroom (in Watts) = Input Wattage to Power Supply
Peak Power drawn by the system. For redundant power supplies, the minimum input wattage between the two power supplies is taken. This value is not displayed in modular systems. The system instantaneous headroom is applicable on systems with PMBus support. The instantaneous headroom is reported in BTU/hr or Watt. Instantaneous Headroom (in Watts) = Input Wattage to the Power Supply
Instantaneous Power drawn by the system. For redundant power supplies, the minimum input wattage between the two power supplies is taken. This value is not displayed in modular systems.
getpowerbudget
: Displays the maximum power, minimum power, and the power budget cap either in BTU/hr or Watt and is supported on
xx1x
systems supporting PMBus.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem powermonitor getpowerbudget <watt|btuphr>
setpowerbudget
BTU/hr, or Watt, or in percentage and is supported on
: Allows you to set the power budget cap either in
xx1x
systems
supporting PMBus.
Command Syntax:
ipmitool -I lanplus -H <ipaddress> -U <user> -P <password> -k <kgkey> delloem powermonitor setpowerbudget <val><watt|btuphr|percent>
NOTE: <val> should be a positive integer.
enablepowercap
disablepowercap
powerconsumptionhistory
: Enables set power cap.
: Disables set power cap.
power consumption history in Watts or BTU/hr for the last minute, last hour, last day, and the last week.
100 Using the BMC Management Utility
: Allows you to get the average and peak