Safety Notices
Warning
n
DANGER
Do not lift the condensing unit by the refrigerant tubing or other components. These features will not support the condensing unit weight. Injury and unit damage may occur!
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/ modified from that of original manufactured specifications.
Warning
n
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
Warning
n
Do not use electrical appliances or accessories other than those supplied by the manufacturer.
Warning
n
Use caution when handling metal surface edges of all equipment.
DANGER
All utility connections and fixtures must be maintained in accordance with Local and national codes.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.
Warning
n
Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
Warning
n
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
Warning
n
DO NOT touch refrigeration lines inside units; some may exceed temperatures of 200°F (93.3°C).
Note
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. mtwkitchencare.com for manual updates, translations, or contact information for service agents in your area.
Warning
n
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
Section 1 General Information
Section 2 Installation
Section 3 Operation
Table of Contents
Model Numbers .................................................................................................................. 5
Serial Number Location ..................................................................................................... 5
Warranty Information ........................................................................................................ 5
Regulatory Certifications ..................................................................................................5
Dimensioned Drawings .....................................................................................................6
Location ..............................................................................................................................7
Weight of Equipment .........................................................................................................7
Clearance Requirements ....................................................................................................7
Dimensions ......................................................................................................................... 8
Electrical Service ................................................................................................................ 8
Voltage .......................................................................................................................................................8
Fuse/Circuit Breaker ..............................................................................................................................8
Ground Fault Circuit Interrupter .......................................................................................................8
Rated Amperages, Horsepower, Voltage & Power Cord Chart ...............................................9
Installation Instructions ....................................................................................................9
Louvers .................................................................................................................................................... 10
Plumbing...........................................................................................................................11
Leveling .............................................................................................................................11
Shelf Adjustments ...........................................................................................................11
Sliding Door Removal And Reinstall ...............................................................................12
Operation ..........................................................................................................................13
Temperature Control Settings ......................................................................................... 14
Reading The Temperature At Defrost Sensor ............................................................................ 14
Change Coil Temperature ................................................................................................................. 14
Change Other Parameter Values ....................................................................................................14
Section 4 Maintenance
Cleaning and Sanitizing Procedures ...............................................................................15
General .................................................................................................................................................... 15
Interior Cleaning .................................................................................................................................. 15
Exterior Cleaning ................................................................................................................................. 16
Plexiglas, Including Baffles ............................................................................................................... 16
Sliding Doors ......................................................................................................................................... 16
Drain ......................................................................................................................................................... 16
Cleaning the Condenser Coil .......................................................................................................... 16
Part Number ASM_SM 12/16 3
Section 5 Controls
Section 6 Diagrams
Table of Contents (continued)
Control Parameter Factory Settings ...............................................................................17
ASM-36 & ASM-48 ............................................................................................................19
ASM-60 .............................................................................................................................. 20
Remote Models ASM-36R, ASM-48R, ASM-60R* ............................................................ 21
4 Part Number ASM_SM 12/16
Section 1
General Information
Model Numbers
This manual covers standard units only.
NOTE: For custom units, consult Manitowoc KitchenCare at 1-844-724-CARE.
Drop-In Air Screen Merchandisers
ASM-36
ASM-48
Serial Number Location
The serial number on all self-contained Drop-In Air Screen Merchandisers is located on the mechanical section wall.
Always have the serial number of your unit available when calling for parts or service.
Warranty Information
Register your product for warranty.
Verify warranty information.
View and download a copy of your warranty.
At www.delfield.com/warranty
Regulatory Certifications
All models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
Part Number ASM_SM 12/16 5
General Information Section 1
Dimensioned Drawings
25.93” 66cm
63.48”
161cm
36.25” 92cm
48.25”
123cm
25.93” 66cm
Plan View, ASM-36 Plan View, ASM-48
63.48”
161cm
34.50” 88cm
Elevation View, ASM-36
46.50” 118cm
Elevation View, ASM-48
38.65” 98cm
24.83” 63cm
Left Section View,
ASM-36, ASM-48
12.50” 32cm
12.50” 32cm
12.50” 32cm
24.87” 63cm
Right Side View,
ASM-36, ASM-48
6 Part Number ASM_SM 12/16
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and servicing.
Warning
n
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
Location
Warning
n
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
Warning
n
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
Units are intended for indoor use only.
Unit is designed to maintain 36°F - 40°F at 80°F ambient room temperature (2°C - 4°C at 27°C) in 55% or lower relative humidity.
The location MUST be level, stable and capable of supporting the weight of the equipment.
The location MUST be free from and clear of combustible materials.
Equipment MUST be level both front to back and side to side.
Position the equipment so it will not tip or slide.
Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to Clearance Requirements chart on page 7.
Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
Weight of Equipment
Warning
n
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
Warning
n
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
Model Weight
ASM-36
ASM-48
425lbs (193kg)
500lbs (227kg)
Clearance Requirements
DANGER
Minimum clearance requirements are the same for noncombustible locations as for combustible locations. The flooring under the appliance must be made of a noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be maintained. Do not obstruct vents or openings.
Sides
1” (2.5cm)
Keep the vents clean and free of obstruction.
Part Number ASM_SM 12/16 7
Installation Section 2
Dimensions
Model Length Depth Height
ASM-36 36.25”
(92cm)
ASM-48 48.25”
(123cm)
Model Display Storage
ASM-36 8.2ft
ASM-48 11.3ft
These units are installed by placing them into the counter from above. The counter cutout sizes are as follows.
Model Counter Cutout Dimensions
ASM-36 35.13” x 25.50” (89cm x 65cm)
ASM-48 47.13” x 25.50” (120cm x 65cm)
Model Louver Cutout Dimensions
ASM-36 28.00” x 17.00” (71cm x 42cm)
ASM-48 28.00” x 17.00” (71cm x 42cm)
Model Control Cutout Dimensions
ASM-36 6.75” x 4.37” (17cm x 11cm )
ASM-48 6.75” x 4.37” (17cm x 11cm )
25.93”
(66cm)
25.93”
(66cm)
63.48“
(161cm)
63.48“
(161cm)
3
3
Electrical Service
DANGER
Check all wiring connections, including factory terminals, before operation. Connections can become loose during shipment and installation.
Warning
n
This appliance must be grounded and all field wiring must conform to all applicable local and national codes. Refer to rating plate for proper voltage. It is the responsibility of the end user to provide the disconnect means to satisfy the authority having jurisdiction.
VOLTAGE
All electrical work, including wire routing and grounding, must conform to local, state and national electrical codes.
The following precautions must be observed:
The equipment must be grounded.
A separate fuse/circuit breaker must be provided for each unit.
Check all green ground screws, cables and wire connections to verify they are tight before start-up.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each unit.
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc does not recommend the use of GFCI/GFI circuit protection to energize our equipment. If code requires the use of a GFCI/GFI then you must follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend the use of GFCI/GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers.