Dell iDRAC6 Enterprise Owner's Manual

Integrated Dell™ Remote
Access Controller 6 (iDRAC6)
Enterprise for Blade Servers
Version 2.1

User Guide

Notes and Cautions

your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
__________________
Information in this document is subject to change without notice. © 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, OpenManage, and PowerEdge are trademarks of Dell Inc.; Microsoft, Windows, W indows Server, Internet Explorer , MS-DOS, Windows Vista, ActiveX and Active Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; Red Hat and Linux are registered trademarks of Red Hat, Inc.; Novell and SUSE are registered trademarks of Novell Corporation. Intel is a registered trademark of Intel Corporation; UNIX is a registered trademark of The Open Group in the United States and other countries.
Copyright 1998-2009 The OpenLDAP Foundation. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public License. A copy of this license is available in the file LICENSE in the top-level directory of the distribution or, alternati vely, at www.OpenLDAP.org/license.html. OpenLDAP is a registered trademark of the OpenLDAP Foundation. Indi vidual files and/or contributed packages may be copyrighted by other parties and subject to additional restrictions. This work is derived from the University of Michigan LDAP v3.3 distrib ution. This work also contains materials derived from public sources. Information about OpenLDAP can be obtained at www.openldap.org/. Portions Copyright 1998-2004 Kurt D. Zeilenga. Portions Copyright 1998-2004 Net Boolean Incorporated. Portions Copyright 2001-2004 IBM Corporation. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public License. Portions Copyright 1999-2003 Howard Y.H. Chu. Portions Copyright 1999-2003 Symas Corporation. Portions Copyright 1998-2003 Hallvard B. Furuseth. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that this notice is preserved. The names of the copyright holders may not be used to endorse or promote products derived from this software without their specific prior written permission. This software is provided "as is'' without express or implied warranty. Portions Copyright (c) 1992-1996 Regents of the University of Michigan. All rights reserved. Redistribution and use in source and binary forms are permitted provided that this notice is preserved and that due credit is given to the Uni versity of Michigan at Ann Arbor. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission. This software is provided "as is'' without express or implied warranty . Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
August 2009
Contents
1 iDRAC6 Enterprise Overview . . . . . . . . . . 29
IPv6 Ready Logo Certification . . . . . . . . . . . . . . 30
iDRAC6 Security Features
iDRAC6 Enterprise and vFlash Media
Supported Platforms
Supported Operating Systems
Supported Web Browsers
Supported Remote Access Connections
iDRAC6 Ports
. . . . . . . . . . . . . . . . . . . . . . . 34
Other Documents You May Need
. . . . . . . . . . . . . . . . 30
. . . . . . . . . . 31
. . . . . . . . . . . . . . . . . . . 33
. . . . . . . . . . . . . . 34
. . . . . . . . . . . . . . . . 34
. . . . . . . . 34
. . . . . . . . . . . . 35
2 Configuring iDRAC6 Enterprise . . . . . . . . 39
Before You Begin . . . . . . . . . . . . . . . . . . . . 39
Interfaces for Configuring iDRAC6
Configuration Tasks
. . . . . . . . . . . . . . . . . . . 43
Configure the Management Station
Configure iDRAC6 Networking
Configure iDRAC6 Users
Configure Active Directory
Configure IP Filtering and IP Blocking
. . . . . . . . . . . 39
. . . . . . . . 43
. . . . . . . . . . . 43
. . . . . . . . . . . . . . 44
. . . . . . . . . . . . . 44
. . . . . . . 44
Contents 3
Configure Platform Events . . . . . . . . . . . . . 45
Enabling or Disabling Local Configuration Access
Configure iDRAC6 Services
Configure Secure Sockets Layer (SSL)
Configure Virtual Media
Configure a vFlash Media Card
Install the Managed Server Software
. . . . . . . . . . . . . . . . 45
. . . . . . . . . . . . . 45
. . . . . . . 46
. . . . . . . . . . . . . . . 46
. . . . . . . . . . . 46
. . . . . . . 46
Configure the Managed Server for the Last Crash Screen Feature
. . . . . . . . . . . . . 46
Configuring Networking Using the CMC Web Interface
. . . . . . . . . . . . . . . . . . . 47
Launching iDRAC6 Web Interface From the CMC
Configuring Networking for iDRAC6
. . . . . . . . . . . . . . . . . . . . 47
. . . . . . . . 49
Viewing FlexAddress Mezzanine Card Fabric Connections
FlexAddress MAC for iDRAC6
. . . . . . . . . . . . . . . . . . . 50
. . . . . . . . . . . 51
4 Contents
Remote Syslog
Remote File Share
. . . . . . . . . . . . . . . . . . . . . . 52
. . . . . . . . . . . . . . . . . . . . 53
Updating iDRAC6 Firmware
Downloading the Firmware or Update Package
. . . . . . . . . . . . . . . . . . 55
Executing the Firmware Update
Verifying the Digital Signature for Linux DUPs
. . . . . . . . . . . . . . . . . . . 57
Using iDRAC6 Web Interface
Updating iDRAC6 Firmware Using RACADM
. . . . . . . . . . . . . . . . . . . 61
Using the DOS Update Utility
Clear Your Browser’s Cache
. . . . . . . . . . . . . . . 55
. . . . . . . . . . 56
. . . . . . . . . . . . 60
. . . . . . . . . . . . 62
. . . . . . . . . . . . 63
Updating the USC Repair Package . . . . . . . . . . . 63
Configuring iDRAC6 For Use With IT Assistant
. . . . . . . . . . . . . . . . . . . . . 63
Using iDRAC6 Configuration Utility to Enable Discovery and Monitoring
Using iDRAC6 Web Interface to Enable Discovery and Monitoring
. . . . . . . . . . . . . . . . 64
Using IT Assistant to View iDRAC6 Status and Events
. . . . . . . . . . . . . . . . . . . . 66
3 Configuring the Management
Station
. . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Management Station Set Up Steps . . . . . . . . . . . 67
. . . . . . . . . . 63
Management Station Network Requirements
Configuring a Supported Web Browser
Opening Your Web Browser
. . . . . . . . . 68
. . . . . . . . . . . . 68
Configuring Your Web Browser to Connect to the Web Interface
. . . . . . . . . . . 68
Adding iDRAC6 to the List of Trusted Domains
. . . . . . . . . . . . . . . . . . 71
Viewing Localized Versions of the Web Interface
Setting the Locale in Linux
. . . . . . . . . . . . . . . . . . . 71
. . . . . . . . . . . . . 72
Disabling the Whitelist Feature in Firefox
Installing iDRAC6 Software on the Management Station
. . . . . . . . . . . . . . . . . . . 74
Installing and Removing RACADM on a Linux Management Station
Installing RACADM
. . . . . . . . . . . . . . . . . 74
Uninstalling RACADM
. . . . . . . . . . . . 74
. . . . . . . . . . . . . . . 75
. . . . . 67
. . . . . 73
Contents 5
Installing a Java Runtime Environment (JRE) . . . . . . 75
Installing Telnet or SSH Clients
Telnet with iDRAC6
. . . . . . . . . . . . . . . . . 76
Configuring the Backspace Key For Telnet Sessions
SSH With iDRAC6
Installing a TFTP Server
. . . . . . . . . . . . . . . . . 77
. . . . . . . . . . . . . . . . . . 77
. . . . . . . . . . . . . . . . . 79
Installing Dell OpenManage IT Assistant
Installing Dell Management Console
4 Configuring the Managed
Server
. . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Installing the Software on the Managed Server
. . . . . . . . . . . . . . . . . . . . . 81
Configuring the Managed Server to Capture the Last Crash Screen
Disabling the Windows Automatic Reboot Option
. . . . . . . . . . . . . . . . . . . . . . 83
. . . . . . . . . . . . . 76
. . . . . . . . 79
. . . . . . . . . . 80
. . . . . . . . . . . . . . 82
5 Configuring iDRAC6 Enterprise
Using the Web Interface
6 Contents
. . . . . . . . . . . . . 85
Accessing the Web Interface . . . . . . . . . . . . . . 86
Logging In
Logging Out
. . . . . . . . . . . . . . . . . . . . . . 86
. . . . . . . . . . . . . . . . . . . . . 87
Using Multiple Browser Tabs and Windows
. . . . . . . . . . . . . . . . . . . . 87
Configuring iDRAC6 NIC . . . . . . . . . . . . . . . . . 88
Configuring the Network, IPMI and VLAN Settings
Configuring IP Filtering and IP Blocking
. . . . . . . . . . . . . . . . . 88
. . . . . . 92
Configuring Platform Events
. . . . . . . . . . . . . . . 94
Configuring Platform Event Filters (PEF)
Configuring Platform Event Traps (PET)
Configuring E-Mail Alerts
Configuring IPMI Over LAN
Adding and Configuring iDRAC6 Users
. . . . . . . . . . . . . . 96
. . . . . . . . . . . . . . . 97
. . . . . . . . . 98
Securing iDRAC6 Communications Using SSL and Digital Certificates
Secure Sockets Layer (SSL)
Certificate Signing Request (CSR)
Accessing the SSL Main Menu
. . . . . . . . . . . . . . . 101
. . . . . . . . . . . . 102
. . . . . . . . . 102
. . . . . . . . . . 103
Generating a New Certificate Signing Request
Uploading a Server Certificate
Viewing a Server Certificate
. . . . . . . . . . . . . . . . . . 104
. . . . . . . . . . . 105
. . . . . . . . . . . . 106
Configuring and Managing Active Directory Certificates
. . . . . . . . . . . . . . . . . . 107
Configuring Active Directory (Standard Schema and Extended Schema)
. . . . . . . . . . 108
Viewing an Active Directory CA Certificate
. . . . . . . . . . . . . . . . . . . . 113
. . . . . . 95
. . . . . . 95
Enabling or Disabling Local Configuration Access
. . . . . . . . . . . . . . . . . . 113
Enabling Local Configuration Access
Disabling Local Configuration Access
. . . . . . . 113
. . . . . . . 113
Contents 7
Configuring iDRAC6 Services . . . . . . . . . . . . . 114
Updating iDRAC6 Firmware
. . . . . . . . . . . . . . 116
Updating iDRAC6 Firmware Using the CMC
iDRAC6 Firmware Rollback
. . . . . . . . . . . . . . . . . . 118
. . . . . . . . . . . . 118
6 Using iDRAC6 With Microsoft
Active Directory
Prerequisites for Enabling Active Directory Authentication for iDRAC6
Supported Active Directory Authentication Mechanisms
Extended Schema Active Directory Overview
Extending the Active Directory Schema
Active Directory Schema Extensions
Overview of iDRAC6 Schema Extensions
Active Directory Object Overview
Accumulating Privileges Using Extended Schema
Configuring Extended Schema Active Directory to Access iDRAC6
Installing the Dell Extension to the Active Directory Users and Computers Snap-In
Adding iDRAC6 Users and Privileges to Active Directory
Configuring Active Directory With Extended Schema Using iDRAC6 Web Interface
Configuring Active Directory With Extended Schema Using RACADM
. . . . . . . . . . . . . . . . . . 121
. . . . . . . . . . . . . . 122
. . . . . . . . . . . . . . . . . 126
. . . . . . . . . . . . . . . . 133
. . . . . . . . . . . . . . . . 134
. . . . . . . . . . . . . . . . . . . 136
. . . . . . . . . 122
. . . . 123
. . . . . 123
. . . . . . . 123
. . . . . 124
. . . . . . . . 124
. . . . . . . 127
. . . . . . . . 138
8 Contents
Standard Schema Active Directory Overview
. . . . . . . . . . . . . . . . . . . . . . . . . 140
Single Domain Versus Multiple Domain Scenarios
. . . . . . . . . . . . . . . . . 142
Configuring Standard Schema Active Directory to Access iDRAC6
Configuring Active Directory With Standard Schema Using iDRAC6 Web Interface
. . . . . . . . . . . . . . . . . . . 143
Configuring Active Directory With Standard Schema Using RACADM
. . . . . . . . . . . . 143
. . . . . . . . . 146
Testing Your Configurations
Enabling SSL on a Domain Controller
. . . . . . . . . . . . . . . 148
. . . . . . . . . . 149
Exporting the Domain Controller Root CA Certificate to iDRAC6
. . . . . . . . . . . . . . 149
Importing iDRAC6 Firmware SSL Certificate
. . . . . . . . . . . . . . . . . . . . . . 150
Using Active Directory to Log In to iDRAC6
Using Active Directory Single Sign-On
. . . . . . . . . 152
Configuring iDRAC6 to Use Single Sign-On
Logging Into iDRAC6 Using Single Sign-On
Frequently Asked Questions
Active Directory Log In Issues
. . . . . . . . . . . . . . . 154
. . . . . . . . . . . 154
Active Directory Certificate Validation
Extended and Standard Schema
Miscellaneous
. . . . . . . . . . . . . . . . . . . 159
. . . . . . . . . . 158
. . . . . . . 151
. . . . 152
. . . . 154
. . . . . . . 158
Contents 9
7 Configuring Smart Card
Authentication
Configuring Smart Card Login in iDRAC6 . . . . . . . 161
Logging Into iDRAC6 Using Active Directory Smart Card Authentication
Troubleshooting the Smart Card Logon in iDRAC6
. . . . . . . . . . . . . . . . . . . . 161
. . . . . . . . . 163
. . . . . . . . . . . . . . . . . . . . 163
8 Enabling Kerberos Authentication . . . . 167
Prerequisites for single sign-on and Active Directory Authentication Using Smart Card
Configuring iDRAC6 for single sign-on and Active Directory Authentication Using Smart Card
. . . . . . . . . . . . . . . . . . . . 170
Configuring Active Directory Users for single sign-on Logon
. . . . . . . . . . . . . . . . . . 170
Logging Into iDRAC6 Using single sign-on for Active Directory Users
. . . . . . . . . . . . . . . 170
. . . . . . 168
9 Viewing the Configuration and
Health of the Managed Server
10 Contents
Configuring Active Directory Users for Smart Card Logon
iDRAC6 Login Scenarios with TFA and SSO
. . . . . . . . . . . . . . . . . . 171
. . . . . . 172
. . . . . . . 173
System Summary . . . . . . . . . . . . . . . . . . . . 173
Main System Enclosure
. . . . . . . . . . . . . . 173
Integrated Dell Remote Access Controller 6 - Enterprise
. . . . . . . . . . . . . . 174
WWN/MAC. . . . . . . . . . . . . . . . . . . . . . . . 176
. . . . . . . . . . . . . . . . . . . . . . . . . . 176
Health
. . . . . . . . . . . . . . . . . . . . . . . 176
iDRAC6
CMC
. . . . . . . . . . . . . . . . . . . . . . . . . 176
Batteries
Temperatures
Voltages
Power Monitoring
CPU
POST
Misc Health
. . . . . . . . . . . . . . . . . . . . . . 177
. . . . . . . . . . . . . . . . . . . . 177
. . . . . . . . . . . . . . . . . . . . . . . 177
. . . . . . . . . . . . . . . . . 177
. . . . . . . . . . . . . . . . . . . . . . . . . 178
. . . . . . . . . . . . . . . . . . . . . . . . 178
. . . . . . . . . . . . . . . . . . . . . 178
10 Power Monitoring and
Power Management
Configuring and Managing Power . . . . . . . . . . . 179
. . . . . . . . . . . . . . . 179
Power Monitoring
. . . . . . . . . . . . . . . . . . . . 180
Viewing Power Monitoring
Power Budgeting
. . . . . . . . . . . . . . . . . . . . 182
Viewing Power Budget
Power Budget Threshold
Power Control
. . . . . . . . . . . . . . . . . . . . . . 185
Executing Power Control Operations on the Server
. . . . . . . . . . . . . 180
. . . . . . . . . . . . . . . 183
. . . . . . . . . . . . . . 183
. . . . . . . . . . . . . . 185
Contents 11
11 Configuring and Using
Serial Over LAN
Enabling Serial Over LAN in the BIOS. . . . . . . . . 187
Configuring Serial Over LAN in iDRAC6 Web GUI
. . . . . . . . . . . . . . . . . . . 187
. . . . . . . . . . . . . . . . . . . . 188
Using Serial Over LAN (SOL)
. . . . . . . . . . . . . . 191
Model for Redirecting SOL Over Telnet or SSH
Model for the SOL Proxy
Model for Redirecting SOL Over IPMItool
. . . . . . . . . . . . . . . . 191
. . . . . . . . . . . . . 192
. . . . 192
Disconnecting SOL session in iDRAC6 Command Line Console
Using SOL over PuTTY
. . . . . . . . . . . . . . 193
Using SOL over Telnet with Linux
Using SOL over OpenSSH with Linux
Using SOL over IPMItool
Opening SOL with SOL proxy
Operating System Configuration
Linux Enterprise Operating System
Windows 2003 Enterprise
. . . . . . . . . 192
. . . . . . . . . 193
. . . . . . . 194
. . . . . . . . . . . . . 194
. . . . . . . . . . . 195
. . . . . . . . . . . . 200
. . . . . . . . 200
. . . . . . . . . . . . . 205
12 Using GUI Console Redirection . . . . . . . 207
Overview . . . . . . . . . . . . . . . . . . . . . . . . 207
Using Console Redirection
Supported Screen Resolutions and Refresh Rates
Configuring the Management Station
Configuring Console Redirection and Virtual Media in iDRAC6 Web Interface
Opening a Console Redirection Session
. . . . . . . . . . . . . . 207
. . . . . . . . . . . . . . . . 208
. . . . . . 208
. . . . . 209
. . . . . 211
12 Contents
Using the Video Viewer . . . . . . . . . . . . . . . . . 213
Synchronizing the Mouse Pointers
Disabling or Enabling Local Console
. . . . . . . . . 217
. . . . . . . . 217
Frequently Asked Questions
. . . . . . . . . . . . . . . 218
13 Configuring the vFlash Media
Card for Use With iDRAC6
Installing a vFlash Media Card . . . . . . . . . . . . . 223
Removing a vFlash Media Card
Configuring the vFlash Media Card Using iDRAC6 Web Interface
Enabling or Disabling the vFlash Media Card
Formatting the vFlash Media Card
Uploading Disk Image
Viewing the vFlash Key Size
Configuring the vFlash Media Card Using RACADM
Enabling or Disabling the vFlash Media Card
Resetting the vFlash Media Card
. . . . . . . . . . . . . . . . . 224
. . . . . . . . . . . . . . . . . . . 226
. . . . . . . . . . . . . . . . . 226
. . . . . . . . . . 223
. . . . . . . . . . . 224
. . . . . . . . . . . . . . 224
. . . . . . . . . . . . . . . 225
. . . . . . . . . . . . 226
. . . . . . . . . 225
. . . . . . . . . . 227
14 Configuring and Using
Virtual Media
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 229
Windows-Based Management Station
Linux-Based Management Station
. . . . . . . . . . . . . . . . . . . . 229
. . . . . . 230
. . . . . . . . . 231
Contents 13
Configuring Virtual Media . . . . . . . . . . . . . . . 232
Running Virtual Media
Disconnecting Virtual Media
Booting From Virtual Media
Installing Operating Systems Using Virtual Media
Using Virtual Media When the Server’s Operating System Is Running
Frequently Asked Questions . . . . . . . . . . . . . . 236
15 Using the RACADM
Command Line Interface
RACADM Subcommands. . . . . . . . . . . . . . . . 242
Supported RACADM Interfaces
Using local RACADM Commands
Using the RACADM Utility to Configure iDRAC6
Displaying Current iDRAC6 Settings
Managing iDRAC6 Users with RACADM
Adding an iDRAC6 User
Enabling an iDRAC6 User With Permissions
Removing an iDRAC6 User
Testing E-mail Alerting
Testing iDRAC6 SNMP Trap Alert Feature
Configuring iDRAC6 Network Properties
Configuring IPMI Over LAN
Configuring PEF
Configuring PET
Configuring IP Filtering (IP Range)
. . . . . . . . . . . . . . . . . . . 247
. . . . . . . . . . . . . . . . . 233
. . . . . . . . . . . 235
. . . . . . . . . . . . 235
. . . . . . . . . . . . . . . 236
. . . . . . 236
. . . . . . . . . . . . 241
. . . . . . . . . . . . 244
. . . . . . . . . . . 246
. . . . . . . 247
. . . . . 248
. . . . . . . . . . . . . . 249
. . . . . . . . . . . . . . . . . 249
. . . . . . . . . . . . 250
. . . . . . . . . . . . . . 250
. . . . 251
. . . . . 251
. . . . . . . . . . . . 252
. . . . . . . . . . . . . . . . . . 254
. . . . . . . . . . . . . . . . . . 255
. . . . . . . . 257
14 Contents
Configuring IP Filtering . . . . . . . . . . . . . . . 258
Configuring IP Blocking
. . . . . . . . . . . . . . . 259
Configuring iDRAC6 Telnet and SSH Services Using Local RACADM
. . . . . . . . . . 261
Remote and SSH/Telnet RACADM
Remote RACADM Usage
Remote RACADM Options
. . . . . . . . . . . . . . 263
. . . . . . . . . . . . . 263
Using an iDRAC6 Configuration File
Creating an iDRAC6 Configuration File
Configuration File Syntax
. . . . . . . . . . . . . . 265
Modifying iDRAC6 IP Address in a Configuration File
. . . . . . . . . . . . . . . 267
Loading the Configuration File Into iDRAC6
Configuring Multiple iDRAC6s
. . . . . . . . . . . . . . . . . . . . . 268
. . . . . . . . . . . . . . 268
16 Using iDRAC6 Enterprise
SM-CLP Command Line Interface
System Management With SM-CLP . . . . . . . . . . . 272
iDRAC6 SM-CLP Support
How to start a SM–CLP session
SM-CLP Features . . . . . . . . . . . . . . . . . . . . 273
. . . . . . . . . . . . . . . . 272
. . . . . . . . . . . . 262
. . . . . . . . . . . 264
. . . . . . . 264
. . . . . 271
. . . . . . . . . . 272
Navigating the MAP Address Space
Ta rg et s
. . . . . . . . . . . . . . . . . . . . . . . 276
Using the Show Verb
Using the -display Option
Using the -level Option
Using the -output Option
. . . . . . . . . . . . . . . . . . 276
. . . . . . . . . . . . . . 276
. . . . . . . . . . . . . . . 277
. . . . . . . . . . . . . . 277
. . . . . . . . . . 276
Contents 15
iDRAC6 SM-CLP Examples. . . . . . . . . . . . . . . 277
Server Power Management
SEL Management
. . . . . . . . . . . . . . . . . 278
MAP Target Navigation
. . . . . . . . . . . 278
. . . . . . . . . . . . . . 278
Updating iDRAC6 Firmware Using SM-CLP
. . . . . . . . . . . . . . . . . . . 282
17 Using the WS-MAN Interface . . . . . . . . 283
WS-Management Features . . . . . . . . . . . . . . 283
Supported CIM Profiles
. . . . . . . . . . . . . . . . 284
18 Deploying Your Operating
System Using iVMCLI
Before You Begin. . . . . . . . . . . . . . . . . . . . 287
Remote System Requirements
Network Requirements
Creating a Bootable Image File
Creating an Image File for Linux Systems
Creating an Image File for Windows Systems
Preparing for Deployment
Configuring the Remote Systems
Deploying the Operating System
. . . . . . . . . . . . . . . . . . . . . . 288
. . . . . . . . . . . . . . 287
. . . . . . . . . . . . . . 287
. . . . . . . . . . . . . . . . 288
. . . . . . . . . . . . . . . 288
. . . . . . . . . . 287
. . . . . . . . . . . . 288
. . . . . . . . . 288
. . . . . . . . . . . . 289
16 Contents
Using the Virtual Media Command Line Interface Utility
Installing the iVMCLI Utility
Command Line Options
iVMCLI Parameters
. . . . . . . . . . . . . . . . . . . 290
. . . . . . . . . . . . . 291
. . . . . . . . . . . . . . . 292
. . . . . . . . . . . . . . . . . 292
iVMCLI Operating System Shell Options
19 Using iDRAC6 Configuration
Utility
. . . . . . . . . . . . . . . . . . . . . . . . . . . 297
Overview . . . . . . . . . . . . . . . . . . . . . . . . . 297
. . . . . . 295
Starting iDRAC6 Configuration Utility
Using iDRAC6 Configuration Utility
iDRAC6 LAN
IPMI Over LAN
LAN Parameters
. . . . . . . . . . . . . . . . . . . . . 299
. . . . . . . . . . . . . . . . . . . 299
. . . . . . . . . . . . . . . . . . 300
Virtual Media Configuration
System Services
. . . . . . . . . . . . . . . . . . 304
LAN User Configuration
Reset to Default
. . . . . . . . . . . . . . . . . . . 306
System Event Log Menu
Exiting iDRAC6 Configuration Utility
. . . . . . . . . . 298
. . . . . . . . . . . 298
. . . . . . . . . . . . 303
. . . . . . . . . . . . . . 304
. . . . . . . . . . . . . . 307
. . . . . . . . 307
20 Recovering and Troubleshooting
the Managed System
Safety First – For You and Your System . . . . . . . . . 309
Trouble Indicators
LED Indicators
Hardware Trouble Indicators
Other Trouble Indicators
. . . . . . . . . . . . . . 309
. . . . . . . . . . . . . . . . . . . . 310
. . . . . . . . . . . . . . . . . . . 310
. . . . . . . . . . . . 311
. . . . . . . . . . . . . . 311
Contents 17
Problem Solving Tools . . . . . . . . . . . . . . . . . 312
Checking the System Health
Checking the System Event Log (SEL)
Checking the Post Codes
Viewing the Last System Crash Screen
. . . . . . . . . . . 312
. . . . . . 313
. . . . . . . . . . . . . 314
. . . . . . 314
Viewing the Most Recent Boot Sequences
. . . . . . . . . . . . . . . . . 315
Checking the Server Status Screen for Error Messages
Viewing iDRAC6 Log
Viewing System Information
. . . . . . . . . . . . . . . . 316
. . . . . . . . . . . . . . . 324
. . . . . . . . . . . 325
Identifying the Managed Server in the Chassis
Using the Diagnostics Console
Managing Power on a Remote System
. . . . . . . . . . . . . . . . . . . 326
. . . . . . . . . . 326
. . . . . . 327
Troubleshooting and Frequently Asked Questions
. . . . . . . . . . . . . . . . . . . . 329
A RACADM Subcommand Overview . . . . . 335
help . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
18 Contents
config
. . . . . . . . . . . . . . . . . . . . . . . . . . 336
getconfig
getssninfo
getsysinfo
. . . . . . . . . . . . . . . . . . . . . . . . 338
. . . . . . . . . . . . . . . . . . . . . . . 340
. . . . . . . . . . . . . . . . . . . . . . . . 342
getractime . . . . . . . . . . . . . . . . . . . . . . . 346
setniccfg
getniccfg
getsvctag
. . . . . . . . . . . . . . . . . . . . . . . . 347
. . . . . . . . . . . . . . . . . . . . . . . . 349
. . . . . . . . . . . . . . . . . . . . . . . . 350
racreset . . . . . . . . . . . . . . . . . . . . . . . . . 351
racresetcfg
serveraction
getraclog
clrraclog
getsel
clrsel
. . . . . . . . . . . . . . . . . . . . . . . . 352
. . . . . . . . . . . . . . . . . . . . . . . 352
. . . . . . . . . . . . . . . . . . . . . . . . . 353
. . . . . . . . . . . . . . . . . . . . . . . . . 355
. . . . . . . . . . . . . . . . . . . . . . . . . . . 355
. . . . . . . . . . . . . . . . . . . . . . . . . . . 357
gettracelog. . . . . . . . . . . . . . . . . . . . . . . . 357
sslcsrgen
sslcertupload
sslcertdownload
sslcertview
testemail
testtrap
vmdisconnect
. . . . . . . . . . . . . . . . . . . . . . . . . 359
. . . . . . . . . . . . . . . . . . . . . . 360
. . . . . . . . . . . . . . . . . . . . . 361
. . . . . . . . . . . . . . . . . . . . . . . . 362
. . . . . . . . . . . . . . . . . . . . . . . . . 364
. . . . . . . . . . . . . . . . . . . . . . . . . . 366
. . . . . . . . . . . . . . . . . . . . . . 367
clearasrscreen
localconredirdisable
. . . . . . . . . . . . . . . . . . . . . . 368
. . . . . . . . . . . . . . . . . . 368
fwupdate . . . . . . . . . . . . . . . . . . . . . . . . . 369
krbkeytabupload
. . . . . . . . . . . . . . . . . . . . . . . . . . 372
vmkey
version
. . . . . . . . . . . . . . . . . . . . . . . . . . 372
. . . . . . . . . . . . . . . . . . . . . 371
Contents 19
arp . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
coredump
coredumpdelete
ifconfig
netstat
ping
ping6
. . . . . . . . . . . . . . . . . . . . . . . . 373
. . . . . . . . . . . . . . . . . . . . 374
. . . . . . . . . . . . . . . . . . . . . . . . . 375
. . . . . . . . . . . . . . . . . . . . . . . . . 376
. . . . . . . . . . . . . . . . . . . . . . . . . . . 376
. . . . . . . . . . . . . . . . . . . . . . . . . . 377
racdump . . . . . . . . . . . . . . . . . . . . . . . . 377
traceroute
traceroute6
remoteimage
. . . . . . . . . . . . . . . . . . . . . . . 378
. . . . . . . . . . . . . . . . . . . . . . . 379
. . . . . . . . . . . . . . . . . . . . . . 380
B iDRAC6 Enterprise Property Database Group and Object Definitions
Displayable Characters . . . . . . . . . . . . . . . . 383
. . . . . . . . . . . . . . . . . . . . 383
20 Contents
idRacInfo
. . . . . . . . . . . . . . . . . . . . . . . . 384
idRacProductInfo (Read Only)
idRacDescriptionInfo (Read Only)
idRacVersionInfo (Read Only)
idRacBuildInfo (Read Only)
idRacName (Read Only)
idRacType (Read Only)
. . . . . . . . . . 384
. . . . . . . . 384
. . . . . . . . . . . 384
. . . . . . . . . . . . 385
. . . . . . . . . . . . . 385
. . . . . . . . . . . . . . 385
cfgOobSnmp . . . . . . . . . . . . . . . . . . . . . . . 386
cfgOobSnmpAgentCommunity (Read/Write)
cfgOobSnmpAgentEnable (Read/Write)
. . . . . . . . . . . . . . . . . . . . 386
. . . . . . 386
cfgLanNetworking
. . . . . . . . . . . . . . . . . . . . 387
cfgNicIPv4Enable (Read/Write)
cfgDNSDomainNameFromDHCP (Read/Write)
. . . . . . . . . . . . . . . . . . . . 387
cfgDNSDomainName (Read/Write)
cfgDNSRacName (Read/Write)
cfgDNSRegisterRac (Read/Write)
cfgDNSServersFromDHCP (Read/Write)
cfgDNSServer1 (Read/Write)
cfgDNSServer2 (Read/Write)
cfgNicEnable (Read/Write)
. . . . . . . . . . . . . 390
cfgNicIpAddress (Read/Write)
cfgNicNetmask (Read/Write)
cfgNicGateway (Read/Write)
cfgNicUseDhcp (Read/Write)
cfgNicMacAddress (Read Only)
cfgNicVLanEnable (Read Only)
cfgNicVLanID (Read Only)
. . . . . . . . . . . . . 393
cfgNicVLanPriority (Read Only)
cfgIPv6URL
. . . . . . . . . . . . . . . . . . . . . . . . 394
cfgIPv6URLstring (Read Only)
. . . . . . . . . . 387
. . . . . . . . 388
. . . . . . . . . . 388
. . . . . . . . . 389
. . . . . . 389
. . . . . . . . . . . . 389
. . . . . . . . . . . . 390
. . . . . . . . . . . 391
. . . . . . . . . . . . 391
. . . . . . . . . . . . 391
. . . . . . . . . . . 392
. . . . . . . . . . 392
. . . . . . . . . . . 393
. . . . . . . . . . 393
. . . . . . . . . . . 394
cfgIPv6LanNetworking
cfgIPv6Enable
. . . . . . . . . . . . . . . . . 394
. . . . . . . . . . . . . . . . . . . 394
cfgIPv6Address1 (Read/Write)
cfgIPv6Gateway (Read/Write)
cfgIPv6PrefixLength (Read/Write)
cfgIPv6AutoConfig (Read/Write)
cfgIPv6LinkLocalAddress (Read Only)
. . . . . . . . . . . 395
. . . . . . . . . . . 395
. . . . . . . . . 395
. . . . . . . . . . 396
. . . . . . . 396
Contents 21
cfgIPv6Address2 (Read Only). . . . . . . . . . . 396
cfgIPv6DNSServersFromDHCP6 (Read/Write)
cfgIPv6DNSServer1 (Read/Write)
cfgIPv6DNSServer2 (Read/Write)
cfgIPv6DNSServer2 (Read/Write)
cfgIPv6Addr2PrefixLength (Read Only)
. . . . . . . . . . . . . . . . . . . 397
. . . . . . . . 397
. . . . . . . . 397
. . . . . . . . 398
. . . . . . 398
cfgIPv6LinkLockPrefixLength (Read Only)
. . . . . . . . . . . . . . . . . . . . 398
cfgTotalnumberofextended IP (Read/Write)
cfgIPv6Addr3PrefixLength (Read Only)
cfgIPv6Addr3Length (Read Only)
cfgIPv6Address3 (Read Only)
cfgIPv6Addr4PrefixLength (Read Only)
cfgIPv6Addr4Length (Read Only)
cfgIPv6Address4 (Read Only)
cfgIPv6Addr5PrefixLength (Read Only)
cfgIPv6Addr5Length (Read Only)
cfgIPv6Address5 (Read Only)
cfgIPv6Addr6PrefixLength (Read Only)
cfgIPv6Addr6Length (Read Only)
cfgIPv6Address6 (Read Only)
cfgIPv6Addr7PrefixLength (Read Only)
cfgIPv6Addr7Length (Read Only)
cfgIPv6Address7 (Read Only)
cfgIPv6Addr8PrefixLength (Read Only)
cfgIPv6Addr8Length (Read Only)
cfgIPv6Address8 (Read Only)
cfgIPv6Addr9PrefixLength (Read Only)
cfgIPv6Addr9Length (Read Only)
cfgIPv6Address9 (Read Only)
cfgIPv6Addr10PrefixLength (Read Only)
cfgIPv6Addr10Length (Read Only)
. . . . . . . . . . . . . . . . . . . 398
. . . . . . 399
. . . . . . . . . 399
. . . . . . . . . . . 399
. . . . . . 399
. . . . . . . . . 400
. . . . . . . . . . . 400
. . . . . . 400
. . . . . . . . . 400
. . . . . . . . . . . 400
. . . . . . 401
. . . . . . . . . 401
. . . . . . . . . . . 401
. . . . . . 401
. . . . . . . . . 402
. . . . . . . . . . . 402
. . . . . . 402
. . . . . . . . . 402
. . . . . . . . . . . 402
. . . . . . 403
. . . . . . . . . 403
. . . . . . . . . . . 403
. . . . . 403
. . . . . . . . 404
22 Contents
cfgIPv6Address10 (Read Only) . . . . . . . . . . . 404
cfgIPv6Addr11PrefixLength (Read Only)
cfgIPv6Addr11Length (Read Only)
cfgIPv6Address11 (Read Only)
. . . . . . . . . . . 404
cfgIPv6Addr12PrefixLength (Read Only)
cfgIPv6Addr12Length (Read Only)
cfgIPv6Address12 (Read Only)
. . . . . . . . . . . 405
cfgIPv6Addr13PrefixLength (Read Only)
cfgIPv6Addr13Length (Read Only)
cfgIPv6Address13 (Read Only)
. . . . . . . . . . . 406
cfgIPv6Addr14PrefixLength (Read Only)
cfgIPv6Addr14Length (Read Only)
cfgIPv6Address14 (Read Only)
. . . . . . . . . . . 406
cfgIPv6Addr15PrefixLength (Read Only)
cfgIPv6Addr15Length (Read Only)
cfgIPv6Address15 (Read Only)
. . . . . . . . . . . 407
. . . . . . 404
. . . . . . . . . 404
. . . . . . 405
. . . . . . . . . 405
. . . . . . 405
. . . . . . . . . 406
. . . . . . 406
. . . . . . . . . 406
. . . . . . 407
. . . . . . . . . 407
cfgUserAdmin
cfgUserAdminIndex (Read Only)
. . . . . . . . . . . . . . . . . . . . . . 407
. . . . . . . . . . 408
cfgUserAdminIpmiLanPrivilege (Read/Write)
cfgUserAdminPrivilege (Read/Write)
cfgUserAdminUserName (Read/Write)
cfgUserAdminPassword (Write Only)
cfgUserAdminEnable (Read/Write)
cfgUserAdminSolEnable (Read/Write)
. . . . . . . . . . . . . . . . . . . . 408
. . . . . . . 408
. . . . . . 410
. . . . . . . 410
. . . . . . . . . 411
. . . . . . . 411
cfgEmailAlert . . . . . . . . . . . . . . . . . . . . . . 411
cfgEmailAlertIndex (Read Only)
cfgEmailAlertEnable (Read/Write)
cfgEmailAlertAddress (Read/Write)
cfgEmailAlertCustomMsg (Read/Write)
. . . . . . . . . . 411
. . . . . . . . . 412
. . . . . . . . 412
. . . . . . 412
Contents 23
cfgSessionManagement . . . . . . . . . . . . . . . . 413
cfgSsnMgtConsRedirMaxSessions (Read/Write)
. . . . . . . . . . . . . . . . . . . 413
cfgSsnMgtWebserverTimeout (Read/Write)
cfgSsnMgtSshIdleTimeout (Read/Write)
cfgSsnMgtTelnetTimeout (Read/Write)
. . . . . . . . . . . . . . . . . . . 413
. . . . . 414
. . . . . . 414
cfgSerial
cfgRemoteHosts
. . . . . . . . . . . . . . . . . . . . . . . . 415
cfgSerialSshEnable (Read/Write)
cfgSerialTelnetEnable (Read/Write)
. . . . . . . . . . . . . . . . . . . . 416
. . . . . . . . . 415
. . . . . . . 416
cfgRhostsSmtpServerIpAddr (Read/Write)
. . . . . . . . . . . . . . . . . . . 416
cfgRhostsFwUpdateTftpEnable (Read/Write)
cfgRhostsFwUpdateIpAddr (Read/Write)
cfgRhostsFwUpdatePath (Read/Write)
cfgRhostsSyslogEnable (Read/Write)
cfgRhostsSyslogPort (Read/Write)
cfgRhostsSyslogServer1 (Read/Write)
cfgRhostsSyslogServer2 (Read/Write)
cfgRhostsSyslogServer3 (Read/Write)
cfgUserDomain
cfgUserDomainIndex (Read Only)
cfgUserDomainName (Read/Write)
. . . . . . . . . . . . . . . . . . . 416
. . . . . 417
. . . . . . 417
. . . . . . . 418
. . . . . . . . 418
. . . . . . 418
. . . . . . 419
. . . . . . 419
. . . . . . . . . . . . . . . . . . . . . 419
. . . . . . . . 419
. . . . . . . 420
cfgServerPower . . . . . . . . . . . . . . . . . . . . 420
cfgServerPowerStatus (Read Only)
. . . . . . . 420
cfgServerPowerServerAllocation (Read Only)
. . . . . . . . . . . . . . . . . . . . 420
cfgServerPowerActualPowerConsumption (Read Only)
. . . . . . . . . . . . . . . . . . . . 421
24 Contents
cfgServerPowerPeakPowerConsumption (Read Only)
. . . . . . . . . . . . . . . . . . . . . 421
cfgServerPowerPeakPowerTimestamp (Read Only)
. . . . . . . . . . . . . . . . . . . . . 421
cfgServerPowerConsumptionClear (Write Only)
. . . . . . . . . . . . . . . . . . . . . 422
cfgServerPowerCapWatts (Read Only)
cfgServerPowerCapBtuhr (Read Only)
. . . . . . . 422
cfgServerPowerCapPercent (Read Only)
. . . . . . 422
. . . . . 423
cfgRacTuning
. . . . . . . . . . . . . . . . . . . . . . 423
cfgRacTuneHttpPort (Read/Write)
cfgRacTuneHttpsPort (Read/Write)
cfgRacTuneIpRangeEnable
cfgRacTuneIpRangeAddr
cfgRacTuneIpRangeMask
cfgRacTuneIpBlkEnable
cfgRacTuneIpBlkFailCount
cfgRacTuneIpBlkFailWindow
cfgRacTuneIpBlkPenaltyTime
. . . . . . . . . . . . . 424
. . . . . . . . . . . . . . 424
. . . . . . . . . . . . . 425
. . . . . . . . . . . . . . 425
. . . . . . . . . . . . . 425
. . . . . . . . . . . . 426
. . . . . . . . . . . 426
cfgRacTuneSshPort (Read/Write)
cfgRacTuneConRedirEnable (Read/Write)
cfgRacTuneTelnetPort (Read/Write)
cfgRacTuneConRedirEncryptEnable (Read/Write)
. . . . . . . . . . . . . . . . . . . . 427
cfgRacTuneConRedirPort (Read/Write)
cfgRacTuneConRedirVideoPort (Read/Write)
. . . . . . . . . . . . . . . . . . . . 428
cfgRacTuneAsrEnable (Read/Write)
cfgRacTuneWebserverEnable (Read/Write)
cfgRacTuneLocalServerVideo (Read/Write)
cfgRacTuneDaylightOffset (Read/Write)
cfgRacTuneTimezoneOffset (Read/Write)
cfgRacTuneLocalConfigDisable (Read/Write)
. . . . . . . . . . . . . . . . . . . . 430
. . . . . . . . . 423
. . . . . . . . 424
. . . . . . . . . 426
. . . . . 427
. . . . . . . . 427
. . . . . . 428
. . . . . . . . 428
. . . . 429
. . . . 429
. . . . . . 429
. . . . . 430
Contents 25
ifcRacManagedNodeOs . . . . . . . . . . . . . . . . 431
ifcRacMnOsHostname (Read Only)
ifcRacMnOsOsName (Read Only)
. . . . . . . . 431
. . . . . . . . 431
cfgRacSecurity
. . . . . . . . . . . . . . . . . . . . . 432
cfgSecCsrCommonName (Read/Write)
cfgSecCsrOrganizationName (Read/Write)
. . . . . . . . . . . . . . . . . . . 432
cfgSecCsrOrganizationUnit (Read/Write)
cfgSecCsrLocalityName (Read/Write)
cfgSecCsrStateName (Read/Write)
cfgSecCsrCountryCode (Read/Write)
cfgSecCsrEmailAddr (Read/Write)
cfgSecCsrKeySize (Read/Write)
cfgRacVirtual
. . . . . . . . . . . . . . . . . . . . . . 434
cfgVirMediaAttached (Read/Write)
cfgVirMediaBootOnce (Read/Write)
cfgVirMediaKeyEnable (Read/Write)
cfgVirtualFloppyEmulation (Read/Write)
cfgIpmiLan
. . . . . . . . . . . . . . . . . . . . . . . 436
cfgIpmiLanEnable (Read/Write)
cfgIpmiLanPrivLimit (Read/Write)
cfgIpmiLanAlertEnable (Read/Write)
cfgIpmiEncryptionKey (Read/Write)
cfgIpmiPetCommunityName (Read/Write)
. . . . . . 432
. . . . 432
. . . . . . 433
. . . . . . . 433
. . . . . . 433
. . . . . . . . 434
. . . . . . . . . 434
. . . . . . . 434
. . . . . . . 435
. . . . . . . 435
. . . . . 436
. . . . . . . . . 436
. . . . . . . . 437
. . . . . . . 437
. . . . . . . 437
. . . . 438
26 Contents
cfgIpmiPetIpv6
. . . . . . . . . . . . . . . . . . . . . 438
cfgIpmiPetIPv6Index (Read Only)
cfgIpmiPetIPv6AlertDestIpAddr
cfgIpmiPetIPv6AlertEnable (Read/Write)
. . . . . . . . . 438
. . . . . . . . . 439
. . . . . 439
cfgIpmiPef . . . . . . . . . . . . . . . . . . . . . . . . 439
cfgIpmiPefName (Read Only)
cfgIpmiPefIndex (Read/Write)
cfgIpmiPefAction (Read/Write)
cfgIpmiPefEnable (Read/Write)
. . . . . . . . . . . . 439
. . . . . . . . . . . 440
. . . . . . . . . . . 440
. . . . . . . . . . 441
cfgIpmiPet
. . . . . . . . . . . . . . . . . . . . . . . . 441
cfgIpmiPetIndex (Read Only)
. . . . . . . . . . . . 441
cfgIpmiPetAlertDestIpAddr (Read/Write)
cfgIpmiPetAlertEnable (Read/Write)
. . . . . . . . 442
. . . . . 441
cfgSmartCard . . . . . . . . . . . . . . . . . . . . . . 442
cfgSmartCardLogonEnable (Read/Write)
cfgSmartCardCRLEnable (Read/Write)
cfgActiveDirectory
. . . . . . . . . . . . . . . . . . . . 443
cfgADSSOEnable (Read/Write)
cfgADRacDomain (Read/Write)
cfgADRacName (Read/Write)
cfgADEnable (Read/Write)
. . . . . . . . . . . . . 444
cfgADAuthTimeout (Read/Write)
cfgADDomainController1 (Read/Write)
cfgADDomainController2 (Read/Write)
cfgADDomainController3 (Read/Write)
cfgADGlobalCatalog1 (Read/Write)
cfgADGlobalCatalog2 (Read/Write)
cfgADGlobalCatalog3 (Read/Write)
cfgADType (Read/Write)
. . . . . . . . . . . . . . 447
cfgADCertValidationEnable (Read/Write)
. . . . . . . . . . . 443
. . . . . . . . . . 443
. . . . . . . . . . . 444
. . . . . 442
. . . . . . . 443
. . . . . . . . . . 444
. . . . . . . 445
. . . . . . 445
. . . . . . . 446
. . . . . . . . 446
. . . . . . . . 446
. . . . . . . . 447
. . . . . 447
cfgStandardSchema
. . . . . . . . . . . . . . . . . . . 448
cfgSSADRoleGroupIndex (Read Only)
cfgSSADRoleGroupName (Read/Write)
cfgSSADRoleGroupDomain (Read/Write)
cfgSSADRoleGroupPrivilege (Read/Write)
. . . . . . . 448
. . . . . . 448
. . . . . 448
. . . . . 449
Contents 27
cfgIpmiSol . . . . . . . . . . . . . . . . . . . . . . . 450
cfgIpmiSolEnable (Read/Write)
cfgIpmiSolBaudRate (Read/Write)
cfgIpmiSolMinPrivilege (Read/Write)
. . . . . . . . . . 450
. . . . . . . . 450
. . . . . . 450
cfgIpmiSolAccumulateInterval (Read/Write)
cfgIpmiSolSendThreshold (Read/Write)
. . . . . . . . . . . . . . . . . . . 451
. . . . . 451
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453
Index
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463
28 Contents

iDRAC6 Enterprise Overview

The Integrated Dell™ Remote Access Controller (iDRAC6) Enterprise is a systems management hardware and software solution that provides remote management capabilities, crashed system recovery, and power control functions for Dell PowerEdge™ systems.
iDRAC6 uses an integrated System-on-Chip microprocessor for the remote monitor/control system, and co-exists on the system board with the managed PowerEdge server. The server operating system executes application programs; iDRAC6 monitors and manages the server’s environment and state outside of the operating system.
iDRAC6 can be configured to send an e-mail or Simple Network Management Protocol (SNMP) trap alert for warnings or errors. To help you diagnose the probable cause of a system crash, iDRAC6 can log event data and capture an image of the screen when it detects that the system has crashed.
Managed servers are installed in a Dell M1000e system enclosure (chassis) with modular power supplies, cooling fans, and a chassis management controller (CMC). CMC monitors and manages all components installed in the chassis. A redundant CMC can be added to provide hot failover if the primary CMC fails. The chassis provides access to iDRAC6 devices through its LCD display, local console connections, and its Web interface. Each blade in a chassis has an iDRAC6. A total of 16 blades can be installed in the M1000e.
All network connections to iDRAC6 are routed through CMC network interfaces (CMC RJ45 connection port labeled "Gb"). CMC routes traffic to the blades management network is outside of the server’s data path and outside of the operating system’s control—that is, it is out-of-band. The managed server inband network interfaces are accessed through I/O modules (IOMs) installed in the chassis.
' iDRAC6 devices through a private, internal network. This private
's
iDRAC6 Enterprise Overview 29
NOTE: Dell recommends that you isolate or separate the chassis management
network, used by iDRAC6 and CMC, from your production network(s). Mixing management and production or application network traffic may cause congestion or network saturation resulting in CMC and iDRAC6 communication delays. The delays may cause unpredictable chassis behavior such as CMC displays that iDRAC6 is offline even though it is operating properly. This could cause other unpredictable behavior.
The iDRAC6 network interface is disabled by default. It must be configured before iDRAC6 is accessible. After iDRAC6 is enabled and configured on the network, it can be accessed through its assigned IP address with iDRAC6 Web interface, Telnet or SSH, and supported network management protocols, such as Intelligent Platform Management Interface (IPMI).

IPv6 Ready Logo Certification

The IPv6 Ready Logo Committee's mission is to define the test specifications for IPv6 conformance and interoperability testing, to provide access to self
-test tools, and to deliver the IPv6 Ready Logo.
iDRAC6 is Phase 02-C-000380. For information on the IPv6 Ready Logo Program, see http://www.ipv6ready.org/.
-2 IPv6 Ready Logo certified and the Logo ID is

iDRAC6 Security Features

iDRAC6 provides the following security features:
User authentication through Microsoft Active Directory (optional) or locally administered user IDs and passwords
Two-factor authentication, which is provided by the Smart–Card logon feature. The two-factor authentication is based on what the users Smart– Card) and what they
Role-based authorization, which enables an administrator to configure specific privileges for each user
User ID and password configuration through the Web interface, SM-CLP, and local RACADM
SM-CLP and Web interfaces, which support 128-bit and 40-bit encryption (for countries where 128 bit is not acceptable), using the SSL 3.0 standard
know
(the PIN)
have
(the
30 iDRAC6 Enterprise Overview
Loading...
+ 442 hidden pages