Dell EqualLogic PS3070X User Manual

Hardware Mai nte nan ce
Hardware M aint
Copyright © 2006 EqualLogic, Inc.
September 2006
EqualLogic is a registered trademark of EqualLogic, Inc.
All trademarks and registered trademarks mentioned herein are the property of their respective owners.
Possession, use, or copying of the documentation or the software described in this publication is authorized only under the license agreement.
EqualLogic, Inc. will not be held liable for technical or editorial errors or omissions contained herein. Information in this document is subject to change.
PS Series Firmware Version 3.0
Part Number: 110-0040-R2
ii
Table of Contents
Preface ........................................................................................................v
Introduction to PS Series Storage Arrays ...................................................1
Steps for Setting Up and Using an Array ...................................................2
Step 1. Set Up the Array Hardware ............................................................3
A. Unpack Shipping Box and Gather Hardware ........................3
B. Mount Array in a Stable Rack ...............................................6
C. Connect Power Cables for Grounding ...................................8
D. Connect Array to a Network Switch .....................................9
E. Turn on Power to Array and Check LEDs for Errors ..........12
F. Connect Array to a Console Terminal .................................15
Step 2. Configure the Array and Create a Group ......................................16
Step 3. Set the RAID Policy .....................................................................19
Using the GUI to Set the RAID Policy ....................................19
Using the CLI to Set the RAID Policy .....................................23
Step 4. Create a Volume ...........................................................................25
Using the GUI to Create a Volume ..........................................26
Using the CLI to Create a Volume ...........................................29
Step 5. Connect to the Volume from a Host System ................................30
Advanced Operations and More Information ...........................................31
Index ..........................................................................................................35
iii

Preface

This QuickStart describes how to set up EqualLogic PS Series 3000 storage array hardware and create a PS Series group—a self-managing, iSCSI storage area network (SAN) that is affordable and easy to use, regardless of scale.
After setting up the group, see the PS Series Group Administration manual for information about managing the group.

Audience

This QuickStart is designed for administrators responsible for setting up array hardware and creating a group. Although administrators do not need extensive network or storage system experience, it may be useful to understand:
Basic networking concepts
Current network environment
User disk storage requirements
RAID configurations
Disk storage management
Note: This QuickStart describes using PS Series arrays in some common network
configurations. However, detailed information about setting up a network is beyond its scope.

Organization

This QuickStart is organized as follows:
Introduction to PS Series Storage Arrays
Steps for Setting Up and Using an Array
Step 1. Set Up the Array Hardware
Step 2. Configure the Array and Create a Group
Step 3. Set the RAID Policy
Step 4. Create a Volume
Step 5. Connect to the Volume from a Host System
Advanced Operations and More Information
v
PS Series 3000 QuickStart Preface

EqualLogic Website

The EqualLogic website, www.equallogic.com, has the latest product firmware and documentation, in addition to warranty information.

Product Documentation and Technical Support

For detailed information about PS Series arrays, groups, and volumes, see the following documentation:
•Release Notes. Provides the latest information about PS Series arrays.
QuickStart. Describes how to set up the PS Series Model 3000 array hardware and create a PS Series group.
Group Administration. Describes how to use the Group Manager graphical user interface (GUI) to manage a PS Series group. This manual provides comprehensive information about product concepts and procedures.
CLI Reference. Describes how to use the Group Manager command line interface (CLI) to manage a PS Series group and individual arrays.
Hardware Maintenance. Provides information about maintaining the PS Series Model 3000 array hardware.
The QuickStart and the Hardware Maintenance manual are printed and shipped with the product. They are also located on the documentation CD-ROM that is shipped with the product, along with the Group Administration and CLI Reference manuals and the Group Manager online help.
®
In addition, the Host Integration Tools for Windows
systems are available on the
EqualLogic website and on a CD-ROM that is shipped with the product.
Technical support on EqualLogic products is available for customers with arrays under warranty and customers with a valid support contract. You can obtain technical support in the following ways:
Visit the EqualLogic Customer Support website to download the latest documentation and firmware. Go to
www.equallogic.com and log in to
your support account. If you do not have an account, register for an account.
From the EqualLogic Customer Support website, you can submit a service request.
vi
PS Series 3000 QuickStart Preface
In the United States, call 877-887-7337. International customers should call +00 1 919-767-5729. If the issue is urgent, ask to speak with a member of the EqualLogic Customer Support team.
Send e-mail to
support@equallogic.com and clearly describe the issue or
problem.

Online Help

For help on the Group Manager graphical user interface (GUI) and command lilne interface (CLI), click expand the menu. Then, click
Tools in the bottom left corner of the GUI window to
Online Help.
The Group Manager CLI also provides help at the command line. In addition, the
setup utility provides help for each prompt.

Warranty Information

The license agreement and warranty information are included in the PS Series array shipping box. To register your array, go to
Support, and then click warranty registration.
www.equallogic.com, click

Restricted Access Requirement

PS Series arrays must be installed in a restricted access location. A restricted access location is an area that is intended only for qualified or trained personnel.
vii

Introduction to PS Series Storage Arrays

EqualLogic PS Series storage arrays deliver the benefits of consolidated storage in a storage area network (SAN) that is affordable and easy to use—regardless of its size. With intelligent, automated management and fast, flexible scalability, PS Series arrays greatly reduce storage acquisition and management costs. This QuickStart describes how to start using your PS Series array.
By grouping together one or more PS Series arrays connected to an IP network, you can create a PS Series group—a highly-scalable iSCSI SAN with a shared pool of storage space. Integrated virtualization software makes a group easy to manage and provides automatic RAID configuration, data provisioning, and load balancing. To increase SAN capacity and performance, connect another array to the network and add it to the group—data remains online at all times.
To ensure high reliability, PS Series storage arrays include RAID-protected disks, automatic disk sparing, redundant fans and power supplies, and dual high-performance control modules, each with three Gigabit Ethernet interfaces and a battery-backed cache.
A simple setup utility lets you quickly configure an array as a member of a new or existing group. RAID configuration and load balancing (network and data) occur automatically. Both graphical and command line user interfaces are available for group management.
In a multi-member group, you can separate space into storage pools, which allow you to organize storage according to usage, providing more control over resource allocation, while maintaining a single system management view.
Using the Group Manager graphical or command line user interface, you create volumes, assigning to each volume a pool, size, access controls, and other attributes. A volume can be spread across multiple disks and group members and is seen on the network as an iSCSI target. Members and volumes can move between pools to meet business objectives.
To connect to a volume, a host needs only a standards-compliant iSCSI initiator. Volume access can be restricted through IP address, initiator name, or CHAP (Challenge Handshake Authentication Protocol) credentials. Once connected, the volume is seen by the host as a regular disk that can be formatted as usual.
1
PS Series 3000 QuickStart Steps for Setting Up and Using an Array
At a minimum, a group consists of one array with one network connection, but you can configure three network interfaces for maximum array bandwidth. Data and network I/O are automatically load balanced across disks and interfaces—with no impact on data availability.
PS Series Group With Multiple Members
You can easily increase group capacity and bandwidth by adding arrays. When an array is added to a group, it obtains the group configuration from the existing members. Once you choose a RAID policy for the member, the pool is automatically expanded, and volume data and network I/O are load balanced across the pool members’ disks and network connections. Volumes continue to be accessible through the same iSCSI targets, and no host modifications are necessary. Management overhead remains the same, regardless of the group size.

Steps for Setting Up and Using an Array

To start using your PS Series array:
Step 1. Set up the array hardware configuration.
Step 2. Configure the array on the network and create a group.
Step 3. Log in to the group and specify the RAID policy for the array.
Step 4. Create a volume.
Step 5. Connect to the volume from a host system.
2
PS Series 3000 QuickStart Step 1. Set Up the Array Hardware

Step 1. Set Up the Array Hardware

A. Unpack Shipping Box and Gather Hardware

The order in which you unpack the shipping box is important for safety:
1. Open the outer shipping box and remove the accessory box.
2. Remove the accessories and ensure that you have the contents shown in the figure Shipping Box Contents.
3. Following the unpacking instructions in the shipping box, lift the array and place it on a flat surface that is protected from electrostatic discharge. Do not remove the plastic bag from the array until you are ready to install it in a rack.
4. Gather the hardware that is not included in the box, as described in the table Required Hardware – Not Supplied.
The array is heavy. Do not attempt to lift or install the array without assistance.
Shipping Box Contents
3
PS Series 3000 QuickStart Step 1. Set Up the Array Hardware
Description of Shipping Box Contents
Component Description
3U storage array chassis
Power cables Connects an array to one or more power sources. The shipping
Serial null modem cable
Four-pole rack assembly kit
Two-pole rack assembly kit
Electrostatic wrist strap Protects sensitive hardware from electrical discharge.
Documentation and CD-ROMs
Contains one or two control modules, two power supply/cooling modules, and eight or 16 disks.
box may contain multiple power cables to meet the electrical requirements of the country in which the array will reside.
Caution: Be sure to use only these enclosed power cables with
this product.
Creates a serial connection between an array and a console or terminal emulator. The cable has two DB9, 9-pin, female connectors and is used only for the initial member and group configuration or if there is no network access to the array.
Enables you to install an array in a four-pole rack. Instructions for assembly are included in the kit.
Enables you to install an array in a two-pole rack. Instructions for assembly are included in the kit.
Printed documentation includes the PS Series QuickStart, Hardware Maintenance, Release Notes, and SAN setup poster.
The Group Administration and CLI Reference manuals and the Group Manager online help are on the documentation CD-ROM, along with the QuickStart and Hardware Maintenance manuals.
Host Integration Tools for Windows documentation are on the HIT CD-ROM.
®
systems and related
License and warranty information is also included in the shipping box.
Note: Product returns will be accepted only in the original packaging or in
authorized packaging obtained from your PS Series support provider.
4
PS Series 3000 QuickStart Step 1. Set Up the Array Hardware
Array installation also requires the hardware described in Required Hardware –
Not Supplied. This hardware is not provided with your array.
Required Hardware – Not Supplied
Component Description
Standard 19” two­or four-pole rack
One or more network cables
Network switch Connects devices to a network. If possible, connect the array to
Computer or a console terminal
Provides easy access to storage arrays and other hardware in your computing environment.
Connects an array to a network switch. Use Category 5E or Category 6 cables with RJ45 connectors. You can also use Category 5 cables if they adhere to the TIA/EIA TSB95 standard.
Only one network connection is required for operation, but as many as six connections (maximum of three active) are possible.
different switches for high availability.
Enables you to perform the initial array and group configuration or manage the group when there is no active network connection. A computer must be running a terminal emulator.
The following table describes the optional hardware that you can use in a storage array installation. This hardware is not provided with your array.
Optional Hardware – Not Supplied
Component Description
One or two UPS systems
Provide a highly available source of power to an array. Each UPS system should be on a different circuit and must provide the correct type of voltage for an adequate amount of time.
5
PS Series 3000 QuickStart Step 1. Set Up the Array Hardware

B. Mount Array in a Stable Rack

A PS Series array must be mounted in a two-pole or four-pole 19” rack. Instructions for rack assembly and mounting an array are included with the two-pole assembly kit and the four-pole assembly kit in the array shipping box.
When mounting an array in a rack, you must meet the following recommendations and requirements:
Be sure there is sufficient space for air flow in front of and behind the array.
It is recommended that you attach the rack to the floor for added stability.
Be sure to support the array until it is completely mounted in the rack.
The location of the array must be properly vented and must meet the environmental, power, and physical requirements described in the following table.
PS Series Storage Array Requirements
Component Requirement
Weight of fully-loaded array 80 pounds or 36.36 kilograms
Operating temperature 41 to 104 degrees F / 5 to 40 degrees C
Storage temperature -22 to 140 degrees F / -30 to 60 degrees C
Maximum altitude 10,000 feet
Operational relative humidity 8 to 90% non-condensing
Thermal output of fully-loaded array 2200 BTU/hour, 660 watts
Shock 30 G for 2 ms
Vibration .1 G @ 10 to 100 hertz
Input voltage 90 to 264 VAC (auto-sensing)
Input current 5.5 amperes (maximum, single power supply)
@ 120 volts
Input frequency 50 to 60 hertz
Input power 660 VA
Power supplies Dual, 450 watts DC output
Height/Width/Depth 5.25” x 17 5/8” x 22.5”
13.33 cm x 44.77 cm x 56.25 cm
6
PS Series 3000 QuickStart Step 1. Set Up the Array Hardware
Four-Pole Rack Example
Be sure to support the array until it is completely mounted in the rack.
Two-Pole, Mid-Mount Rack Example
7
Loading...
+ 33 hidden pages