Related Documentation....................................................................................................................................11
Physical Disk Power Management.........................................................................................................................13
Configured Spin Down Delay........................................................................................................................... 13
Types Of Virtual Disk Initialization.......................................................................................................................... 14
Background Initialization Of Virtual Disks........................................................................................................14
Full Initialization Of Virtual Disks......................................................................................................................14
Fast Initialization Of Virtual Disks.....................................................................................................................14
Disk Roaming.......................................................................................................................................................... 15
Using Disk Roaming..........................................................................................................................................15
Virtual Disk Migration............................................................................................................................................. 16
Virtual Disk Write Cache Policies...........................................................................................................................17
Write-Back And Write-Through.......................................................................................................................17
Conditions Under Which Write-Back Is Employed.......................................................................................... 17
Conditions Under Which Forced Write-Back With No Battery Is Employed................................................... 17
Virtual Disk Read Cache Policies............................................................................................................................18
Reconfiguration Of Virtual Disks.............................................................................................................................18
The SMART Feature................................................................................................................................................20
Automatic Replace Member With Predicted Failure....................................................................................... 20
Redundant Path Support (For PERC H810 Only)......................................................................................................21
Physical Disk Failure Detection.............................................................................................................................. 22
Using Persistent Hot Spare Slots............................................................................................................................22
Physical Disk Hot Swapping...................................................................................................................................22
Using Replace Member And Revertible Hot Spares...............................................................................................22
TLC Time Frame................................................................................................................................................23
Conditions For Replacing The Battery..............................................................................................................23
3 Deploying The PERC Card........................................................................................................25
Removing The PERC Controller...............................................................................................................................25
Installing The PERC Controller................................................................................................................................27
Support For Internal Multiple Controllers...............................................................................................................28
Setting Up Redundant Path Support On The PERC H810 Adapter..........................................................................28
Reverting To Single Path Support From Redundant Path Support For PERC H810.................................................28
Pre-Installation Requirements For Windows Driver Installation............................................................................31
Creating The Device Driver Media For Windows Driver Installation..................................................................... 31
Downloading Drivers From The Dell Systems Service And Diagnostic Tools Media For Windows................31
Downloading Drivers From The Dell Support Website For Windows.............................................................. 32
Installing Driver During a Windows Server 2008/2008 R2 Installation............................................................. 32
Installing Windows Server 2008/2008 R2 For A New RAID Controller............................................................. 32
Updating Existing Windows Server 2008 Or Windows Server 2008 R2............................................................33
Updating The Linux Driver...................................................................................................................................... 33
Installing Or Updating The RPM Driver Package With DKMS Support........................................................... 34
Installing Or Updating The RPM Driver Package With KMOD Support........................................................... 34
Installing Or Updating The RPM Driver Package With KMP Support..............................................................34
5 Management Applications For PERC Cards......................................................................... 37
Entering The BIOS Configuration Utility........................................................................................................... 37
Exiting The Configuration Utility....................................................................................................................... 38
Menu Navigation Controls............................................................................................................................... 38
Setting Up Virtual Disks....................................................................................................................................39
Virtual Disk Management....................................................................................................................................... 41
Selecting Virtual Disk Parameters................................................................................................................... 42
Converting Physical Disk To RAID Capable For PERC H310.............................................................................42
Converting Physical Disk To Non-RAID For PERC H310...................................................................................43
Checking Data Consistency............................................................................................................................. 43
Running A Data Consistency Check.................................................................................................................43
Importing Or Clearing Foreign Configurations Using The VD Mgmt Menu......................................................44
Importing Or Clearing Foreign Configurations Using The Foreign Configuration View Screen.......................44
Deleting Disk Groups........................................................................................................................................48
Clearing The Configuration...............................................................................................................................48
BIOS Configuration Utility Menu Options............................................................................................................... 49
Virtual Disk Management (VD Mgmt)...............................................................................................................49
Virtual Disk Actions..........................................................................................................................................51
Physical Disk Management (PD Mgmt)........................................................................................................... 52
Physical Disk Actions.......................................................................................................................................52
Physical Disk Management.................................................................................................................................... 54
Setting LED Blinking......................................................................................................................................... 54
Creating Global Hot Spares..............................................................................................................................55
Removing Global Or Dedicated Hot Spares..................................................................................................... 55
Replacing An Online Physical Disk.................................................................................................................. 55
Restrictions and Limitations.............................................................................................................................56
Enabling Boot Support For A BIOS-Enabled Controller....................................................................................57
Enabling BIOS Stop On Error............................................................................................................................57
Enabling Auto Import........................................................................................................................................57
Disabling Auto Import.......................................................................................................................................58
Virtual Disk Management.................................................................................................................................60
Physical Disk Management Menu................................................................................................................... 60
CacheCade Virtual Disk Characteristics.................................................................................................................61
Configuring And Managing CacheCade Virtual Disks............................................................................................61
CacheCade Virtual Disk Management............................................................................................................. 62
Security Key Management In The BIOS Configuration Utility................................................................................ 65
Local Key Management (LKM).........................................................................................................................65
Creating A Security Key................................................................................................................................... 66
Changing The Security Key.............................................................................................................................. 66
Deleting A Security Key................................................................................................................................... 67
Failure to Select Or Configure Non Self-Encrypting Disks (Non-SED).............................................................69
Failure To Delete Security Key.........................................................................................................................70
Failure To Instant Secure Erase Task On Physical Disks.................................................................................70
Extra Enclosure Error Message....................................................................................................................... 71
Cache Data Lost Error Message...................................................................................................................... 71
Missing Disks In Virtual Disk Error Message...................................................................................................72
Previous Configuration Of Disks Removed Error Message..............................................................................72
Configured Disks Removed Or Not Accessible Error Message.......................................................................77
Battery Discharged Or Disconnected Error Message..................................................................................... 77
Degraded State Of Virtual Disks............................................................................................................................. 77
General Issues........................................................................................................................................................78
PERC Card Has Yellow Bang In Device Manager............................................................................................ 78
PERC Card Not Seen In Device Manager........................................................................................................ 78
No Hard Drives Found Error Message During Microsoft Windows Server 2003 Installation..........................78
Physical Disk Issues............................................................................................................................................... 79
Physical Disk In Failed State............................................................................................................................ 79
Unable to Rebuild A Fault Tolerant Virtual Disk............................................................................................... 79
Fatal Error Or Data Corruption Reported..........................................................................................................79
Physical Disk Displayed As Blocked................................................................................................................79
Multiple Disks Become Inaccessible...............................................................................................................80
Rebuilding A Failed Physical Disk.................................................................................................................... 80
Virtual Disk Fails During Rebuild Using A Global Hot Spare............................................................................ 80
Virtual Disk Fails During Rebuild Using A Dedicated Hot Spare......................................................................80
Physical Disk Fails During Reconstruction On Redundant Virtual Disk........................................................... 81
Virtual Disk Fails Rebuild Using A Dedicated Hot Spare..................................................................................81
Physical Disk Takes A Long Time To Rebuild...................................................................................................81
Smart Error Detected On A Physical Disk In A Redundant Virtual Disk...........................................................81
Smart Error Detected On A Physical Disk In A Non-Redundant Virtual Disk...................................................82
Replace Member Errors..........................................................................................................................................82
Source Disk Fails During Replace Member Operation.................................................................................... 82
Target Disk Fails...............................................................................................................................................82
General Disk Fails.............................................................................................................................................82
Linux Operating System Errors............................................................................................................................... 82
Virtual Disk Policy Is Assumed As Write-Through Error Message..................................................................82
Driver Does Not Auto-Build Into New Kernel.................................................................................................. 83
Unable To Register SCSI Device Error Message.............................................................................................83
Disk Carrier LED Indicators.....................................................................................................................................84
Summary Of RAID Levels........................................................................................................................................85
Disk Striping..................................................................................................................................................... 85
Disk Mirroring...................................................................................................................................................86
The Dell PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 family of storage controller cards has the
following characteristics:
•Complies with serial-attached SCSI (SAS) 2.0 providing up to 6 Gb/sec throughput.
•Supports Dell-qualified serial-attached SCSI (SAS) hard drives, SATA hard drives, and solid-state drives (SSDs).
NOTE: Mixing SAS and SATA drives within a virtual disk is not supported. Also, mixing hard drives and
SSDs within a virtual disk is not supported.
NOTE: Mixing disks of different speeds (7,200 rpm, 10,000 rpm, or 15,000 rpm) and bandwidth (3 Gbps or 6
Gbps) PCIe while maintaining the same drive type (SAS or SATA) and technology (HDD or SSD) is
supported.
•Offers RAID control capabilities which include support for RAID levels 0, 1, 5, 6, 10, 50, and 60.
NOTE: PERC H310 supports RAID 5 with limited performance and does not support RAID 6 and RAID 60.
•Provides reliability, high performance, and fault-tolerant disk subsystem management.
•Offers Non-RAID support for direct access to disk drives (PERC H310 only).
NOTE: Operating systems can directly access Non-RAID hard drives. A Non-RAID hard drive is not faulttolerant and cannot be recovered if it fails. Only the PERC H310 controller allows configuration of disk
drives as Non-RAID.
The following table compares the hardware configurations for the PERC H310, H710, H710P, and H810 cards.
Table 1. PERC H310, H710, H710P, and H810 Cards Hardware Configurations
The PERC H310, H710, and H710P cards support the following operating systems:
•Microsoft Windows Server 2012
•Microsoft Windows Server 2008 including Hyper-V virtualization
•Microsoft Windows Server 2008 R2 and later
•Red Hat Enterprise Linux version 5.8 and later (32-bit and 64-bit)
•Red Hat Enterprise Linux version 6.2 and later (64-bit)
•SUSE Linux Enterprise Server version 10 SP4 (64-bit)
•SUSE Linux Enterprise Server version 11 SP2 (64-bit)
•VMware ESX 4.1 and ESXi 4.1 Update 2 and later
•VMware ESXi 5.0 and later
NOTE: For the latest list of supported operating systems and driver installation instructions, see the system
documentation at dell.com/support/manuals. For specific operating system service pack requirements, see
the Drivers and Downloads section at dell.com/support/manuals.
Getting Help
10
Contacting Dell
NOTE: Dell provides several online and telephone-based support and service options. If you do not have an active
Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product
catalog. Availability varies by country and product, and some services may not be available in your area.
To contact Dell for sales, technical support, or customer-service issues:
1.Go to dell.com/contactdell.
2.Select your country or region from the interactive world map.
When you select a region, the countries for the selected regions are displayed.
3.Select the appropriate language under the country of your choice.
4.Select your business segment.
The main support page for the selected business segment is displayed.
5.Select the appropriate option depending on your requirement.
Related Documentation
NOTE: For all storage controllers and PCIe SSD documents, go to dell.com/support/manuals, then, Choose from a
list of all Dell products
NOTE: For all Dell OpenManage documents, see dell.com/support/manuals, then, Choose from a list of all Dell
products → Software, Electronics & Peripherals → Software → Enterprise System Management .
NOTE: For all operating system documents, go to dell.com/support/manuals, then, Choose from a list of all Dell
products → Software, Electronics & Peripherals → Software → Operating System .
→ Servers, Storage & Networking → Dell Adapters .
NOTE: For all PowerEdge and PowerVault documentation, go to dell.com/support/manuals and enter the system
service tag to get your system documentation.
If you have feedback for this document, write to documentation_feedback@dell.com. Alternatively, you can click on the
Feedback link in any of the Dell documentation pages, fill up the form, and click Submit to send your feedback.
11
12
2
Features
Some of the features discussed for PowerEdge RAID Controller (PERC) H310, H710, H710P, and H810 cards are:
•Physical Disk Power Management
•Types of Virtual Disk Initialization
•Consistency Checks
•Disk Roaming
•Fast Path
•Virtual Disk Migration
•Reconfiguration Of Virtual Disks
•Fault Tolerance
•Patrol Read
Physical Disk Power Management
Physical disk power management is a power saving feature of the PERC H310, H710, H710P, and H810 cards. The feature
allows disks to be spun down based on disk configuration and I/O activity. The feature is supported on all rotating SAS
and SATA disks and includes unconfigured, configured and hot-spare disks. The physical disk power management
feature is disabled by default. The feature can be enabled in the Dell Open Manage Storage Management application
using the Unified Extensible Firmware Interface (UEFI) RAID Configuration utility. For more information, see the Dell
OpenManage documentation at dell.com/support/manuals.
There are four power saving modes available:
No Power
Savings (
mode
Balanced Power
Savings
Maximum Power
Savings
Customized
Power Savings
default
)
All power savings features are disabled.
Spin down is enabled only for unconfigured and hot spare disks.
Spin down is enabled for configured, unconfigured and hot spare disks.
All power savings features are customizable. You can specify a Quality of Service window
during which the configured disks are excluded from spin-down.
Configured Spin Down Delay
NOTE: The Configured Spin Down Delay option is not applicable for the No Power Savings mode.
The amount of time to wait before spinning down disks can be set using Configured Spin Down Delay. The minimum
value of the timer is 30 minutes (default) and the maximum is one day. Disks are spun down automatically and spun up
when accessed. All disks are spun up on reboot.
13
NOTE: There is a delay to I/O operations when a configured disk is being spun up.
Types Of Virtual Disk Initialization
You can initialize the virtual disks as described in the following sections:
CAUTION: The initializing virtual disks task erases the files and file systems while keeping the virtual disk
configuration intact. Initializing a virtual disk destroys all data on the virtual disk.
NOTE: The initialization operations mentioned here are not applicable for Non-RAID disks.
Background Initialization Of Virtual Disks
Background Initialization (BGI) is an automated process that writes the parity or mirror data on newly created virtual
disks. BGI does not run on RAID 0 virtual disks. You can control the BGI rate in the Dell OpenManage storage
management application. Any change in the BGI rate does not take effect until the next BGI run.
NOTE: You cannot disable BGI permanently. If you cancel BGI, it automatically restarts within five minutes. For
information on stopping BGI, see the topic Stopping Background Initialization.
NOTE: Unlike full or fast initialization of virtual disks, background initialization does not clear data from the physical
disks.
NOTE: CC/BGI typically causes some loss in performance until the operation completes.
Consistency Check (CC) and BGI perform similar functions in that they both correct parity errors. However, CC reports
data inconsistencies through an event notification, but BGI does not. You can start CC manually, but not BGI.
Full Initialization Of Virtual Disks
Performing a full initialization on a virtual disk overwrites all blocks and destroys any data that previously existed on the
virtual disk. Full initialization of a virtual disk eliminates the need for the virtual disk to undergo a BGI. Full initialization
can be performed after the creation of a virtual disk.
During full initialization, the host is not able to access the virtual disk. You can start a full initialization on a virtual disk by
using the Slow Initialize option in the Dell OpenManage storage management application. For more information on using
the BIOS Configuration Utility to perform a full initialization, see the topic Initializing Virtual Disks.
NOTE: If the system reboots during a full initialization, the operation aborts and a BGI begins on the virtual disk.
Fast Initialization Of Virtual Disks
A fast initialization on a virtual disk overwrites the first and last 8 MB of the virtual disk, clearing any boot records or
partition information. The operation takes only 2–3 seconds to complete and is recommended when you are recreating
virtual disks. To perform a fast initialization using the BIOS Configuration Utility, see the topic Initializing Virtual Disks
Consistency Checks
Consistency Check (CC) is a background operation that verifies and corrects the mirror or parity data for fault tolerant
virtual disks. It is recommended that you periodically run a consistency check on virtual disks.
You can manually start a CC using the BIOS Configuration Utility or the Dell OpenManage storage management
application. You can schedule CC to run on virtual disks using a Dell OpenManage storage management application. To
start a CC using the BIOS Configuration Utility, see the topic Checking Data Consistency.
14
Disk Roaming
Disk roaming is moving the physical disks from one cable connection or backplane slot to another on the same
controller. The controller automatically recognizes the relocated physical disks and logically places them in the virtual
disks that are part of the disk group. You can perform disk roaming only when the system is turned off.
CAUTION: Do not attempt disk roaming during RAID level migration (RLM) or online capacity expansion (OCE). This
causes loss of the virtual disk.
Using Disk Roaming
Perform the following steps to use disk roaming:
1.Turn off the power to the system, physical disks, enclosures, and system components.
2.Disconnect power cables from the system.
3.Move the physical disks to desired positions on the backplane or the enclosure.
4.Perform a safety check. Make sure the physical disks are inserted properly.
5.Turn on the system.
The controller detects the RAID configuration from the configuration data on the physical disks.
FastPath
FastPath is a feature that improves application performance by delivering high I/O per second (IOPs). The Dell
PowerEdge RAID Controller (PERC) H710P and H810 cards support FastPath.
FastPath is a further enhancement of the Cut Through IO (CTIO) feature, introduced in PERC H700 and PERC H800, to
accelerate IO performance by reducing the IO processing overhead of the firmware. CTIO reduces the instruction count
required to process a given IO. It also ensures that the optimal IO code path is placed close to the processor to allow
faster access when processing the IO.
Under specific conditions with FastPath, the IO by-passes the controller cache and is committed directly to the physical
disk from the host memory, through the second core of the dual-core RAID-on-Chip (ROC) on the controller. FastPath
and CTIO are both ideal for random workloads with small blocks.
NOTE: The PERC H310 and PERC H710 do not support FastPath.
Both CTIO and FastPath provide enhanced performance benefits to SSD volumes, as they can fully capitalize on the
lower access times and latencies of these volumes.
FastPath provides IO performance benefits to rotational HDD-based volumes configured with Write Through and No
Read Ahead cache policies, specifically for read operations across all RAID levels and write operations for RAID 0.
Configuring FastPath-Capable Virtual Disks
All simple virtual disks configured with write cache policy Write Through and read cache policy No Read Ahead can
utilize FastPath. Only IO block sizes smaller than virtual disk’s stripe size are eligible for FastPath. In addition, there
should be no background operations (rebuild, initialization) running on the virtual disks. FastPath will not be used if these
operations are active.
NOTE: RAID 10, RAID 50, and RAID 60 virtual disks cannot use FastPath.
The following table summarizes the FastPath-eligibility of read and write IOs across the supported RAID levels.
15
Table 2. FastPath Eligibility Across Supported RAID Levels
RAID 0RAID 1RAID 5RAID 6
ReadYesYes
(Optimal and
Degraded)
WriteYesNoNoNo
In addition, FastPath-capable virtual disks are characterized by the following:
•The presence of CacheCade virtual disks on a controller disables the FastPath capability of all eligible HDD
virtual disks. Eligible SSD virtual disks are still FastPath-capable.
•Secured virtual disks are not FastPath-capable.
•The Physical Disk Power Management feature is not applicable to FastPath-capable virtual disks.
•The addition or removal of a redundant path does not affect the FastPath-capability of virtual disks.
Yes
(Optimal and Degraded)
Yes
(Optimal and Degraded)
Virtual Disk Migration
The PERC H710, H710P, and H810 cards support migration of virtual disks from one controller to another without taking
the target controller offline. The controller can import RAID virtual disks in optimal, degraded, or partially degraded
states. You cannot import a virtual disk that is in an offline state. Disk migration pointers:
•Supports migration of VDs from PERC H700 and H800 to PERC H710P and H810
•Supports migration of volumes created within H710, H710P, or H810
•Supports migration of volumes created on H310 to H710, H710P, or H810
•Does not support migration from H700 or H800 to H310
•Does not support migration from H710, H710P, or H810 to H310
•Does not support backward migration from H310, H710, H710P, H810 to H800 and H700
NOTE: The source controller must be offline prior to performing the disk migration.
NOTE: Disks cannot be migrated to older revisions or generations of the PERC cards.
NOTE: Non-RAID disks are supported only on the PERC H310 controller. Migration to any other PERC product is not
supported.
NOTE: Importing secured virtual disks is supported as long as the appropriate key (LKM) is supplied or configured.
When a controller detects a physical disk with an existing configuration, it flags the physical disk as foreign, and
generates an alert indicating that a foreign disk was detected.
CAUTION: Do not attempt disk roaming during RLM or OCE. This causes loss of the virtual disk.
Migrating Virtual Disks
To migrate virtual disks from PERC H700 or H800 to PERC H710, H710P, or H810:
1.Turn off the system.
2.Move the appropriate physical disks from the PERC H700 or H800 card to the PERC H710, H710P, or H810 card.
NOTE: If you are replacing your PERC H700 or H800 with a PERC H710, H710P, or H810 card, see the
Manual
of your system at support.dell.com/manuals.
16
Owner’s
3.Boot the system and import the foreign configuration that is detected. You can do one of the following:
– Press <F> to automatically import the foreign configuration.
– Enter the BIOS Configuration Utility and navigate to the Foreign Configuration View.
NOTE: For more information on accessing the BIOS Configuration Utility, see the topic Entering The BIOS
Configuration Utility.
NOTE: For more information on Foreign Configuration View, see the topic Foreign Configuration View.
4.Exit the BIOS Configuration Utility and reboot the system.
5.Ensure that all the latest drivers for the PERC H710, H710P, or H810 card (available at support.dell.com) are
installed.
For more information, see the topic Driver Installation.
Virtual Disk Write Cache Policies
NOTE: PERC H310 only supports Write-Through mode.
The write cache policy of a virtual disk determines how the controller handles writes to the virtual disk. Write-Back and
Write-Through are the two write cache policies that can be set on virtual disks individually.
All RAID volumes are presented as Write-Through to the operating system (Windows and Linux) independent of the
actual write cache policy of the virtual disk. The PERC cards manage the data in cache independently of the operating
system or any applications.
NOTE: Use the Dell OpenManage storage management application or the BIOS Configuration Utility to view and
manage virtual disk cache settings.
Write-Back And Write-Through
In Write-Through caching, the controller sends a data transfer completion signal to the host system when the disk
subsystem has received all the data in a transaction.
In Write-Back caching, the controller sends a data transfer completion signal to the host when the controller cache has
received all the data in a transaction. The controller then writes the cached data to the storage device in the
background.
The risk of using Write-Back cache is that the cached data can be lost if there is a power failure before it is written to
the storage device. This risk is mitigated by using a Non-Volatile Cache on the PERC H710, H710P or H810 card.
NOTE: The default cache setting for virtual disks is Write-Back caching.
NOTE: Certain data patterns and configurations perform better with a Write-Through cache policy.
Conditions Under Which Write-Back Is Employed
Write-Back caching is used under all conditions in which the battery is present and in good condition.
Conditions Under Which Forced Write-Back With No Battery Is Employed
CAUTION: It is recommended that you use a power backup system when forcing Write-Back to ensure there is no
loss of data if the system suddenly loses power.
Write-Back mode is available when you select Force WB with no battery. When Forced Write-Back mode is selected,
the virtual disk is in Write-Back mode even if the battery is not present.
17
Virtual Disk Read Cache Policies
The read policy of a virtual disk determines how the controller handles reads to that virtual disk. The read policies are:
•Always Read Ahead—Allows the controller to read sequentially ahead of requested data and to store the
additional data in cache memory, anticipating that the data is required soon. This speeds up reads for sequential
data, but there is little improvement when accessing random data.
•No Read Ahead—Disables the Read-Ahead capability.
•Adaptive Read Ahead—Begins using Read-Ahead if the two most recent disk accesses occurred in sequential
sectors. If the read requests are random, the controller reverts to No Read Ahead mode.
NOTE: The default read cache setting for virtual disks is Adaptive Read Ahead.
Reconfiguration Of Virtual Disks
An online virtual disk can be reconfigured in ways that expands its capacity and/or change its RAID level.
NOTE: Spanned virtual disks such as RAID 10, 50, and 60 cannot be reconfigured.
NOTE: Reconfiguring Virtual Disks typically impacts disk performance until the reconfiguration operation is
complete.
Online Capacity Expansion (OCE) can be done in two ways:
•If there is a single virtual disk in a disk group and free space is available, the virtual disk’s capacity can be
expanded within that free space.
•If a virtual disk is created and it does not use the maximum size of the disk group, free space is available.
Free space is also available when a disk group’s physical disks are replaced by larger disks using the Replace Member
feature. A virtual disk's capacity can also be expanded by performing an OCE operation to add more physical disks.
RAID Level Migration (RLM) refers to changing a virtual disk’s RAID level. Both RLM and OCE can be done at the same
time so that a virtual disk can simultaneously have its RAID level changed and its capacity increased. When a RLM/OCE
operation is complete, a reboot is not required. See the following table for a list of RLM/OCE possibilities. The source
RAID level column indicates the virtual disk RAID level before the RLM/OCE and the target RAID level column indicates
the RAID level after the operation has completed.
NOTE: If the controller already contains the maximum number of virtual disks, you cannot perform a RAID level
migration or capacity expansion on any virtual disk.
NOTE: The controller changes the write cache policy of all virtual disks undergoing a RLM/OCE to Write-Through
until the RLM/OCE is complete.
Table 3. RAID Level Migration
Source RAID
Level
RAID 0RAID 012 or moreYesIncreases
RAID 0RAID 112NoConverts non-
Target RAID Level Number of
Physical Disks
(Beginning)
Number of
Physical Disks
(End)
Capacity
Expansion
Possible
Description
capacity by
adding disks
redundant virtual
18
Source RAID
Level
RAID 0RAID 51 or more3 or moreYesAt least one disk
RAID 0RAID 61 or more4 or moreYesAt least two disks
RAID 1RAID 022 or moreYesRemoves
RAID 1RAID 523 or moreYesMaintains
Target RAID Level Number of
Physical Disks
(Beginning)
Number of
Physical Disks
(End)
Capacity
Expansion
Possible
Description
disk into a
mirrored virtual
disk by adding
one disk.
needs to be
added for
distributed parity
data.
need to be added
for dual
distributed parity
data.
redundancy while
increasing
capacity.
redundancy while
doubling capacity.
RAID 1RAID 624 or moreYesTwo disks
required to be
added for
distributed parity
data.
RAID 5RAID 03 or more3 or moreYesConverts to a non-
redundant virtual
disk and reclaims
disk space used
for distributed
parity data.
RAID 5RAID 53 or more4 or moreYesIncreases
capacity by
adding disks
RAID 5RAID 63 or more4 or moreYesAt least one disk
needs to be
added for dual
distributed parity
data.
RAID 6RAID 04 or more4 or moreYesConverts to a non-
redundant virtual
disk and reclaims
19
Source RAID
Level
RAID 6RAID 54 or more4 or moreYesRemoves one set
RAID 6RAID 64 or more5 or moreYesIncreases
NOTE: The total number of physical disks in a disk group cannot exceed 32. You cannot perform RAID level
migration and expansion on RAID levels 10, 50, and 60.
Target RAID Level Number of
Physical Disks
(Beginning)
Number of
Physical Disks
(End)
Capacity
Expansion
Possible
Description
disk space used
for distributed
parity data.
of parity data and
reclaims disk
space used for it.
capacity by
adding disks.
Fault Tolerance
The list of features of the PERC cards that provide fault tolerance to prevent data loss is as follows:
•Support for Self Monitoring and Reporting Technology (SMART)
•Support for Patrol Read
•Redundant path support (for PERC H810 only)
•Physical disk failure detection
•Physical disk rebuild using hot spares
•Controller Cache Preservation
•Battery and Non-Volatile Cache backup of controller cache to protect data
•Detection of batteries with low charge after boot up
The next sections describe some methods to achieve fault tolerance.
The SMART Feature
The SMART feature monitors certain physical aspects of all motors, heads, and physical disk electronics to help detect
predictable physical disk failures. SMART-compliant physical disks have attributes for which data can be monitored to
identify changes in values and determine whether the values are within threshold limits. Many mechanical and
electrical failures display some degradation in performance before failure.
A SMART failure is also referred to as a predicted failure. There are numerous factors that relate to predicted physical
disk failures, such as a bearing failure, a broken read/write head, and changes in spin-up rate. In addition, there are
factors related to read/write surface failure, such as seek error rate and excessive bad sectors.
NOTE: For detailed information on SCSI interface specifications, see t10.org and for detailed information on SATA
interface specifications, see t13.org.
Automatic Replace Member With Predicted Failure
A Replace Member operation can occur when there is a SMART predictive failure reporting on a physical disk in a
virtual disk. The automatic Replace Member is initiated when the first SMART error occurs on a physical disk that is part
20
of a virtual disk. The target disk needs to be a hot spare that qualifies as a rebuild disk. The physical disk with the
SMART error is marked as failed only after the successful completion of the Replace Member. This avoids putting the
array in degraded status.
If an automatic Replace Member occurs using a source disk that was originally a hot spare (that was used in a rebuild),
and a new disk added for the Replace Member operation as the target disk, the hot spare reverts to the hot spare state
after a successful Replace Member operation.
NOTE: To enable the automatic Replace Member, use the Dell OpenManage storage management application. For
more information on automatic Replace Member, see the topic Dell OpenManage Storage Management. For
information on manual Replace Member, see the topic Replacing An Online Physical Disk.
Patrol Read
The Patrol Read feature is designed as a preventative measure to ensure physical disk health and data integrity. Patrol
Read scans for and resolves potential problems on configured physical disks. The Dell OpenManage storage
management application can be used to start Patrol Read and change its behavior.
The following is an overview of Patrol Read behavior:
•Patrol Read runs on all disks on the controller that are configured as part of a virtual disk, including hot spares.
•Patrol Read does not run on physical disks that are not part of a virtual disk or are in Ready state.
•Patrol Read adjusts the amount of controller resources dedicated to Patrol Read operations based on
outstanding disk I/O. For example, if the system is busy processing I/O operation, then
resources to allow the I/O to take a higher priority.
•Patrol Read does not run on any disks involved in any of the following operations:
Patrol Read uses fewer
– Rebuild
– Replace Member
– Full or Background Initialization
– CC
– RLM or OCE
NOTE: By default, Patrol Read automatically runs every seven days on configured SAS and SATA hard
drives. Patrol Read is not necessary on SSD and is disabled by default.
For more information on Patrol Read, see the Dell OpenManage documentation at dell.com/support/manuals.
Redundant Path Support (For PERC H810 Only)
The PERC H810 adapter can detect and use redundant paths to disks contained in enclosures. This provides the ability to
connect two SAS cables between a controller and an enclosure for path redundancy. The controller is able to tolerate
the failure of a cable or Enclosure Management Module (EMM) by utilizing the remaining path.
When redundant paths exist, the controller automatically balances I/O load through both paths to each disk. Load
balancing increases throughput to virtual disks in storage enclosures and is automatically turned on when redundant
paths are detected. The ability to load balance I/O can be disabled using the Dell OpenManage storage management
application.
To set up your hardware to support redundant paths, see the topic Setting Up Redundant Path Support On The PERC
H810 Adapter.
NOTE: This support for redundant paths refers to path-redundancy only and not to controller-redundancy.
21
Physical Disk Failure Detection
Failed physical disks are detected and rebuilds automatically start to new disks that are inserted into the same slot.
Automatic rebuilds can also happen transparently with hot spares. If you have configured hot spares, the controllers
automatically try to use them to rebuild failed physical disks.
Using Persistent Hot Spare Slots
NOTE: The persistent hot spare slot feature is disabled by default.
The PERC H310, H710, H710P, and H810 cards can be configured so that the system backplane or storage enclosure disk
slots are dedicated as hot spare slots. This feature can be enabled using the Dell OpenManage storage management
application.
Once enabled, any slots with hot spares configured automatically become persistent hot spare slots. If a hot spare disk
fails or is removed, a replacement disk that is inserted into the same slot automatically becomes a hot spare with the
same properties as the one it is replacing. If the replacement disk does not match the disk protocol and technology, it
does not become a hot spare.
For more information on persistent hot spares, see the Dell OpenManage documentation at dell.com/support/manuals.
Physical Disk Hot Swapping
NOTE: To check if the backplane supports hot swapping, see the
Hot swapping is the manual replacement of a disk while the PERC H310, H710, H710P, or H810 cards are online and
performing their normal functions. The following requirements must be met before hot swapping a physical disk:
•The system backplane or enclosure must support hot swapping for the PERC H310, H710, H710P or H810 cards to
support hot swapping.
•The replacement disk must be of the same protocol and disk technology. For example, only a SAS hard drive can
replace a SAS hard drive; only a SATA SSD can replace a SATA SSD.
•The replacement disk must be of equal or greater capacity than the one it is replacing.
Owner’s Manual
of your system.
Using Replace Member And Revertible Hot Spares
The Replace Member functionality allows a previously commissioned hot spare to be reverted to a usable hot spare.
When a disk failure occurs within a virtual disk, an assigned hot spare (dedicated or global) is commissioned and begins
rebuilding until the virtual disk is optimal. After the failed disk is replaced (in the same slot) and the rebuild to the hot
spare is complete, the controller automatically starts to copy data from the commissioned hot spare to the newlyinserted disk. After the data is copied, the new disk is a part of the virtual disk and the hot spare is reverted to being a
ready hot spare. This allows hot spares to remain in specific enclosure slots. While the controller is reverting the hot
spare, the virtual disk remains optimal.
NOTE: The controller automatically reverts a hot spare only if the failed disk is replaced with a new disk in the
same slot. If the new disk is not placed in the same slot, a manual Replace Member operation can be used to revert
a previously commissioned hot spare.
NOTE: A Replace Member operation typically causes a temporary impact to disk performance. Once the operation
completes, performance returns to normal.
22
Controller Cache Preservation
The controller is capable of preserving its cache in the event of a system power outage or improper system shutdown.
The PERC H710, H710P, and H810 controllers are attached to a Battery Backup Unit (BBU) that provides backup power
during system power loss to preserve the controller's cache data.
Cache Preservation With Non-Volatile Cache (NVC)
In essence, the NVC module allows controller cache data to be stored indefinitely. If the controller has data in the cache
memory during a power outage or improper system shutdown, a small amount of power from the battery is used to
transfer cache data to a non-volatile flash storage where it remains until power is restored and the system is booted.
Recovering Cache Data
The dirty cache LED that is located on the H710 and H810 cards can be used to determine if cache data is being
preserved.
If a system power loss or improper system shutdown has occurred:
1.Restore the system power.
2.Boot the system.
3.To enter the BIOS Configuration Utility, select Managed Preserved Cache in the controller menu.
If there are no virtual disks listed, all preserved cache data has been written to disk successfully.
Battery Transparent Learn Cycle
NOTE: Batteries are only supported on PERC H710, H710P, and H810 cards.
A transparent learn cycle is a periodic operation that calculates the charge that is remaining in the battery to ensure
there is sufficient energy. The operation runs automatically, and causes no impact to the system or controller
performance.
The controller automatically performs the Transparent Learn Cycle (TLC) on the battery to calibrate and gauge its charge
capacity once every 90 days. The operation can be performed manually, if required.
NOTE: Virtual disks stay in Write Back mode, if enabled, during transparent learn cycle. When the TLC completes,
the controller sets the next TLC to +90 days.
TLC Time Frame
The time frame for completion of a learn cycle is a function of the battery charge capacity and the discharge and charge
currents used. For PERC H710 or H810 cards, the expected time frame for completion of a learn cycle is approximately
seven hours.
Conditions For Replacing The Battery
The PERC battery is marked Failed when the state or health of the battery is declared bad. If battery is declared failed
then the firmware runs learn cycles in subsequent reboots until the battery is replaced. The virtual disk then transitions
to Write Back mode.
23
24
Deploying The PERC Card
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the system.
NOTE: For information on removing and reinstalling system parts, see the Owner's Manual of the system at
dell.com/support/manuals.
NOTE: For more information on your storage controller, see the relevant storage controller documentation at
dell.com/support/manuals.
This document provides a set of high level installation and removal instructions for the following Dell PowerEdge RAID
Controllers (PERC):
•PERC H310 Adapter
•PERC H310 Mini Monolithic
•PERC H310 Mini Blade
•PERC H710 Adapter
•PERC H710P Adapter
•PERC H710 Mini Monolithic
•PERC H710P Mini Monolithic
•PERC H710 Mini Blade
•PERC H710P Mini Blade
•PERC H810 Adapter
3
Removing The PERC Controller
To remove the PERC controller:
1.Perform a controlled shutdown of the system and attached peripherals.
2.Disconnect the system from the electrical outlet and remove the system cover.
3.Remove the storage controller from the PCIe slot of the system.
CAUTION: When removing or replacing the PERC Mini Monolithic Controller, hold the card by its edges
marked by the blue touch points. Do not handle the card while holding the battery or the heatsink.
For more information, see to the relevant figures below.
25
Figure 1. Removing and Installing the PERC Adapter
1. PCIe slot
2. SAS cable connectors (2)
3. PERC adapter
4. screw (1)
Figure 2. Removing and Installing the PERC Mini Blade Controller
26
1. release lever (2)
2. PERC stack-up connector
3. PERC mini blade controller
4. screws (2)
Figure 3. Removing and Installing the PERC Mini Monolithic Controller
1. release lever (2)
2. storage-controller card holder
3. storage controller card
4. battery
5. heatsink
6. touch points (2)
7. storage-controller card connector on the
system board
8. guide pins (2)
Installing The PERC Controller
To install the PERC controller:
1.Perform a controlled shutdown of the system and attached peripherals.
2.Disconnect the system from the electrical outlet and remove the system cover.