Integrated Dell™ Remote
Access Controller 6 (iDRAC6)
Enterprise for Blade Servers
Version 2.2
User Guide
Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
__________________
Information in this document is subject to change without notice.
© 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell , the DELL logo, OpenManage , and Powe rE dg e are trademarks of Dell Inc.;
Microsoft, Windows, Windows Server, Internet Explorer, MS-DOS, Windows Vista, ActiveX, and
Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States
and/or other countries; Red Hat and Red Hat Enterprise Linux are registered trademarks of Red Hat, Inc.
in the United States and other countries; Novell and SUSE are registered trademarks of Novell, Inc. in the
United States and other countries; Intel is a registered trademark of Intel Corporation in the U.S. and other
countries; UNIX is a registered trademark of The Open Group in the United States and other countries;
Thawte is a registered trademark of Thawte and its affiliated and subsidiaries in the United States and
in foreign countries; Ve ri S i g n is a registered trademark of VeriSign, Inc. and its subsidiaries in the
United States and in foreign countries; Sun and Java are trademarks or registered trademarks of
Sun Microsystems, Inc. or its subsidiaries in the United States and other countries.
Copyright 1998-2009 The OpenLDAP Foundation. All rights reserved. Redistribution and use in source and
binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public
License. A copy of this license is available in the file LICENSE in the top-level directory of the distribution
or, alternatively, at www.OpenLDAP.org/license.html. OpenLDAP is a registered trademark of the
OpenLDAP Foundation. Individual files and/or contributed packages may be copyrighted by other parties
and subject to additional restrictions. This work is derived from the University of Michigan LDAP v3.3
distribution. This work also contains materials derived from public sources. Information about OpenLDAP
can be obtained at www.openldap.org/ . Portions Copyright 1998-2004 Kurt D. Zeilenga. Portions Copyright
1998-2004 Net Boolean Incorporated. Portions Copyright 2001-2004 IBM Corporation. All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted only as
authorized by the OpenLDAP Public License. Portions Copyright 1999-2003 Howard Y.H. Chu. Portions
Copyright 1999-2003 Symas Corporation. Portions Copyright 1998-2003 Hallvard B. Furuseth. All rights
reserved. Redistribution and use in source and binary forms, with or without modification, are permitted
provided that this notice is preserved. The names of the copyright holders may not be used to endorse or
promote products derived from this software without their specific prior written permission. This software
is provided "as is'' without express or implied warranty. Portions Copyright (c) 1992-1996 Regents of the
University of Michigan. All rights reserved. Redistribution and use in source and binary forms are permitted
provided that this notice is preserved and that due credit is given to the University of Michigan at Ann Arbor.
The name of the University may not be used to endorse or promote products derived from this software
without specific prior written permission. This software is provided "as is'' without express or implied
warranty. Other trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks
and trade names other than its own.
December 2009
Contents
1 iDRAC6 Enterprise Overview . . . . . . . . . . 27
IPv6 Ready Logo Certification . . . . . . . . . . . . . . 28
iDRAC6 Security Features
. . . . . . . . . . . . . . . . 28
iDRAC6 Enterprise and VFlash Media. . . . . . . . . . 29
Supported Platforms
Supported Operating Systems
Supported Web Browsers
Supported Remote Access Connections
iDRAC6 Ports
Other Documents You May Need
. . . . . . . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . 31
. . . . . . . . . . . . . . . . 31
. . . . . . . . 32
. . . . . . . . . . . . . . . . . . . . . . . 32
. . . . . . . . . . . . 33
2 Configuring iDRAC6 Enterprise . . . . . . . . 37
Before You Begin . . . . . . . . . . . . . . . . . . . . 37
Interfaces for Configuring iDRAC6
Configuration Tasks
. . . . . . . . . . . . . . . . . . . 41
Configure the Management Station
Configure iDRAC6 Networking
Configure iDRAC6 Users
Configure Directory Services
Configure IP Filtering and IP Blocking
. . . . . . . . . . . 37
. . . . . . . . 41
. . . . . . . . . . . 41
. . . . . . . . . . . . . . 42
. . . . . . . . . . . . 42
. . . . . . . 42
Contents 3
Configure Platform Events . . . . . . . . . . . . . 43
Enabling or Disabling Local
Configuration Access
Configure iDRAC6 Services
Configure Secure Sockets Layer (SSL)
Configure Virtual Media
Configure a VFlash Media Card
Install the Managed Server Software
. . . . . . . . . . . . . . . . 43
. . . . . . . . . . . . . 43
. . . . . . . 44
. . . . . . . . . . . . . . . 44
. . . . . . . . . . . 44
. . . . . . . 44
Configure the Managed Server for the
Last Crash Screen Feature
. . . . . . . . . . . . . 44
Configuring Networking Using CMC
Web Interface
. . . . . . . . . . . . . . . . . . . . . . 45
Launching iDRAC6 Web Interface
From CMC
Configuring Networking for iDRAC6
. . . . . . . . . . . . . . . . . . . . . . 45
. . . . . . . . 47
Viewing FlexAddress Mezzanine Card
Fabric Connections
FlexAddress MAC for iDRAC6
. . . . . . . . . . . . . . . . . . . 48
. . . . . . . . . . . 48
4 Contents
Remote Syslog
Remote File Share
. . . . . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . . . . . . . . . . 51
Updating iDRAC6 Firmware
Downloading the Firmware or
Update Package
. . . . . . . . . . . . . . . . . . 54
Executing the Firmware Update
Verifying the Digital Signature
for Linux DUPs
. . . . . . . . . . . . . . . . . . . 55
Using iDRAC6 Web Interface
Updating iDRAC6 Firmware
Using RACADM
. . . . . . . . . . . . . . . . . . . 60
Using the DOS Update Utility
Clear Your Browser’s Cache
. . . . . . . . . . . . . . . 53
. . . . . . . . . . 54
. . . . . . . . . . . . 58
. . . . . . . . . . . . 60
. . . . . . . . . . . . 61
Updating the USC Repair Package . . . . . . . . . . . 61
Configuring iDRAC6 For Use
With IT Assistant
. . . . . . . . . . . . . . . . . . . . . 61
Using iDRAC6 Configuration Utility to
Enable Discovery and Monitoring
. . . . . . . . . . . . 61
Using iDRAC6 Web Interface to Enable
Discovery and Monitoring
. . . . . . . . . . . . . . . . 62
Using IT Assistant to View iDRAC6
Status and Events
. . . . . . . . . . . . . . . . . . . . 64
3 Configuring the Management
Station
. . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Management Station Set Up Steps . . . . . . . . . . . 65
Management Station Network Requirements
Configuring a Supported Web Browser
Opening Your Web Browser
. . . . . . . . . 66
. . . . . . . . . . . . 66
Configuring Your Web Browser to
Connect to the Web Interface
. . . . . . . . . . . 66
Adding iDRAC6 to the List of
Trusted Domains
. . . . . . . . . . . . . . . . . . 69
Viewing Localized Versions of the
Web Interface
Setting the Locale in Linux
. . . . . . . . . . . . . . . . . . . 70
. . . . . . . . . . . . . 71
Disabling the Whitelist Feature
in Firefox
. . . . . . . . . . . . . . . . . . . . . . 72
. . . . . 65
Contents 5
Installing iDRAC6 Software on the
Management Station
. . . . . . . . . . . . . . . . . . . 72
Installing and Uninstalling RACADM
on a Management Station
. . . . . . . . . . . . . 73
Installing and Uninstalling RACADM
on Linux
. . . . . . . . . . . . . . . . . . . . . . . 73
Installing a Java Runtime Environment (JRE)
Installing Telnet or SSH Clients
Telnet with iDRAC6
. . . . . . . . . . . . . 74
. . . . . . . . . . . . . . . . . 75
. . . . . . 73
Configuring the Backspace Key
For Telnet Sessions
SSH With iDRAC6
Installing a TFTP Server
Installing Dell OpenManage IT Assistant
Installing Dell Management Console
. . . . . . . . . . . . . . . . . 75
. . . . . . . . . . . . . . . . . . 76
. . . . . . . . . . . . . . . . . 77
. . . . . . . . 78
. . . . . . . . . . 78
4 Configuring the Managed Server . . . . . 79
Installing the Software on the Managed Server . . . . 79
Configuring the Managed Server to Capture
the Last Crash Screen
Disabling the Windows Automatic
Reboot Option
. . . . . . . . . . . . . . . . . . 80
. . . . . . . . . . . . . . . . . . . . . . 81
5 Configuring iDRAC6 Enterprise
Using the Web Interface
6 Contents
. . . . . . . . . . . . . 83
Accessing the Web Interface . . . . . . . . . . . . . . 84
Logging In
Logging Out
. . . . . . . . . . . . . . . . . . . . . . 84
. . . . . . . . . . . . . . . . . . . . . 85
Using Multiple Browser Tabs and Windows . . . . 85
Configuring iDRAC6 NIC
. . . . . . . . . . . . . . . . . 86
Configuring the Network, IPMI
and VLAN Settings
. . . . . . . . . . . . . . . . . 86
Configuring IP Filtering and IP Blocking
Configuring Platform Events
. . . . . . . . . . . . . . . 92
Configuring Platform Event Filters (PEF)
Configuring Platform Event Traps (PET)
Configuring E-Mail Alerts
Configuring IPMI Over LAN
Adding and Configuring iDRAC6 Users
. . . . . . . . . . . . . . 94
. . . . . . . . . . . . . . . 96
. . . . . . . . . 97
Public Key Authentication over SSH
Securing iDRAC6 Communications Using
SSL and Digital Certificates
Secure Sockets Layer (SSL)
Certificate Signing Request (CSR)
Accessing the SSL Main Menu
. . . . . . . . . . . . . . . 104
. . . . . . . . . . . . 105
. . . . . . . . . 105
. . . . . . . . . . 106
Generating a New Certificate
Signing Request
Uploading a Server Certificate
Viewing a Server Certificate
. . . . . . . . . . . . . . . . . . 107
. . . . . . . . . . . 108
. . . . . . . . . . . . 109
. . . . . . 91
. . . . . . 93
. . . . . . 94
. . . . . . . . 97
Configuring and Managing Microsoft
Active Directory Certificates
. . . . . . . . . . . . . . 110
Configuring Active Directory
(Standard Schema and Extended Schema)
Viewing an Active Directory CA Certificate
. . . . 111
. . . . 117
Enabling or Disabling Local Configuration Access
Enabling Local Configuration Access
Disabling Local Configuration Access
. . . . . . . 117
. . . . . . . 118
Contents 7
. . . 117
Configuring iDRAC6 Services . . . . . . . . . . . . . 118
Updating iDRAC6 Firmware
Updating iDRAC6 Firmware Using CMC
iDRAC6 Firmware Rollback
. . . . . . . . . . . . . . 120
. . . . . 121
. . . . . . . . . . . . 122
6 Using iDRAC6 Directory Service . . . . . . 125
Using iDRAC6 With Microsoft Active Directory. . . . 125
Prerequisites for Enabling Active
Directory Authentication for iDRAC6
Supported Active Directory Authentication
Mechanisms
. . . . . . . . . . . . . . . . . . . . . . 126
Extended Schema Active Directory Overview
Extending the Active Directory Schema
Active Directory Schema Extensions
Overview of iDRAC6 Schema Extensions
Active Directory Object Overview
Accumulating Privileges Using
Extended Schema
. . . . . . . . . . . . . . . . . 130
Configuring Extended Schema Active
Directory to Access iDRAC6
Installing the Dell Extension to the
Active Directory Users and
Computers Snap-In
. . . . . . . . . . . . . . . . 137
Adding iDRAC6 Users and Privileges
to Active Directory
. . . . . . . . . . . . . . . . 138
Configuring Microsoft Active Directory
With Extended Schema Using
iDRAC6 Web Interface
. . . . . . . . . . . . . . 140
Configuring Active Directory With
Extended Schema Using RACADM
. . . . . . . . . 126
. . . . 127
. . . . . 127
. . . . . . . 127
. . . . . 128
. . . . . . . . 128
. . . . . . . . . . . 131
. . . . . . . . 142
8 Contents
Standard Schema Active Directory Overview . . . . . 144
Single Domain Versus Multiple
Domain Scenarios
. . . . . . . . . . . . . . . . . 146
Configuring Standard Schema Active
Directory to Access iDRAC6
. . . . . . . . . . . . 147
Configuring Active Directory With
Standard Schema Using
iDRAC6 Web Interface
. . . . . . . . . . . . . . . 147
Configuring Active Directory With
Standard Schema Using RACADM
. . . . . . . . . 150
Testing Your Configurations
Enabling SSL on a Domain Controller
. . . . . . . . . . . . . . . 153
. . . . . . . . . . 153
Exporting the Domain Controller Root
CA Certificate to iDRAC6
. . . . . . . . . . . . . . 154
Importing iDRAC6 Firmware SSL Certificate
Using Active Directory to Log In to iDRAC6
Using Active Directory Single Sign-On
. . . . . . . . . 157
Configuring iDRAC6 to Use
Single Sign-On
. . . . . . . . . . . . . . . . . . . 157
Logging Into iDRAC6 Using Single
Sign-On
. . . . . . . . . . . . . . . . . . . . . . . 158
Using iDRAC6 with LDAP Directory Service
Login Syntax (Directory User versus
Local User)
. . . . . . . . . . . . . . . . . . . . . 159
Configuring Generic LDAP Directory
Service Using iDRAC6
Web-Based Interface
Frequently Asked Questions
Active Directory Log In Issues
. . . . . . . . . . . . . . . . 159
. . . . . . . . . . . . . . . 163
. . . . . . . . . . . 163
Active Directory Certificate Validation
Extended and Standard Schema
Miscellaneous
. . . . . . . . . . . . . . . . . . . 167
. . . . . . . . . . 167
. . . . 155
. . . . . . . 156
. . . . . . 159
. . . . . . . 166
Contents 9
7 Configuring Smart Card
Authentication
Configuring Smart Card Login in iDRAC6 . . . . . . . 169
Logging Into iDRAC6 Using Active
Directory Smart Card Authentication
Troubleshooting the Smart Card
Logon in iDRAC6
. . . . . . . . . . . . . . . . . . . . 169
. . . . . . . . . 170
. . . . . . . . . . . . . . . . . . . . 171
8 Enabling Kerberos Authentication . . . . 175
Prerequisites for single sign-on and Active
Directory Authentication Using Smart Card
Configuring iDRAC6 for single sign-on and
Active Directory Authentication
Using Smart Card
. . . . . . . . . . . . . . . . . . . . 178
Configuring Active Directory Users for
single sign-on Logon
. . . . . . . . . . . . . . . . . . 178
Logging Into iDRAC6 Using single sign-on
for Active Directory Users
. . . . . . . . . . . . . . . 179
. . . . . . 176
9 Viewing the Configuration and
Health of the Managed Server
10 Contents
Configuring Active Directory Users
for Smart Card Logon
iDRAC6 Login Scenarios with TFA and SSO
. . . . . . . . . . . . . . . . . . 179
. . . . . . 180
. . . . . . . 183
System Summary . . . . . . . . . . . . . . . . . . . . 183
System Details
Main System Enclosure
. . . . . . . . . . . . . . . . . . . . . 183
. . . . . . . . . . . . . . 183
Integrated Dell Remote Access
Controller 6 - Enterprise
. . . . . . . . . . . . . . 185
WWN/MAC
Server Health
. . . . . . . . . . . . . . . . . . . . . . . . 187
. . . . . . . . . . . . . . . . . . . . . . 187
. . . . . . . . . . . . . . . . . . . . . . . 187
iDRAC6
. . . . . . . . . . . . . . . . . . . . . . . . . 187
CMC
Batteries
Temperatures
Voltages
Power Monitoring
CPU
POST
Misc Health
. . . . . . . . . . . . . . . . . . . . . . 188
. . . . . . . . . . . . . . . . . . . . 188
. . . . . . . . . . . . . . . . . . . . . . . 188
. . . . . . . . . . . . . . . . . 188
. . . . . . . . . . . . . . . . . . . . . . . . . 189
. . . . . . . . . . . . . . . . . . . . . . . . 189
. . . . . . . . . . . . . . . . . . . . . 189
10 Configuring and Using
Serial Over LAN
Enabling Serial Over LAN in the BIOS. . . . . . . . . . 191
Configuring Serial Over LAN in iDRAC6 Web GUI
Using Serial Over LAN (SOL)
Model for Redirecting SOL Over
Telnet or SSH
Model for the SOL Proxy
Model for Redirecting SOL Over IPMItool
Disconnecting SOL session in
iDRAC6 Command Line Console
Using SOL over PuTTY
Using SOL over Telnet with Linux
Using SOL over OpenSSH with Linux
Using SOL over IPMItool
Opening SOL with SOL proxy
. . . . . . . . . . . . . . . . . . 191
. . . . . . . . . . . . . . . . . . . . 195
. . . 192
. . . . . . . . . . . . . . 195
. . . . . . . . . . . . . . 196
. . . . . 196
. . . . . . . . . . 196
. . . . . . . . . . . . . . . 197
. . . . . . . . . . 197
. . . . . . . . 198
. . . . . . . . . . . . . . 198
. . . . . . . . . . . . 199
Contents 11
Operating System Configuration . . . . . . . . . . . . 204
Linux Enterprise Operating System
Windows 2003 Enterprise
. . . . . . . . . . . . . 209
. . . . . . . . 204
11 Using GUI Console Redirection . . . . . . . 211
Overview . . . . . . . . . . . . . . . . . . . . . . . . 211
Using Console Redirection
Clear Your Browser’s Cache
. . . . . . . . . . . . . . 211
. . . . . . . . . . . 212
Supported Screen Resolutions
and Refresh Rates
. . . . . . . . . . . . . . . . 213
Configuring the Management Station
Configuring Console Redirection and
Virtual Media in iDRAC6 Web Interface
Opening a Console Redirection Session
Using the Video Viewer
. . . . . . . . . . . . . . . . 219
Synchronizing the Mouse Pointers
Disabling or Enabling Local Console
Launching vKVM and Virtual Media Remotely
URL Format
General Error Scenarios
. . . . . . . . . . . . . . . . . . . . 224
. . . . . . . . . . . . . 224
Frequently Asked Questions . . . . . . . . . . . . . . 225
12 Configuring the VFlash Media
Card for Use With iDRAC6
. . . . . . . . . . . 231
. . . . . . 213
. . . . . 214
. . . . . 216
. . . . . . . . 223
. . . . . . . 223
. . . . 224
12 Contents
Installing a VFlash Media Card . . . . . . . . . . . . 231
Removing a VFlash Media Card
. . . . . . . . . 232
Configuring the VFlash Media Card
Using iDRAC6 Web Interface
SD Card Properties
VFlash Drive
. . . . . . . . . . . . . . . . . 232
. . . . . . . . . . . . . . . . . . . . 234
Viewing the Virtual Flash Key Size
Configuring the VFlash Media
Card Using RACADM
. . . . . . . . . . . . . . . . . . . 235
Enabling or Disabling the VFlash
Media Card
. . . . . . . . . . . . . . . . . . . . . 235
Resetting the VFlash Media Card
13 Configuring and Using
Virtual Media
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 237
Windows-Based Management Station
Linux-Based Management Station
. . . . . . . . . . . . . . . . . . . . 237
. . . . . . . . . . . . . . 232
. . . . . . . . . 235
. . . . . . . . . . 235
. . . . . . 238
. . . . . . . . . 239
Configuring Virtual Media
Running Virtual Media
. . . . . . . . . . . . . . . . 239
. . . . . . . . . . . . . . . . . . 241
Disconnecting Virtual Media
Booting From Virtual Media
Installing Operating Systems
Using Virtual Media
. . . . . . . . . . . . . . . . 244
Using Virtual Media When the
Server’s Operating System Is Running
Frequently Asked Questions
. . . . . . . . . . . . . . . 245
. . . . . . . . . . . . 243
. . . . . . . . . . . . 243
. . . . . . . 244
Contents 13
14 Using the RACADM Command
Line Interface
RACADM Subcommands. . . . . . . . . . . . . . . . 250
. . . . . . . . . . . . . . . . . . . . 249
Supported RACADM Interfaces
Using local RACADM Commands
. . . . . . . . . . . . 252
. . . . . . . . . . . 254
Using the RACADM Utility to Configure iDRAC6
Displaying Current iDRAC6 Settings
. . . . . . . 255
Managing iDRAC6 Users with RACADM
Adding an iDRAC6 User
. . . . . . . . . . . . . . 257
Enabling an iDRAC6 User With Permissions
Uploading, Viewing, and Deleting
SSH Keys Using RACADM
Removing an iDRAC6 User
Testing E-mail Alerting
. . . . . . . . . . . . 258
. . . . . . . . . . . . 259
. . . . . . . . . . . . . . 259
Testing iDRAC6 SNMP Trap Alert Feature
Configuring iDRAC6 Network Properties
Configuring IPMI Over LAN
Configuring PEF
Configuring PET
. . . . . . . . . . . . . . . . . . 263
. . . . . . . . . . . . . . . . . . 264
Configuring IP Filtering (IP Range)
Configuring IP Blocking
. . . . . . . . . . . . 261
. . . . . . . . 265
. . . . . . . . . . . . . . 268
Configuring iDRAC6 Telnet and SSH
Services Using Local RACADM
. . . . . . . . . . 270
. . . 255
. . . . . 256
. . . 257
. . . . 260
. . . . . 260
14 Contents
Remote and SSH/Telnet RACADM
Remote RACADM Usage
. . . . . . . . . . . . . 271
Remote RACADM Options
. . . . . . . . . . . 270
. . . . . . . . . . . . 272
Using an iDRAC6 Configuration File. . . . . . . . . . . 273
Creating an iDRAC6 Configuration File
Configuration File Syntax
. . . . . . . . . . . . . . 273
. . . . . . . 273
Modifying iDRAC6 IP Address in
a Configuration File
Loading the Configuration File Into iDRAC6
. . . . . . . . . . . . . . . . . 275
. . . . 276
Configuring Multiple iDRAC6s
15 Power Monitoring and
Power Management
Configuring and Managing Power . . . . . . . . . . . 279
Power Monitoring
Viewing Power Monitoring
Power Budgeting
Viewing Power Budget
Power Budget Threshold
Power Control
Executing Power Control
Operations on the Server
. . . . . . . . . . . . . . . . . . . . . . 285
. . . . . . . . . . . . . . . 279
. . . . . . . . . . . . . . . . . . . . 280
. . . . . . . . . . . . . . . . . . . . 282
. . . . . . . . . . . . . . . 283
16 Using iDRAC6 Enterprise
SM-CLP Command
Line Interface
. . . . . . . . . . . . . . . . . . . . 287
. . . . . . . . . . . . . . 277
. . . . . . . . . . . . . 280
. . . . . . . . . . . . . . 284
. . . . . . . . . . . . . . 285
System Management With SM-CLP . . . . . . . . . . . 288
iDRAC6 SM-CLP Support
How to start an SM–CLP session
. . . . . . . . . . . . . . . . 288
. . . . . . . . . . 288
Contents 15
SM-CLP Features. . . . . . . . . . . . . . . . . . . . 289
Navigating the MAP Address Space
. . . . . . . . . . . . . . . . . . . . . . 292
Ta rg et s
. . . . . . . . . 291
Using the Show Verb. . . . . . . . . . . . . . . . . . 292
Using the -display Option
Using the -level Option
Using the -output Option
iDRAC6 SM-CLP Examples
Server Power Management
SEL Management
MAP Target Navigation
. . . . . . . . . . . . . 292
. . . . . . . . . . . . . . 293
. . . . . . . . . . . . . 293
. . . . . . . . . . . . . . . 293
. . . . . . . . . . . 293
. . . . . . . . . . . . . . . . . 294
. . . . . . . . . . . . . . 294
17 Using the WS-MAN Interface . . . . . . . . 299
WS-Management Features . . . . . . . . . . . . . . 299
Supported CIM Profiles
. . . . . . . . . . . . . . . . 300
18 Deploying Your Operating
System Using iVMCLI
. . . . . . . . . . . . . . 305
16 Contents
Before You Begin. . . . . . . . . . . . . . . . . . . . 305
Remote System Requirements
Network Requirements
Creating a Bootable Image File
Creating an Image File for Linux Systems
. . . . . . . . . . 305
. . . . . . . . . . . . . . 305
. . . . . . . . . . . . 306
. . . . 306
Creating an Image File for
Windows Systems
. . . . . . . . . . . . . . . . 306
Preparing for Deployment . . . . . . . . . . . . . . . . 306
Configuring the Remote Systems
. . . . . . . . . . 306
Deploying the Operating System
. . . . . . . . . . . . 307
Using the Virtual Media Command
Line Interface Utility
Installing the iVMCLI Utility
Command Line Options
iVMCLI Parameters
. . . . . . . . . . . . . . . . . . . 308
. . . . . . . . . . . . . 309
. . . . . . . . . . . . . . . 310
. . . . . . . . . . . . . . . . . 310
iVMCLI Operating System Shell Options
19 Using iDRAC6 Configuration
Utility
. . . . . . . . . . . . . . . . . . . . . . . . . . . 315
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 315
Starting iDRAC6 Configuration Utility
Using iDRAC6 Configuration Utility
iDRAC6 LAN
IPMI Over LAN
LAN Parameters
Virtual Media Configuration
System Services
LAN User Configuration
Reset to Default
System Event Log Menu
. . . . . . . . . . . . . . . . . . . . . 317
. . . . . . . . . . . . . . . . . . . 317
. . . . . . . . . . . . . . . . . . 318
. . . . . . . . . . . . 321
. . . . . . . . . . . . . . . . . . 322
. . . . . . . . . . . . . . 322
. . . . . . . . . . . . . . . . . . . 325
. . . . . . . . . . . . . . 325
Exiting iDRAC6 Configuration Utility
. . . . . . 313
. . . . . . . . . . 316
. . . . . . . . . . . 316
. . . . . . . . 326
Contents 17
20 Recovering and Troubleshooting
the Managed System
Safety First – For You and Your System . . . . . . . . 327
. . . . . . . . . . . . . . . 327
Trouble Indicators
LED Indicators
Hardware Trouble Indicators
Other Trouble Indicators
Problem Solving Tools
Checking the System Health
Checking the System Event Log (SEL)
Checking the Post Codes
Viewing the Last System Crash Screen
. . . . . . . . . . . . . . . . . . . 328
. . . . . . . . . . . . . . . . . . 328
. . . . . . . . . . . 329
. . . . . . . . . . . . . 329
. . . . . . . . . . . . . . . . . 330
. . . . . . . . . . . 330
. . . . . . 331
. . . . . . . . . . . . . 332
. . . . . . 332
Viewing the Most Recent Boot Sequences
Checking the Server Status Screen
for Error Messages
Viewing iDRAC6 Log
Viewing System Information
. . . . . . . . . . . . . . . . 334
. . . . . . . . . . . . . . . 342
. . . . . . . . . . . 343
Identifying the Managed Server in the Chassis
Using the Diagnostics Console
Managing Power on a Remote System
. . . . . . . . . . 344
. . . . . . 345
Troubleshooting and Frequently Asked Questions
. . . 333
. 344
. . 347
A RACADM Subcommand Overview . . . . . 353
18 Contents
help . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
. . . . . . . . . . . . . . . . . . . . . . . . . . 354
config
getconfig
getssninfo
. . . . . . . . . . . . . . . . . . . . . . . . 356
. . . . . . . . . . . . . . . . . . . . . . . 358
getsysinfo . . . . . . . . . . . . . . . . . . . . . . . . 360
getractime
setniccfg
getniccfg
getsvctag
racreset
racresetcfg
. . . . . . . . . . . . . . . . . . . . . . . . 364
. . . . . . . . . . . . . . . . . . . . . . . . . 365
. . . . . . . . . . . . . . . . . . . . . . . . . 367
. . . . . . . . . . . . . . . . . . . . . . . . . 368
. . . . . . . . . . . . . . . . . . . . . . . . . 369
. . . . . . . . . . . . . . . . . . . . . . . . 370
serveraction . . . . . . . . . . . . . . . . . . . . . . . 371
getraclog
clrraclog
getsel
clrsel
gettracelog
sslcsrgen
sslcertupload
. . . . . . . . . . . . . . . . . . . . . . . . . 372
. . . . . . . . . . . . . . . . . . . . . . . . . 373
. . . . . . . . . . . . . . . . . . . . . . . . . . . 374
. . . . . . . . . . . . . . . . . . . . . . . . . . . 375
. . . . . . . . . . . . . . . . . . . . . . . . 376
. . . . . . . . . . . . . . . . . . . . . . . . . 377
. . . . . . . . . . . . . . . . . . . . . . 379
sslcertdownload
sslcertview
. . . . . . . . . . . . . . . . . . . . . 380
. . . . . . . . . . . . . . . . . . . . . . . . 381
testemail . . . . . . . . . . . . . . . . . . . . . . . . . 383
testtrap
. . . . . . . . . . . . . . . . . . . . . . . . . . 384
vmdisconnect
clearasrscreen
. . . . . . . . . . . . . . . . . . . . . . 386
. . . . . . . . . . . . . . . . . . . . . . 386
Contents 19
localconredirdisable. . . . . . . . . . . . . . . . . . 387
fwupdate
krbkeytabupload
vmkey
version
arp
coredump
. . . . . . . . . . . . . . . . . . . . . . . . 387
. . . . . . . . . . . . . . . . . . . . 389
. . . . . . . . . . . . . . . . . . . . . . . . . . 390
. . . . . . . . . . . . . . . . . . . . . . . . . 391
. . . . . . . . . . . . . . . . . . . . . . . . . . . 391
. . . . . . . . . . . . . . . . . . . . . . . . 392
coredumpdelete . . . . . . . . . . . . . . . . . . . . 393
ifconfig
netstat
ping
ping6
racdump
traceroute
traceroute6
. . . . . . . . . . . . . . . . . . . . . . . . . 394
. . . . . . . . . . . . . . . . . . . . . . . . . 394
. . . . . . . . . . . . . . . . . . . . . . . . . . . 395
. . . . . . . . . . . . . . . . . . . . . . . . . . 396
. . . . . . . . . . . . . . . . . . . . . . . . 396
. . . . . . . . . . . . . . . . . . . . . . . 397
. . . . . . . . . . . . . . . . . . . . . . . 398
20 Contents
remoteimage
sshpkauth
. . . . . . . . . . . . . . . . . . . . . . 399
. . . . . . . . . . . . . . . . . . . . . . . 400
B iDRAC6 Enterprise Property
Database Group and Object
Definitions
. . . . . . . . . . . . . . . . . . . . . . . . . 403
Displayable Characters . . . . . . . . . . . . . . . . . 403
idRacInfo
. . . . . . . . . . . . . . . . . . . . . . . . . 404
idRacProductInfo (Read Only)
. . . . . . . . . . . 404
idRacDescriptionInfo (Read Only)
idRacVersionInfo (Read Only)
idRacBuildInfo (Read Only)
idRacName (Read Only)
idRacType (Read Only)
cfgOobSnmp
. . . . . . . . . . . . . . . . . . . . . . . 406
. . . . . . . . . . . 404
. . . . . . . . . . . . . 405
. . . . . . . . . . . . . . 405
. . . . . . . . . . . . . . . 405
cfgOobSnmpAgentCommunity (Read/Write)
cfgOobSnmpAgentEnable (Read/Write)
cfgLanNetworking
. . . . . . . . . . . . . . . . . . . . 407
cfgNicIPv4Enable (Read/Write)
cfgDNSDomainNameFromDHCP
(Read/Write)
. . . . . . . . . . . . . . . . . . . . 407
cfgDNSDomainName (Read/Write)
cfgDNSRacName (Read/Write)
cfgDNSRegisterRac (Read/Write)
cfgDNSServersFromDHCP (Read/Write)
cfgDNSServer1 (Read/Write)
cfgDNSServer2 (Read/Write)
cfgNicEnable (Read/Write)
cfgNicIpAddress (Read/Write)
cfgNicNetmask (Read/Write)
cfgNicGateway (Read/Write)
cfgNicUseDhcp (Read/Write)
. . . . . . . . . . . . 409
. . . . . . . . . . . . 410
. . . . . . . . . . . . . 410
. . . . . . . . . . . 411
. . . . . . . . . . . . 411
. . . . . . . . . . . . 411
. . . . . . . . . . . 412
cfgNicMacAddress (Read Only)
cfgNicVLanEnable (Read Only)
. . . . . . . . . . . 413
. . . . . . . . . 404
. . . . 406
. . . . . . 406
. . . . . . . . . . 407
. . . . . . . . 408
. . . . . . . . . . 408
. . . . . . . . . 409
. . . . . . 409
. . . . . . . . . . 412
Contents 21
cfgNicVLanID (Read Only) . . . . . . . . . . . . 413
cfgNicVLanPriority (Read Only)
. . . . . . . . . . 413
cfgIPv6URL
. . . . . . . . . . . . . . . . . . . . . . . 414
cfgIPv6URLstring (Read Only)
cfgIPv6LanNetworking
cfgIPv6Enable
. . . . . . . . . . . . . . . . . 414
. . . . . . . . . . . . . . . . . . . 414
cfgIPv6Address1 (Read/Write)
cfgIPv6Gateway (Read/Write)
cfgIPv6PrefixLength (Read/Write)
cfgIPv6AutoConfig (Read/Write)
cfgIPv6LinkLocalAddress (Read Only)
cfgIPv6Address2 (Read Only)
cfgIPv6DNSServersFromDHCP6
(Read/Write)
. . . . . . . . . . . . . . . . . . . 417
cfgIPv6DNSServer1 (Read/Write)
cfgIPv6DNSServer2 (Read/Write)
cfgIPv6Address3 (Read Only)
cfgIPv6Address4 (Read Only)
cfgIPv6Address5 (Read Only)
cfgIPv6Address6 (Read Only)
cfgIPv6Address7 (Read Only)
cfgIPv6Address8 (Read Only)
cfgIPv6Address9 (Read Only)
cfgIPv6Address10 (Read Only)
cfgIPv6Address11 (Read Only)
cfgIPv6Address12 (Read Only)
cfgIPv6Address13 (Read Only)
cfgIPv6Address14 (Read Only)
cfgIPv6Address15 (Read Only)
. . . . . . . . . . 414
. . . . . . . . . . 415
. . . . . . . . . . 415
. . . . . . . . 415
. . . . . . . . . 416
. . . . . . 416
. . . . . . . . . . . 416
. . . . . . . . 417
. . . . . . . . 417
. . . . . . . . . . . 418
. . . . . . . . . . . 418
. . . . . . . . . . . 418
. . . . . . . . . . . 418
. . . . . . . . . . . 418
. . . . . . . . . . . 419
. . . . . . . . . . . 419
. . . . . . . . . . 419
. . . . . . . . . . 419
. . . . . . . . . . 420
. . . . . . . . . . 420
. . . . . . . . . . 420
. . . . . . . . . . 420
22 Contents
cfgUserAdmin . . . . . . . . . . . . . . . . . . . . . . 420
cfgUserAdminIndex (Read Only)
cfgUserAdminIpmiLanPrivilege (Read/Write)
cfgUserAdminPrivilege (Read/Write)
cfgUserAdminUserName (Read/Write)
cfgUserAdminPassword (Write Only)
cfgUserAdminEnable (Read/Write)
cfgUserAdminSolEnable (Read/Write)
. . . . . . . . . . 421
. . . 421
. . . . . . . 421
. . . . . . 423
. . . . . . . 423
. . . . . . . . . 424
. . . . . . . 424
cfgEmailAlert
cfgEmailAlertIndex (Read Only)
. . . . . . . . . . . . . . . . . . . . . . 424
. . . . . . . . . . 424
cfgEmailAlertEnable (Read/Write)
cfgEmailAlertAddress (Read/Write)
cfgEmailAlertCustomMsg (Read/Write)
cfgSessionManagement
. . . . . . . . . . . . . . . . . 426
cfgSsnMgtConsRedirMaxSessions
(Read/Write)
. . . . . . . . . . . . . . . . . . . . 426
cfgSsnMgtWebserverTimeout (Read/Write)
cfgSsnMgtSshIdleTimeout (Read/Write)
cfgSsnMgtTelnetTimeout (Read/Write)
cfgSerial
. . . . . . . . . . . . . . . . . . . . . . . . . 428
cfgSerialSshEnable (Read/Write)
cfgSerialTelnetEnable (Read/Write)
cfgRemoteHosts
. . . . . . . . . . . . . . . . . . . . . 429
cfgRhostsSmtpServerIpAddr (Read/Write)
cfgRhostsFwUpdateTftpEnable (Read/Write)
cfgRhostsFwUpdateIpAddr (Read/Write)
cfgRhostsFwUpdatePath (Read/Write)
cfgRhostsSyslogEnable (Read/Write)
cfgRhostsSyslogPort (Read/Write)
cfgRhostsSyslogServer1 (Read/Write)
cfgRhostsSyslogServer2 (Read/Write)
. . . . . . . . . 425
. . . . . . . . 425
. . . . . . 425
. . . . 426
. . . . . . 427
. . . . . . 427
. . . . . . . . . 428
. . . . . . . . 429
. . . . 429
. . . 429
. . . . . 430
. . . . . . . 430
. . . . . . . 430
. . . . . . . . . 431
. . . . . . . 431
. . . . . . . 431
Contents 23
cfgRhostsSyslogServer3 (Read/Write) . . . . . . 432
cfgUserDomain
. . . . . . . . . . . . . . . . . . . . . 432
cfgUserDomainIndex (Read Only)
cfgUserDomainName (Read/Write)
cfgServerPower
. . . . . . . . . . . . . . . . . . . . 433
cfgServerPowerStatus (Read Only)
cfgServerActualPowerConsumption
(Read Only)
. . . . . . . . . . . . . . . . . . . . 433
cfgServerPeakPowerConsumption
(Read Only)
. . . . . . . . . . . . . . . . . . . . 434
cfgServerPeakPowerConsumptionTimestamp
(Read Only)
. . . . . . . . . . . . . . . . . . . . 434
cfgServerPowerConsumptionClear
(Write Only)
. . . . . . . . . . . . . . . . . . . . 434
cfgServerPowerCapWatts (Read Only)
cfgServerPowerCapBtuhr (Read Only)
cfgServerPowerCapPercent (Read Only)
cfgRacTuning
. . . . . . . . . . . . . . . . . . . . . . 436
cfgRacTuneHttpPort (Read/Write)
cfgRacTuneHttpsPort (Read/Write)
cfgRacTuneIpRangeEnable
cfgRacTuneIpRangeAddr
cfgRacTuneIpRangeMask
cfgRacTuneIpBlkEnable
cfgRacTuneIpBlkFailCount
cfgRacTuneIpBlkFailWindow
cfgRacTuneIpBlkPenaltyTime
. . . . . . . . . . . . 436
. . . . . . . . . . . . . 437
. . . . . . . . . . . . 437
. . . . . . . . . . . . . 437
. . . . . . . . . . . . 438
. . . . . . . . . . . 438
. . . . . . . . . . . 439
cfgRacTuneSshPort (Read/Write)
cfgRacTuneConRedirEnable (Read/Write)
cfgRacTuneTelnetPort (Read/Write)
. . . . . . . . 432
. . . . . . . 433
. . . . . . . 433
. . . . . . 435
. . . . . . 435
. . . . . 435
. . . . . . . . 436
. . . . . . . . 436
. . . . . . . . 439
. . . . 439
. . . . . . . 440
24 Contents
cfgRacTuneConRedirEncryptEnable
(Read/Write)
cfgRacTuneConRedirPort (Read/Write)
. . . . . . . . . . . . . . . . . . . . 440
. . . . . . 440
cfgRacTuneConRedirVideoPort (Read/Write)
cfgRacTuneAsrEnable (Read/Write)
. . . . . . . . 441
cfgRacTuneWebserverEnable (Read/Write)
cfgRacTuneLocalServerVideo (Read/Write)
cfgRacTuneDaylightOffset (Read/Write)
cfgRacTuneTimezoneOffset (Read/Write)
. . . . . . 442
. . . . . 442
cfgRacTuneLocalConfigDisable (Read/Write)
. . . 441
. . . . 441
. . . . 442
. . . 443
ifcRacManagedNodeOs
. . . . . . . . . . . . . . . . . 443
ifcRacMnOsHostname (Read Only)
ifcRacMnOsOsName (Read Only)
cfgRacSecurity
. . . . . . . . . . . . . . . . . . . . . . 444
cfgSecCsrCommonName (Read/Write)
cfgSecCsrOrganizationName (Read/Write)
cfgSecCsrOrganizationUnit (Read/Write)
cfgSecCsrLocalityName (Read/Write)
cfgSecCsrStateName (Read/Write)
cfgSecCsrCountryCode (Read/Write)
cfgSecCsrEmailAddr (Read/Write)
cfgSecCsrKeySize (Read/Write)
cfgRacVirtual
. . . . . . . . . . . . . . . . . . . . . . 447
cfgRacVirMediaAttached (Read/Write)
cfgVirMediaBootOnce (Read/Write)
cfgVirMediaKeyEnable (Read/Write)
cfgVirtualFloppyEmulation (Read/Write)
cfgSDWriteProtect (Read only)
cfgIpmiLan
. . . . . . . . . . . . . . . . . . . . . . . . 449
cfgIpmiLanEnable (Read/Write)
cfgIpmiLanPrivLimit (Read/Write)
. . . . . . . . 444
. . . . . . . . . 444
. . . . . . 444
. . . . 445
. . . . . 445
. . . . . . . 445
. . . . . . . . 446
. . . . . . . 446
. . . . . . . . . 446
. . . . . . . . . . 447
. . . . . . 447
. . . . . . . . 448
. . . . . . . . 448
. . . . . . 448
. . . . . . . . . . . 449
. . . . . . . . . . 449
. . . . . . . . . 450
Contents 25
cfgIpmiLanAlertEnable (Read/Write) . . . . . . . 450
cfgIpmiEncryptionKey (Read/Write)
cfgIpmiPetCommunityName (Read/Write)
. . . . . . . 450
. . . . 451
cfgIpmiPetIpv6
. . . . . . . . . . . . . . . . . . . . . 451
cfgIpmiPetIPv6Index (Read Only)
cfgIpmiPetIPv6AlertDestIpAddr
cfgIpmiPetIPv6AlertEnable (Read/Write)
cfgIpmiPef
. . . . . . . . . . . . . . . . . . . . . . . 452
cfgIpmiPefName (Read Only)
cfgIpmiPefIndex (Read/Write)
cfgIpmiPefAction (Read/Write)
cfgIpmiPefEnable (Read/Write)
cfgIpmiPet
. . . . . . . . . . . . . . . . . . . . . . . 454
cfgIpmiPetIndex (Read Only)
cfgIpmiPetAlertDestIpAddr (Read/Write)
cfgIpmiPetAlertEnable (Read/Write)
cfgSmartCard
. . . . . . . . . . . . . . . . . . . . . . 455
cfgSmartCardLogonEnable (Read/Write)
cfgActiveDirectory
. . . . . . . . . . . . . . . . . . . 455
cfgADSSOEnable (Read/Write)
cfgADRacDomain (Read/Write)
cfgADRacName (Read/Write)
cfgADEnable (Read/Write)
. . . . . . . . . . . . 456
cfgADAuthTimeout (Read/Write)
cfgADDomainController1 (Read/Write)
cfgADDomainController2 (Read/Write)
cfgADDomainController3 (Read/Write)
cfgADGlobalCatalog1 (Read/Write)
cfgADGlobalCatalog2 (Read/Write)
cfgADGlobalCatalog3 (Read/Write)
. . . . . . . . . 451
. . . . . . . . . 451
. . . . . 452
. . . . . . . . . . . 452
. . . . . . . . . . 453
. . . . . . . . . . 453
. . . . . . . . . . 453
. . . . . . . . . . . 454
. . . . 454
. . . . . . . 454
. . . . . 455
. . . . . . . . . . 455
. . . . . . . . . . 456
. . . . . . . . . . 456
. . . . . . . . . 457
. . . . . . 457
. . . . . 458
. . . . . . 458
. . . . . . . . 458
. . . . . . . . 459
. . . . . . . . 459
26 Contents
cfgADType (Read/Write) . . . . . . . . . . . . . . 459
cfgADCertValidationEnable (Read/Write)
cfgADDcSRVLookupEnable (Read/Write)
. . . . . 460
. . . . . 460
cfgADDcSRVLookupbyUserdomain
(Read/Write)
. . . . . . . . . . . . . . . . . . . . 461
cfgADDcSRVLookupDomainName
(Read/Write)
cfgADGcSRVLookupEnable (Read/Write)
cfgADGcRootDomain (Read/Write)
. . . . . . . . . . . . . . . . . . . . 461
. . . . . 462
. . . . . . . . 462
cfgLDAP
. . . . . . . . . . . . . . . . . . . . . . . . . 462
cfgLdapEnable (Read/Write)
cfgLdapServer (Read/Write)
cfgLdapPort (Read/Write)
. . . . . . . . . . . . 463
. . . . . . . . . . . . 463
. . . . . . . . . . . . . 463
cfgLdapBasedn (Read/Write)
cfgLdapUserAttribute (Read/Write)
cfgLdapGroupAttribute (Read/Write).
cfgLdapGroupAttributeIsDN (Read/Write)
cfgLdapBinddn (Read/Write)
. . . . . . . . . . . . 465
cfgLdapBindpassword (Write only)
cfgLdapSearchFilter (Read/Write)
cfgLDAPCertValidationEnable
(Read/Write)
cfgLdapRoleGroup
. . . . . . . . . . . . . . . . . . . . 466
. . . . . . . . . . . . . . . . . . . . 467
cfgLdapRoleGroupIndex (Read Only)
cfgLdapRoleGroupDN (Read/Write)
cfgLdapRoleGroupPrivilege (Read/Write)
cfgStandardSchema
. . . . . . . . . . . . . . . . . . . 468
cfgSSADRoleGroupIndex (Read Only)
cfgSSADRoleGroupName (Read/Write)
cfgSSADRoleGroupDomain (Read/Write)
cfgSSADRoleGroupPrivilege (Read/Write)
. . . . . . . . . . . 464
. . . . . . . . 464
. . . . . . . 464
. . . . . 465
. . . . . . . . 466
. . . . . . . . . 466
. . . . . . . . 467
. . . . . . . . 467
. . . . . 468
. . . . . . . 468
. . . . . . 468
. . . . . 469
. . . . . 469
Contents 27
cfgIpmiSol . . . . . . . . . . . . . . . . . . . . . . . 470
cfgIpmiSolEnable (Read/Write)
cfgIpmiSolBaudRate (Read/Write)
cfgIpmiSolMinPrivilege (Read/Write)
cfgIpmiSolAccumulateInterval (Read/Write)
cfgIpmiSolSendThreshold (Read/Write)
. . . . . . . . . . 470
. . . . . . . . 470
. . . . . . 471
. . . 471
. . . . . 471
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
28 Contents
iDRAC6 Enterprise Overview
The Integrated Dell™ Remote Access Controller (iDRAC6) Enterprise is a
systems management hardware and software solution that provides remote
management capabilities, crashed system recovery, and power control
functions for Dell PowerEdge™ systems.
iDRAC6 uses an integrated system-on-chip microprocessor for the remote
monitor/control system, and co-exists on the system board with the managed
Dell PowerEdge server. The server operating system executes application
programs; iDRAC6 monitors and manages the server’s environment and state
outside of the operating system.
iDRAC6 can be configured to send an e-mail or Simple Network
Management Protocol (SNMP) trap alert for warnings or errors. To help you
diagnose the cause of a system crash, iDRAC6 can log event data and capture
an image of the screen when it detects that the system has crashed.
Managed servers are installed in a Dell M1000e system enclosure (chassis)
with modular power supplies, cooling fans, and a Chassis Management
Controller (CMC). CMC monitors and manages all components installed in
the chassis. A redundant CMC can be added to provide hot failover if the
primary CMC fails. The chassis provides access to iDRAC6 devices through
its LCD display, local console connections, and its Web interface. Each blade
in a chassis has an iDRAC6. A total of 16 blades can be installed in the
M1000e.
All network connections to iDRAC6 are routed through CMC network
interfaces (CMC RJ45 connection port labeled "GB1"). CMC routes traffic to
the iDRAC6 devices through a private, internal network. This private
management network is outside of the server’s data path and outside of the
operating system’s control—that is, it is out-of-band . The managed server
inband network interfaces are accessed through I/O modules (IOMs) installed
in the chassis.
's
iDRAC6 Enterprise Overview 29
NOTE: It is recommended that you isolate or separate the chassis management
network, used by iDRAC6 and CMC, from your production network(s). Mixing
management and production or application network traffic may cause congestion
or network saturation resulting in CMC and iDRAC6 communication delays. The
delays may cause unpredictable chassis behavior such as CMC displaying that
iDRAC6 is offline even though it is operating properly. This may also cause other
unpredictable behavior.
iDRAC6 network interface is disabled by default. It must be configured
before iDRAC6 is accessible. After iDRAC6 is enabled and configured on the
network, it can be accessed through its assigned IP address with iDRAC6
Web interface, Telnet or SSH, and supported network management
protocols, such as Intelligent Platform Management Interface (IPMI).
IPv6 Ready Logo Certification
The IPv6 Ready Logo Committee's mission is to define the test specifications
for IPv6 conformance and interoperability testing, to provide access to
self
-test tools, and to deliver the IPv6 Ready Logo.
iDRAC6 is Phase
02-C-000380. For information on the IPv6 Ready Logo Program, see
http://www.ipv6ready.org/.
-2 IPv6 Ready Logo certified and the Logo ID is
iDRAC6 Security Features
• User authentication through Microsoft Active Directory, generic LDAP
Directory Service, or locally administered user IDs and passwords
• Two-factor authentication provided by the Smart–Card logon feature. The
two-factor authentication is based on what the users
Smart– Card) and what they
• Role-based authorization, which enables an administrator to configure
specific privileges for each user
• User ID and password configuration
• SM-CLP and Web interfaces that support 128-bit and 40-bit encryption
(for countries where 128 bit is not acceptable), using the SSL 3.0 standard
• Session time-out configuration (in seconds)
• Configurable IP ports (where applicable)
know
(the PIN)
have
(the
30 iDRAC6 Enterprise Overview