© 2021 Dell Inc. or its subsidiaries.
DELL EMC
POWERPROTECT DD
SERIES APPLIANCES
DD series is the ultimate protection storage appliance that is the next
generation of Dell EMC Data Domain appliances.
DD series delivers a fast, secure and an efficient solution that is
optimized for multi-cloud data protection and future demands.
DD series consists of the DD9900, DD9400, DD6900, DD3300 and a
software-defined appliance with PowerProtect DD Virtual Edition (DDVE).
Max Throughput
(DD Boost)
Logical Capacity
with Cloud Tier
Usable Capacity
with Cloud Tier
1
Logical capacity based on up to 50x deduplication (DD3300) and up to 65x deduplication (DD6900, DD9400, DD9900) based on additional hardwareassisted data compression of up to 30% better than previous generation. Actual capacity & throughput depends on application workload, deduplication,
and other settings.
2
High Availability configuration only, in a standard configuration SSDs are in the controller. The following systems support a high availability
active/standby configuration: DD9900, DD9400 and DD6900
3
Supported but not for factory racked orders

4x 10G BASE-T or
4x 10G SFP+
4x 10G BASE-T or
4x 10G SFP+
4x 10G BASE-T or
4x 10G SFP+
Optional Networking with
I/O Cards
The 10GBase-T card
can auto-negotiate
down to support
1GbE
Up to single dual-port
10GbE SLICs: Optical
Single quad-port
16Gbps FC HBA
Up to four quad port
10G Base-T, which
can auto-negotiate
down to support
1GbE
Up to four quad port
10G SFP+ (including
built-in)
Up to three dual port
25G SFP+
Up to 3 quad port
16Gb FC HBA
Up to four quad port
10G Base-T, which
can auto-negotiate
down to support
1GbE
Up to four quad port
10G SFP+ (including
built-in)
Up to three dual port
25G SFP+
Up to 3 quad port
16Gb FC HBA
Up to four quad port
10G Base-T
(including built-in),
which can auto-
negotiate down to
support 1GbE
Up to four quad port
10G SFP+
Up to four dual port
25G SFP+
Up to four dual port
100G
Up to 4 quad port
16Gb FC HBA
17.1” x 29.6” x 3.5”
2U EIA rack units
17.1” x 29.6” x 3.5”
2U EIA rack units
17.1” x 29.6” x 3.5”
2U EIA rack units
17.1” x 32.0” x 5.2”
3U EIA rack units
Power
100-120/200-240v~,
50/60 Hz
Operating Temperature/
Altitude3
10°C to 35°C,
35°C at 3,117 ft
10°C to 35°C,
35°C at 3,117 ft
10°C to 35°C,
35°C at 3,117 ft
10°C to 35°C,
35°C at 3,117 ft
Non-Operating
(Transportation)
Temperature
-40°C to +65°C
(-40°F to +149°F)
-40°C to +65°C
(-40°F to +149°F)
-40°C to +65°C
(-40°F to +149°F)
-40°C to +65°C
(-40°F to +149°F)
10% to 80%
with 29°C (84.2°F)
maximum dew point.
10% to 80%
with 29°C (84.2°F)
maximum dew point.
10% to 80%
with 29°C (84.2°F)
maximum dew point.
10% to 80%
with 29°C (84.2°F)
maximum dew point.
Operation Acoustic
Noise (Sound Power)
Operation Acoustic
Noise (Sound Pressure)

Statement of Compliance
Dell EMC Information Technology Equipment is compliant with all currently applicable regulatory requirements for
Electromagnetic Compatibility, Product Safety, and Environmental Regulations where placed on market.
Detailed regulatory information and verification of compliance is available at the Dell Regulatory Compliance
website. http://dell.com/regulatory_compliance
Software
Software features
Global Compressio n™, Data Invulnerability Architecture, including inline verification and integrated dual d isk parity RAID
6, snapshots, telnet, FTP, SSH, email alerts, scheduled capacity reclamation, Ethernet failover and aggregation, Link
Aggregation Control Protocol (LACP), VLAN tagging, IP aliasing, DD Boost, DD Encryption, DD Extended Retention, DD
Retention Lock, DD Virtual Tape Library (VTL) (for open systems and IBMi operating environments). Available ad d-ons
include: DD Boost, Cloud Tier for long-term retention, Cloud Disaster Recovery, and DD Replicator.
System management
PowerProtect DD Management Center, DD System Manager, SNMP, and command line management interface.
Data management
NFS v3 over TCP, CIFS and DD Boost over 1GbE or 10GbE or Fibre Channel, tape library emulation (VTL) over Fibre
Channel, and NDMP Tape Server.

ES40 Expansion shelf
External interface (host/expansion)
Dual 4 lane 12Gb/s serial attached SCSI II
(SAS) ports per Link Control Card (LCC)—
one for host and one for expansion
Connector type
SFF-8088 connectors (mini-SAS)
SAS cable length
Up to 5 meter
Disk drives
15-drive bays, supports, 3.5-inch form factor
4 TB 7.2K SAS drives
Dimensions
Height: 5.25 in (13.33 cm)
Width: 17.5 in (44.45 cm)
Depth: 14 in (35.56 cm)
Weight: 68 lbs (30.8 kg)
Operational
Power (VA): 272VA or 232W, (100-240V ~,
47 to 63 Hz)
Thermal Rating: 792 BTU/hr
Environmental
Ambient temperature: 50o F to 95o F (10o C to
35o C)
Temperature gradient: 36o F/hr (20oC/hr)
Relative humidity extremes: 20% to 80%
noncondensing
Elevation: -50 to 10000 ft (-16 to 3050 m)
Non-Operating (Transportation) Temperature:
Ambient temperature: -40o F to 149o F (-40o
C to 65o F)
Temperature gradient: 36o F/hr (20oC/hr)
Relative humidity: 10% to 90%
noncondensing
Elevation: -50 to 35,000 ft (-16 to 10,600 m)
DS60 Expansion shelf
External interface (host/expansion)
Quad 8 lane 12 Gb/s serial attached SCSI II
(SAS) ports per Link Control Card (LCC)—
Half of each port is blocked allowing the use
of standard mini-SAS-HD connectors – one
port is used for the host connection and the
other is used for expansion.
Connector type
SFF-8088 connectors (mini-SAS)
SAS cable length
Up to 5 meter
Disk drives
60-drive bays per DS60 expansion shelf,
support low profile, one inch high, 3.5-inch
form factor drives
Drive Choices: SAS (12 Gb/s), 4 TB or 8 TB
Dimensions
Height: 8.75 in (22.23 cm) 5U (4U plus 1U
cable management tray)
Width including rails: 17.50 in (44.45 cm)
Depth (chassis only): 34.5 in (87.63 cm)
Maximum depth (fully configured): 36.4 in
(92.46 cm)
Weight: 225.0 lbs (90.7 kg) (with FRUs
installed)
Operational
Power (VA): 785 VA or 770W (200-240V ~,
47 to 63 Hz)
Thermal Rating: 2627 BTU/hr
Environmental
Ambient temperature: 41o F to 104o F (5o C to
40o C)
Temperature gradient: 18o F/hr (10o C/hr)
Relative humidity extremes: 20% to 80%
noncondensing
Elevation: -50 to 7500 ft (-16 to 2300 m)
Non-Operating (Transportation) Temperature:
Ambient temperature: -40o F to 149o F (-40o
C to 65o F)
Temperature gradient: 45o F/hr (25oC/hr)
Relative humidity: 10% to 90%
noncondensing
Elevation: -50 to 35,000 ft (-16 to 10,600 m)
FS25 SSD shelf
External interface (host/expansion)
Dual 4 lane 12Gb/s serial attached SCSI II
(SAS) ports per Link Control Card (LCC)—
one for host and one for expansion
Connector type
SFF-8088 connectors (mini-SAS)
SAS cable length
Up to 5 meter
Disk drives
25-drive bays, supports, 2.5-inch form factor
3.84 TB SSD drives
Dimensions
Height: 3.40 in (8.46 cm)
Width: 17.5 in (44.45 cm)
Depth: 13.0 in (33.02 cm)
Weight: 22.0 lbs (10.0 kg)
Operational
Power (VA): 187VA or 136W, (100-240V ~,
47 to 63 Hz)
Thermal Rating: 464 BTU/hr
Environmental
Ambient temperature: 50o F to 95o F (10o C to
35o C)
Temperature gradient: 36o F/hr (20oC/hr)
Relative humidity extremes: 20% to 80%
noncondensing
Elevation: -50 to 10000 ft (-16 to 3050 m)
Non-Operating (Transportation)
Temperature:
Ambient temperature: -40o F to 149o F (-40o
C to 65o F)
Temperature gradient: 36o F/hr (20oC/hr)
Relative humidity: 10% to 90%
noncondensing
Elevation: -50 to 35,000 ft (-16 to 10,600 m)

DD series rack
Power configuration
Single phase is standard, optional 3phase.
Two power domains (base and
extended), each redundant.
Power inlet count
Either two or four (Single Phase
DD9900 HA with 4x DS60 or
DD9900/DD9900 HA with 5x DS60)
Plug types
L6-30P, 56PA322, 332P6W, 3750DP,
L7-30, 60309, CS-8365C, 9P54U2T,
3P-Wye, or 3P-Wye Flying Leads
PDU Power capacity
single-phase, 24A, 200-240 V~, 50/60
Hz
three-phase 3W+G, 40A, 200-240 V~,
50/60 Hz
three-phase 3W+N+PE, 24A, 200-240
V~, 50/60 Hz
Dimensions
40U available rack capacity
Height: 75 in (190.8 cm)
Width: 24.0 in (61.1 cm)
Depth: 39.0 in (99.2 cm)
Weight: 380 lbs (173 kg) when empty
A 60cmx120cm 42 U rack will be
available in Q1 2020
Contact a Dell Technologies Expert
© 2021 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC and other trademarks are
trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective
owners.